Evaluation of low-dose limits in 3D-2D rigid registration for surgical guidance

Author keywords

3D 2D registration; dose; image guided surgery; neurosurgery; surgical navigation; x ray fluoroscopy

Indexed keywords

ALGORITHM; COMPUTER ASSISTED SURGERY; CONE BEAM COMPUTED TOMOGRAPHY; EVALUATION STUDY; FLUOROSCOPY; HUMAN; IMAGE QUALITY; PROCEDURES; THREE DIMENSIONAL IMAGING;

EID: 84906902005     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/59/18/5329     Document Type: Article
Times cited : (17)

References (43)
  • 3
    • 34547909263 scopus 로고    scopus 로고
    • Comparison of accuracy and precision between frame-based and frameless stereotactic navigation for deep brain stimulation electrode implantation
    • DOI 10.1159/000103262
    • Bjartmarz H and Rehncrona S 2007 Comparison of accuracy and precision between frame-based and frameless stereotactic navigation for deep brain stimulation electrode implantation Stereotact. Funct. Neurosurg. 85 235-42 (Pubitemid 47254536)
    • (2007) Stereotactic and Functional Neurosurgery , vol.85 , Issue.5 , pp. 235-242
    • Bjartmarz, H.1    Rehncrona, S.2
  • 4
    • 77950569462 scopus 로고    scopus 로고
    • Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation
    • 10.1118/1.3366252 0094-2405
    • Van der Bom M J, Bartels L W, Gounis M J, Homan R, Timmer J, Viergever M A and Pluim J P W 2010 Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation Med. Phys. 37 1884-92
    • (2010) Med. Phys. , vol.37 , pp. 1884-1892
    • Van Der Bom, M.J.1    Bartels, L.W.2    Gounis, M.J.3    Homan, R.4    Timmer, J.5    Viergever, M.A.6    Pluim, J.P.W.7
  • 5
    • 42949122453 scopus 로고    scopus 로고
    • Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    • DOI 10.1118/1.2907563
    • Daly M J, Siewerdsen J H, Cho Y B, Jaffray D A and Irish J C 2008 Geometric calibration of a mobile C-arm for intraoperative cone-beam CT Med. Phys. 35 2124 (Pubitemid 351614827)
    • (2008) Medical Physics , vol.35 , Issue.5 , pp. 2124-2136
    • Daly, M.J.1    Siewerdsen, J.H.2    Cho, Y.B.3    Jaffray, D.A.4    Irish, J.C.5
  • 8
    • 70350136594 scopus 로고    scopus 로고
    • A comparative study on manual and automatic slice-to-volume registration of CT images
    • 10.1007/s00330-009-1452-0
    • Frühwald L, Kettenbach J, Figl M, Hummel J, Bergmann H and Birkfellner W 2009 A comparative study on manual and automatic slice-to-volume registration of CT images Eur. Radiol. 19 2647-53
    • (2009) Eur. Radiol. , vol.19 , pp. 2647-2653
    • Frühwald, L.1    Kettenbach, J.2    Figl, M.3    Hummel, J.4    Bergmann, H.5    Birkfellner, W.6
  • 9
    • 73149098916 scopus 로고    scopus 로고
    • Robust smoothing of gridded data in one and higher dimensions with missing values
    • 10.1016/j.csda.2009.09.020 0167-9473
    • Garcia D 2010 Robust smoothing of gridded data in one and higher dimensions with missing values Comput. Stat. Data Anal. 54 1167-78
    • (2010) Comput. Stat. Data Anal. , vol.54 , pp. 1167-1178
    • Garcia, D.1
  • 11
    • 59749085404 scopus 로고    scopus 로고
    • A method for handling uncertainty in evolutionary optimization with an application to feedback control of combustion
    • 10.1109/TEVC.2008.924423 1089-778X
    • Hansen N, Niederberger A S P, Guzzella L and Koumoutsakos P 2009 A method for handling uncertainty in evolutionary optimization with an application to feedback control of combustion IEEE Trans. Evol. Comput. 13 180-97
    • (2009) IEEE Trans. Evol. Comput. , vol.13 , pp. 180-197
    • Hansen, N.1    Niederberger, A.S.P.2    Guzzella, L.3    Koumoutsakos, P.4
  • 12
    • 84975553202 scopus 로고
    • Closed-form solution of absolute orientation using unit quaternions
    • 10.1364/JOSAA.4.000629 0740-3232 A
    • Horn B K P 1987 Closed-form solution of absolute orientation using unit quaternions J. Opt. Soc. Am. A 4 629
    • (1987) J. Opt. Soc. Am. , vol.4 , pp. 629
    • Horn, B.K.P.1
  • 13
    • 0000951235 scopus 로고    scopus 로고
    • Global Optimization by Multilevel Coordinate Search
    • Huyer W and Neumaier A 1999 Global optimization by multilevel coordinate search J. Glob. Optim. 14 331-55 (Pubitemid 129617300)
    • (1999) Journal of Global Optimization , vol.14 , Issue.4 , pp. 331-355
    • Huyer, W.1    Neumaier, A.2
  • 14
    • 84906908435 scopus 로고    scopus 로고
    • A novel technique for ventriculoperitoneal shunting by flat panel detector CT-guided real-time fluoroscopy
    • 10.4103/2152-7806.102330
    • Kobayashi S, Ishikawa T, Mutoh T, Hikichi K and Suzuki A 2012 A novel technique for ventriculoperitoneal shunting by flat panel detector CT-guided real-time fluoroscopy Surg. Neurol. Int. 3 119
    • (2012) Surg. Neurol. Int. , vol.3 , pp. 119
    • Kobayashi, S.1    Ishikawa, T.2    Mutoh, T.3    Hikichi, K.4    Suzuki, A.5
  • 15
    • 84865657606 scopus 로고    scopus 로고
    • Intraoperative C-arm cone-beam computed tomography: Quantitative analysis of surgical performance in skull base surgery
    • 10.1002/lary.23374
    • Lee S et al 2012 Intraoperative C-arm cone-beam computed tomography: quantitative analysis of surgical performance in skull base surgery Laryngoscope 122 1925-32
    • (2012) Laryngoscope , vol.122 , pp. 1925-1932
    • Lee, S.1
  • 17
    • 0033808915 scopus 로고    scopus 로고
    • Intraoperative magnetic resonance image guidance in neurosurgery
    • 10.1023/A:1008382309369
    • Lewin J S, Metzeger A and Selman W R 2000 Intraoperative magnetic resonance image guidance in neurosurgery J. Mag. Reson. Imaging 12 512-24
    • (2000) J. Mag. Reson. Imaging , vol.12 , pp. 512-524
    • Lewin, J.S.1    Metzeger, A.2    Selman, W.R.3
  • 18
    • 0035403070 scopus 로고    scopus 로고
    • Fluoroscopy: Patient radiation exposure issues
    • 10.1148/radiographics.21.4.g01jl271033
    • Mahesh M 2001 Fluoroscopy: patient radiation exposure issues Radiographics 21 1033-45
    • (2001) Radiographics , vol.21 , pp. 1033-1045
    • Mahesh, M.1
  • 19
    • 84857628623 scopus 로고    scopus 로고
    • A review of 3D/2D registration methods for image-guided interventions
    • 10.1016/j.media.2010.03.005
    • Markelj P, Tomaževič D, Likar B and Pernuš F 2012 A review of 3D/2D registration methods for image-guided interventions Med. Image Anal. 16 642-61
    • (2012) Med. Image Anal. , vol.16 , pp. 642-661
    • Markelj, P.1    Tomaževič, D.2    Likar, B.3    Pernuš, F.4
  • 21
    • 84948796475 scopus 로고    scopus 로고
    • An optimized N-dimensional Hough Filter for detecting spherical image objects
    • Mosaliganti K, Gelas A, Cowgill P and Megason S 2009 An optimized N-dimensional Hough Filter for detecting spherical image objects Insight (www.insight.journal.org/browser/publication/698)
    • (2009) Insight
    • Mosaliganti, K.1    Gelas, A.2    Cowgill, P.3    Megason, S.4
  • 22
    • 0029713961 scopus 로고    scopus 로고
    • Dynamic geometrical calibration for 3D cerebral angiography
    • 10.1117/12.237798
    • Navab N 1996 Dynamic geometrical calibration for 3D cerebral angiography Proc. SPIE 2708 361-70 (SPIE)
    • (1996) Proc. SPIE , vol.2708 , pp. 361-370
    • Navab, N.1
  • 23
    • 84865097361 scopus 로고    scopus 로고
    • Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: A tool to reduce wrong-site surgery
    • 10.1088/0031-9155/57/17/5485 0031-9155 5485
    • Otake Y, Schafer S, Stayman J W, Zbijewski W, Kleinszig G, Graumann R, Khanna A J and Siewerdsen J H 2012 Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery Phys. Med. Biol. 57 5485-508
    • (2012) Phys. Med. Biol. , vol.57 , Issue.17 , pp. 5485-5508
    • Otake, Y.1    Schafer, S.2    Stayman, J.W.3    Zbijewski, W.4    Kleinszig, G.5    Graumann, R.6    Khanna, A.J.7    Siewerdsen, J.H.8
  • 27
    • 0034238080 scopus 로고    scopus 로고
    • Image registration by maximization of combined mutual information and gradient information
    • DOI 10.1109/42.876307
    • Pluim J P, Maintz J B and Viergever M A 2000 Image registration by maximization of combined mutual information and gradient information IEEE Trans. Med. Imaging 19 809-14 (Pubitemid 32031207)
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , Issue.8 , pp. 809-814
    • Pluim, J.P.W.1    Maintz, J.B.A.2    Viergever, M.A.3
  • 28
    • 33644798524 scopus 로고    scopus 로고
    • Investigation of C-arm cone-beam CT-guided surgery of the frontal recess
    • DOI 10.1097/01.mlg.0000180759.52082.45, PII 0000553720051200000010
    • Rafferty M A, Siewerdsen J H, Chan Y, Moseley D J, Daly M J, Jaffray D A and Irish J C 2005 Investigation of C-arm cone-beam CT-guided surgery of the frontal recess Laryngoscope 115 2138-43 (Pubitemid 44391626)
    • (2005) Laryngoscope , vol.115 , Issue.12 , pp. 2138-2143
    • Rafferty, M.A.1    Siewerdsen, J.H.2    Chan, Y.3    Moseley, D.J.4    Daly, M.J.5    Jaffray, D.A.6    Irish, J.C.7
  • 29
    • 34548331753 scopus 로고    scopus 로고
    • Calibration model of a dual gain flat panel detector for 2D and 3D x-ray imaging
    • DOI 10.1118/1.2760024
    • Schmidgunst C, Ritter D and Lang E 2007 Calibration model of a dual gain flat panel detector for 2D and 3D x-ray imaging Med. Phys. 34 3649-64 (Pubitemid 47339763)
    • (2007) Medical Physics , vol.34 , Issue.9 , pp. 3649-3664
    • Schmidgunst, C.1    Ritter, D.2    Lang, E.3
  • 31
    • 12844254281 scopus 로고    scopus 로고
    • Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery
    • DOI 10.1118/1.1836331
    • Siewerdsen J H, Moseley D J, Burch S, Bisland S K, Bogaards A, Wilson B C and Jaffray D A 2005 Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery Med. Phys. 32 241-54 (Pubitemid 40165536)
    • (2005) Medical Physics , vol.32 , Issue.1 , pp. 241-254
    • Siewerdsen, J.H.1    Moseley, D.J.2    Burch, S.3    Bisland, S.K.4    Bogaards, A.5    Wilson, B.C.6    Jaffray, D.A.7
  • 32
    • 0028469070 scopus 로고
    • The NeuroStation(TM) - A highly accurate, minimally invasive solution to frameless stereotactic neurosurgery
    • DOI 10.1016/0895-6111(94)90049-3
    • Smith K R, Frank K J and Bucholz R D 1994 The NeurostationTM - a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery Comput. Med. Imaging Graph. 18 247-56 (Pubitemid 24206683)
    • (1994) Computerized Medical Imaging and Graphics , vol.18 , Issue.4 , pp. 247-256
    • Smith, K.R.1    Frank, K.J.2    Bucholz, R.D.3
  • 33
    • 37049229536 scopus 로고
    • Stereotaxic apparatus for operations on the human brain
    • 10.1126/science.106.2754.349
    • Spiegel E A, Wycis H T, Marks M and Lee A J 1947 Stereotaxic apparatus for operations on the human brain Science 106 349-50
    • (1947) Science , vol.106 , pp. 349-350
    • Spiegel, E.A.1    Wycis, H.T.2    Marks, M.3    Lee, A.J.4
  • 34
    • 84867089685 scopus 로고    scopus 로고
    • Model-based tomographic reconstruction of objects containing known components
    • 10.1109/TMI.2012.2199763 0278-0062
    • Stayman J W, Otake Y, Prince J L, Khanna A J and Siewerdsen J H 2012 Model-based tomographic reconstruction of objects containing known components IEEE Trans. Med. Imaging 31 1837-48
    • (2012) IEEE Trans. Med. Imaging , vol.31 , Issue.10 , pp. 1837-1848
    • Stayman, J.W.1    Otake, Y.2    Prince, J.L.3    Khanna, A.J.4    Siewerdsen, J.H.5
  • 35
    • 0036135625 scopus 로고    scopus 로고
    • Routine chest radiography using a flat-panel detector: Image quality at standard detector dose and 33% dose reduction
    • Strotzer M, Völk M, Fründ R, Hamer O, Zorger N and Feuerbach S 2002 Routine chest radiography using a flat-panel detector: image quality at standard detector dose and 33% dose reduction AJR. Am. J. Roentgenol. 178 169-71 (Pubitemid 34016394)
    • (2002) American Journal of Roentgenology , vol.178 , Issue.1 , pp. 169-171
    • Strotzer, M.1    Volk, M.2    Frund, R.3    Hamer, O.4    Zorger, N.5    Feuerbach, S.6
  • 37
    • 27144511689 scopus 로고    scopus 로고
    • A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging
    • DOI 10.1016/j.radonc.2005.05.005, PII S0167814005003452
    • Sykes J R, Amer A, Czajka J and Moore C J 2005 A feasibility study for image guided radiotherapy using low dose, high speed, cone beam x-ray volumetric imaging Radiother. Oncol. 77 45-52 (Pubitemid 41503388)
    • (2005) Radiotherapy and Oncology , vol.77 , Issue.1 , pp. 45-52
    • Sykes, J.R.1    Amer, A.2    Czajka, J.3    Moore, C.J.4
  • 38
    • 0029043863 scopus 로고
    • Vision-based object registration for real-time image overlay
    • 10.1016/0010-4825(94)00045-R 0010-4825
    • Uenohara M and Kanade T 1995 Vision-based object registration for real-time image overlay Comput. Biol. Med. 25 249-60
    • (1995) Comput. Biol. Med. , vol.25 , pp. 249-260
    • Uenohara, M.1    Kanade, T.2
  • 39
    • 84902136314 scopus 로고    scopus 로고
    • Dual-projection 3D-2D registration for surgical guidance: Preclinical evaluation of performance and minimum angular separation
    • 10.1117/12.2043561 90362E
    • Uneri A et al 2014 Dual-projection 3D-2D registration for surgical guidance: preclinical evaluation of performance and minimum angular separation SPIE Medical Imaging ed Z R Yaniv and D R Holmes 90362E pp
    • (2014) SPIE Medical Imaging
    • Uneri, A.1
  • 40
    • 84896364553 scopus 로고    scopus 로고
    • 3D-2D registration for surgical guidance: Effect of projection view angles on registration accuracy
    • 10.1007/s00701-005-0688-y
    • Uneri A, Otake Y, Wang A S, Kleinszig G, Vogt S, Khanna A J and Siewerdsen J H 2013 3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy Phys. Med. Biol. 59 271-87
    • (2013) Phys. Med. Biol. , vol.59 , pp. 271-287
    • Uneri, A.1    Otake, Y.2    Wang, A.S.3    Kleinszig, G.4    Vogt, S.5    Khanna, A.J.6    Siewerdsen, J.H.7
  • 43
    • 33644516000 scopus 로고    scopus 로고
    • Frameless image-guided stereotactic brain biopsy procedure: Diagnostic yield, surgical morbidity, and comparison with the frame-based technique
    • 10.3171/jns.2006.104.2.233 0022-3085
    • Woodworth G F, McGirt M J, Samdani A, Garonzik I, Olivi A and Weingart J D 2006 Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique J. Neurosurg. 104 233-7 (PMID:16509497)
    • (2006) J. Neurosurg. , vol.104 , Issue.2 , pp. 233-237
    • Woodworth, G.F.1    McGirt, M.J.2    Samdani, A.3    Garonzik, I.4    Olivi, A.5    Weingart, J.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.