메뉴 건너뛰기




Volumn 219, Issue , 2014, Pages 80-87

Capacitive detection of micrometric airborne particulate matter for solid-state personal air quality monitors

Author keywords

Air pollution; Capacitive sensing; Microelectrodes; Portable dust monitoring

Indexed keywords

MICROELECTRODES;

EID: 84907522827     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2014.09.003     Document Type: Article
Times cited : (51)

References (28)
  • 1
    • 0028887339 scopus 로고
    • Particulate air pollution and acute health effects
    • A. Seaton, W. MacNee, K. Donaldson, and D. Godden Particulate air pollution and acute health effects Lancet 345 1995 176 178
    • (1995) Lancet , vol.345 , pp. 176-178
    • Seaton, A.1    Macnee, W.2    Donaldson, K.3    Godden, D.4
  • 3
    • 84880789775 scopus 로고    scopus 로고
    • Air pollution and lung cancer incidence in 17 European cohorts: Prospective analyses from the European study of cohorts for air pollution effects (ESCAPE)
    • O. Raaschou-Nielsen Air pollution and lung cancer incidence in 17 European cohorts: prospective analyses from the European study of cohorts for air pollution effects (ESCAPE) Lancet Oncol. 14 2013 813 822
    • (2013) Lancet Oncol. , vol.14 , pp. 813-822
    • Raaschou-Nielsen, O.1
  • 4
    • 84874544740 scopus 로고    scopus 로고
    • Milano summer particulate matter (PM10) triggers lung inflammation and extra pulmonary adverse events in mice
    • F. Farina, G. Sancini, C. Battaglia, V. Tinaglia, P. Mantecca, M. Camatini, and P. Palestini Milano summer particulate matter (PM10) triggers lung inflammation and extra pulmonary adverse events in mice PLOS ONE 8 2013 e56636
    • (2013) PLOS ONE , vol.8 , pp. 56636
    • Farina, F.1    Sancini, G.2    Battaglia, C.3    Tinaglia, V.4    Mantecca, P.5    Camatini, M.6    Palestini, P.7
  • 6
    • 79955635814 scopus 로고    scopus 로고
    • Long-term changes in PM10 levels in urban air in relation with air quality control efforts
    • K.H. Kim, and Z.H. Shon Long-term changes in PM10 levels in urban air in relation with air quality control efforts Atmos. Environ. 45 2011 3309 3317
    • (2011) Atmos. Environ. , vol.45 , pp. 3309-3317
    • Kim, K.H.1    Shon, Z.H.2
  • 9
    • 79953296189 scopus 로고    scopus 로고
    • Characterizing local traffic contributions to particulate air pollution in street canyons using mobile monitoring techniques
    • L.M. Zwack, C.J. Paciorek, J.D. Spengler, and J.I. Levy Characterizing local traffic contributions to particulate air pollution in street canyons using mobile monitoring techniques Atmos. Environ. 45 2011 2507 2514
    • (2011) Atmos. Environ. , vol.45 , pp. 2507-2514
    • Zwack, L.M.1    Paciorek, C.J.2    Spengler, J.D.3    Levy, J.I.4
  • 11
    • 0032188983 scopus 로고    scopus 로고
    • Methods of aerosol measurement before the1960s
    • K.R. Spurny Methods of aerosol measurement before the1960s Aerosol Sci. Technol. 29 1998 329 349
    • (1998) Aerosol Sci. Technol. , vol.29 , pp. 329-349
    • Spurny, K.R.1
  • 12
    • 84895059951 scopus 로고    scopus 로고
    • Microfabricated air-microfluidic sensor for personal monitoring of airborne particulate matter: Design, fabrication, and experimental results
    • I. Paprotny Microfabricated air-microfluidic sensor for personal monitoring of airborne particulate matter: design, fabrication, and experimental results Sens. Actuators A 201 2013 506 516
    • (2013) Sens. Actuators A , vol.201 , pp. 506-516
    • Paprotny, I.1
  • 14
    • 0019037939 scopus 로고
    • Continuous flow, single-particle-counting condensation nucleus counter
    • J.K. Agarwal, and G.J. Sem Continuous flow, single-particle-counting condensation nucleus counter J. Aerosol Sci. 11 1980 343 357
    • (1980) J. Aerosol Sci. , vol.11 , pp. 343-357
    • Agarwal, J.K.1    Sem, G.J.2
  • 16
    • 77954260151 scopus 로고    scopus 로고
    • Single-cell microfluidic impedance cytometry: A review
    • T. Sun, and H. Morgan Single-cell microfluidic impedance cytometry: a review Microfluid. Nanofluid. 8 2010 423 443
    • (2010) Microfluid. Nanofluid. , vol.8 , pp. 423-443
    • Sun, T.1    Morgan, H.2
  • 17
    • 78649754356 scopus 로고    scopus 로고
    • Real-time monitoring of wear debris in lubrication oil using a microfluidic inductive coulter counting device
    • L. Du, J. Zhe, J. Carletta, R. Veillette, and F. Choy Real-time monitoring of wear debris in lubrication oil using a microfluidic inductive coulter counting device Microfluid. Nanofluid. 9 2010 1241 1245
    • (2010) Microfluid. Nanofluid. , vol.9 , pp. 1241-1245
    • Du, L.1    Zhe, J.2    Carletta, J.3    Veillette, R.4    Choy, F.5
  • 18
    • 84859228502 scopus 로고    scopus 로고
    • Electrical detection of single pollen allergen particles using electrode-embedded microchannels
    • C. Kawaguchi, T. Noda, M. Tsutsui, M. Taniguchi, S. Kawano, and T. Kawaii Electrical detection of single pollen allergen particles using electrode-embedded microchannels J. Phys.: Condens. Matter 24 2012 164202-1 164202-6
    • (2012) J. Phys.: Condens. Matter , vol.24 , pp. 1642021-1642026
    • Kawaguchi, C.1    Noda, T.2    Tsutsui, M.3    Taniguchi, M.4    Kawano, S.5    Kawaii, T.6
  • 20
    • 0004119084 scopus 로고    scopus 로고
    • 2nd ed. John Wiley and Sons New York
    • W.C. Hinds Aerosol Technology 2nd ed. 1999 John Wiley and Sons New York
    • (1999) Aerosol Technology
    • Hinds, W.C.1
  • 21
    • 0029346331 scopus 로고
    • Mechanisms of removal of micron-sized particles by high-frequency ultrasonic waves
    • G. Brereton, and Q. Qi Mechanisms of removal of micron-sized particles by high-frequency ultrasonic waves IEEE Trans. Ultrason. Ferroelectr. Freq. Control 42 1995 619 629
    • (1995) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.42 , pp. 619-629
    • Brereton, G.1    Qi, Q.2
  • 22
    • 73849102814 scopus 로고    scopus 로고
    • AttoFarad resolution potentiostat for electrochemical measurements on nanoscale biomolecular interfacial systems
    • M. Carminati, G. Ferrari, and M. Sampietro AttoFarad resolution potentiostat for electrochemical measurements on nanoscale biomolecular interfacial systems Rev. Sci. Instrum. 80 2009 124701-1 124701-10
    • (2009) Rev. Sci. Instrum. , vol.80 , pp. 1247011-12470110
    • Carminati, M.1    Ferrari, G.2    Sampietro, M.3
  • 23
    • 84868151680 scopus 로고    scopus 로고
    • Accuracy and resolution limits in quartz and silicon substrates with microelectrodes for electrochemical biosensors
    • M. Carminati, M. Vergani, G. Ferrari, L. Caranzi, M. Caironi, and M. Sampietro Accuracy and resolution limits in quartz and silicon substrates with microelectrodes for electrochemical biosensors Sens. Actuators B 174 2012 168 175
    • (2012) Sens. Actuators B , vol.174 , pp. 168-175
    • Carminati, M.1    Vergani, M.2    Ferrari, G.3    Caranzi, L.4    Caironi, M.5    Sampietro, M.6
  • 24
    • 0032643609 scopus 로고    scopus 로고
    • Dielectric properties and electric conductivity of talc and doped talc
    • A. Kirak, H. Yilmaz, S. Güler, and Ç. Güler Dielectric properties and electric conductivity of talc and doped talc J. Phys. D: Appl. Phys. 32 1999 1919 1927
    • (1999) J. Phys. D: Appl. Phys. , vol.32 , pp. 1919-1927
    • Kirak, A.1    Yilmaz, H.2    Güler, S.3    Güler Ç.4
  • 25
    • 33748921942 scopus 로고    scopus 로고
    • Size distribution of atmospheric particulate matter at traffic exposed sites in the urban area of Milan (Italy)
    • G. Lonati, and M. Giugliano Size distribution of atmospheric particulate matter at traffic exposed sites in the urban area of Milan (Italy) Atmos. Environ. 40 2006 264 274
    • (2006) Atmos. Environ. , vol.40 , pp. 264-274
    • Lonati, G.1    Giugliano, M.2
  • 26
    • 80055026879 scopus 로고    scopus 로고
    • Individual air-borne particle mass measurement using high-frequency micromechanical resonators
    • A. Hajjam, J.C. Wilson, and S. Pourkamali Individual air-borne particle mass measurement using high-frequency micromechanical resonators IEEE Sens. J. 11 2011 2883 2890
    • (2011) IEEE Sens. J. , vol.11 , pp. 2883-2890
    • Hajjam, A.1    Wilson, J.C.2    Pourkamali, S.3
  • 27
    • 84887119176 scopus 로고    scopus 로고
    • Silicon resonant nanopillar sensors for airborne titanium dioxide engineered nanoparticle mass detection
    • H.S. Wasisto, S. Merzsch, A. Stranz, A. Waag, E. Uhde, T. Salthammer, and E. Peiner Silicon resonant nanopillar sensors for airborne titanium dioxide engineered nanoparticle mass detection Sens. Actuators B 189 2013 146 156
    • (2013) Sens. Actuators B , vol.189 , pp. 146-156
    • Wasisto, H.S.1    Merzsch, S.2    Stranz, A.3    Waag, A.4    Uhde, E.5    Salthammer, T.6    Peiner, E.7
  • 28
    • 82755189674 scopus 로고    scopus 로고
    • ZeptoFarad capacitance detection with a miniaturized CMOS current front-end for nanoscale sensors
    • M. Carminati, G. Ferrari, F. Guagliardo, and M. Sampietro ZeptoFarad capacitance detection with a miniaturized CMOS current front-end for nanoscale sensors Sens. Actuators A 172 2011 117 123
    • (2011) Sens. Actuators A , vol.172 , pp. 117-123
    • Carminati, M.1    Ferrari, G.2    Guagliardo, F.3    Sampietro, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.