Volumn 36, Issue 4, 2014, Pages 291-316

Tissue-mimicking gel phantoms for thermal therapy studies

Author keywords

hyperthermia; thermal ablation; thermal gels; thermal stability; tissue equivalency

Indexed keywords

HIGH TEMPERATURE APPLICATIONS; MEDICAL APPLICATIONS; OPTICAL PROPERTIES; THERMODYNAMIC STABILITY; TISSUE;

EID: 84906768668     PISSN: 01617346     EISSN: None     Source Type: Journal    
DOI: 10.1177/0161734614526372     Document Type: Article
Times cited : (78)

References (109)
  • 1
    • 0032875680 scopus 로고    scopus 로고
    • Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements
    • Madsen EL, Dong F, Frank GR, Garras BS, Wear KA, Wilson T, et al. Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements. J Ultrasound Med. 1999 ; 18: 615-31
    • (1999) J Ultrasound Med , vol.18 , pp. 615-631
    • Madsen, E.L.1    Dong, F.2    Frank, G.R.3    Garras, B.S.4    Wear, K.A.5    Wilson, T.6
  • 2
    • 24144460550 scopus 로고    scopus 로고
    • Interlaboratory comparison of ultrasonic backscatter coefficient measurements from 2 to 9 MHz
    • Wear KA, Stiles TA, Frank GR, Madsen GL, Cheng F, Feleppa EJ, et al. Interlaboratory comparison of ultrasonic backscatter coefficient measurements from 2 to 9 MHz. J Ultrasound Med. 2005 ; 24: 1235-50
    • (2005) J Ultrasound Med , vol.24 , pp. 1235-1250
    • Wear, K.A.1    Stiles, T.A.2    Frank, G.R.3    Madsen, G.L.4    Cheng, F.5    Feleppa, E.J.6
  • 3
    • 77955015301 scopus 로고    scopus 로고
    • Interlaboratory comparison of backscatter coefficient estimates for tissue-mimicking phantoms
    • Anderson JJ, Herd MT, King MR, Haak A, Hafez ZT, Song J, et al. Interlaboratory comparison of backscatter coefficient estimates for tissue-mimicking phantoms. Ultrason Imaging. 2010 ; 32: 48-64
    • (2010) Ultrason Imaging , vol.32 , pp. 48-64
    • Anderson, J.J.1    Herd, M.T.2    King, M.R.3    Haak, A.4    Hafez, Z.T.5    Song, J.6
  • 4
    • 0032727146 scopus 로고    scopus 로고
    • Experimental evaluation of the thermal properties of two tissue equivalent phantom materials
    • Craciunescu OI, Howle LE, Clegg ST. Experimental evaluation of the thermal properties of two tissue equivalent phantom materials. Int J Hyperthermia. 1999 ; 15: 509-18
    • (1999) Int J Hyperthermia , vol.15 , pp. 509-518
    • Craciunescu, O.I.1    Howle, L.E.2    Clegg, S.T.3
  • 6
    • 34249319072 scopus 로고    scopus 로고
    • Thermal properties and changes of acoustic parameters in an egg white phantom during heating and coagulation by high intensity focused ultrasound
    • Divkovic GW, Liebler M, Braun K, Dreyer T, Huber PE, Jenne JW. Thermal properties and changes of acoustic parameters in an egg white phantom during heating and coagulation by high intensity focused ultrasound. Ultrasound Med Biol. 2007 ; 33: 981-6
    • (2007) Ultrasound Med Biol , vol.33 , pp. 981-986
    • Divkovic, G.W.1    Liebler, M.2    Braun, K.3    Dreyer, T.4    Huber, P.E.5    Jenne, J.W.6
  • 7
  • 8
    • 0012786962 scopus 로고    scopus 로고
    • Measurement of the thermal conductivity of polyacrylamide tissue-equivalent material
    • Davidson SR, Sherar MD. Measurement of the thermal conductivity of polyacrylamide tissue-equivalent material. Int J Hyperthermia. 2003 ; 19: 551-62
    • (2003) Int J Hyperthermia , vol.19 , pp. 551-562
    • Davidson, S.R.1    Sherar, M.D.2
  • 9
    • 79958856061 scopus 로고    scopus 로고
    • Measurement of the thermal conductivity of carbon nanotube-tissue phantom composites with the hot wire probe method
    • Sarkar S, Zimmermann K, Leng W, Viveksland P, Zhang J, Dorn H, et al. Measurement of the thermal conductivity of carbon nanotube-tissue phantom composites with the hot wire probe method. Ann Biomed Eng. 2011 ; 39: 1745-58
    • (2011) Ann Biomed Eng , vol.39 , pp. 1745-1758
    • Sarkar, S.1    Zimmermann, K.2    Leng, W.3    Viveksland, P.4    Zhang, J.5    Dorn, H.6
  • 11
    • 0034896689 scopus 로고    scopus 로고
    • An approach to acoustic properties of biological tissues using acoustic micrographs of attenuation constant and sound speed
    • Okawai H, Kobayashi K, Nitta S. An approach to acoustic properties of biological tissues using acoustic micrographs of attenuation constant and sound speed. J Ultrasound Med. 2001 ; 20: 891-907
    • (2001) J Ultrasound Med , vol.20 , pp. 891-907
    • Okawai, H.1    Kobayashi, K.2    Nitta, S.3
  • 13
    • 77951587404 scopus 로고    scopus 로고
    • Measurement of ultrasonic properties of muscle and blood biological phantoms
    • Ortega R, Téllez A, Leija L, Vera A. Measurement of ultrasonic properties of muscle and blood biological phantoms. Phys Procedia. 2010 ; 3: 627-34
    • (2010) Phys Procedia , vol.3 , pp. 627-634
    • Ortega, R.1    Téllez, A.2    Leija, L.3    Vera, A.4
  • 15
    • 79851503902 scopus 로고    scopus 로고
    • Augmentation of HIFU-induced heating with fibers embedded in a phantom
    • Labuda CP, Church CC. Augmentation of HIFU-induced heating with fibers embedded in a phantom. Ultrasound Med Biol. 2011 ; 37: 442-9
    • (2011) Ultrasound Med Biol , vol.37 , pp. 442-449
    • Labuda, C.P.1    Church, C.C.2
  • 16
    • 74849103216 scopus 로고    scopus 로고
    • Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound
    • Canney MS, Khokhlova VA, Bessonova OV, Bailey MR, Crum LA. Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound. Ultrasound Med Biol. 2010 ; 36: 250-67
    • (2010) Ultrasound Med Biol , vol.36 , pp. 250-267
    • Canney, M.S.1    Khokhlova, V.A.2    Bessonova, O.V.3    Bailey, M.R.4    Crum, L.A.5
  • 17
    • 34249657878 scopus 로고    scopus 로고
    • HIFU procedures at moderate intensities - Effect of large blood vessels
    • Hariharan P, Myers MR, Banerjee RK. HIFU procedures at moderate intensities - effect of large blood vessels. Phys Med Biol. 2007 ; 52: 3493-513
    • (2007) Phys Med Biol , vol.52 , pp. 3493-3513
    • Hariharan, P.1    Myers, M.R.2    Banerjee, R.K.3
  • 18
    • 84859065356 scopus 로고    scopus 로고
    • Gas-filled phospholipid nanoparticles conjugated with gadolinium play a role as a potential theragnostics for MR-guided HIFU ablation
    • Choi SY, Kim YS, Seo YJ, Yang J, Choi KS. Gas-filled phospholipid nanoparticles conjugated with gadolinium play a role as a potential theragnostics for MR-guided HIFU ablation. PLoS ONE. 2012 ; 7: e34333
    • (2012) PLoS ONE , vol.7 , pp. 34333
    • Choi, S.Y.1    Kim, Y.S.2    Seo, Y.J.3    Yang, J.4    Choi, K.S.5
  • 19
    • 84938011958 scopus 로고
    • Analyses of electromagnetic fields induced in biological tissues by thermographic studies on equivalent phantom models
    • Guy AW. Analyses of electromagnetic fields induced in biological tissues by thermographic studies on equivalent phantom models. IEEE Trans Microw Theory Tech. 1971 ; 16: 205-14
    • (1971) IEEE Trans Microw Theory Tech , vol.16 , pp. 205-214
    • Guy, A.W.1
  • 20
    • 8044243593 scopus 로고    scopus 로고
    • Magnetic resonance imaging of temperature changes during interstitial microwave heating: A phantom study
    • Vitkin IA, Moriarty JA, Peters RD, Kolios MC, Gladman AS, Chen JC, et al. Magnetic resonance imaging of temperature changes during interstitial microwave heating: a phantom study. Med Phys. 1997 ; 24: 269-77
    • (1997) Med Phys , vol.24 , pp. 269-277
    • Vitkin, I.A.1    Moriarty, J.A.2    Peters, R.D.3    Kolios, M.C.4    Gladman, A.S.5    Chen, J.C.6
  • 21
    • 0032256641 scopus 로고    scopus 로고
    • Experimental dosimetry in a sphere of simulated brain tissue near a half-wave dipole antenna
    • Denver, CO
    • Faraone A, Balzano Q, Simunic D. Experimental dosimetry in a sphere of simulated brain tissue near a half-wave dipole antenna. IEEE Symposium on Electromagnetic Compatability ; Denver, CO ;. 906.
    • IEEE Symposium on Electromagnetic Compatability , pp. 906
    • Faraone, A.1    Balzano, Q.2    Simunic, D.3
  • 22
    • 4043068455 scopus 로고    scopus 로고
    • Formulation and characterization of tissue equivalent liquids used for RF densitometry and dosimetry measurements
    • Kanda MY, Ballen M, Salins S, Chung-Kwang C, Balzano Q. Formulation and characterization of tissue equivalent liquids used for RF densitometry and dosimetry measurements. IEEE Trans Microw Theory Tech. 2004 ; 52: 2046-56
    • (2004) IEEE Trans Microw Theory Tech , vol.52 , pp. 2046-2056
    • Kanda, M.Y.1    Ballen, M.2    Salins, S.3    Chung-Kwang, C.4    Balzano, Q.5
  • 23
    • 79251490744 scopus 로고    scopus 로고
    • Improved hyperthermia treatment control using SAR/temperature simulation and PRFS magnetic resonance thermal imaging
    • Li Z, Vogel M, Maccarini PF, Stakhursky V, Soher BJ, Craciunescu OI, et al. Improved hyperthermia treatment control using SAR/temperature simulation and PRFS magnetic resonance thermal imaging. Int J Hyperthermia. 2011 ; 27: 86-99
    • (2011) Int J Hyperthermia , vol.27 , pp. 86-99
    • Li, Z.1    Vogel, M.2    MacCarini, P.F.3    Stakhursky, V.4    Soher, B.J.5    Craciunescu, O.I.6
  • 25
    • 0019203748 scopus 로고
    • Variation in dielectric properties with tissue water content
    • Schepps JL, Foster KR. variation in dielectric properties with tissue water content. Phys Med Biol. 1980 ; 25: 1149-59
    • (1980) Phys Med Biol , vol.25 , pp. 1149-1159
    • Schepps, J.L.1    Foster, K.R.2
  • 27
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues
    • Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys Med Biol. 1996 ; 41: 2271-93
    • (1996) Phys Med Biol , vol.41 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 28
    • 24644517473 scopus 로고    scopus 로고
    • Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications
    • Lazebnik M, Madsen EL, Frank GR, Hagness SC. Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications. Phys Med Biol. 2005 ; 50: 4245-58
    • (2005) Phys Med Biol , vol.50 , pp. 4245-4258
    • Lazebnik, M.1    Madsen, E.L.2    Frank, G.R.3    Hagness, S.C.4
  • 29
    • 84893373750 scopus 로고    scopus 로고
    • Phantom model of human brain tissue for cellular phone frequencies in electromagnetic field radiation absorption studies
    • Ozen S, Koylu H. Phantom model of human brain tissue for cellular phone frequencies in electromagnetic field radiation absorption studies. GU J Sci. 2005 ; 18: 193-200
    • (2005) GU J Sci , vol.18 , pp. 193-200
    • Ozen, S.1    Koylu, H.2
  • 30
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: I. Literature survey
    • Gabriel C, Gabriel S, Corthout E. The dielectric properties of biological tissues: I. Literature survey. Phys Med Biol. 1996 ; 41: 2231-49
    • (1996) Phys Med Biol , vol.41 , pp. 2231-2249
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3
  • 31
    • 33751337831 scopus 로고    scopus 로고
    • Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
    • Pogue BW, Patterson MS. Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. J Biomed Opt. 2006 ; 11: 041102
    • (2006) J Biomed Opt , vol.11 , pp. 041102
    • Pogue, B.W.1    Patterson, M.S.2
  • 32
    • 0025551790 scopus 로고
    • A review of the optical properties of biological tissues
    • Cheong WF, Prahl SA, Welch AJ. A review of the optical properties of biological tissues. IEEE J Quant Electron. 1990 ; 26: 2166-85
    • (1990) IEEE J Quant Electron , vol.26 , pp. 2166-2185
    • Cheong, W.F.1    Prahl, S.A.2    Welch, A.J.3
  • 33
    • 0037326694 scopus 로고    scopus 로고
    • Mechanisms of pulsed laser ablation of biological tissues
    • Vogel A, Venugopalan V. Mechanisms of pulsed laser ablation of biological tissues. Chem Rev. 2003 ; 103: 577-644
    • (2003) Chem Rev , vol.103 , pp. 577-644
    • Vogel, A.1    Venugopalan, V.2
  • 34
    • 34347369553 scopus 로고    scopus 로고
    • Laser-induced thermal response and characterization of nanoparticles for cancer treatment using magnetic resonance thermal imaging
    • Elliott AM, Stafford RJ, Schwartz J, Wang J, Shetty AM, Bourgoyne C, et al. Laser-induced thermal response and characterization of nanoparticles for cancer treatment using magnetic resonance thermal imaging. Med Phys. 2007 ; 34: 3102-8
    • (2007) Med Phys , vol.34 , pp. 3102-3108
    • Elliott, A.M.1    Stafford, R.J.2    Schwartz, J.3    Wang, J.4    Shetty, A.M.5    Bourgoyne, C.6
  • 35
    • 0034072928 scopus 로고    scopus 로고
    • The effects of dynamic optical properties during interstitial laser photocoagulation
    • Iizuka MN, Vitkin IA, Kolios MC, Sherar MD. The effects of dynamic optical properties during interstitial laser photocoagulation. Phys Med Biol. 2000 ; 45: 1335-57
    • (2000) Phys Med Biol , vol.45 , pp. 1335-1357
    • Iizuka, M.N.1    Vitkin, I.A.2    Kolios, M.C.3    Sherar, M.D.4
  • 36
    • 67650721039 scopus 로고    scopus 로고
    • Robust multiparameter method of evaluating the optical and thermal properties of a layered tissue structure using photothermal radiometry
    • Matvienko A, Mandelis A, Abrams S. Robust multiparameter method of evaluating the optical and thermal properties of a layered tissue structure using photothermal radiometry. Appl Opt. 2009 ; 48: 3192-203
    • (2009) Appl Opt , vol.48 , pp. 3192-3203
    • Matvienko, A.1    Mandelis, A.2    Abrams, S.3
  • 37
    • 0026552794 scopus 로고
    • The use of India ink as an optical absorber in tissue-simulating phantoms
    • Madsen SJ, Patterson MS, Wilson BC. The use of India ink as an optical absorber in tissue-simulating phantoms. Phys Med Biol. 1992 ; 37: 985-93
    • (1992) Phys Med Biol , vol.37 , pp. 985-993
    • Madsen, S.J.1    Patterson, M.S.2    Wilson, B.C.3
  • 38
    • 20044393062 scopus 로고    scopus 로고
    • A method for determination of the absorption and scattering properties interstitially in turbid media
    • Dimofte A, Finlay JC, Zhu TC. A method for determination of the absorption and scattering properties interstitially in turbid media. Phys Med Biol. 2005 ; 50: 2291-311
    • (2005) Phys Med Biol , vol.50 , pp. 2291-2311
    • Dimofte, A.1    Finlay, J.C.2    Zhu, T.C.3
  • 39
    • 80051947338 scopus 로고    scopus 로고
    • A feasibility study for non-invasive thermometry using non-linear ultrasound
    • van Dongen KW, Verweij MD. A feasibility study for non-invasive thermometry using non-linear ultrasound. Int J Hyperthermia. 2011 ; 27: 612-24
    • (2011) Int J Hyperthermia , vol.27 , pp. 612-624
    • Van Dongen, K.W.1    Verweij, M.D.2
  • 41
    • 61949332794 scopus 로고    scopus 로고
    • Radiofrequency and microwave ablation of the liver, lung, kidney, and bone: What are the differences?
    • Brace CL. Radiofrequency and microwave ablation of the liver, lung, kidney, and bone: what are the differences?. Curr Probl Diagn Radiol. 2009 ; 38: 135-43
    • (2009) Curr Probl Diagn Radiol , vol.38 , pp. 135-143
    • Brace, C.L.1
  • 42
    • 84906759175 scopus 로고
    • U.S. Patent 3653996. Houston, TX: Atlas Chemicals Industries
    • Edwards DW U.S. Patent 3653996. Houston, TX: Atlas Chemicals Industries 1972.
    • (1972)
    • Edwards, D.W.1
  • 43
    • 24644511347 scopus 로고
    • Experimental development of simulated biomaterials for dosimetry studies of hazardous microwave radiation (Short Papers)
    • Cheung AY, Koopman DW. Experimental development of simulated biomaterials for dosimetry studies of hazardous microwave radiation (Short Papers). IEEE Trans Microw Theory Tech. 1976 ; 24: 669-73
    • (1976) IEEE Trans Microw Theory Tech , vol.24 , pp. 669-673
    • Cheung, A.Y.1    Koopman, D.W.2
  • 44
    • 0021692665 scopus 로고
    • Formulas for preparing phantom muscle tissue at various radiofrequencies
    • Chou CK, Chen GW, Guy AW, Luk KH. Formulas for preparing phantom muscle tissue at various radiofrequencies. Bioelectromagnetics. 1984 ; 5: 435-41
    • (1984) Bioelectromagnetics , vol.5 , pp. 435-441
    • Chou, C.K.1    Chen, G.W.2    Guy, A.W.3    Luk, K.H.4
  • 45
    • 48149106655 scopus 로고    scopus 로고
    • Design and construction of a flow phantom for HIFU research
    • New York, NY
    • Johnson D, Zderic V. Design and construction of a flow phantom for HIFU research. IEEE Ultrasonics Symposium ; New York, NY ;. 1294.
    • IEEE Ultrasonics Symposium , pp. 1294
    • Johnson, D.1    Zderic, V.2
  • 46
    • 6344279826 scopus 로고    scopus 로고
    • Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms
    • Huang J, Holt RG, Cleveland RO, Roy RA. Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms. J Acoust Soc Am. 2004 2451 ; 116 :
    • (2004) J Acoust Soc Am , vol.116 , pp. 2451
    • Huang, J.1    Holt, R.G.2    Cleveland, R.O.3    Roy, R.A.4
  • 47
    • 0019276386 scopus 로고
    • Muscle equivalent agar phantom for 13.56MHz RF-induced hyperthermia
    • Ishida T, Kato H. Muscle equivalent agar phantom for 13.56MHz RF-induced hyperthermia. Shimane J Med Sci. 1980 ; 4: 134-40
    • (1980) Shimane J Med Sci , vol.4 , pp. 134-140
    • Ishida, T.1    Kato, H.2
  • 48
    • 0035121278 scopus 로고    scopus 로고
    • Development and characteristics of a biological tissue-equivalent phantom for microwaves
    • Ito K, Furuya K, Okano Y, Hamada L. Development and characteristics of a biological tissue-equivalent phantom for microwaves. Electron Comm Jpn (Part I). 2001 ; 84: 67-77
    • (2001) Electron Comm Jpn (Part I) , vol.84 , pp. 67-77
    • Ito, K.1    Furuya, K.2    Okano, Y.3    Hamada, L.4
  • 49
    • 50249131226 scopus 로고    scopus 로고
    • Evaluation on biological tissue equivalent agar-based solid phantoms up to 10 GHz - Aiming at measurement of characteristics of antenna for UWB communications
    • Seoul, South Korea
    • Takimoto T, Onishi T, Saito K, Takahashi M, Uebayashi S, Ito K. Evaluation on biological tissue equivalent agar-based solid phantoms up to 10 GHz - aiming at measurement of characteristics of antenna for UWB communications. Proceedings of ISAP ; Seoul, South Korea ;. 483.
    • Proceedings of ISAP , pp. 483
    • Takimoto, T.1    Onishi, T.2    Saito, K.3    Takahashi, M.4    Uebayashi, S.5    Ito, K.6
  • 50
    • 0022544493 scopus 로고
    • An agar phantom for hyperthermia
    • Kato H, Hiraoka M, Ishida T. An agar phantom for hyperthermia. Med Phys. 1986 ; 13: 396-8
    • (1986) Med Phys , vol.13 , pp. 396-398
    • Kato, H.1    Hiraoka, M.2    Ishida, T.3
  • 51
    • 0023161493 scopus 로고
    • Development of an agar phantom adaptable for simulation of various tissues in the range 5-40 MHz
    • Kato H, Ishida T. Development of an agar phantom adaptable for simulation of various tissues in the range 5-40 MHz. Phys Med Biol. 1987 ; 32: 221-6
    • (1987) Phys Med Biol , vol.32 , pp. 221-226
    • Kato, H.1    Ishida, T.2
  • 55
    • 0035673103 scopus 로고    scopus 로고
    • Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material
    • Holt RG, Roy RA. Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material. Ultrasound Med Biol. 2001 ; 27: 1399-412
    • (2001) Ultrasound Med Biol , vol.27 , pp. 1399-1412
    • Holt, R.G.1    Roy, R.A.2
  • 56
    • 76649128713 scopus 로고    scopus 로고
    • The correlation between bubble-enhanced HIFU heating and cavitation power
    • Farny CH, Holt RG, Roy RA. The correlation between bubble-enhanced HIFU heating and cavitation power. IEEE Trans Biomed Eng. 2010 ; 57: 175-84
    • (2010) IEEE Trans Biomed Eng , vol.57 , pp. 175-184
    • Farny, C.H.1    Holt, R.G.2    Roy, R.A.3
  • 58
    • 0032076844 scopus 로고    scopus 로고
    • Liquid or solid ultrasonically tissue-mimicking materials with very low scatter
    • Madsen EL, Frank GR, Dong F. Liquid or solid ultrasonically tissue-mimicking materials with very low scatter. Ultrasound Med Biol. 1998 ; 24: 535-42
    • (1998) Ultrasound Med Biol , vol.24 , pp. 535-542
    • Madsen, E.L.1    Frank, G.R.2    Dong, F.3
  • 60
    • 0036281213 scopus 로고    scopus 로고
    • An in vitro system for Doppler ultrasound flow studies in the stenosed carotid artery bifurcation
    • Poepping TL, Nikolov HN, Rankin RN, Lee M, Holdsworth DW. An in vitro system for Doppler ultrasound flow studies in the stenosed carotid artery bifurcation. Ultrasound Med Biol. 2002 ; 28: 495-506
    • (2002) Ultrasound Med Biol , vol.28 , pp. 495-506
    • Poepping, T.L.1    Nikolov, H.N.2    Rankin, R.N.3    Lee, M.4    Holdsworth, D.W.5
  • 62
    • 77954399250 scopus 로고    scopus 로고
    • Use of gold nanoshells to constrain and enhance laser thermal therapy of metastatic liver tumours
    • Elliott AM, Shetty AM, Wang J, Hazle JD, Jason Stafford R. Use of gold nanoshells to constrain and enhance laser thermal therapy of metastatic liver tumours. Int J Hyperthermia. 2010 ; 26: 434-40
    • (2010) Int J Hyperthermia , vol.26 , pp. 434-440
    • Elliott, A.M.1    Shetty, A.M.2    Wang, J.3    Hazle, J.D.4    Jason Stafford, R.5
  • 63
    • 0032838066 scopus 로고    scopus 로고
    • Optical phantom materials for near infrared laser photocoagulation studies
    • Iizuka MN, Sherar MD, Vitkin IA. Optical phantom materials for near infrared laser photocoagulation studies. Lasers Surg Med. 1999 ; 25: 159-69
    • (1999) Lasers Surg Med , vol.25 , pp. 159-169
    • Iizuka, M.N.1    Sherar, M.D.2    Vitkin, I.A.3
  • 64
    • 84881478247 scopus 로고    scopus 로고
    • Agar-based heat-sensitive gel with linear thermal response over 65-80 °c
    • Siddiqi AK, Cho SH. Agar-based heat-sensitive gel with linear thermal response over 65-80 °C. J Therm Anal Calorim. 2013 ; 111: 1805-9
    • (2013) J Therm Anal Calorim , vol.111 , pp. 1805-1809
    • Siddiqi, A.K.1    Cho, S.H.2
  • 65
    • 22544465241 scopus 로고    scopus 로고
    • Radiofrequency ablation: Importance of background tissue electrical conductivity - An agar phantom and computer modeling study
    • Solazzo SA, Liu Z, Lobo SM, Ahmed M, Hines-Peralta AU, Lenkinski RE, et al. Radiofrequency ablation: importance of background tissue electrical conductivity - an agar phantom and computer modeling study. Radiol. 2005 ; 236: 495-502
    • (2005) Radiol , vol.236 , pp. 495-502
    • Solazzo, S.A.1    Liu, Z.2    Lobo, S.M.3    Ahmed, M.4    Hines-Peralta, A.U.5    Lenkinski, R.E.6
  • 66
    • 33745084591 scopus 로고    scopus 로고
    • Characterization of the RF ablation-induced "oven effect": The importance of background tissue thermal conductivity on tissue heating
    • Liu Z, Ahmed M, Weinstein Y, Yi M, Mahajan RL, Goldberg SN. Characterization of the RF ablation-induced "oven effect": the importance of background tissue thermal conductivity on tissue heating. Int J Hyperthermia. 2006 ; 22: 327-42
    • (2006) Int J Hyperthermia , vol.22 , pp. 327-342
    • Liu, Z.1    Ahmed, M.2    Weinstein, Y.3    Yi, M.4    Mahajan, R.L.5    Goldberg, S.N.6
  • 69
    • 0027054458 scopus 로고
    • Utilization of a multilayer polyacrylamide phantom for evaluation of hyperthermia applicators
    • Surowiec A, Shrivastava PN, Astrahan M, Petrovich Z. Utilization of a multilayer polyacrylamide phantom for evaluation of hyperthermia applicators. Int J Hyperthermia. 1992 ; 8: 795-807
    • (1992) Int J Hyperthermia , vol.8 , pp. 795-807
    • Surowiec, A.1    Shrivastava, P.N.2    Astrahan, M.3    Petrovich, Z.4
  • 70
  • 71
    • 76649086982 scopus 로고    scopus 로고
    • Reusable ultrasonic tissue mimicking hydrogels containing nonionic surface-active agents for visualizing thermal lesions
    • Park SK, Guntur SR, Lee KI, Paeng D-G, Choi MJ. Reusable ultrasonic tissue mimicking hydrogels containing nonionic surface-active agents for visualizing thermal lesions. IEEE Trans Biomed Eng. 2010 ; 57: 194-202
    • (2010) IEEE Trans Biomed Eng , vol.57 , pp. 194-202
    • Park, S.K.1    Guntur, S.R.2    Lee, K.I.3    Paeng, D.-G.4    Choi, M.J.5
  • 73
    • 0034082285 scopus 로고    scopus 로고
    • Magnetic resonance imaging of thermal coagulation effects in a phantom for calibrating thermal therapy devices
    • Bouchard LS, Bronskill MJ. Magnetic resonance imaging of thermal coagulation effects in a phantom for calibrating thermal therapy devices. Med Phys. 2000 ; 27: 1141-5
    • (2000) Med Phys , vol.27 , pp. 1141-1145
    • Bouchard, L.S.1    Bronskill, M.J.2
  • 75
    • 84906759179 scopus 로고    scopus 로고
    • Localization and enhancement of cavitation and heating during HIFU exposure using microparticles of high surface roughness
    • Arora M, Arvanitis C, Cox E, Coussios CC. Localization and enhancement of cavitation and heating during HIFU exposure using microparticles of high surface roughness. J Acoust Soc Am. 2008 2997 ; 123 :
    • J Acoust Soc Am , vol.123
    • Arora, M.1    Arvanitis, C.2    Cox, E.3    Coussios, C.C.4
  • 76
    • 77958154455 scopus 로고    scopus 로고
    • An in vitro study of a phase-shift nanoemulsion: A potential nucleation agent for bubble-enhanced HIFU tumor ablation
    • Zhang P, Porter T. An in vitro study of a phase-shift nanoemulsion: a potential nucleation agent for bubble-enhanced HIFU tumor ablation. Ultrasound Med Biol. 2010 ; 36: 1856-66
    • (2010) Ultrasound Med Biol , vol.36 , pp. 1856-1866
    • Zhang, P.1    Porter, T.2
  • 77
    • 33644661412 scopus 로고    scopus 로고
    • Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom
    • Khokhlova VA, Bailey MR, Reed JA, Cunitz BW, Kaczkowski PJ, Crum LA. Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom. J Acoust Soc Am. 2006 ; 119: 1834-48
    • (2006) J Acoust Soc Am , vol.119 , pp. 1834-1848
    • Khokhlova, V.A.1    Bailey, M.R.2    Reed, J.A.3    Cunitz, B.W.4    Kaczkowski, P.J.5    Crum, L.A.6
  • 78
    • 84873525670 scopus 로고    scopus 로고
    • A tissue mimicking polyacrylamide hydrogel phantom for visualizing thermal lesions generated by high intensity focused ultrasound
    • Choi MJ, Guntur SR, Lee KI, Paeng DG, Coleman A. A tissue mimicking polyacrylamide hydrogel phantom for visualizing thermal lesions generated by high intensity focused ultrasound. Ultrasound Med Biol. 2013 ; 39: 439-48
    • (2013) Ultrasound Med Biol , vol.39 , pp. 439-448
    • Choi, M.J.1    Guntur, S.R.2    Lee, K.I.3    Paeng, D.G.4    Coleman, A.5
  • 79
    • 0035730974 scopus 로고    scopus 로고
    • Development and characterization of an innovative synthetic tissue-mimicking material for high intensity focused ultrasound (HIFU) exposures
    • Atlanta, GA
    • Lafon C, Kaczkowski PJ, Vaezy S, Noble M, Sapozhnikov OA. Development and characterization of an innovative synthetic tissue-mimicking material for high intensity focused ultrasound (HIFU) exposures. IEEE Ultrasonics Symposium ; Atlanta, GA ;. 1295.
    • IEEE Ultrasonics Symposium , pp. 1295
    • Lafon, C.1    Kaczkowski, P.J.2    Vaezy, S.3    Noble, M.4    Sapozhnikov, O.A.5
  • 80
    • 9644310477 scopus 로고    scopus 로고
    • Polyacrylamide gel containing egg white as new model for irradiation experiments using focused ultrasound
    • Takegami K, Kaneko Y, Watanabe T, Maruyama T, Matsumoto Y, Nagawa H. Polyacrylamide gel containing egg white as new model for irradiation experiments using focused ultrasound. Ultrasound Med Biol. 2004 ; 30: 1419-22
    • (2004) Ultrasound Med Biol , vol.30 , pp. 1419-1422
    • Takegami, K.1    Kaneko, Y.2    Watanabe, T.3    Maruyama, T.4    Matsumoto, Y.5    Nagawa, H.6
  • 81
    • 0029349872 scopus 로고
    • A method for observing the three-dimensional patterns of electromagnetic power absorbed by the human body-The gel phantom of the human body used to study the electromagnetic environmental problem
    • Miyakawa M, Takahashi N, Hoshina S. A method for observing the three-dimensional patterns of electromagnetic power absorbed by the human body-the gel phantom of the human body used to study the electromagnetic environmental problem. Electron Comm Jpn (Part I). 1995 ; 78: 99-112
    • (1995) Electron Comm Jpn (Part I) , vol.78 , pp. 99-112
    • Miyakawa, M.1    Takahashi, N.2    Hoshina, S.3
  • 83
    • 84893415944 scopus 로고    scopus 로고
    • Reusable heat-sensitive phantom for precise estimation of thermal profile in hyperthermia application
    • Dabbagh A, Abdullah BJJ, Abu Kasim NH, Ramasindarum C. Reusable heat-sensitive phantom for precise estimation of thermal profile in hyperthermia application. Int J Hyperthermia. 2014 ; 30: 66-74
    • (2014) Int J Hyperthermia , vol.30 , pp. 66-74
    • Dabbagh, A.1    Bjj, A.2    Abu Kasim, N.H.3    Ramasindarum, C.4
  • 84
    • 84860725589 scopus 로고    scopus 로고
    • Inducing occlusion effect in Y-shaped vessels using high-intensity focused ultrasound: Finite element analysis and phantom validation
    • Jiang C, Wu MC, Wu YS. Inducing occlusion effect in Y-shaped vessels using high-intensity focused ultrasound: finite element analysis and phantom validation. Comput Methods Biomech Biomed Engin. 2012 ; 15: 323-32
    • (2012) Comput Methods Biomech Biomed Engin , vol.15 , pp. 323-332
    • Jiang, C.1    Wu, M.C.2    Wu, Y.S.3
  • 86
    • 0023103498 scopus 로고
    • Simulated biological materials for electromagnetic radiation absorption studies
    • Hartsgrove G, Kraszewski A, Surowiec A. Simulated biological materials for electromagnetic radiation absorption studies. Bioelectromagnetics. 1987 ; 8: 29-36
    • (1987) Bioelectromagnetics , vol.8 , pp. 29-36
    • Hartsgrove, G.1    Kraszewski, A.2    Surowiec, A.3
  • 87
    • 12244259071 scopus 로고    scopus 로고
    • Phantom and animal tissues for modelling the electrical properties of human liver
    • Stauffer PR, Rossetto F, Prakash M, Neuman DG, Lee T. Phantom and animal tissues for modelling the electrical properties of human liver. Int J Hyperthermia. 2003 ; 19: 89-101
    • (2003) Int J Hyperthermia , vol.19 , pp. 89-101
    • Stauffer, P.R.1    Rossetto, F.2    Prakash, M.3    Neuman, D.G.4    Lee, T.5
  • 88
    • 0035051778 scopus 로고    scopus 로고
    • Controlled release of growth factors based on biodegradation of gelatin hydrogel
    • Yamamoto M, Ikada Y, Tabata Y. Controlled release of growth factors based on biodegradation of gelatin hydrogel. J Biomater Sci Polym Ed. 2001 ; 12: 77-88
    • (2001) J Biomater Sci Polym Ed , vol.12 , pp. 77-88
    • Yamamoto, M.1    Ikada, Y.2    Tabata, Y.3
  • 91
    • 0024317510 scopus 로고
    • Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHz
    • Marchal C, Nadi M, Tosser AJ, Roussey C, Gaulard ML. Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHz. Int J Hyperthermia. 1989 ; 5: 725-32
    • (1989) Int J Hyperthermia , vol.5 , pp. 725-732
    • Marchal, C.1    Nadi, M.2    Tosser, A.J.3    Roussey, C.4    Gaulard, M.L.5
  • 93
    • 84863402037 scopus 로고    scopus 로고
    • A heterogeneous human tissue mimicking phantom for RF heating and MRI thermal monitoring verification
    • Yuan Y, Wyatt C, Maccarini P, Stauffer P, Craciunescu O, Macfall J, et al. A heterogeneous human tissue mimicking phantom for RF heating and MRI thermal monitoring verification. Phys Med Biol. 2012 ; 57: 2021-37
    • (2012) Phys Med Biol , vol.57 , pp. 2021-2037
    • Yuan, Y.1    Wyatt, C.2    MacCarini, P.3    Stauffer, P.4    Craciunescu, O.5    MacFall, J.6
  • 95
    • 77953124146 scopus 로고    scopus 로고
    • Construction and evaluation of an anatomically correct multi-image modality compatible phantom for prostate cancer focal ablation
    • Lindner U, Lawrentschuk N, Weersink RA, Raz O, Hlasny E, Sussman MS, et al. Construction and evaluation of an anatomically correct multi-image modality compatible phantom for prostate cancer focal ablation. J Urol. 2010 ; 184: 352-7
    • (2010) J Urol , vol.184 , pp. 352-357
    • Lindner, U.1    Lawrentschuk, N.2    Weersink, R.A.3    Raz, O.4    Hlasny, E.5    Sussman, M.S.6
  • 96
    • 0031950630 scopus 로고    scopus 로고
    • Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry
    • Baldock C, Burford RP, Billingham N, Wagner GS, Patval S, Badawi RD, et al. Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry. Phys Med Biol. 1998 ; 43: 695-702
    • (1998) Phys Med Biol , vol.43 , pp. 695-702
    • Baldock, C.1    Burford, R.P.2    Billingham, N.3    Wagner, G.S.4    Patval, S.5    Badawi, R.D.6
  • 97
  • 98
    • 79959577679 scopus 로고    scopus 로고
    • Effect of graphite concentration on shear-wave speed in gelatin-based tissue-mimicking phantoms
    • Anderson PG, Rouze NC, Palmeri ML. Effect of graphite concentration on shear-wave speed in gelatin-based tissue-mimicking phantoms. Ultrason Imaging. 2011 ; 33: 134-42
    • (2011) Ultrason Imaging , vol.33 , pp. 134-142
    • Anderson, P.G.1    Rouze, N.C.2    Palmeri, M.L.3
  • 99
    • 24644465982 scopus 로고    scopus 로고
    • Development of a new hybrid gel phantom using carrageenan and gellan gum for visualizing three-dimensional temperature distribution during hyperthermia and radiofrequency ablation
    • Kuroda M, Kato H, Hanamoto K, Shimamura K, Uchida T, Wang Y, et al. Development of a new hybrid gel phantom using carrageenan and gellan gum for visualizing three-dimensional temperature distribution during hyperthermia and radiofrequency ablation. Int J Oncol. 2005 ; 27: 175-84
    • (2005) Int J Oncol , vol.27 , pp. 175-184
    • Kuroda, M.1    Kato, H.2    Hanamoto, K.3    Shimamura, K.4    Uchida, T.5    Wang, Y.6
  • 100
    • 34548207652 scopus 로고    scopus 로고
    • Rheology and microrheology of a microstructured fluid: The gellan gum case
    • Caggioni M, Spicer PT, Blair DL, Lindberg SE, Weitz DA. Rheology and microrheology of a microstructured fluid: the gellan gum case. J Rheol. 2007 ; 51: 851-65
    • (2007) J Rheol , vol.51 , pp. 851-865
    • Caggioni, M.1    Spicer, P.T.2    Blair, D.L.3    Lindberg, S.E.4    Weitz, D.A.5
  • 103
    • 9744268862 scopus 로고    scopus 로고
    • Development of a phantom compatible for MRI and hyperthermia using carrageenan gel-relationship between T1 and T2 values and NaCl concentration
    • Yoshida A, Kato H, Kuroda M, Hanamoto K, Yoshimura K, Shibya K, et al. Development of a phantom compatible for MRI and hyperthermia using carrageenan gel-relationship between T1 and T2 values and NaCl concentration. Int J Hyperthermia. 2004 ; 20: 803-14
    • (2004) Int J Hyperthermia , vol.20 , pp. 803-814
    • Yoshida, A.1    Kato, H.2    Kuroda, M.3    Hanamoto, K.4    Yoshimura, K.5    Shibya, K.6
  • 104
    • 3442900013 scopus 로고    scopus 로고
    • Development of a phantom compatible for MRI and hyperthermia using carrageenan gel - Relationship between dielectric properties and NaCl concentration
    • Kato H, Yoshimura K, Kuroda M, Yoshida A, Hanamoto K, Kawasaki S, et al. Development of a phantom compatible for MRI and hyperthermia using carrageenan gel - relationship between dielectric properties and NaCl concentration. Int J Hyperthermia. 2004 ; 20: 529-38
    • (2004) Int J Hyperthermia , vol.20 , pp. 529-538
    • Kato, H.1    Yoshimura, K.2    Kuroda, M.3    Yoshida, A.4    Hanamoto, K.5    Kawasaki, S.6
  • 105
    • 1542608724 scopus 로고    scopus 로고
    • Processing of resorbable poly-α-hydroxy acids for use as tissue-engineering scaffolds
    • Kellomaki M, Tormala P. Processing of resorbable poly-α-hydroxy acids for use as tissue-engineering scaffolds. Methods Mol Biol. 2004 ; 238: 1-10
    • (2004) Methods Mol Biol , vol.238 , pp. 1-10
    • Kellomaki, M.1    Tormala, P.2
  • 106
    • 42149189420 scopus 로고    scopus 로고
    • Effective cancer laser-therapy design through the integration of nanotechnology and computational treatment planning models
    • San Jose, CA ;. 68690D
    • Fisher JW, Rylander MN. Effective cancer laser-therapy design through the integration of nanotechnology and computational treatment planning models. SPIE, Plasmonics in Biology and Medicine V Vol. 6869 ; San Jose, CA ;. 68690D.
    • SPIE, Plasmonics in Biology and Medicine v Vol. 6869
    • Fisher, J.W.1    Rylander, M.N.2
  • 107
    • 80455177152 scopus 로고    scopus 로고
    • Optical properties of breast tumor phantoms containing carbon nanotubes and nanohorns
    • Sarkar S, Gurjarpadhye AA, Rylander CG, Nichole Rylander M. Optical properties of breast tumor phantoms containing carbon nanotubes and nanohorns. J Biomed Opt. 2011 ; 16: 051304
    • (2011) J Biomed Opt , vol.16 , pp. 051304
    • Sarkar, S.1    Gurjarpadhye, A.A.2    Rylander, C.G.3    Nichole Rylander, M.4
  • 108
    • 0035869827 scopus 로고    scopus 로고
    • Ionically crosslinked alginate hydrogels as scaffolds for tissue engineering: Part 1. Structure, gelation rate and mechanical properties
    • Kuo CK, Ma PX. Ionically crosslinked alginate hydrogels as scaffolds for tissue engineering: part 1. structure, gelation rate and mechanical properties. Biomaterials. 2001 ; 22: 511-21
    • (2001) Biomaterials , vol.22 , pp. 511-521
    • Kuo, C.K.1    Ma, P.X.2
  • 109
    • 36048974621 scopus 로고    scopus 로고
    • Acoustical properties of selected tissue phantom materials for ultrasound imaging
    • Zell K, Sperl J, Vogel M, Niessner R, Haisch C. Acoustical properties of selected tissue phantom materials for ultrasound imaging. Phys Med Biol. 2007 ; 52: N475-84
    • (2007) Phys Med Biol , vol.52 , pp. 475-484
    • Zell, K.1    Sperl, J.2    Vogel, M.3    Niessner, R.4    Haisch, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.