메뉴 건너뛰기




Volumn 60, Issue 5, 2014, Pages 508-512

Insensible water loss through adult extracorporeal membrane oxygenation circuit: An in vitro study

Author keywords

Critical care; Extracorporeal membrane oxygenation circuit; Insensible water loss

Indexed keywords

FLOW OF GASES; FLOW RATE; LINEAR REGRESSION; OXYGENATION; OXYGENATORS; RESPIRATORY THERAPY;

EID: 84907018117     PISSN: 10582916     EISSN: 1538943X     Source Type: Journal    
DOI: 10.1097/MAT.0000000000000098     Document Type: Article
Times cited : (9)

References (11)
  • 1
    • 0023701091 scopus 로고
    • Prolonged extracorporeal membrane oxygenation in sheep with a hollow-fiber oxygenator and a centrifugal pump
    • Palder SB, Shaheen KW, Whittlesey GC, Nowlen TT, Kundu SK, Klein MD: Prolonged extracorporeal membrane oxygenation in sheep with a hollow-fiber oxygenator and a centrifugal pump. ASAIO Trans 34: 820-822, 1988.
    • (1988) ASAIO Trans , vol.34 , pp. 820-822
    • Palder, S.B.1    Shaheen, K.W.2    Whittlesey, G.C.3    Nowlen, T.T.4    Kundu, S.K.5    Klein, M.D.6
  • 2
    • 70350018319 scopus 로고    scopus 로고
    • Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): A multicentre randomised controlled trial
    • CESAR Trial Collaboration
    • Peek GJ, Mugford M, Tiruvoipati R, et al; CESAR Trial Collaboration: Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): A multicentre randomised controlled trial. Lancet 374: 1351-1363, 2009.
    • (2009) Lancet , vol.374 , pp. 1351-1363
    • Peek, G.J.1    Mugford, M.2    Tiruvoipati, R.3
  • 3
    • 47549084637 scopus 로고    scopus 로고
    • Insensible water loss from the Jostra Quadrox D oxygenator: An in vitro study
    • Lawson DS, Holt D: Insensible water loss from the Jostra Quadrox D oxygenator: An in vitro study. Perfusion 22: 407-410, 2007.
    • (2007) Perfusion , vol.22 , pp. 407-410
    • Lawson, D.S.1    Holt, D.2
  • 4
    • 0034282633 scopus 로고    scopus 로고
    • Insensible water loss during extracorporeal membrane oxygenation: An in vitro study
    • Camacho T, Totapally BR, Hultquist K, et al: Insensible water loss during extracorporeal membrane oxygenation: An in vitro study. ASAIO J 46: 620-624, 2000.
    • (2000) ASAIO J , vol.46 , pp. 620-624
    • Camacho, T.1    Totapally, B.R.2    Hultquist, K.3
  • 5
    • 33744981607 scopus 로고    scopus 로고
    • Insensible water loss from the medtronic minimax oxygenator: An in vitro study
    • Alexander PJ, Lawson DS, Cornell J, Craig DM, Cheifetz IM: Insensible water loss from the medtronic minimax oxygenator: An in vitro study. ASAIO J 52: 206-210, 2006.
    • (2006) ASAIO J , vol.52 , pp. 206-210
    • Alexander, P.J.1    Lawson, D.S.2    Cornell, J.3    Craig, D.M.4    Cheifetz, I.M.5
  • 7
    • 0007994306 scopus 로고
    • ECLS and fluids, electrolytes and renal function
    • Zwischenberger JB, Bartlett RH (eds), Ann Arbor, MI, ELSO
    • Heulitt MJ, Pickert CB: ECLS and fluids, electrolytes and renal function. in Zwischenberger JB, Bartlett RH (eds), ECMO. Extracorporeal Cardiopulmonary Support in Critical Care. Ann Arbor, MI, ELSO, 1995, pp. 123-135.
    • (1995) ECMO. Extracorporeal Cardiopulmonary Support in Critical Care , pp. 123-135
    • Heulitt, M.J.1    Pickert, C.B.2
  • 8
    • 84871551593 scopus 로고    scopus 로고
    • Insensible water loss from the Hilite 2400LT oxygenator: An in vitro study
    • Gill M, O'Shaughnessy K: Insensible water loss from the Hilite 2400LT oxygenator: An in vitro study. Perfusion 28: 70-75, 2013.
    • (2013) Perfusion , vol.28 , pp. 70-75
    • Gill, M.1    O'Shaughnessy, K.2
  • 9
    • 0031282286 scopus 로고    scopus 로고
    • A capillary method to measure water transmission through polyurethane membranes
    • Yang M, Deng X, Laroche G, Hahn C, King MW, Guidoin RG: A capillary method to measure water transmission through polyurethane membranes. ASAIO J 43: 890-896, 1997.
    • (1997) ASAIO J , vol.43 , pp. 890-896
    • Yang, M.1    Deng, X.2    Laroche, G.3    Hahn, C.4    King, M.W.5    Guidoin, R.G.6
  • 10
    • 79960279415 scopus 로고    scopus 로고
    • Clinical evaluation of two different extracorporeal membrane oxygenation systems: A single center report
    • Yu K, Long C, Hei F, et al: Clinical evaluation of two different extracorporeal membrane oxygenation systems: A single center report. Artif Organs 35: 733-737, 2011.
    • (2011) Artif Organs , vol.35 , pp. 733-737
    • Yu, K.1    Long, C.2    Hei, F.3
  • 11
    • 38349098665 scopus 로고    scopus 로고
    • Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock
    • Formica F, Avalli L, Martino A, et al: Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock. ASAIO J 54: 89-94, 2008.
    • (2008) ASAIO J , vol.54 , pp. 89-94
    • Formica, F.1    Avalli, L.2    Martino, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.