메뉴 건너뛰기




Volumn 2, Issue , 2005, Pages 132-

Frequency-domain hypothesis testing approach to leak detection in a single fluid line

Author keywords

Frequency domain estimation; Laplace domain fluid line model; Leak detection

Indexed keywords

FREQUENCY DOMAIN ANALYSIS; LAPLACE TRANSFORMS; WATER MANAGEMENT;

EID: 84906282700     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 1
    • 80051888482 scopus 로고
    • The Transient Response of Fluid Lines
    • Brown, F. T., The Transient Response of Fluid Lines, Journal of Basic Engineering, ASME, vol. 84, pp. 547-553, 1962.
    • (1962) Journal of Basic Engineering, ASME , vol.84 , pp. 547-553
    • Brown, F.T.1
  • 2
    • 0035182798 scopus 로고    scopus 로고
    • Detecting Leaks in Pressurised Pipes by Means of Transients
    • Brunone, B. and Ferrante, M., Detecting Leaks in Pressurised Pipes by Means of Transients, Journal of Hydraulic Research, IAHR, vol. 39, pp. 539-547, 2001.
    • (2001) Journal of Hydraulic Research, IAHR , vol.39 , pp. 539-547
    • Brunone, B.1    Ferrante, M.2
  • 3
    • 0037217888 scopus 로고    scopus 로고
    • Pipe System Diagnosis and Leak Detection by Unsteady-State Tests. 1. Harmonic Analysis
    • Ferrante, M., & B. Brunone, Pipe System Diagnosis and Leak Detection by Unsteady-State Tests. 1. Harmonic Analysis, Advances in Water Resources, vol. 26, pp. 95-105, 2003.
    • (2003) Advances In Water Resources , vol.26 , pp. 95-105
    • Ferrante, M.1    Brunone, B.2
  • 5
    • 85007718382 scopus 로고
    • Transfer functions and input impedances of pressurized piping systems
    • Johnson, B. L., & Wandling, D. E., Transfer functions and input impedances of pressurized piping systems, Journal of Basic Engineering, ASME, pp. 440-443, 1967.
    • (1967) Journal of Basic Engineering, ASME , pp. 440-443
    • Johnson, B.L.1    Wandling, D.E.2
  • 6
    • 18444386797 scopus 로고    scopus 로고
    • Leak location using the pattern of the frequency response diagram in pipelines: A numerical study
    • In Press, Corrected Proof
    • Lee, P. J., Vitkovsky, J. P., Lambert, M. F., Simpson, A. R., & Liggett, J. A., "Leak location using the pattern of the frequency response diagram in pipelines: a numerical study," Journal of Sound and Vibration, vol. In Press, Corrected Proof, 2005.
    • (2005) Journal of Sound and Vibration
    • Lee, P.J.1    Vitkovsky, J.P.2    Lambert, M.F.3    Simpson, A.R.4    Liggett, J.A.5
  • 11
    • 0035366175 scopus 로고    scopus 로고
    • Multi-leak detection and isolation in fluid pipelines
    • Verde, C., Multi-leak detection and isolation in fluid pipelines, Control Engineering Practice, vol. 9, pp. 673-682, 2001.
    • (2001) Control Engineering Practice , vol.9 , pp. 673-682
    • Verde, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.