메뉴 건너뛰기




Volumn 438, Issue , 2014, Pages 157-159

Simultaneous measurement of testosterone, androstenedione and dehydroepiandrosterone (DHEA) in serum and plasma using isotope-dilution 2-dimension ultra high performance liquid-chromatography tandem mass spectrometry (ID-LC-MS/MS)

Author keywords

Androgens; Androstenedione; Dehydroepiandrosterone (DHEA); Liquid chromatography; Mass spectrometry; Testosterone

Indexed keywords

ANDROSTENEDIONE; PRASTERONE; TESTOSTERONE;

EID: 84907178057     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2014.08.023     Document Type: Article
Times cited : (38)

References (8)
  • 2
    • 2442513258 scopus 로고    scopus 로고
    • Steroid hormones: relevance and measurement in the clinical laboratory
    • Holst J.P., Soldin O.P., Guo T., Soldin S.J. Steroid hormones: relevance and measurement in the clinical laboratory. Clin Lab Med 2004, 24(1):105-118.
    • (2004) Clin Lab Med , vol.24 , Issue.1 , pp. 105-118
    • Holst, J.P.1    Soldin, O.P.2    Guo, T.3    Soldin, S.J.4
  • 3
    • 0042868816 scopus 로고    scopus 로고
    • Testosterone measured by 10 immunoassays and by isotope-dilution gas chromatography-mass spectrometry in sera from 116 men, women, and children
    • Taieb J., Mathian B., Millot F., et al. Testosterone measured by 10 immunoassays and by isotope-dilution gas chromatography-mass spectrometry in sera from 116 men, women, and children. Clin Chem 2003, 49(8):1381-1395.
    • (2003) Clin Chem , vol.49 , Issue.8 , pp. 1381-1395
    • Taieb, J.1    Mathian, B.2    Millot, F.3
  • 4
    • 0041866807 scopus 로고    scopus 로고
    • Immunoassays for testosterone in women: better than a guess?
    • Herold D.A., Fitzgerald R.L. Immunoassays for testosterone in women: better than a guess?. Clin Chem 2003, 49(8):1250-1251.
    • (2003) Clin Chem , vol.49 , Issue.8 , pp. 1250-1251
    • Herold, D.A.1    Fitzgerald, R.L.2
  • 5
    • 78751642492 scopus 로고    scopus 로고
    • Serum steroid profiling by isotopic dilution-liquid chromatography-mass spectrometry: comparison with current immunoassays and reference intervals in healthy adults
    • Fanelli F., Belluomo I., Di Lallo V.D., et al. Serum steroid profiling by isotopic dilution-liquid chromatography-mass spectrometry: comparison with current immunoassays and reference intervals in healthy adults. Steroids 2011, 76(3):244-253.
    • (2011) Steroids , vol.76 , Issue.3 , pp. 244-253
    • Fanelli, F.1    Belluomo, I.2    Di Lallo, V.D.3
  • 6
    • 84890939752 scopus 로고    scopus 로고
    • LC-MS/MS in endocrinology: what is the profit of the last 5years?
    • Ackermans M.T., Endert E. LC-MS/MS in endocrinology: what is the profit of the last 5years?. Bioanalysis 2014, 6(1):43-57.
    • (2014) Bioanalysis , vol.6 , Issue.1 , pp. 43-57
    • Ackermans, M.T.1    Endert, E.2
  • 7
    • 84869863293 scopus 로고    scopus 로고
    • Dynamics of serum testosterone during the menstrual cycle evaluated by daily measurements with an ID-LC-MS/MS method and a 2nd generation automated immunoassay
    • Bui H.N., Sluss P.M., Blincko S., et al. Dynamics of serum testosterone during the menstrual cycle evaluated by daily measurements with an ID-LC-MS/MS method and a 2nd generation automated immunoassay. Steroids 2013, 78(1):96-101.
    • (2013) Steroids , vol.78 , Issue.1 , pp. 96-101
    • Bui, H.N.1    Sluss, P.M.2    Blincko, S.3
  • 8
    • 77954370695 scopus 로고    scopus 로고
    • Liquid chromatography-tandem mass spectrometry assay for androstenedione, dehydroepiandrosterone, and testosterone with pediatric and adult reference intervals
    • Kushnir M.M., Blamires T., Rockwood A.L., et al. Liquid chromatography-tandem mass spectrometry assay for androstenedione, dehydroepiandrosterone, and testosterone with pediatric and adult reference intervals. Clin Chem 2010, 56(7):1138-1147.
    • (2010) Clin Chem , vol.56 , Issue.7 , pp. 1138-1147
    • Kushnir, M.M.1    Blamires, T.2    Rockwood, A.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.