메뉴 건너뛰기




Volumn 101, Issue , 2015, Pages 84-91

Amperometric inhibition biosensors based on horseradish peroxidase and gold sononanoparticles immobilized onto different electrodes for cyanide measurements

Author keywords

Cyanide; Enzyme biosensor; Gold sononanoparticles; Horseradish peroxidase; Sonogel carbon

Indexed keywords

CARBON; CYANIDES; ELECTRODES; ENZYME ELECTRODES; ENZYME IMMOBILIZATION; GOLD; PHENOLS; ENZYME INHIBITION; ENZYMES; FOOD PRODUCTS; GLASSY CARBON;

EID: 84907358979     PISSN: 15675394     EISSN: 1878562X     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2014.08.003     Document Type: Article
Times cited : (59)

References (44)
  • 1
    • 84885997287 scopus 로고    scopus 로고
    • Amperometric inhibition biosensor for the determination of cyanide
    • Ghanavati M., Azad R.R., Mousavi S.A. Amperometric inhibition biosensor for the determination of cyanide. Sensors Actuators B 2014, 190:858-864.
    • (2014) Sensors Actuators B , vol.190 , pp. 858-864
    • Ghanavati, M.1    Azad, R.R.2    Mousavi, S.A.3
  • 2
    • 84887298724 scopus 로고    scopus 로고
    • Dithizone as novel and efficient chromogenic probe for cyanid detection in aqueous media through nucleophilic addition into diazenylthione moiety
    • Tavallali H., Deilamy-Rad G., Parhami A., Dithizone S.K. Dithizone as novel and efficient chromogenic probe for cyanid detection in aqueous media through nucleophilic addition into diazenylthione moiety. Spectrochim. Acta A Mol. Biomol. Spectrosc. 2014, 121:139-146.
    • (2014) Spectrochim. Acta A Mol. Biomol. Spectrosc. , vol.121 , pp. 139-146
    • Tavallali, H.1    Deilamy-Rad, G.2    Parhami, A.3    Dithizone, S.K.4
  • 3
    • 84870812076 scopus 로고    scopus 로고
    • A multi-pumping flow-based procedure with improved sensitivity for the spectrophotometric determination of acid-dissociable cyanide in natural waters
    • Frizzarin R.M., Rocha F.R.P. A multi-pumping flow-based procedure with improved sensitivity for the spectrophotometric determination of acid-dissociable cyanide in natural waters. Anal. Chim. Acta. 2013, 758:108-113.
    • (2013) Anal. Chim. Acta. , vol.758 , pp. 108-113
    • Frizzarin, R.M.1    Rocha, F.R.P.2
  • 5
    • 84907309592 scopus 로고    scopus 로고
    • C.E.E. (European community) Decrees No. 98/83CE (November 1998) and No. 75/440 (June 1975).
    • C.E.E. (European community) Decrees No. 98/83CE (November 1998) and No. 75/440 (June 1975).
  • 6
    • 0012965948 scopus 로고    scopus 로고
    • Australian and New Zealand Environmental and Conservation Council (ANZECC) Agriculture and Resource Management Council of Australia and New Zealand
    • Australian and New Zealand Environmental and Conservation Council (ANZECC), Agriculture and Resource Management Council of Australia and New Zealand Australian Water Quality Guidelines for Fresh and Marine Water 2000, 3.4-3.5.
    • (2000) Australian Water Quality Guidelines for Fresh and Marine Water , pp. 34-35
  • 7
    • 84868128391 scopus 로고    scopus 로고
    • 3-Amidocoumarins as chemodosimeters to trap cyanide through both Michael and intramolecular cyclization reaction
    • Sun Y., Wang Y., Cao D., Chen H., Liu Z., Fang Q. 3-Amidocoumarins as chemodosimeters to trap cyanide through both Michael and intramolecular cyclization reaction. Sensors Actuators B Chem. 2012, 174:500-505.
    • (2012) Sensors Actuators B Chem. , vol.174 , pp. 500-505
    • Sun, Y.1    Wang, Y.2    Cao, D.3    Chen, H.4    Liu, Z.5    Fang, Q.6
  • 8
    • 18044361879 scopus 로고
    • Process for determining the amount of hydrocyanic acid in medical prussic acid, bitter almond water, and laurel water
    • Liebig J. Process for determining the amount of hydrocyanic acid in medical prussic acid, bitter almond water, and laurel water. Q. J. Chem. Soc. Lond. 1852, 4:219-221.
    • (1852) Q. J. Chem. Soc. Lond. , vol.4 , pp. 219-221
    • Liebig, J.1
  • 9
    • 0020547657 scopus 로고
    • A critical evaluation of methods applicable to the determination of cyanides
    • Pohlandt C., Jones E.A., Lee A.F. A critical evaluation of methods applicable to the determination of cyanides. J. South. Afr. Inst. Min. Metall. 1983, 83:11-19.
    • (1983) J. South. Afr. Inst. Min. Metall. , vol.83 , pp. 11-19
    • Pohlandt, C.1    Jones, E.A.2    Lee, A.F.3
  • 10
    • 0016073953 scopus 로고
    • Sensitive gas chromatographic determination of cyanide
    • Valentour J.C., Aggarwal V., Sunshine I. Sensitive gas chromatographic determination of cyanide. Anal. Chem. 1974, 46:924-925.
    • (1974) Anal. Chem. , vol.46 , pp. 924-925
    • Valentour, J.C.1    Aggarwal, V.2    Sunshine, I.3
  • 11
    • 4243658890 scopus 로고
    • Indirect atomic absorption spectrometric methods for the determination of cyanide
    • Danchik R.S., Boltz D.F. Indirect atomic absorption spectrometric methods for the determination of cyanide. Anal. Chim. Acta. 1970, 49:567-569.
    • (1970) Anal. Chim. Acta. , vol.49 , pp. 567-569
    • Danchik, R.S.1    Boltz, D.F.2
  • 12
    • 0031727808 scopus 로고    scopus 로고
    • Determination of cyanide by a flow injection analysis-atomic absorption spectrometric method
    • Gomez A.V.L., Calatayud J.M. Determination of cyanide by a flow injection analysis-atomic absorption spectrometric method. Analyst 1998, 123:2103-2107.
    • (1998) Analyst , vol.123 , pp. 2103-2107
    • Gomez, A.V.L.1    Calatayud, J.M.2
  • 13
    • 31044455163 scopus 로고    scopus 로고
    • Enzyme inhibition-based biosensors for food safety and environmental monitoring
    • Amine A., Mohammadi H., Bourais I., Palleschi G. Enzyme inhibition-based biosensors for food safety and environmental monitoring. Biosens. Bioelectron. 2006, 21:1405-1423.
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1405-1423
    • Amine, A.1    Mohammadi, H.2    Bourais, I.3    Palleschi, G.4
  • 14
    • 84860519497 scopus 로고    scopus 로고
    • Amperometric sulfide detection using Coprinus cinereus peroxidase immobilized on screen printed electrode in an enzyme inhibition based biosensor
    • Savizi I.S.P., Kariminia H.-R., Ghadiri M., Roosta-Azad R. Amperometric sulfide detection using Coprinus cinereus peroxidase immobilized on screen printed electrode in an enzyme inhibition based biosensor. Biosens. Bioelectron. 2012, 35:297-301.
    • (2012) Biosens. Bioelectron. , vol.35 , pp. 297-301
    • Savizi, I.S.P.1    Kariminia, H.-R.2    Ghadiri, M.3    Roosta-Azad, R.4
  • 15
    • 4344697837 scopus 로고    scopus 로고
    • An amperometric horseradish peroxidase inhibition biosensor based on a cysteamine self-assembled monolayer for the determination of sulfides
    • Yang Y., Yang M., Wang H., Jiang J., Shen G., Yu R. An amperometric horseradish peroxidase inhibition biosensor based on a cysteamine self-assembled monolayer for the determination of sulfides. Sensors Actuators B 2004, 102:162-168.
    • (2004) Sensors Actuators B , vol.102 , pp. 162-168
    • Yang, Y.1    Yang, M.2    Wang, H.3    Jiang, J.4    Shen, G.5    Yu, R.6
  • 16
    • 0001247840 scopus 로고
    • Cyanide determination using an amperometric biosensor based on cytochrome oxidase inhibition
    • Amine A., Alfandy M., Kauffmann J., Pekli M.N. Cyanide determination using an amperometric biosensor based on cytochrome oxidase inhibition. Anal. Chem. 1995, 67:2822-2827.
    • (1995) Anal. Chem. , vol.67 , pp. 2822-2827
    • Amine, A.1    Alfandy, M.2    Kauffmann, J.3    Pekli, M.N.4
  • 17
    • 0027320797 scopus 로고
    • Detection of heavy metal salts with biosensors built with an oxygen electrode coupled to various immobilized oxidases and dehydrogenases
    • Gayet J.C., Haouz A., Geloso-Meyer A., Burstein C. Detection of heavy metal salts with biosensors built with an oxygen electrode coupled to various immobilized oxidases and dehydrogenases. Biosens. Bioelectron. 1993, 8:177-183.
    • (1993) Biosens. Bioelectron. , vol.8 , pp. 177-183
    • Gayet, J.C.1    Haouz, A.2    Geloso-Meyer, A.3    Burstein, C.4
  • 18
    • 79960305570 scopus 로고    scopus 로고
    • An amperometric biosensor based on acetylcholinesterase immobilized onto iron oxide nanoparticles/multi-walled carbon nanotubes modified gold electrode for measurement of organophosphorus insecticides
    • Chauhan N., Pundir C.S. An amperometric biosensor based on acetylcholinesterase immobilized onto iron oxide nanoparticles/multi-walled carbon nanotubes modified gold electrode for measurement of organophosphorus insecticides. Anal. Chim. Acta. 2011, 701:66-74.
    • (2011) Anal. Chim. Acta. , vol.701 , pp. 66-74
    • Chauhan, N.1    Pundir, C.S.2
  • 19
    • 78650169966 scopus 로고    scopus 로고
    • Impedance spectroscopy and conductometric biosensing for probing catalase reaction with cyanide as ligand and inhibitor
    • Bouyahia N., Hamlaoui M.L., Hnaien M., Lagarde F., J-Renault N. Impedance spectroscopy and conductometric biosensing for probing catalase reaction with cyanide as ligand and inhibitor. Bioelectrochemistry 2011, 80:155-161.
    • (2011) Bioelectrochemistry , vol.80 , pp. 155-161
    • Bouyahia, N.1    Hamlaoui, M.L.2    Hnaien, M.3    Lagarde, F.4    J-Renault, N.5
  • 20
    • 84867093710 scopus 로고    scopus 로고
    • A novel amperometric phenol biosensor based on immobilized HRP on poly(glycidylmethacrylate)-grafted iron oxide nanoparticles for the determination of phenol derivatives
    • Cevik E., Senel M., Baykal A., Abasiyanika M.F. A novel amperometric phenol biosensor based on immobilized HRP on poly(glycidylmethacrylate)-grafted iron oxide nanoparticles for the determination of phenol derivatives. Sensors Actuators B 2012, 173:396-405.
    • (2012) Sensors Actuators B , vol.173 , pp. 396-405
    • Cevik, E.1    Senel, M.2    Baykal, A.3    Abasiyanika, M.F.4
  • 22
    • 62949101956 scopus 로고    scopus 로고
    • Amperometric hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase by carbon-coated iron nanoparticles in combination with chitosan and cross-linking of gluteraldehyde
    • Lai G.S., Zhang H.L., Han D.Y. Amperometric hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase by carbon-coated iron nanoparticles in combination with chitosan and cross-linking of gluteraldehyde. Microchim. Acta 2009, 165:159-165.
    • (2009) Microchim. Acta , vol.165 , pp. 159-165
    • Lai, G.S.1    Zhang, H.L.2    Han, D.Y.3
  • 23
    • 84856263196 scopus 로고    scopus 로고
    • Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    • Wang Q., Zhang H., Wu Y., Yu A. Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles. Microchim. Acta 2012, 176:279-285.
    • (2012) Microchim. Acta , vol.176 , pp. 279-285
    • Wang, Q.1    Zhang, H.2    Wu, Y.3    Yu, A.4
  • 24
    • 84893056374 scopus 로고    scopus 로고
    • Glucose biosensor based on immobilization of glucose oxidase in electropolymerized poly(o-phenylenediamine) film on platinum nanoparticles-polyvinylferrocenium modified electrode
    • Turkmen E., Bas S.Z., Gulce H., Yildiz S. Glucose biosensor based on immobilization of glucose oxidase in electropolymerized poly(o-phenylenediamine) film on platinum nanoparticles-polyvinylferrocenium modified electrode. Electrochim. Acta 2014, 123:93-102.
    • (2014) Electrochim. Acta , vol.123 , pp. 93-102
    • Turkmen, E.1    Bas, S.Z.2    Gulce, H.3    Yildiz, S.4
  • 25
    • 84907329269 scopus 로고    scopus 로고
    • Materiales compuestos Sonogel-Carbono y Sonogel-Carbono modificados, un procedimiento para su preparación y su aplicación a la fabricación de electrodos y sensores amperométricos, Patent number ES-2195715-B1, Spain (2001).
    • J.L. Hidalgo-Hidalgo de Cisneros, M.M. Cordero-Rando, I. Naranjo-Rodríguez, E. Blanco-Ollero, L. Esquivias-Fedriani, Materiales compuestos Sonogel-Carbono y Sonogel-Carbono modificados, un procedimiento para su preparación y su aplicación a la fabricación de electrodos y sensores amperométricos, Patent number ES-2195715-B1, Spain (2001).
    • Hidalgo-Hidalgo de Cisneros, J.L.1    Cordero-Rando, M.M.2    Naranjo-Rodríguez, I.3    Blanco-Ollero, E.4    Esquivias-Fedriani, L.5
  • 29
    • 0141791155 scopus 로고    scopus 로고
    • Modified electrode approaches for nitric oxide sensing
    • Casero E., Losada J., Pariente F., Lorenzo E. Modified electrode approaches for nitric oxide sensing. Talanta 2003, 61:61/70.
    • (2003) Talanta , vol.61
    • Casero, E.1    Losada, J.2    Pariente, F.3    Lorenzo, E.4
  • 30
    • 33749508442 scopus 로고    scopus 로고
    • A strategy for enzyme immobilization on layer-by-layer dendrimer-gold nanoparticle electrocatalytic membrane incorporating redox mediator
    • Crespilho F.N., Ghica M.E., Florescu M., Nart F.C., Oliveira O.N., Brett C.M.A. A strategy for enzyme immobilization on layer-by-layer dendrimer-gold nanoparticle electrocatalytic membrane incorporating redox mediator. Electrochem. Commun. 2006, 8:1665-1670.
    • (2006) Electrochem. Commun. , vol.8 , pp. 1665-1670
    • Crespilho, F.N.1    Ghica, M.E.2    Florescu, M.3    Nart, F.C.4    Oliveira, O.N.5    Brett, C.M.A.6
  • 31
    • 0034275903 scopus 로고    scopus 로고
    • Configurations used in the design of screen-printed enzymatic biosensors. A review
    • Albareda-Sirvent M., Merkoçi A., Alegret S. Configurations used in the design of screen-printed enzymatic biosensors. A review. Sensors Actuators B 2000, 69:153-163.
    • (2000) Sensors Actuators B , vol.69 , pp. 153-163
    • Albareda-Sirvent, M.1    Merkoçi, A.2    Alegret, S.3
  • 32
    • 84972939218 scopus 로고
    • Comparative studies of immobilized enzyme electrodes based on the inhibitory effect of nicotine on choline oxidase and acetylcholinesterase
    • Nwosu T.N., Palleschi G., Mascini M. Comparative studies of immobilized enzyme electrodes based on the inhibitory effect of nicotine on choline oxidase and acetylcholinesterase. Anal. Lett. 1992, 25(5):821-835.
    • (1992) Anal. Lett. , vol.25 , Issue.5 , pp. 821-835
    • Nwosu, T.N.1    Palleschi, G.2    Mascini, M.3
  • 33
    • 0742324902 scopus 로고    scopus 로고
    • Horseradish peroxidase: a modern view of a classic enzyme
    • Vietch N.C. Horseradish peroxidase: a modern view of a classic enzyme. Phytochemistry 2004, 65:249-259.
    • (2004) Phytochemistry , vol.65 , pp. 249-259
    • Vietch, N.C.1
  • 35
    • 0035946445 scopus 로고    scopus 로고
    • Acetylcholine enzyme sensor for determining methamidophos insecticide evaluation of some genetically modified acetylcholinesterases from drosophila melanogaster
    • Nunes G.S., Montesinos T., Marques P.B.O., Fournier D., Marty J.L. Acetylcholine enzyme sensor for determining methamidophos insecticide evaluation of some genetically modified acetylcholinesterases from drosophila melanogaster. Anal. Chim. Acta. 2001, 434:1-8.
    • (2001) Anal. Chim. Acta. , vol.434 , pp. 1-8
    • Nunes, G.S.1    Montesinos, T.2    Marques, P.B.O.3    Fournier, D.4    Marty, J.L.5
  • 36
    • 77954145904 scopus 로고    scopus 로고
    • Amperometric sensor for cyanide utilizing cyanidase and formate dehydrogenase
    • Ketterer L., Keusgen M. Amperometric sensor for cyanide utilizing cyanidase and formate dehydrogenase. Anal. Chim. Acta. 2010, 673:54-59.
    • (2010) Anal. Chim. Acta. , vol.673 , pp. 54-59
    • Ketterer, L.1    Keusgen, M.2
  • 37
    • 0032532724 scopus 로고    scopus 로고
    • Cyanide determination by an ISFET-based peroxidase biosensor
    • Volotovsky V., Kim N. Cyanide determination by an ISFET-based peroxidase biosensor. Biosens. Bioelectron. 1998, 13:1029-1033.
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 1029-1033
    • Volotovsky, V.1    Kim, N.2
  • 38
    • 77049143386 scopus 로고
    • The determination of enzyme inhibitor constants
    • Dixon M. The determination of enzyme inhibitor constants. Biochem. J. 1953, 55:170-171.
    • (1953) Biochem. J. , vol.55 , pp. 170-171
    • Dixon, M.1
  • 41
    • 4043121664 scopus 로고    scopus 로고
    • HRP/[Zn-Cr-ABTS] redox clay-based biosensor: design and optimization of cyanide detection
    • Shan D., Cosnier S., Mousty C. HRP/[Zn-Cr-ABTS] redox clay-based biosensor: design and optimization of cyanide detection. Biosens. Bioelectron. 2004, 20:390-396.
    • (2004) Biosens. Bioelectron. , vol.20 , pp. 390-396
    • Shan, D.1    Cosnier, S.2    Mousty, C.3
  • 42
    • 0347361592 scopus 로고    scopus 로고
    • Subnanomolar cyanide detection at polyphenol oxidase/clay biosensors
    • Shan D., Mousty C., Cosnier S. Subnanomolar cyanide detection at polyphenol oxidase/clay biosensors. Anal. Chem. 2004, 76:178-183.
    • (2004) Anal. Chem. , vol.76 , pp. 178-183
    • Shan, D.1    Mousty, C.2    Cosnier, S.3
  • 43
    • 77954216524 scopus 로고    scopus 로고
    • Recent developments in cyanide detection: a review
    • Ma J., Dasgupta P.K. Recent developments in cyanide detection: a review. Anal. Chim. Acta. 2010, 673:117-125.
    • (2010) Anal. Chim. Acta. , vol.673 , pp. 117-125
    • Ma, J.1    Dasgupta, P.K.2
  • 44
    • 0000586315 scopus 로고    scopus 로고
    • Renewable-reagent enzyme inhibition sensor for remote monitoring of cyanide
    • Wang J., Tian B., Lu J., MacDonald D., Wang J., Luo D. Renewable-reagent enzyme inhibition sensor for remote monitoring of cyanide. Electroanalysis 1998, 10:1034-1037.
    • (1998) Electroanalysis , vol.10 , pp. 1034-1037
    • Wang, J.1    Tian, B.2    Lu, J.3    MacDonald, D.4    Wang, J.5    Luo, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.