Volumn 146, Issue 2, 2014, Pages 383-388

Lung ultrasonography for the diagnosis of severe neonatal pneumonia

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CHINA; CLINICAL FEATURE; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; DISEASE SEVERITY; ECHOGRAPHY; FEMALE; HOSPITAL ADMISSION; HUMAN; IMAGE ANALYSIS; INFECTIOUS PNEUMONIA; INTERSTITIAL LUNG DISEASE; LUNG ULTRASONOGRAPHY; MAJOR CLINICAL STUDY; MALE; MEDICAL HISTORY; NEWBORN; NEWBORN PNEUMONIA; PEDIATRIC HOSPITAL; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; THORAX RADIOGRAPHY; ULTRASOUND;

EID: 84905650779     PISSN: 00123692     EISSN: 19313543     Source Type: Journal    
DOI: 10.1378/chest.13-2852     Document Type: Article
Times cited : (136)

References (25)
  • 1
    • 85009717410 scopus 로고    scopus 로고
    • The clinical epidemiology of neonatal respiratory failure in Hebei Children's Hospital
    • Guo YM, Liu CQ. The clinical epidemiology of neonatal respiratory failure in Hebei Children's Hospital . Zhonghua Weichan Yixue Zazhi . 2012;15(11):670-675.
    • (2012) Zhonghua Weichan Yixue Zazhi , vol.15 , Issue.11 , pp. 670-675
    • Guo, Y.M.1    Liu, C.Q.2
  • 2
    • 85009709300 scopus 로고    scopus 로고
    • Analysis of 7970 cases in-hospital newborn infants
    • Rao Y. Analysis of 7970 cases in-hospital newborn infants. Zhongguo Bing An. 2012;13(1):71-73.
    • (2012) Zhongguo Bing An , vol.13 , Issue.1 , pp. 71-73
    • Rao, Y.1
  • 3
    • 85009712229 scopus 로고    scopus 로고
    • Analysis of death reasons in 1509 newborn infants
    • Zhao H, Jin ZJ. Analysis of death reasons in 1509 newborn infants. Zhongguo Fu You Jian Kang Yan Jiu. 2009;20(5):686-688.
    • (2009) Zhongguo Fu You Jian Kang Yan Jiu , vol.20 , Issue.5 , pp. 686-688
    • Zhao, H.1    Jin, Z.J.2
  • 4
    • 84862992799 scopus 로고    scopus 로고
    • The role of lung ultrasound in the diagnosis and follow-up of community-acquired pneumonia
    • Reissig A, Gramegna A, Aliberti S. The role of lung ultrasound in the diagnosis and follow-up of community-acquired pneumonia. Eur J Intern Med. 2012;23(5):391-397.
    • (2012) Eur J Intern Med , vol.23 , Issue.5 , pp. 391-397
    • Reissig, A.1    Gramegna, A.2    Aliberti, S.3
  • 5
    • 84874109431 scopus 로고    scopus 로고
    • Lung ultrasound characteristics of community-acquired pneumonia in hospitalized children
    • Caiulo VA, Gargani L, Caiulo S, et al. Lung ultrasound characteristics of community-acquired pneumonia in hospitalized children. Pediatr Pulmonol. 2013;48(3):280-287.
    • (2013) Pediatr Pulmonol , vol.48 , Issue.3 , pp. 280-287
    • Caiulo, V.A.1    Gargani, L.2    Caiulo, S.3
  • 6
    • 84455183121 scopus 로고    scopus 로고
    • Lung ultrasound is an accurate diagnostic tool for the diagnosis of pneumonia in the emergency department
    • Cortellaro F, Colombo S, Coen D, Duca PG. Lung ultrasound is an accurate diagnostic tool for the diagnosis of pneumonia in the emergency department. Emerg Med J. 2012;29(1):19-23.
    • (2012) Emerg Med J , vol.29 , Issue.1 , pp. 19-23
    • Cortellaro, F.1    Colombo, S.2    Coen, D.3    Duca, P.G.4
  • 7
    • 84864259470 scopus 로고    scopus 로고
    • Lung ultrasound in evaluation of pneumonia
    • Blaivas M. Lung ultrasound in evaluation of pneumonia. J Ultrasound Med. 2012;31(6):823-826.
    • (2012) J Ultrasound Med , vol.31 , Issue.6 , pp. 823-826
    • Blaivas, M.1
  • 8
    • 84867125666 scopus 로고    scopus 로고
    • Lung ultrasound in the diagnosis and follow-up of community-acquired pneumonia: A prospective, multicenter, diagnostic accuracy study
    • Reissig A, Copetti R, Mathis G, et al. Lung ultrasound in the diagnosis and follow-up of community-acquired pneumonia: a prospective, multicenter, diagnostic accuracy study. Chest. 2012;142(4):965-972.
    • (2012) Chest , vol.142 , Issue.4 , pp. 965-972
    • Reissig, A.1    Copetti, R.2    Mathis, G.3
  • 9
    • 1342310781 scopus 로고    scopus 로고
    • Ultrasound diagnosis of alveolar consolidation in the critically ill
    • DOI 10.1007/s00134-003-2075-6
    • Lichtenstein DA, Lascols N, Mezière G, Gepner A. Ultrasound diagnosis of alveolar consolidation in the critically ill. Intensive Care Med. 2004;30(2):276-281. (Pubitemid 38253419)
    • (2004) Intensive Care Medicine , vol.30 , Issue.2 , pp. 276-281
    • Lichtenstein, D.A.1    Lascols, N.2    Meziere, G.3    Gepner, A.4
  • 10
    • 79953818053 scopus 로고    scopus 로고
    • Realtime lung ultrasound for the diagnosis of alveolar consolidation and interstitial syndrome in the emergency department
    • Volpicelli G, Silva F, Radeos M . Realtime lung ultrasound for the diagnosis of alveolar consolidation and interstitial syndrome in the emergency department. Eur J Emerg Med. 2010;17(2):63-72.
    • (2010) Eur J Emerg Med , vol.17 , Issue.2 , pp. 63-72
    • Volpicelli, G.1    Silva, F.2    Radeos, M.3
  • 11
    • 84898841201 scopus 로고    scopus 로고
    • Lung ultrasonography for the diagnosis of neonatal lung disease
    • Liu J. Lung ultrasonography for the diagnosis of neonatal lung disease. J Matern Fetal Neonatal Med. 2014;27(8):856-861.
    • (2014) J Matern Fetal Neonatal Med , vol.27 , Issue.8 , pp. 856-861
    • Liu, J.1
  • 12
    • 0346964475 scopus 로고    scopus 로고
    • The "lung pulse": An early ultrasound sign of complete atelectasis
    • DOI 10.1007/s00134-003-1930-9
    • Lichtenstein DA, Lascols N, Prin S, Mezière G . The "lung pulse": an early ultrasound sign of complete atelectasis. Intensive Care Med. 2003;29(12):2187-2192. (Pubitemid 38030670)
    • (2003) Intensive Care Medicine , vol.29 , Issue.12 , pp. 2187-2192
    • Lichtenstein, D.A.1    Lascols, N.2    Prin, S.3    Meziere, G.4
  • 13
    • 84862515701 scopus 로고    scopus 로고
    • International evidence-based recommendations for point-of-care lung ultrasound
    • International Liaison Committee on Lung Ultrasound (ILC-LUS) for International Consensus Conference on Lung Ultrasound (ICC-LUS)
    • Volpicelli G, Elbarbary M, Blaivas M, et al; International Liaison Committee on Lung Ultrasound (ILC-LUS) for International Consensus Conference on Lung Ultrasound (ICC-LUS). International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med. 2012;38(4):577-591.
    • (2012) Intensive Care Med , vol.38 , Issue.4 , pp. 577-591
    • Volpicelli, G.1    Elbarbary, M.2    Blaivas, M.3
  • 14
    • 84891691342 scopus 로고    scopus 로고
    • International perspectives: Point-of-care chest ultrasound in the neonatal intensive care unit: An Italian perspective
    • Raimondi F, Cattarossi L, Copetti R. International perspectives: point-of-care chest ultrasound in the neonatal intensive care unit: an Italian perspective. Neoreviews. 2014;15(1):e2-e6.
    • (2014) Neoreviews , vol.15 , Issue.1
    • Raimondi, F.1    Cattarossi, L.2    Copetti, R.3
  • 15
    • 41249102737 scopus 로고    scopus 로고
    • Lung ultrasound in respiratory distress syndrome: A useful tool for early diagnosis
    • DOI 10.1159/000113059
    • Copetti R, Cattarossi L, Macagno F, Violino M, Furlan R. Lung ultrasound in respiratory distress syndrome: a useful tool for early diagnosis. Neonatology. 2008;94(1):52-59. (Pubitemid 351896595)
    • (2008) Neonatology , vol.94 , Issue.1 , pp. 52-59
    • Copetti, R.1    Cattarossi, L.2    Macagno, F.3    Violino, M.4    Furlan, R.5
  • 16
  • 18
    • 84871751009 scopus 로고    scopus 로고
    • Lung sonography
    • Volpicelli G. Lung sonography. J Ultrasound Med. 2013;32(1):165-171.
    • (2013) J Ultrasound Med , vol.32 , Issue.1 , pp. 165-171
    • Volpicelli, G.1
  • 19
    • 84884211464 scopus 로고    scopus 로고
    • Lung water assessment by lung ultrasonography in intensive care: A pilot study
    • Baldi G, Gargani L, Abramo A, et al. Lung water assessment by lung ultrasonography in intensive care: a pilot study. Intensive Care Med. 2013;39(1):74-84.
    • (2013) Intensive Care Med , vol.39 , Issue.1 , pp. 74-84
    • Baldi, G.1    Gargani, L.2    Abramo, A.3
  • 20
    • 84876233972 scopus 로고    scopus 로고
    • Measurement of alveolar recruitment at the bedside: The beginning of a new era in respiratory monitoring?
    • Rouby JJ, Arbelot C, Brisson H, Lu Q, Bouhemad B. Measurement of alveolar recruitment at the bedside: the beginning of a new era in respiratory monitoring? Respir Care. 2013;58(3):539-542.
    • (2013) Respir Care , vol.58 , Issue.3 , pp. 539-542
    • Rouby, J.J.1    Arbelot, C.2    Brisson, H.3    Lu, Q.4    Bouhemad, B.5
  • 21
    • 84868680666 scopus 로고    scopus 로고
    • Can neonatal lung ultrasound monitor fluid clearance and predict the need of respiratory support?
    • Raimondi F, Migliaro F, Sodano A, et al. Can neonatal lung ultrasound monitor fluid clearance and predict the need of respiratory support? Crit Care. 2012;16(6):R220.
    • (2012) Crit Care , vol.16 , Issue.6
    • Raimondi, F.1    Migliaro, F.2    Sodano, A.3
  • 22
    • 84862699256 scopus 로고    scopus 로고
    • Minimizing and communicating radiation risk in pediatric nuclear medicine
    • Fahey FH, Treves ST, Adelstein SJ. Minimizing and communicating radiation risk in pediatric nuclear medicine. J Nucl Med Technol. 2012;40(1):13-24.
    • (2012) J Nucl Med Technol , vol.40 , Issue.1 , pp. 13-24
    • Fahey, F.H.1    Treves, S.T.2    Adelstein, S.J.3
  • 23
    • 77956476647 scopus 로고    scopus 로고
    • Surfactant administration for neonatal respiratory distress does not improve lung interstitial fluid clearance: Echographic and experimental evidence
    • Cattarossi L, Copetti R, Poskurica B, Miserocchi G. Surfactant administration for neonatal respiratory distress does not improve lung interstitial fluid clearance: echographic and experimental evidence. J Perinat Med. 2010;38(5):557-563.
    • (2010) J Perinat Med , vol.38 , Issue.5 , pp. 557-563
    • Cattarossi, L.1    Copetti, R.2    Poskurica, B.3    Miserocchi, G.4
  • 24
    • 77954230504 scopus 로고    scopus 로고
    • Is computed tomography safe?
    • Smith-Bindman R . Is computed tomography safe? N Engl J Med. 2010;363(1):1-4.
    • (2010) N Engl J Med , vol.363 , Issue.1 , pp. 1-4
    • Smith-Bindman, R.1
  • 25
    • 79952215353 scopus 로고    scopus 로고
    • Radiation exposure early in life can be reduced by lung ultrasound
    • Cattarossi L, Copetti R, Poskurica B. Radiation exposure early in life can be reduced by lung ultrasound. Chest. 2011;139(3):730-731.
    • (2011) Chest , vol.139 , Issue.3 , pp. 730-731
    • Cattarossi, L.1    Copetti, R.2    Poskurica, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.