메뉴 건너뛰기




Volumn 41, Issue SUPPL. 1, 2014, Pages

Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality

Author keywords

Quantitative; SPECT

Indexed keywords

ARTICLE; ATTENUATION; CALIBRATION; COMPUTER ASSISTED TOMOGRAPHY; DENSITY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; EMISSION TOMOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE RECONSTRUCTION; LIGHT SCATTERING; POSITRON CAMERA; POSITRON EMISSION TOMOGRAPHY; QUANTITATIVE ANALYSIS; RADIOISOTOPE DECAY; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; DEVICES; GAMMA CAMERA; MULTIMODAL IMAGING; PROCEDURES; STATISTICAL ANALYSIS;

EID: 84905577677     PISSN: 16197070     EISSN: 16197089     Source Type: Journal    
DOI: 10.1007/s00259-013-2542-4     Document Type: Article
Times cited : (158)

References (46)
  • 1
    • 84864757306 scopus 로고    scopus 로고
    • Clinical PET of neuroendocrine tumors using 64Cu-DOTATATE: First-in-humans study
    • PubMed PMID: 22782315. Epub 2012/07/12. eng
    • Pfeifer A, Knigge U, Mortensen J, Oturai P, Berthelsen AK, Loft A, et al. Clinical PET of neuroendocrine tumors using 64Cu-DOTATATE: first-in-humans study. J Nucl Med 2012;53(8):1207-15. PubMed PMID: 22782315. Epub 2012/07/12. eng.
    • (2012) J Nucl Med , vol.53 , Issue.8 , pp. 1207-1215
    • Pfeifer, A.1    Knigge, U.2    Mortensen, J.3    Oturai, P.4    Berthelsen, A.K.5    Loft, A.6
  • 2
    • 0017452940 scopus 로고
    • A method for attenuation correction in radionuclide computed tomography
    • Chang LT. A method for attenuation correction in radionuclide computed tomography. IEEE Trans Nucl Sci 1978;20-25:638-43.
    • (1978) IEEE Trans Nucl Sci , vol.20-25 , pp. 638-643
    • Chang, L.T.1
  • 3
    • 0023243756 scopus 로고
    • Improved SPECT using simultaneous emission and transmission tomography
    • Bailey DL, Hutton BF, Walker PJ. Improved SPECT using simultaneous emission and transmission tomography. J Nucl Med 1987;28(5):844-51.
    • (1987) J Nucl Med , vol.28 , Issue.5 , pp. 844-851
    • Bailey, D.L.1    Hutton, B.F.2    Walker, P.J.3
  • 4
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982;2-1:113-22.
    • (1982) IEEE Trans Med Imaging , vol.2-11 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 5
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994; MI-13(4):601-9.
    • (1994) IEEE Trans Med Imaging , vol.MI-13 , Issue.4 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 6
    • 0031847790 scopus 로고    scopus 로고
    • Transmission scanning in emission tomography
    • Bailey DL. Transmission scanning in emission tomography. Eur J Nucl Med 1998;25(7):774-87.
    • (1998) Eur J Nucl Med , vol.25 , Issue.7 , pp. 774-787
    • Bailey, D.L.1
  • 7
    • 0012647040 scopus 로고
    • Attenuation compensation
    • Ell PJ, Holman BL, editors, London: Oxford University Press
    • Moore SC. Attenuation compensation. In: Ell PJ, Holman BL, editors. Computed emission tomography. London: Oxford University Press; 1982. p. 339-60.
    • (1982) Computed Emission Tomography , pp. 339-360
    • Moore, S.C.1
  • 8
    • 0024549419 scopus 로고
    • A technique for using CT images in attenuation correction and quantification in SPECT
    • Fleming JS. A technique for using CT images in attenuation correction and quantification in SPECT. Nucl Med Commun 1989;10:83-97.
    • (1989) Nucl Med Commun , vol.10 , pp. 83-97
    • Fleming, J.S.1
  • 9
    • 0028711780 scopus 로고
    • Investigation of the use of X-ray CT images for attenuation compensation in SPECT
    • La Croix KJ, Tsui B M W, Hasegawa BH, Brown JK. Investigation of the use of X-ray CT images for attenuation compensation in SPECT. IEEE Trans Nucl Sci 1994;41(6):2793-9.
    • (1994) IEEE Trans Nucl Sci , vol.41 , Issue.6 , pp. 2793-2799
    • La Croix, K.J.1    Tsui, B.M.W.2    Hasegawa, B.H.3    Brown, J.K.4
  • 10
    • 45949110209 scopus 로고    scopus 로고
    • Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT
    • Brown S, Bailey DL, Willowson K, Baldock CA. Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT. Appl Radiat Isot 2008;66(9):1206-12.
    • (2008) Appl Radiat Isot , vol.66 , Issue.9 , pp. 1206-1212
    • Brown, S.1    Bailey, D.L.2    Willowson, K.3    Baldock, C.A.4
  • 11
    • 34548145140 scopus 로고    scopus 로고
    • Development of a cost-effective modular SPECT/CT scanner
    • PubMed PMID:17372731. Epub 2007/03/21. eng
    • Bailey DL, Roach PJ, Bailey EA, Hewlett J, Keijzers R. Development of a cost-effective modular SPECT/CT scanner. Eur J Nucl Med Mol Imaging 2007;34(9):1415-26. PubMed PMID:17372731. Epub 2007/03/21. eng.
    • (2007) Eur J Nucl Med Mol Imaging , vol.34 , Issue.9 , pp. 1415-1426
    • Bailey, D.L.1    Roach, P.J.2    Bailey, E.A.3    Hewlett, J.4    Keijzers, R.5
  • 13
    • 0030216396 scopus 로고    scopus 로고
    • Attenuation correction of SPECT using X-ray CT on an emissiontransmission CT system: Myocardial perfusion assessment
    • Blankespoor S, Xu X, Kaiki K, Brown JK, Tang HR, Cann CE, et al. Attenuation correction of SPECT using X-ray CT on an emissiontransmission CT system: myocardial perfusion assessment. IEEE Trans Nucl Sci 1996;43(4):2263-74.
    • (1996) IEEE Trans Nucl Sci , vol.43 , Issue.4 , pp. 2263-2274
    • Blankespoor, S.1    Xu, X.2    Kaiki, K.3    Brown, J.K.4    Tang, H.R.5    Cann, C.E.6
  • 14
    • 0142094995 scopus 로고    scopus 로고
    • A generalized model for the conversion from CT numbers to linear attenuation coefficients
    • Bai C, Shao L, Da Silva A, Zhao Z. A generalized model for the conversion from CT numbers to linear attenuation coefficients. IEEE Trans Nucl Sci 2003;50(5):1510-5.
    • (2003) IEEE Trans Nucl Sci , vol.50 , Issue.5 , pp. 1510-1515
    • Bai, C.1    Shao, L.2    Da Silva, A.3    Zhao, Z.4
  • 15
    • 1542650092 scopus 로고    scopus 로고
    • A method for attenuation and scatter correction of brain SPECT based on computed tomography images
    • Larsson A, Johansson L, Sundström T, Riklund-Ahlström K. A method for attenuation and scatter correction of brain SPECT based on computed tomography images. Nucl Med Commun 2003;24:411-20.
    • (2003) Nucl Med Commun , vol.24 , pp. 411-420
    • Larsson, A.1    Johansson, L.2    Sundström, T.3    Riklund-Ahlström, K.4
  • 16
    • 0030788382 scopus 로고    scopus 로고
    • Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation study
    • PubMed PMID: 9279910. Epub 1997/08/01.eng
    • Beekman FJ, Kamphuis C, Frey EC. Scatter compensation methods in 3D iterative SPECT reconstruction: a simulation study. Phys Med Biol 1997;42(8):1619-32. PubMed PMID: 9279910. Epub 1997/08/01.eng.
    • (1997) Phys Med Biol , vol.42 , Issue.8 , pp. 1619-1632
    • Beekman, F.J.1    Kamphuis, C.2    Frey, E.C.3
  • 17
    • 0031980980 scopus 로고    scopus 로고
    • Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction
    • PubMed PMID: 9572510. Pubmed Central PMCID: 2808130. Epub 1998/05/08. eng
    • Kadrmas DJ, Frey EC, Karimi SS, Tsui BM. Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction. Phys Med Biol 1998;43(4):857-73. PubMed PMID: 9572510. Pubmed Central PMCID: 2808130. Epub 1998/05/08. eng.
    • (1998) Phys Med Biol , vol.43 , Issue.4 , pp. 857-873
    • Kadrmas, D.J.1    Frey, E.C.2    Karimi, S.S.3    Tsui, B.M.4
  • 18
    • 0029084607 scopus 로고
    • Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations
    • Buvat I, Rodrigues-Villafuerte M, Todd-Pokropek A, Benali H, Di Paola R. Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations. J Nucl Med 1995;36:1476-88.
    • (1995) J Nucl Med , vol.36 , pp. 1476-1488
    • Buvat, I.1    Rodrigues-Villafuerte, M.2    Todd-Pokropek, A.3    Benali, H.4    Di Paola, R.5
  • 19
    • 0033844081 scopus 로고    scopus 로고
    • Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT
    • El Fakhri G, Buvat I, Benali H, Todd-Pokropek AE, Di Paola R. Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT. J Nucl Med 2000;41(8):1400-8.
    • (2000) J Nucl Med , vol.41 , Issue.8 , pp. 1400-1408
    • El Fakhri, G.1    Buvat, I.2    Benali, H.3    Todd-Pokropek, A.E.4    Di Paola, R.5
  • 21
    • 0027142492 scopus 로고
    • Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT
    • PubMed PMID: 8254414. Epub 1993/12/01. eng
    • Ichihara T, Ogawa K, Motomura N, Kubo A, Hashimoto S. Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT. J Nucl Med 1993;34(12):2216-21. PubMed PMID: 8254414. Epub 1993/12/01. eng.
    • (1993) J Nucl Med , vol.34 , Issue.12 , pp. 2216-2221
    • Ichihara, T.1    Ogawa, K.2    Motomura, N.3    Kubo, A.4    Hashimoto, S.5
  • 22
    • 45949098655 scopus 로고    scopus 로고
    • Quantitative SPECT reconstruction using CT-derived corrections
    • Willowson K, Bailey DL, Baldock C. Quantitative SPECT reconstruction using CT-derived corrections. Phys Med Biol 2008;53:3099-112.
    • (2008) Phys Med Biol , vol.53 , pp. 3099-3112
    • Willowson, K.1    Bailey, D.L.2    Baldock, C.3
  • 23
    • 0027955827 scopus 로고
    • A transmission-dependent method for scatter correction in SPECT
    • Meikle SR, Hutton BF, Bailey DL. A transmission-dependent method for scatter correction in SPECT. J Nucl Med 1994;35(2):360-7.
    • (1994) J Nucl Med , vol.35 , Issue.2 , pp. 360-367
    • Meikle, S.R.1    Hutton, B.F.2    Bailey, D.L.3
  • 24
    • 0021260951 scopus 로고
    • Subtraction of Compton-scattered photons in single-photon emission computerized tomography
    • Axelsson B, Msaki P, Israelsson A. Subtraction of Compton-scattered photons in single-photon emission computerized tomography. J Nucl Med 1984;25:490-4.
    • (1984) J Nucl Med , vol.25 , pp. 490-494
    • Axelsson, B.1    Msaki, P.2    Israelsson, A.3
  • 25
    • 0023584327 scopus 로고
    • Generalized scatter correction method in SPECT using point scatter distribution functions
    • Msaki P, Axelsson B, Dahl CM, Larsson SA. Generalized scatter correction method in SPECT using point scatter distribution functions. J Nucl Med 1987;28:1861-9.
    • (1987) J Nucl Med , vol.28 , pp. 1861-1869
    • Msaki, P.1    Axelsson, B.2    Dahl, C.M.3    Larsson, S.A.4
  • 26
    • 0027272590 scopus 로고
    • The convolution scatter subtraction hypothesis and its validity domain in radioisotope imaging
    • Msaki P, Erlandsson K, Svensson L, Nolstedt L. The convolution scatter subtraction hypothesis and its validity domain in radioisotope imaging. Phys Med Biol 1993;38:1359-70.
    • (1993) Phys Med Biol , vol.38 , pp. 1359-1370
    • Msaki, P.1    Erlandsson, K.2    Svensson, L.3    Nolstedt, L.4
  • 27
    • 0038315472 scopus 로고    scopus 로고
    • Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities
    • Kim KM, Varrone A, Watabe H, Shidahara M, Fujita M, Innis RB, et al. Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities. J Nucl Med 2003;44(4):512-9.
    • (2003) J Nucl Med , vol.44 , Issue.4 , pp. 512-519
    • Kim, K.M.1    Varrone, A.2    Watabe, H.3    Shidahara, M.4    Fujita, M.5    Innis, R.B.6
  • 28
    • 0029969069 scopus 로고    scopus 로고
    • Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT
    • Narita Y, Eberl S, Iida H, Hutton BF, Braun M, Nakamura T, et al. Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT. Phys Med Biol 1996;41:2481-96.
    • (1996) Phys Med Biol , vol.41 , pp. 2481-2496
    • Narita, Y.1    Eberl, S.2    Iida, H.3    Hutton, B.F.4    Braun, M.5    Nakamura, T.6
  • 29
    • 0000067537 scopus 로고
    • Development of an iterative scatter correction technique for SPECT
    • Abstract
    • Bailey DL, Hutton BF, Meikle SR. Development of an iterative scatter correction technique for SPECT. Aust N Z J Med 1988;18:501. Abstract.
    • (1988) Aust N z J Med , vol.18 , pp. 501
    • Bailey, D.L.1    Hutton, B.F.2    Meikle, S.R.3
  • 30
    • 0025773696 scopus 로고
    • Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: A Monte Carlo study
    • Ljungberg M, Strand S-E. Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a Monte Carlo study. J Nucl Med 1991;32:1278-84.
    • (1991) J Nucl Med , vol.32 , pp. 1278-1284
    • Ljungberg, M.1    Strand, S.-E.2
  • 31
    • 0023676886 scopus 로고
    • Scatter correction in SPECT using non-uniform attenuation data
    • Mukai T, Links JM, Douglass KH, Wagner Jr HN. Scatter correction in SPECT using non-uniform attenuation data. Phys Med Biol 1988;33(10):1129-40.
    • (1988) Phys Med Biol , vol.33 , Issue.10 , pp. 1129-1140
    • Mukai, T.1    Links, J.M.2    Douglass, K.H.3    Wagner Jr., H.N.4
  • 32
    • 0025256947 scopus 로고
    • Attenuation correction in SPECT based on transmission studies and Monte Carlo simulations of build-up functions
    • Ljungberg M, Strand S-E. Attenuation correction in SPECT based on transmission studies and Monte Carlo simulations of build-up functions. J Nucl Med 1990;31:493-500.
    • (1990) J Nucl Med , vol.31 , pp. 493-500
    • Ljungberg, M.1    Strand, S.-E.2
  • 33
    • 0021235693 scopus 로고
    • Absolute left ventricular volume by an iterative build-up factor analysis of gated radionuclide images
    • Siegel JA, Maurer AH, Wu RK, Blasius KM, Denenberg BS, Gash AK, et al. Absolute left ventricular volume by an iterative build-up factor analysis of gated radionuclide images. Radiology 1984;151:477-81.
    • (1984) Radiology , vol.151 , pp. 477-481
    • Siegel, J.A.1    Maurer, A.H.2    Wu, R.K.3    Blasius, K.M.4    Denenberg, B.S.5    Gash, A.K.6
  • 34
    • 0031907419 scopus 로고    scopus 로고
    • Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT
    • Iida H, Narita Y, Kado H, Kashikura A, Sugawara S, Shoji Y, et al. Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT. J Nucl Med 1998;39(1):181-9.
    • (1998) J Nucl Med , vol.39 , Issue.1 , pp. 181-189
    • Iida, H.1    Narita, Y.2    Kado, H.3    Kashikura, A.4    Sugawara, S.5    Shoji, Y.6
  • 35
    • 0035355181 scopus 로고    scopus 로고
    • SPECT collimator dependency of scatter and validation of transmissiondependent scatter compensation methodologies
    • June
    • Kim KM, Watabe H, Shidahara M, Ishida Y, Iida H. SPECT collimator dependency of scatter and validation of transmissiondependent scatter compensation methodologies. IEEE Trans Nucl Sci 2001;NS-48(June):689-96.
    • (2001) IEEE Trans Nucl Sci , vol.NS-48 , pp. 689-696
    • Kim, K.M.1    Watabe, H.2    Shidahara, M.3    Ishida, Y.4    Iida, H.5
  • 36
    • 0344898289 scopus 로고    scopus 로고
    • Scatter-to-primary based scatter fractions for transmission-dependent convolution subtraction of SPECT images
    • Larsson A, Johansson L. Scatter-to-primary based scatter fractions for transmission-dependent convolution subtraction of SPECT images. Phys Med Biol 2003;48(21):N323-8.
    • (2003) Phys Med Biol , vol.48 , Issue.21
    • Larsson, A.1    Johansson, L.2
  • 37
    • 79960518170 scopus 로고    scopus 로고
    • Quantitative (177) Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT system
    • PubMed PMID: 21684829. Pubmed Central PMCID: 3205754. Epub 2011/06/21. eng
    • Beauregard JM, Hofman MS, Pereira JM, Eu P, Hicks RJ. Quantitative (177) Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT system. Cancer Imaging 2011;11:56-66. PubMed PMID: 21684829. Pubmed Central PMCID: 3205754. Epub 2011/06/21. eng.
    • (2011) Cancer Imaging , vol.11 , pp. 56-66
    • Beauregard, J.M.1    Hofman, M.S.2    Pereira, J.M.3    Eu, P.4    Hicks, R.J.5
  • 38
    • 0018902018 scopus 로고
    • Correction for deadtime losses in a gamma camera/data analysis system
    • Cranley K, Millar R, Bell T. Correction for deadtime losses in a gamma camera/data analysis system. Eur J Nucl Med 1980;5:377-82.
    • (1980) Eur J Nucl Med , vol.5 , pp. 377-382
    • Cranley, K.1    Millar, R.2    Bell, T.3
  • 39
    • 77953939468 scopus 로고    scopus 로고
    • Quantitative accuracy of clinical 99mTc SPECT/CT using ordered-subset expectation maximization with 3-dimensional resolution recovery, attenuation, and scatter correction
    • PubMed PMID: 20484423
    • Zeintl J, Vija AH, Yahil A, Hornegger J, Kuwert T. Quantitative accuracy of clinical 99mTc SPECT/CT using ordered-subset expectation maximization with 3-dimensional resolution recovery, attenuation, and scatter correction. J Nucl Med 2010;51(6):921-8. PubMed PMID: 20484423.
    • (2010) J Nucl Med , vol.51 , Issue.6 , pp. 921-928
    • Zeintl, J.1    Vija, A.H.2    Yahil, A.3    Hornegger, J.4    Kuwert, T.5
  • 40
    • 0025800480 scopus 로고
    • A method for measuring the absolute sensitivity of positron emission tomographic scanners
    • Bailey DL, Jones T, Spinks TJ. A method for measuring the absolute sensitivity of positron emission tomographic scanners. Eur J Nucl Med 1991;18:374-9.
    • (1991) Eur J Nucl Med , vol.18 , pp. 374-379
    • Bailey, D.L.1    Jones, T.2    Spinks, T.J.3
  • 41
    • 0018367149 scopus 로고
    • Quantitation in positron emission tomography: 1. Effect of object size
    • Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission tomography: 1. Effect of object size. J Comput Assist Tomogr 1979;3(3):299-308.
    • (1979) J Comput Assist Tomogr , vol.3 , Issue.3 , pp. 299-308
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3
  • 42
    • 84872047523 scopus 로고    scopus 로고
    • An evidence-based review of quantitative SPECT imaging and potential clinical applications
    • Bailey DL, Willowson KP. An evidence-based review of quantitative SPECT imaging and potential clinical applications. J Nucl Med 2013;54(1):83-9.
    • (2013) J Nucl Med , vol.54 , Issue.1 , pp. 83-89
    • Bailey, D.L.1    Willowson, K.P.2
  • 44
    • 79851498051 scopus 로고    scopus 로고
    • Multicenter evaluation of a standardized protocol for rest and acetazolamide cerebral blood flow assessment using a quantitative SPECT reconstruction program and split-dose 123I-iodoamphetamine
    • PubMed PMID: 20847163. Epub 2010/09/18. eng
    • Iida H, Nakagawara J, Hayashida K, Fukushima K, Watabe H, Koshino K, et al. Multicenter evaluation of a standardized protocol for rest and acetazolamide cerebral blood flow assessment using a quantitative SPECT reconstruction program and split-dose 123I-iodoamphetamine. J Nucl Med 2010;51(10):1624-31. PubMed PMID: 20847163. Epub 2010/09/18. eng.
    • (2010) J Nucl Med , vol.51 , Issue.10 , pp. 1624-1631
    • Iida, H.1    Nakagawara, J.2    Hayashida, K.3    Fukushima, K.4    Watabe, H.5    Koshino, K.6
  • 45
    • 84881258785 scopus 로고    scopus 로고
    • Quantification of 99mTc-DPD concentration in the lumbar spine with SPECT/CT
    • PubMed PMID: 23738809, Pubmed Central PMCID: 3680030
    • Cachovan M, Vija AH, Hornegger J, Kuwert T. Quantification of 99mTc-DPD concentration in the lumbar spine with SPECT/CT. EJNMMI Res 2013;3(1):45. PubMed PMID: 23738809. Pubmed Central PMCID: 3680030.
    • (2013) EJNMMI Res , vol.3 , Issue.1 , pp. 45
    • Cachovan, M.1    Vija, A.H.2    Hornegger, J.3    Kuwert, T.4
  • 46
    • 51849141433 scopus 로고    scopus 로고
    • Accuracy of quantitative reconstructions in SPECT/CT imaging
    • PubMed PMID: 18678930. Epub 2008/08/06. eng
    • Shcherbinin S, Celler A, Belhocine T, Vanderwerf R, Driedger A. Accuracy of quantitative reconstructions in SPECT/CT imaging. Phys Med Biol 2008;53(17):4595-604. PubMed PMID: 18678930. Epub 2008/08/06. eng.
    • (2008) Phys Med Biol , vol.53 , Issue.17 , pp. 4595-4604
    • Shcherbinin, S.1    Celler, A.2    Belhocine, T.3    Vanderwerf, R.4    Driedger, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.