메뉴 건너뛰기




Volumn 1, Issue , 2005, Pages

Wavelet analysis of numerical pressure signals for leak monitoring

Author keywords

Leak monitoring; Pipe; Transient; Wavelet analysis

Indexed keywords

PIPE; TRANSIENTS; WATER MANAGEMENT;

EID: 84906261828     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (11)
  • 2
    • 0033197897 scopus 로고    scopus 로고
    • 'Transient test-based technique for leak detection in outfall pipes'
    • Brunone, B. 'Transient test-based technique for leak detection in outfall pipes'. J. of Water Resources Planning and Management, ASCE, 125, 1999, pp. 302-306.
    • (1999) J. of Water Resources Planning and Management, ASCE , vol.125 , pp. 302-306
    • Brunone, B.1
  • 3
    • 0035182798 scopus 로고    scopus 로고
    • 'Detecting leaks in pressurised pipes by means of transients'
    • Brunone, B., and Ferrante, M. 'Detecting leaks in pressurised pipes by means of transients'. J. of Hydraulic Research, IAHR, 39, 2001, pp. 539-547.
    • (2001) J. of Hydraulic Research, IAHR , vol.39 , pp. 539-547
    • Brunone, B.1    Ferrante, M.2
  • 6
    • 84906237135 scopus 로고    scopus 로고
    • A. Anderson, editor. Proc., 8th Int. Conf. on 'Pressure Surges', Mechanical Engineering Publications, Bury St. Edmunds (UK)
    • Covas, D., Ramos, H., and Betamio de Almeida, A. 'Leak location in pipe systems using pressure surges', in A. Anderson, editor. Proc., 8th Int. Conf. on 'Pressure Surges', Mechanical Engineering Publications, Bury St. Edmunds (UK), 2000, pp. 169-179.
    • (2000) 'Leak Location In Pipe Systems Using Pressure Surges' , pp. 169-179
    • Covas, D.1    Ramos, H.2    de Almeida, B.A.3
  • 7
    • 33747187581 scopus 로고
    • Society for Industrial and Applied Mathematics. Philadelphia, Pa
    • Daubechies, I. 'Ten lectures on wavelets'. Society for Industrial and Applied Mathematics. Philadelphia, Pa, 1992.
    • (1992) 'Ten Lectures On Wavelets'
    • Daubechies, I.1
  • 8
    • 0037217888 scopus 로고    scopus 로고
    • 'Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis'
    • Ferrante, M., and Brunone, B. 'Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis'. Advances in Water Resources, 26, 2003, pp. 95-105.
    • (2003) Advances In Water Resources , vol.26 , pp. 95-105
    • Ferrante, M.1    Brunone, B.2
  • 9
    • 0037221351 scopus 로고    scopus 로고
    • 'Pipe system diagnosis and leak detection by unsteady-state tests. 2. Wavelet analysis'
    • Ferrante, M. and Brunone, B. 'Pipe system diagnosis and leak detection by unsteady-state tests. 2. Wavelet analysis'. Advances in Water Resources, 26, 2003, pp. 107-116.
    • (2003) Advances In Water Resources , vol.26 , pp. 107-116
    • Ferrante, M.1    Brunone, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.