메뉴 건너뛰기




Volumn 61, Issue 12, 2014, Pages 7092-7104

An open-switch fault detection method and tolerance controls based on SVM in a grid-connected t-type rectifier with unity power factor

Author keywords

Fault diagnosis; open switch fault; T type rectifier; tolerance control

Indexed keywords

ELECTRIC POWER FACTOR; ELECTRIC RECTIFIERS; FAILURE ANALYSIS; FAULT TOLERANCE; RECTIFYING CIRCUITS; TOPOLOGY; VECTOR SPACES;

EID: 84907459293     PISSN: 02780046     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIE.2014.2316228     Document Type: Article
Times cited : (148)

References (27)
  • 1
    • 84875629235 scopus 로고    scopus 로고
    • Thermal analysis of multilevel grid-side converters for 10-MW wind turbines under low-voltage ride through
    • Mar./Apr.
    • K. Ma, F. Blaabjerg, and M. Liserre, "Thermal analysis of multilevel grid-side converters for 10-MW wind turbines under low-voltage ride through," IEEE Trans. Ind. Appl., vol. 49, no. 2, pp. 909-921, Mar./Apr. 2013.
    • (2013) IEEE Trans. Ind. Appl. , vol.49 , Issue.2 , pp. 909-921
    • Ma, K.1    Blaabjerg, F.2    Liserre, M.3
  • 2
    • 84873374990 scopus 로고    scopus 로고
    • Use of stored energy in PMSG rotor inertia for low-voltage ride-through in back-to-back NPC converter-based wind power systems
    • May
    • S. Alepuz, A. Calle, S. Busquets-Monge, S. Kouro, and B. Wu, "Use of stored energy in PMSG rotor inertia for low-voltage ride-through in back-to-back NPC converter-based wind power systems," IEEE Trans. Ind. Electron., vol. 60, no. 5, pp. 1787-1796, May 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.5 , pp. 1787-1796
    • Alepuz, S.1    Calle, A.2    Busquets-Monge, S.3    Kouro, S.4    Wu, B.5
  • 3
    • 84870569933 scopus 로고    scopus 로고
    • Digitized feedforward compensation method for high-power-density three-phase vienna PFC converter
    • Apr.
    • L. Hang, M. Zhang, L. M. Tolbert, and Z. Lu, "Digitized feedforward compensation method for high-power-density three-phase vienna PFC converter," IEEE Trans. Ind. Electron., vol. 60, no. 4, pp. 1512-1519, Apr. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.4 , pp. 1512-1519
    • Hang, L.1    Zhang, M.2    Tolbert, L.M.3    Lu, Z.4
  • 4
    • 84866599662 scopus 로고    scopus 로고
    • Fast-predictive optimal control of NPC multilevel converters
    • Feb.
    • J. D. Barros, J. F. A. Silva, and É. G. A. Jesus, "Fast-predictive optimal control of NPC multilevel converters," IEEE Trans. Ind. Electron., vol. 60, no. 2, pp. 619-627, Feb. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.2 , pp. 619-627
    • Barros, J.D.1    Silva, J.F.A.2    Jesus, E.G.A.3
  • 5
    • 80155125007 scopus 로고    scopus 로고
    • Medium voltage-high power converter topologies comparison procedure, for a 6.6 kV drive application using 4.5 kV IGBT modules
    • Mar.
    • A. Sanchez-Ruiz, M. Mazuela, S. Alvarez, G. Abad, and I. Baraia, "Medium voltage-high power converter topologies comparison procedure, for a 6.6 kV drive application using 4.5 kV IGBT modules," IEEE Trans. Ind. Electron., vol. 59, no. 3, pp. 1462-1476, Mar. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.3 , pp. 1462-1476
    • Sanchez-Ruiz, A.1    Mazuela, M.2    Alvarez, S.3    Abad, G.4    Baraia, I.5
  • 6
    • 84877771101 scopus 로고    scopus 로고
    • Analysis of high-efficiency three-phase two-and three-level unidirectional hybrid rectifiers
    • Sep.
    • T. B. Soeiro and J. W. Kolar, "Analysis of high-efficiency three-phase two-and three-level unidirectional hybrid rectifiers," IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 3589-3601, Sep. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.9 , pp. 3589-3601
    • Soeiro, T.B.1    Kolar, J.W.2
  • 7
    • 84886453886 scopus 로고    scopus 로고
    • New modulation techniques for a leakage current reduction and a neutral-point voltage balance in transformerless photovoltaic systems using a three-level inverter
    • Apr.
    • J. S. Lee and K. B. Lee, "New modulation techniques for a leakage current reduction and a neutral-point voltage balance in transformerless photovoltaic systems using a three-level inverter," IEEE Trans. Power Electron., vol. 29, no. 4, pp. 1720-1732, Apr. 2014.
    • (2014) IEEE Trans. Power Electron. , vol.29 , Issue.4 , pp. 1720-1732
    • Lee, J.S.1    Lee, K.B.2
  • 10
    • 84867087707 scopus 로고    scopus 로고
    • Design and implementation of a highly efficient three-level T-type converter for low-voltage applications
    • Feb.
    • M. Schweizer and J. W. Kolar, "Design and implementation of a highly efficient three-level T-type converter for low-voltage applications," IEEE Trans. Power Electron., vol. 28, no. 2, pp. 899-907, Feb. 2013.
    • (2013) IEEE Trans. Power Electron. , vol.28 , Issue.2 , pp. 899-907
    • Schweizer, M.1    Kolar, J.W.2
  • 11
    • 84873380702 scopus 로고    scopus 로고
    • The new high-efficiency hybrid neutralpoint-clamped converter
    • May
    • T. B. Soeiro and J. W. Kolar, "The new high-efficiency hybrid neutralpoint-clamped converter," IEEE Trans. Ind. Electron., vol. 60, no. 5, pp. 1919-1935, May 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.5 , pp. 1919-1935
    • Soeiro, T.B.1    Kolar, J.W.2
  • 12
    • 85008034272 scopus 로고    scopus 로고
    • Development and implementation of a novel fault diagnostic and protection technique for IPM motor drives
    • Jan.
    • M. A. S. K. Khan and M. Azizur Rahman, "Development and implementation of a novel fault diagnostic and protection technique for IPM motor drives," IEEE Trans. Ind. Electron., vol. 56, no. 1, pp. 85-92, Jan. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.1 , pp. 85-92
    • Khan, M.A.S.K.1    Azizur Rahman, M.2
  • 13
    • 84867782211 scopus 로고    scopus 로고
    • Fault diagnosis of threeparallel voltage-source converter for a high power wind turbine
    • Aug.
    • Y. J. Ko, K. B. Lee, D. C. Lee, and J. M. Kim, "Fault diagnosis of threeparallel voltage-source converter for a high power wind turbine," IET Power Electron., vol. 5, no. 7, pp. 1058-1067, Aug. 2012.
    • (2012) IET Power Electron. , vol.5 , Issue.7 , pp. 1058-1067
    • Ko, Y.J.1    Lee, K.B.2    Lee, D.C.3    Kim, J.M.4
  • 14
    • 84880903671 scopus 로고    scopus 로고
    • Diagnosis and faulttolerant control of three-phase ac-dc PWM converter systems
    • Jul./Aug.
    • W. S. Im, J. M. Kim, D. C. Lee, and K. B. Lee, "Diagnosis and faulttolerant control of three-phase ac-dc PWM converter systems," IEEE Trans. Ind. Appl., vol. 49, no. 4, pp. 1539-1547, Jul./Aug. 2013.
    • (2013) IEEE Trans. Ind. Appl. , vol.49 , Issue.4 , pp. 1539-1547
    • Im, W.S.1    Kim, J.M.2    Lee, D.C.3    Lee, K.B.4
  • 15
    • 84876219094 scopus 로고    scopus 로고
    • A new algorithm for real-time multiple open-circuit fault diagnosis in voltage-fed PWM motor drives by the reference current errors
    • Aug.
    • J. O. Estima and A. J. M. Cardoso, "A new algorithm for real-time multiple open-circuit fault diagnosis in voltage-fed PWM motor drives by the reference current errors," IEEE Trans. Ind. Electron., vol. 60, no. 8, pp. 3496-3505, Aug. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.8 , pp. 3496-3505
    • Estima, J.O.1    Cardoso, A.J.M.2
  • 16
    • 84877753760 scopus 로고    scopus 로고
    • Open-circuit fault diagnosis in PMSG drives for wind turbine applications
    • Sep.
    • N. M. A. Freire, J. O. Estima, and A. J. M. Cardoso, "Open-circuit fault diagnosis in PMSG drives for wind turbine applications," IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 3957-3967, Sep. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.9 , pp. 3957-3967
    • Freire, N.M.A.1    Estima, J.O.2    Cardoso, A.J.M.3
  • 17
    • 67651180997 scopus 로고    scopus 로고
    • Detection method for opencircuit fault in neutral-point-clamped inverter systems
    • Jul.
    • T. J. Kim, W. C. Lee, and D. S. Hyun, "Detection method for opencircuit fault in neutral-point-clamped inverter systems," IEEE Trans. Ind. Electron., vol. 56, no. 7, pp. 2754-2763, Jul. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.7 , pp. 2754-2763
    • Kim, T.J.1    Lee, W.C.2    Hyun, D.S.3
  • 18
    • 77953627084 scopus 로고    scopus 로고
    • Survey on fault operation on multilevel inverters
    • Jul.
    • P. Lezana et al., "Survey on fault operation on multilevel inverters," IEEE Trans. Ind. Electron., vol. 57, no. 7, pp. 2207-2218, Jul. 2010.
    • (2010) IEEE Trans. Ind. Electron. , vol.57 , Issue.7 , pp. 2207-2218
    • Lezana, P.1
  • 19
    • 84859058385 scopus 로고    scopus 로고
    • Method for detecting an open-switch fault in a grid-connected NPC inverter system
    • Jun.
    • U. M. Choi, H. G. Jeong, K. B. Lee, and F. Blaabjerg, "Method for detecting an open-switch fault in a grid-connected NPC inverter system," IEEE Trans. Power Electron., vol. 27, no. 6, pp. 2726-2739, Jun. 2012.
    • (2012) IEEE Trans. Power Electron. , vol.27 , Issue.6 , pp. 2726-2739
    • Choi, U.M.1    Jeong, H.G.2    Lee, K.B.3    Blaabjerg, F.4
  • 20
    • 84870893515 scopus 로고    scopus 로고
    • Fault detection and tolerant control of 3-phase NPC active rectifier
    • Jun.
    • H. K. Ku, W. S. Im, J. M. Kim, and Y. S. Suh, "Fault detection and tolerant control of 3-phase NPC active rectifier," in Proc. ECCE, Jun. 2012, pp. 4519-4524.
    • (2012) Proc. ECCE , pp. 4519-4524
    • Ku, H.K.1    Im, W.S.2    Kim, J.M.3    Suh, Y.S.4
  • 21
    • 84893242398 scopus 로고    scopus 로고
    • Diagnosis and tolerant strategy of an open-switch fault for T-type three-level inverter systems
    • Jan./Feb.
    • U. M. Choi, K. B. Lee, and F. Blaabjerg, "Diagnosis and tolerant strategy of an open-switch fault for T-type three-level inverter systems," IEEE Trans. Ind. Appl., vol. 50, no. 1, pp. 495-508, Jan./Feb. 2014.
    • (2014) IEEE Trans. Ind. Appl. , vol.50 , Issue.1 , pp. 495-508
    • Choi, U.M.1    Lee, K.B.2    Blaabjerg, F.3
  • 22
    • 77954615301 scopus 로고    scopus 로고
    • Performance evaluation of fault-tolerant neutral-point-clamped converters
    • Aug.
    • S. Ceballos, J. Pou, E. Robles, J. Zaragoza, and J. L. Martín, "Performance evaluation of fault-tolerant neutral-point-clamped converters," IEEE Trans. Ind. Electron., vol. 57, no. 8, pp. 2709-2718, Aug. 2010.
    • (2010) IEEE Trans. Ind. Electron. , vol.57 , Issue.8 , pp. 2709-2718
    • Ceballos, S.1    Pou, J.2    Robles, E.3    Zaragoza, J.4    Martín, J.L.5
  • 23
    • 84855387046 scopus 로고    scopus 로고
    • Analysis and design of active NPC (ANPC) inverters for fault-tolerant operation of high-power electrical drives
    • Feb.
    • J. Li, A. Q. Huang, Z. Liang, and S. Bhattacharya, "Analysis and design of active NPC (ANPC) inverters for fault-tolerant operation of high-power electrical drives," IEEE Trans. Ind. Electron., vol. 27, no. 2, pp. 519-533, Feb. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.27 , Issue.2 , pp. 519-533
    • Li, J.1    Huang, A.Q.2    Liang, Z.3    Bhattacharya, S.4
  • 24
    • 75449113852 scopus 로고    scopus 로고
    • A unity-power-factor IPT pickup for high-power applications
    • Feb.
    • N. A. Keeling, G. A. Covic, and J. T. Boys, "A unity-power-factor IPT pickup for high-power applications," IEEE Trans. Ind. Electron., vol. 57, no. 2, pp. 744-751, Feb. 2010.
    • (2010) IEEE Trans. Ind. Electron. , vol.57 , Issue.2 , pp. 744-751
    • Keeling, N.A.1    Covic, G.A.2    Boys, J.T.3
  • 25
    • 84880894765 scopus 로고    scopus 로고
    • Equivalence of SVM and carrier-based PWM in three-phase/wire/level vienna rectifier and capability of unbalanced-load control
    • Jan.
    • L. Hang, B. Li, M. Zhang, Y. Wang, and L. M. Tolbert, "Equivalence of SVM and carrier-based PWM in three-phase/wire/level vienna rectifier and capability of unbalanced-load control," IEEE Trans. Ind. Electron., vol. 61, no. 1, pp. 20-28, Jan. 2014.
    • (2014) IEEE Trans. Ind. Electron. , vol.61 , Issue.1 , pp. 20-28
    • Hang, L.1    Li, B.2    Zhang, M.3    Wang, Y.4    Tolbert, L.M.5
  • 26
    • 0036686090 scopus 로고    scopus 로고
    • Reduced-parts-count multilevel rectifiers
    • Aug.
    • K. A. Corzine and J. R. Baker, "Reduced-parts-count multilevel rectifiers," IEEE Trans. Ind. Electron., vol. 49, no. 4, pp. 766-774, Aug. 2002.
    • (2002) IEEE Trans. Ind. Electron. , vol.49 , Issue.4 , pp. 766-774
    • Corzine, K.A.1    Baker, J.R.2
  • 27
    • 0035397759 scopus 로고    scopus 로고
    • A new simplified space-vector PWM method for three-level inverters
    • Jul.
    • J. H. Seo, C. H. Choi, and D. S. Hyun, "A new simplified space-vector PWM method for three-level inverters," IEEE Trans. Power Electron., vol. 16, no. 4, pp. 545-550, Jul. 2001
    • (2001) IEEE Trans. Power Electron. , vol.16 , Issue.4 , pp. 545-550
    • Seo, J.H.1    Choi, C.H.2    Hyun, D.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.