Volumn 35, Issue 9, 2014, Pages 1740-1745

A novel technique for the measurement of CBF and CBV with robot-arm-mounted flat panel CT in a large-animal model

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BRAIN BLOOD FLOW; BRAIN BLOOD VOLUME; BRAIN ISCHEMIA; BRAIN PERFUSION; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; IMAGE ANALYSIS; INTERMETHOD COMPARISON; MEASUREMENT; NONHUMAN; ROBOTICS; SENSITIVITY AND SPECIFICITY; ANIMAL; BRAIN ANGIOGRAPHY; BRAIN CIRCULATION; CEREBRAL ARTERY DISEASE; CEREBROVASCULAR ACCIDENT; DISEASE MODEL; PHYSIOLOGY; PROCEDURES; RADIOGRAPHY; SCINTIGRAPHY; SHEEP;

EID: 84907101763     PISSN: 01956108     EISSN: 1936959X     Source Type: Journal    
DOI: 10.3174/ajnr.A3973     Document Type: Article
Times cited : (9)

References (27)
  • 1
    • 0028783948 scopus 로고
    • Tissue plasminogen activator for acute ischemic stroke: The National Institute of Neurological Disorders and Stroke rt-PA Stroke Study Group
    • Tissue plasminogen activator for acute ischemic stroke: the National Institute of Neurological Disorders and Stroke rt-PA Stroke Study Group. N Engl J Med 1995;333:1581-87
    • (1995) N Engl J Med , vol.333 , pp. 1581-1587
  • 2
    • 77952112006 scopus 로고    scopus 로고
    • Time to treatment with intravenous alteplase and outcome in stroke: An updated pooled analysis of ECASS, ATLANTIS, NINDS, and EPITHET trials
    • Lees KR, Bluhmki E, von Kummer R, et al. Time to treatment with intravenous alteplase and outcome in stroke: an updated pooled analysis of ECASS, ATLANTIS, NINDS, and EPITHET trials. Lancet 2010;375:1695-703
    • (2010) Lancet , vol.375 , pp. 1695-1703
    • Lees, K.R.1    Bluhmki, E.2    Von Kummer, R.3
  • 3
    • 84862625338 scopus 로고    scopus 로고
    • The benefits and harms of intravenous thrombolysis with recombinant tissue plasminogen activator within 6 h of acute ischaemic stroke (the third International Stroke Trial [IST-3]): A randomised controlled trial
    • Sandercock P, Wardlaw JM, Lindley RI, et al. The benefits and harms of intravenous thrombolysis with recombinant tissue plasminogen activator within 6 h of acute ischaemic stroke (the third International Stroke Trial [IST-3]): a randomised controlled trial. Lancet 2012;379:2352-63
    • (2012) Lancet , vol.379 , pp. 2352-2363
    • Sandercock, P.1    Wardlaw, J.M.2    Lindley, R.I.3
  • 4
    • 39349118016 scopus 로고    scopus 로고
    • Comparison of intraarterial and intravenous thrombolysis for ischemic stroke with hyperdense middle cerebral artery sign
    • Mattle HP, Arnold M, Georgiadis D, et al. Comparison of intraarterial and intravenous thrombolysis for ischemic stroke with hyperdense middle cerebral artery sign. Stroke 2008;39:379-83
    • (2008) Stroke , vol.39 , pp. 379-383
    • Mattle, H.P.1    Arnold, M.2    Georgiadis, D.3
  • 5
    • 68249091754 scopus 로고    scopus 로고
    • The Penumbra Pivotal Stroke Trial: Safety and effectiveness of a new generation of mechanical devices for clot removal in intracranial large vessel occlusive disease
    • Penumbra Pivotal Stroke Trial Investigators. The Penumbra Pivotal Stroke Trial: safety and effectiveness of a new generation of mechanical devices for clot removal in intracranial large vessel occlusive disease. Stroke 2009;40:2761-68
    • (2009) Stroke , vol.40 , pp. 2761-2768
  • 6
    • 84866531137 scopus 로고    scopus 로고
    • Retrospective multicenter study of Solitaire FR for revascularization in the treatment of acute ischemic stroke
    • Dávalos A, Pereira VM, Chapot R, et al. Retrospective multicenter study of Solitaire FR for revascularization in the treatment of acute ischemic stroke. Stroke 2012;43:2699-705
    • (2012) Stroke , vol.43 , pp. 2699-2705
    • Dávalos, A.1    Pereira, V.M.2    Chapot, R.3
  • 7
    • 84867064449 scopus 로고    scopus 로고
    • Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): A randomised trial
    • Nogueira RG, Lutsep HL, Gupta R, et al. Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): a randomised trial. Lancet 2012;380:1231-40
    • (2012) Lancet , vol.380 , pp. 1231-1240
    • Nogueira, R.G.1    Lutsep, H.L.2    Gupta, R.3
  • 8
    • 84867072741 scopus 로고    scopus 로고
    • Solitaire flow restoration device versus the Merci retriever in patients with acute ischaemic stroke (SWIFT): A randomised, parallel-group, non-inferiority trial
    • Saver JL, Jahan R, Levy EI, et al. Solitaire flow restoration device versus the Merci retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trial. Lancet 2012;380:1241-49
    • (2012) Lancet , vol.380 , pp. 1241-1249
    • Saver, J.L.1    Jahan, R.2    Levy, E.I.3
  • 9
    • 84871693262 scopus 로고    scopus 로고
    • Perfusion imaging of acute stroke: Its role in current and future clinical practice
    • Lev MH. Perfusion imaging of acute stroke: its role in current and future clinical practice. Radiology 2013;266:22-27
    • (2013) Radiology , vol.266 , pp. 22-27
    • Lev, M.H.1
  • 10
    • 84860242656 scopus 로고    scopus 로고
    • Feasibility of cerebral blood volume mapping by flat panel detector CT in the angiography suite: First experience in patients with acute middle cerebral artery occlusions
    • Struffert T, Deuerling-Zheng Y, Engelhorn T, et al. Feasibility of cerebral blood volume mapping by flat panel detector CT in the angiography suite: first experience in patients with acute middle cerebral artery occlusions. AJNR Am J Neuroradiol 2012;33:618-25
    • (2012) AJNR Am J Neuroradiol , vol.33 , pp. 618-625
    • Struffert, T.1    Deuerling-Zheng, Y.2    Engelhorn, T.3
  • 11
    • 79954611497 scopus 로고    scopus 로고
    • Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT
    • Struffert T, Deuerling-Zheng Y, Kloska S, et al. Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT. Eur Radiol 2011;21:882-89
    • (2011) Eur Radiol , vol.21 , pp. 882-889
    • Struffert, T.1    Deuerling-Zheng, Y.2    Kloska, S.3
  • 12
    • 77949494246 scopus 로고    scopus 로고
    • C-arm CT measurement of cerebral blood volume in ischemic stroke: An experimental study in canines
    • Bley T, Strother CM, Pulfer K, et al. C-arm CT measurement of cerebral blood volume in ischemic stroke: an experimental study in canines. AJNR Am J Neuroradiol 2010;31:536-40
    • (2010) AJNR Am J Neuroradiol , vol.31 , pp. 536-540
    • Bley, T.1    Strother, C.M.2    Pulfer, K.3
  • 13
    • 80052927983 scopus 로고    scopus 로고
    • Cerebral CT perfusion using an interventional C-arm imaging system: Cerebral blood flow measurements
    • Ganguly A, Fieselmann A, Marks M, et al. Cerebral CT perfusion using an interventional C-arm imaging system: cerebral blood flow measurements. AJNR Am J Neuroradiol 2011;32:1525-31
    • (2011) AJNR Am J Neuroradiol , vol.32 , pp. 1525-1531
    • Ganguly, A.1    Fieselmann, A.2    Marks, M.3
  • 14
    • 84888166519 scopus 로고    scopus 로고
    • C-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection
    • Royalty K, Manhart M, Pulfer K, et al. C-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection. AJNR Am J Neuroradiol 2013;34:2131-38
    • (2013) AJNR Am J Neuroradiol , vol.34 , pp. 2131-2138
    • Royalty, K.1    Manhart, M.2    Pulfer, K.3
  • 15
    • 56649106560 scopus 로고    scopus 로고
    • Permanent middle cerebral artery occlusion in sheep: A novel large animal model of focal cerebral ischemia
    • Boltze J, Forschler A, Nitzsche B, et al. Permanent middle cerebral artery occlusion in sheep: a novel large animal model of focal cerebral ischemia. J Cereb Blood Flow Metab 2008;28:1951-64
    • (2008) J Cereb Blood Flow Metab , vol.28 , pp. 1951-1964
    • Boltze, J.1    Forschler, A.2    Nitzsche, B.3
  • 16
    • 79958105229 scopus 로고    scopus 로고
    • A model for filtered backprojection reconstruction artifacts due to time-varying attenuation values in perfusion C-arm CT
    • Fieselmann A, Dennerlein F, Deuerling-Zheng Y, et al. A model for filtered backprojection reconstruction artifacts due to time-varying attenuation values in perfusion C-arm CT. Phys Med Biol 2011;56:3701-17
    • (2011) Phys Med Biol , vol.56 , pp. 3701-3717
    • Fieselmann, A.1    Dennerlein, F.2    Deuerling-Zheng, Y.3
  • 17
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159-74
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 18
    • 77956399307 scopus 로고    scopus 로고
    • Endovascular treatment of acute ischemic stroke may be safely performed with no time window limit in appropriately selected patients
    • Abou-Chebl A. Endovascular treatment of acute ischemic stroke may be safely performed with no time window limit in appropriately selected patients. Stroke 2010;41:1996-2000
    • (2010) Stroke , vol.41 , pp. 1996-2000
    • Abou-Chebl, A.1
  • 19
    • 84863003253 scopus 로고    scopus 로고
    • CT perfusion-guided patient selection for endovascular treatment of acute ischemic stroke is safe and effective
    • Turk A, Magarik JA, Chaudry I, et al. CT perfusion-guided patient selection for endovascular treatment of acute ischemic stroke is safe and effective. J Neurointerv Surg 2012;4:261-65
    • (2012) J Neurointerv Surg , vol.4 , pp. 261-265
    • Turk, A.1    Magarik, J.A.2    Chaudry, I.3
  • 20
    • 78650254107 scopus 로고    scopus 로고
    • Defining the extent of irreversible brain ischemia using perfusion computed tomography
    • Bivard A, McElduff P, Spratt N, et al. Defining the extent of irreversible brain ischemia using perfusion computed tomography. Cerebrovasc Dis 2011;31:238-45
    • (2011) Cerebrovasc Dis , vol.31 , pp. 238-245
    • Bivard, A.1    McElduff, P.2    Spratt, N.3
  • 21
    • 84861700829 scopus 로고    scopus 로고
    • Perfusion/diffusion mismatch is valid and should be used for selecting delayed interventions
    • Davis S, Campbell B, Christensen S, et al. Perfusion/diffusion mismatch is valid and should be used for selecting delayed interventions. Transl Stroke Res 2012;3:188-97
    • (2012) Transl Stroke Res , vol.3 , pp. 188-197
    • Davis, S.1    Campbell, B.2    Christensen, S.3
  • 22
    • 79959946747 scopus 로고    scopus 로고
    • CT cerebral blood flow maps optimally correlate with admission diffusion-weighted imaging in acute stroke but thresholds vary by postprocessing platform
    • Kamalian S, Maas MB, Goldmacher GV, et al. CT cerebral blood flow maps optimally correlate with admission diffusion-weighted imaging in acute stroke but thresholds vary by postprocessing platform. Stroke 2011;42:1923-28
    • (2011) Stroke , vol.42 , pp. 1923-1928
    • Kamalian, S.1    Maas, M.B.2    Goldmacher, G.V.3
  • 23
    • 77957826451 scopus 로고    scopus 로고
    • Clinical evaluation of flat-panel detector compared with multislice computed tomography in 65 patients with acute intracranial hemorrhage: Initial results: Clinical article
    • Struffert T, Eyupoglu IY, Huttner HB, et al. Clinical evaluation of flat-panel detector compared with multislice computed tomography in 65 patients with acute intracranial hemorrhage: initial results: clinical article. J Neurosurg 2010;113:901-07
    • (2010) J Neurosurg , vol.113 , pp. 901-907
    • Struffert, T.1    Eyupoglu, I.Y.2    Huttner, H.B.3
  • 24
    • 84862890890 scopus 로고    scopus 로고
    • Intravenous flat-detector CT angiography in acute ischemic stroke management
    • Blanc R, Pistocchi S, Babic D, et al. Intravenous flat-detector CT angiography in acute ischemic stroke management. Neuroradiology 2012;54:383-91
    • (2012) Neuroradiology , vol.54 , pp. 383-391
    • Blanc, R.1    Pistocchi, S.2    Babic, D.3
  • 25
    • 84873616562 scopus 로고    scopus 로고
    • Feasibility of intravenous flat panel detector CT angiography for intracranial arterial stenosis
    • Jeon JS, Sheen SH, Hwang GJ, et al. Feasibility of intravenous flat panel detector CT angiography for intracranial arterial stenosis. AJNR Am J Neuroradiol 2013;34:129-34
    • (2013) AJNR Am J Neuroradiol , vol.34 , pp. 129-134
    • Jeon, J.S.1    Sheen, S.H.2    Hwang, G.J.3
  • 26
    • 44649173125 scopus 로고    scopus 로고
    • Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: Preliminary results compared to conventional CT
    • Doelken M, Struffert T, Richter G, et al. Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT. Neuroradiology 2008;50:517-23
    • (2008) Neuroradiology , vol.50 , pp. 517-523
    • Doelken, M.1    Struffert, T.2    Richter, G.3
  • 27
    • 64649092845 scopus 로고    scopus 로고
    • Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke. Part 1. Theoretic basis
    • Konstas AA, Goldmakher GV, Lee TY, et al. Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke. Part 1. Theoretic basis. AJNR Am J Neuroradiol 2009;30:662-68
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 662-668
    • Konstas, A.A.1    Goldmakher, G.V.2    Lee, T.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.