-
1
-
-
0026618885
-
Primary posterior fusion C 1/2 in odontoid fractures: Indications, technique, and results of transarticular screw fixation
-
B. Jeanneret, and F. Magerl Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation J Spinal Disord 5 1992 464 475 (Pubitemid 23001672)
-
(1992)
Journal of Spinal Disorders
, vol.5
, Issue.4
, pp. 464-475
-
-
Jeanneret, B.1
Magerl, F.2
-
2
-
-
41749110491
-
Laminar screw fixation of the axis
-
DOI 10.3171/SPI/2008/8/4/327
-
D.M. Sciubba, J.C. Noggle, A.K. Vellimana, J.E. Conway, R.M. Kretzer, D.M. Long, and I.M. Garonzik Laminar screw fixation of the axis J Neurosurg Spine 8 2008 327 334 (Pubitemid 351489557)
-
(2008)
Journal of Neurosurgery: Spine
, vol.8
, Issue.4
, pp. 327-334
-
-
Sciubba, D.M.1
Noggle, J.C.2
Vellimana, A.K.3
Conway, J.E.4
Kretzer, R.M.5
Long, D.M.6
Garonzik, I.M.7
-
3
-
-
0028284239
-
Plate and screw fixation for atlanto-axial subluxation
-
DOI 10.1007/BF01400872
-
A. Goel, and V. Laheri Plate and screw fixation for atlanto-axial subluxation Acta Neurochir 129 1994 47 53 (Pubitemid 24225619)
-
(1994)
Acta Neurochirurgica
, vol.129
, Issue.1-2
, pp. 47-53
-
-
Goel, A.1
Laheri, V.2
-
4
-
-
0035890208
-
Posterior C1-C2 fusion with polyaxial screw and rod fixation
-
DOI 10.1097/00007632-200111150-00014
-
J. Harms, and R.P. Melcher Posterior C1-C2 fusion with polyaxial screw and rod fixation Spine 26 2001 2467 2471 (Pubitemid 33065058)
-
(2001)
Spine
, vol.26
, Issue.22
, pp. 2467-2471
-
-
Harms, J.1
Melcher, R.P.2
-
5
-
-
40949125097
-
Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: Modification of the Harms and Goel techniques
-
DOI 10.3171/SPI/2008/8/3/222
-
H.E. Aryan, C.B. Newman, E.W. Nottmeier, F.L. Acosta Jr., V.Y. Wang, and C.P. Ames Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques J Neurosurg Spine 8 2008 222 229 (Pubitemid 351413950)
-
(2008)
Journal of Neurosurgery: Spine
, vol.8
, Issue.3
, pp. 222-229
-
-
Aryan, H.E.1
Newman, C.B.2
Nottmeier, E.W.3
Acosta Jr., F.L.4
Wang, V.Y.5
Ames, C.P.6
-
6
-
-
0031010622
-
Cervical pedicle screws versus lateral mass screws: Anatomic feasibility and biomechanical comparison
-
DOI 10.1097/00007632-199705010-00009
-
E.L. Jones, J.G. Heller, D.H. Silcox, and W.C. Hutton Cervical pedicle screws versus lateral mass screws, anatomic feasibility and biomechanical comparison Spine 22 1997 977 982 (Pubitemid 27203488)
-
(1997)
Spine
, vol.22
, Issue.9
, pp. 977-982
-
-
Jones, E.L.1
Heller, J.G.2
Silcox, D.H.3
Hutton, W.C.4
-
7
-
-
84905173311
-
Cervical pedicle screw fixation
-
A.R. Vaccaro, E.M. Baron, Saunders Philadelphia, PA
-
K. Abumi, I. Manabu, and Y. Hojo Cervical pedicle screw fixation A.R. Vaccaro, E.M. Baron, Operative techniques: spine surgery 2012 Saunders Philadelphia, PA 108 125
-
(2012)
Operative Techniques: Spine Surgery
, pp. 108-125
-
-
Abumi, K.1
Manabu, I.2
Hojo, Y.3
-
8
-
-
68549122780
-
Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement
-
J.S. Yeom, J.M. Buchowski, K.W. Park, B.S. Chang, C.K. Lee, and K.D. Riew Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement Spine 33 2008 E942 E949
-
(2008)
Spine
, vol.33
-
-
Yeom, J.S.1
Buchowski, J.M.2
Park, K.W.3
Chang, B.S.4
Lee, C.K.5
Riew, K.D.6
-
9
-
-
67749139959
-
Radiographic and clinical evaluation of free-hand placement of C-2 pedicle screws
-
D.M. Sciubba, J.C. Noggle, A.K. Vellimana, H. Alosh, M.J. McGirt, Z.L. Gokaslan, and J.P. Wolinsky Radiographic and clinical evaluation of free-hand placement of C-2 pedicle screws J Neurosurg Spine 11 2009 15 22
-
(2009)
J Neurosurg Spine
, vol.11
, pp. 15-22
-
-
Sciubba, D.M.1
Noggle, J.C.2
Vellimana, A.K.3
Alosh, H.4
McGirt, M.J.5
Gokaslan, Z.L.6
Wolinsky, J.P.7
-
10
-
-
76649106408
-
Preoperative radiographic factors and surgeon experience are associated with cortical breach of C2 pedicle screws
-
H. Alosh, S.L. Parker, M.J. McGirt, Z.L. Gokaslan, T.F. Witham, A. Bydon, J.P. Wolinsky, and D.M. Sciubba Preoperative radiographic factors and surgeon experience are associated with cortical breach of C2 pedicle screws J Spinal Disord Tech 23 2010 9 14
-
(2010)
J Spinal Disord Tech
, vol.23
, pp. 9-14
-
-
Alosh, H.1
Parker, S.L.2
McGirt, M.J.3
Gokaslan, Z.L.4
Witham, T.F.5
Bydon, A.6
Wolinsky, J.P.7
Sciubba, D.M.8
-
11
-
-
0029869526
-
Anatomic consideration of C2 pedicle screw placement
-
DOI 10.1097/00007632-199603150-00005
-
N. Ebraheim, J.R. Rollins Jr., R. Xu, and W.T. Jackson Anatomic consideration of C2 pedicle screw placement Spine 21 1996 691 695 (Pubitemid 26088019)
-
(1996)
Spine
, vol.21
, Issue.6
, pp. 691-695
-
-
Ebraheim, N.1
Rollins Jr., J.R.2
Xu, R.3
Jackson, W.T.4
|