메뉴 건너뛰기




Volumn , Issue , 2014, Pages 58-63

A bendable and wearable cardiorespiratory monitoring device fusing two noncontact sensor principles

Author keywords

non contact monitoring; sensor fusion; wearable sensors

Indexed keywords

MOBILE DEVICES; PHYSIOLOGICAL MODELS;

EID: 84905989353     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BSN.2014.10     Document Type: Conference Paper
Times cited : (8)

References (9)
  • 2
    • 0007096418 scopus 로고
    • Electronic device for physiological kinetic measurements and detection of extraneous bodies
    • R. Vas, "Electronic Device for Physiological Kinetic Measurements and Detection of Extraneous Bodies," IEEE Transactions on Biomedical Engineering, vol. BME-14, no. 1, pp. 2-6, 1967.
    • (1967) IEEE Transactions on Biomedical Engineering , vol.BME-14 , Issue.1 , pp. 2-6
    • Vas, R.1
  • 3
    • 0026128984 scopus 로고
    • Noninvasive detection of ventricular wall motion by electromagnetic coupling: Part 2: Experimental
    • M. G. Pepper, D. J. E. Taylor, and M. C. Kwok, "Noninvasive detection of ventricular wall motion by electromagnetic coupling: Part 2: Experimental," Medical & Biological Engineering & Computing, vol. 29, no. 2, pp. 141-148, 1991.
    • (1991) Medical & Biological Engineering & Computing , vol.29 , Issue.2 , pp. 141-148
    • Pepper, M.G.1    Taylor, D.J.E.2    Kwok, M.C.3
  • 5
    • 77954672844 scopus 로고    scopus 로고
    • Model of an inductive sensor of cardiac activity attached to patient
    • J. Vedru and R. Gordon, "Model of an inductive sensor of cardiac activity attached to patient," Journal of Physics: Conference Series, vol. 224, p. 012010, 2010.
    • (2010) Journal of Physics: Conference Series , vol.224 , pp. 012010
    • Vedru, J.1    Gordon, R.2
  • 6
    • 84892143930 scopus 로고    scopus 로고
    • The MAIN shirt: A textile-integrated magnetic induction sensor array
    • D. Teichmann, A. Kuhn, S. Leonhardt, and M. Walter, "The MAIN Shirt: A Textile-Integrated Magnetic Induction Sensor Array," Sensors (Basel, Switzerland), vol. 14, no. 1, pp. 1039-1056, 2014.
    • (2014) Sensors (Basel, Switzerland) , vol.14 , Issue.1 , pp. 1039-1056
    • Teichmann, D.1    Kuhn, A.2    Leonhardt, S.3    Walter, M.4
  • 8
    • 84861724400 scopus 로고    scopus 로고
    • A wireless reflectance pulse oximeter with digital baseline control for unfiltered photoplethysmograms
    • K. Li and S. Warren, "A Wireless Reflectance Pulse Oximeter With Digital Baseline Control for Unfiltered Photoplethysmograms," IEEE Transactions on Biomedical Circuits and Systems, vol. 6, no. 3, pp. 269-278, 2012.
    • (2012) IEEE Transactions on Biomedical Circuits and Systems , vol.6 , Issue.3 , pp. 269-278
    • Li, K.1    Warren, S.2
  • 9
    • 84862752804 scopus 로고    scopus 로고
    • Advances in reflective oxygen saturation monitoring with a novel in-ear sensor system: Results of a human hypoxia study
    • B. Venema, N. Blanik, V. Blazek, H. Gehring, A. Opp, and S. Leonhardt, "Advances in reflective oxygen saturation monitoring with a novel in-ear sensor system: results of a human hypoxia study," IEEE transactions on bio-medical engineering, vol. 59, no. 7, pp. 2003-2010, 2012.
    • (2012) IEEE Transactions on Bio-medical Engineering , vol.59 , Issue.7 , pp. 2003-2010
    • Venema, B.1    Blanik, N.2    Blazek, V.3    Gehring, H.4    Opp, A.5    Leonhardt, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.