메뉴 건너뛰기




Volumn 8, Issue 3, 2014, Pages 443-445

Retention of central line guide wire

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ANESTHESIA INDUCTION; ANESTHESIST; ARTIFICIAL VENTILATION; CASE REPORT; CENTRAL VENOUS CATHETER; DEVICE REMOVAL; ENDOTRACHEAL INTUBATION; FEMALE; HUMAN; INTENSIVE CARE UNIT; LARYNX EDEMA; LETTER; PATIENT POSITIONING; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RADICAL HYSTERECTOMY; RETAINED INSTRUMENT; SURGICAL APPROACH; VASCULAR GUIDE WIRE; VERY ELDERLY;

EID: 84905726137     PISSN: 1658354X     EISSN: 09753125     Source Type: Journal    
DOI: 10.4103/1658-354X.136655     Document Type: Letter
Times cited : (5)

References (6)
  • 1
    • 2442713397 scopus 로고
    • Catheter replacement of the needle in percutaneous arteriography; A new technique
    • Seldinger SI. Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta radiol 1953;39:368-76.
    • (1953) Acta Radiol , vol.39 , pp. 368-376
    • Seldinger, S.I.1
  • 2
    • 0037456765 scopus 로고    scopus 로고
    • Preventing complications of central venous catheterization
    • McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med 2003;348:1123-33.
    • (2003) N Engl J Med , vol.348 , pp. 1123-1133
    • McGee, D.C.1    Gould, M.K.2
  • 3
    • 0037305671 scopus 로고    scopus 로고
    • Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients
    • Bessoud B, de Baere T, Kuoch V, Desruennes E, Cosset MF, Lassau N, et al. Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients. AJR Am J Roentgenol 2003;180:527-32.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 527-532
    • Bessoud, B.1    De Baere, T.2    Kuoch, V.3    Desruennes, E.4    Cosset, M.F.5    Lassau, N.6
  • 4
    • 84860262612 scopus 로고    scopus 로고
    • A potentially hazardous complication during central venous catheterization: Lost guidewire retained in the patient
    • Song Y, Messerlian AK, Matevosian R. A potentially hazardous complication during central venous catheterization: Lost guidewire retained in the patient. J Clin Anesth 2012;24: 221-6.
    • (2012) J Clin Anesth , vol.24 , pp. 221-226
    • Song, Y.1    Messerlian, A.K.2    Matevosian, R.3
  • 5
    • 84877734837 scopus 로고    scopus 로고
    • Special article: Retained guidewires after intraoperative placement of central venous catheters
    • Vannucci A, Jeffcoat A, Ifune C, Salinas C, Duncan JR, Wall M. Special article: Retained guidewires after intraoperative placement of central venous catheters. Anesth Analg 2013;117:102-8.
    • (2013) Anesth Analg , vol.117 , pp. 102-108
    • Vannucci, A.1    Jeffcoat, A.2    Ifune, C.3    Salinas, C.4    Duncan, J.R.5    Wall, M.6