메뉴 건너뛰기




Volumn 50, Issue 2, 2014, Pages 159-163

Doppler sonography for the diagnosis of carpal tunnel syndrome: A critical review

Author keywords

Carpal tunnel syndrome; Diagnosis; Doppler sonography; Nerve conduction studies; Peripheral nervous system; Ultrasound

Indexed keywords

CARPAL TUNNEL SYNDROME; CLINICAL PRACTICE; DIAGNOSTIC TEST; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; DOPPLER ECHOGRAPHY; ECHOGRAPH; EVALUATION STUDY; HUMAN; NERVE COMPRESSION; PATHOPHYSIOLOGY; PRIORITY JOURNAL; REVIEW; STUDY DESIGN; SYSTEMATIC REVIEW (TOPIC); VASCULARIZATION;

EID: 84904693022     PISSN: 0148639X     EISSN: 10974598     Source Type: Journal    
DOI: 10.1002/mus.24241     Document Type: Review
Times cited : (52)

References (36)
  • 1
    • 80052873062 scopus 로고    scopus 로고
    • Diagnostic accuracy of ultrasonography vs electromyography in carpal tunnel syndrome: a systematic review of literature
    • Roll SC, Case-Smith J, Evans KD. Diagnostic accuracy of ultrasonography vs electromyography in carpal tunnel syndrome: a systematic review of literature. Ultrasound Med Biol 2011;37:1539-1553.
    • (2011) Ultrasound Med Biol , vol.37 , pp. 1539-1553
    • Roll, S.C.1    Case-Smith, J.2    Evans, K.D.3
  • 3
    • 0037062604 scopus 로고    scopus 로고
    • Practice parameter: electrodiagnostic studies in carpal tunnel syndrome: report of the American Association of Electrodiagnostic Medicine, American Academy of Neurology, and the American Academy of Physical Medicine and Rehabilitation
    • Jablecki CK, Andary MT, Floeter MK, Miller RG, Quartly CA, Vennix MJ, et al. Practice parameter: electrodiagnostic studies in carpal tunnel syndrome: report of the American Association of Electrodiagnostic Medicine, American Academy of Neurology, and the American Academy of Physical Medicine and Rehabilitation. Neurology 2002;58:1589-1592.
    • (2002) Neurology , vol.58 , pp. 1589-1592
    • Jablecki, C.K.1    Andary, M.T.2    Floeter, M.K.3    Miller, R.G.4    Quartly, C.A.5    Vennix, M.J.6
  • 4
    • 4644275742 scopus 로고    scopus 로고
    • The role of ultrasonographic measurements of the median nerve in the diagnosis of carpal tunnel syndrome
    • Yesildag A, Kutluhan S, Sengul N, Koyuncuoglu HR, Oyar O, Guler K, et al. The role of ultrasonographic measurements of the median nerve in the diagnosis of carpal tunnel syndrome. Clin Radiol 2004;59:910-915.
    • (2004) Clin Radiol , vol.59 , pp. 910-915
    • Yesildag, A.1    Kutluhan, S.2    Sengul, N.3    Koyuncuoglu, H.R.4    Oyar, O.5    Guler, K.6
  • 5
    • 0037233769 scopus 로고    scopus 로고
    • Sonography in the diagnosis of carpal tunnel syndrome: a critical review of the literature
    • Beekman R, Visser LH. Sonography in the diagnosis of carpal tunnel syndrome: a critical review of the literature. Muscle Nerve 2003;27:26-33.
    • (2003) Muscle Nerve , vol.27 , pp. 26-33
    • Beekman, R.1    Visser, L.H.2
  • 6
    • 84873043758 scopus 로고    scopus 로고
    • Ultrasound of peripheral nerves
    • Walker FO, Cartwright MS, editors. Philadelphia: Elsevier Saunders
    • Visser LH, Beekman R. Ultrasound of peripheral nerves. Walker FO, Cartwright MS, editors. Neuromuscular ultrasound. Philadelphia: Elsevier Saunders; 2011, p 30-31.
    • (2011) Neuromuscular ultrasound , pp. 30-31
    • Visser, L.H.1    Beekman, R.2
  • 7
    • 0032729344 scopus 로고    scopus 로고
    • Pathophysiology of nerve compression syndromes: response of peripheral nerves to loading
    • Rempel D, Dahlin L, Lundborg G. Pathophysiology of nerve compression syndromes: response of peripheral nerves to loading. J Bone Joint Surg Am 1999;81:1600-1610.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 1600-1610
    • Rempel, D.1    Dahlin, L.2    Lundborg, G.3
  • 8
    • 84904683100 scopus 로고    scopus 로고
    • Nerve fibers, peripheral nerves, receptor and effector endings, dermatomes, and muscle activity
    • Snell S., 7th ed. Baltimore: Wolters Kluwer / Lippincott Williams and Wilkins
    • Snell S. Nerve fibers, peripheral nerves, receptor and effector endings, dermatomes, and muscle activity. Snell S. Clinical neuroanatomy, 7th ed. Baltimore: Wolters Kluwer / Lippincott Williams and Wilkins; 2011. p 80.
    • (2011) Clinical neuroanatomy
    • Snell, S.1
  • 9
    • 0034821778 scopus 로고    scopus 로고
    • Correlation between the number of epineurial and endoneurial blood vessels in diseased human sural nerves
    • Mawrin C, Schutz G, Schroder JM. Correlation between the number of epineurial and endoneurial blood vessels in diseased human sural nerves. Acta Neuropathol 2001;102:364-372.
    • (2001) Acta Neuropathol , vol.102 , pp. 364-372
    • Mawrin, C.1    Schutz, G.2    Schroder, J.M.3
  • 10
    • 30544431966 scopus 로고    scopus 로고
    • Imaging of intraneural edema by using gadolinium-enhanced MR imaging: experimental compression injury
    • Kobayashi S, Meir A, Baba H, Uchida K, Hayakawa K. Imaging of intraneural edema by using gadolinium-enhanced MR imaging: experimental compression injury. AJNR Am J Neuroradiol 2005;26:973-980.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 973-980
    • Kobayashi, S.1    Meir, A.2    Baba, H.3    Uchida, K.4    Hayakawa, K.5
  • 11
    • 0030001968 scopus 로고    scopus 로고
    • Anatomy, function, and pathophysiology of peripheral nerves and nerve compression
    • Lundborg G, Dahlin LB. Anatomy, function, and pathophysiology of peripheral nerves and nerve compression. Hand Clin 1996;12:185-193.
    • (1996) Hand Clin , vol.12 , pp. 185-193
    • Lundborg, G.1    Dahlin, L.B.2
  • 12
    • 78549280210 scopus 로고    scopus 로고
    • Value of Power Doppler and Gray-Scale US in the diagnosis of carpal tunnel syndrome: contribution of cross-sectional area just before the tunnel inlet as compared with the cross-sectional area at the tunnel
    • Akcar N, Ozkan S, Mehmetoglu O, Calisir C, Adapinar B. Value of Power Doppler and Gray-Scale US in the diagnosis of carpal tunnel syndrome: contribution of cross-sectional area just before the tunnel inlet as compared with the cross-sectional area at the tunnel. Korean J Radiol 2010;11:632-639.
    • (2010) Korean J Radiol , vol.11 , pp. 632-639
    • Akcar, N.1    Ozkan, S.2    Mehmetoglu, O.3    Calisir, C.4    Adapinar, B.5
  • 14
    • 84904624699 scopus 로고    scopus 로고
    • Ultrasound, Dalrymple NC, Leyendecker JR, Oliphant M, editors. Philadelphia: Mosby Elsevier
    • Tchelepi H, Dalrymple NC, Ralls P. Ultrasound. Dalrymple NC, Leyendecker JR, Oliphant M, editors. Problem solving in abdominal imaging. Philadelphia: Mosby Elsevier; 2009. p 34.
    • (2009) Problem solving in abdominal imaging , pp. 34
    • Tchelepi, H.1    Dalrymple, N.C.2    Ralls, P.3
  • 15
    • 84904624766 scopus 로고    scopus 로고
    • Physical and technical principles of Color Doppler sonography
    • Schmidt W, Kurjak A, editors. Stuttgart: Thieme
    • Kubale R, Hetzel G. Physical and technical principles of Color Doppler sonography. Schmidt W, Kurjak A, editors. Color Doppler sonography in gynecology and obstetrics. Stuttgart: Thieme; 2005. p 13-15.
    • (2005) Color Doppler sonography in gynecology and obstetrics , pp. 13-15
    • Kubale, R.1    Hetzel, G.2
  • 16
    • 84904646046 scopus 로고    scopus 로고
    • Doppler ultrasound: principles and practice. Available at Accessed January 23, 2013.
    • Deane C. 2002. Doppler ultrasound: principles and practice. Available at http://www.centrus.com.br/DiplomaFMF/SeriesFMF/doppler/capitulos-html/chapter_01.htm. Accessed January 23, 2013.
    • (2002)
    • Deane, C.1
  • 17
    • 0036723920 scopus 로고    scopus 로고
    • The difference between Colour Doppler velocity imaging and Power Doppler imaging
    • Anderson T, McDicken WN. The difference between Colour Doppler velocity imaging and Power Doppler imaging. Eur J Echocardiogr 2002;3:240-244.
    • (2002) Eur J Echocardiogr , vol.3 , pp. 240-244
    • Anderson, T.1    McDicken, W.N.2
  • 18
    • 76849116496 scopus 로고    scopus 로고
    • Colour flow and motion imaging
    • Evans DH. Colour flow and motion imaging. Proc Inst Mech Eng H 2010;224:241-253.
    • (2010) Proc Inst Mech Eng H , vol.224 , pp. 241-253
    • Evans, D.H.1
  • 19
    • 84904667583 scopus 로고    scopus 로고
    • Hoskins P. Principles of Doppler ultrasound. Hoskins P, Martin K, Thrush A, editors., 2nd ed. Cambridge: Cambridge University Press
    • Hoskins P. Principles of Doppler ultrasound. Hoskins P, Martin K, Thrush A, editors. Diagnostic ultrasound: physics and equipment, 2nd ed. Cambridge: Cambridge University Press, 2010. p 84-90.
    • (2010) Diagnostic ultrasound: physics and equipment , pp. 84-90
  • 20
    • 84904679912 scopus 로고    scopus 로고
    • Ultrasound, Brown B, Shaw R, Martz B, editors., 3rd ed. Baltimore: Lippincott Williams and Wilkins
    • Huda W. Ultrasound. Brown B, Shaw R, Martz B, editors. Review of radiologic physics, 3rd ed. Baltimore: Lippincott Williams and Wilkins; 2010. p 170.
    • (2010) Review of radiologic physics , pp. 170
    • Huda, W.1
  • 22
    • 80054782414 scopus 로고    scopus 로고
    • Color and Power Doppler US for diagnosing carpal tunnel syndrome and determining its severity: a quantitative image processing method
    • Ghasemi-Esfe AR, Khalilzadeh O, Vaziri-Bozorg SM, Jajroudi M, Shakiba M, Mazloumi M, et al. Color and Power Doppler US for diagnosing carpal tunnel syndrome and determining its severity: a quantitative image processing method. Radiology 2011;261:499-506.
    • (2011) Radiology , vol.261 , pp. 499-506
    • Ghasemi-Esfe, A.R.1    Khalilzadeh, O.2    Vaziri-Bozorg, S.M.3    Jajroudi, M.4    Shakiba, M.5    Mazloumi, M.6
  • 23
    • 33745530235 scopus 로고    scopus 로고
    • Predictors of carpal tunnel syndrome: accuracy of Gray-Scale and Color Doppler sonography
    • Mallouhi A, Pulzl P, Trieb T, Piza H, Bodner G. Predictors of carpal tunnel syndrome: accuracy of Gray-Scale and Color Doppler sonography. AJR Am J Roentgenol 2006;186:1240-1245.
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 1240-1245
    • Mallouhi, A.1    Pulzl, P.2    Trieb, T.3    Piza, H.4    Bodner, G.5
  • 25
    • 84887418139 scopus 로고    scopus 로고
    • Ultrasound for diagnosis of carpal tunnel syndrome: comparison of different methods to determine median nerve volume and value of power Doppler sonography
    • Dejaco C, Stradner M, Zauner D, Seel W, Simmet N, et al. Ultrasound for diagnosis of carpal tunnel syndrome: comparison of different methods to determine median nerve volume and value of power Doppler sonography. Ann Rheum Dis 2013;72:1934-1939.
    • (2013) Ann Rheum Dis , vol.72 , pp. 1934-1939
    • Dejaco, C.1    Stradner, M.2    Zauner, D.3    Seel, W.4    Simmet, N.5
  • 26
    • 84864209650 scopus 로고    scopus 로고
    • Relationship between intraneural vascular flow measured with sonography and carpal tunnel syndrome diagnosis based on electrodiagnostic testing
    • Evans KD, Roll SC, Volz KR, Freimer M. Relationship between intraneural vascular flow measured with sonography and carpal tunnel syndrome diagnosis based on electrodiagnostic testing. J Ultrasound Med 2012;31:729-736.
    • (2012) J Ultrasound Med , vol.31 , pp. 729-736
    • Evans, K.D.1    Roll, S.C.2    Volz, K.R.3    Freimer, M.4
  • 27
    • 84856103045 scopus 로고    scopus 로고
    • Correlation between the severity of carpal tunnel syndrome and Color Doppler sonography findings
    • Mohammadi A, Ghasemi-Rad M, Mladkova-Suchy N, Ansari S. Correlation between the severity of carpal tunnel syndrome and Color Doppler sonography findings. AJR Am J Roentgenol 2012;198:W181-W184.
    • (2012) AJR Am J Roentgenol , vol.198
    • Mohammadi, A.1    Ghasemi-Rad, M.2    Mladkova-Suchy, N.3    Ansari, S.4
  • 28
    • 28244432840 scopus 로고    scopus 로고
    • Carpal tunnel syndrome: comparison of intra-operative structural changes with clinical and electrodiagnostic severity
    • Tuncali D, Yuksel Barutcu A, Terzioglu A, Aslan G. Carpal tunnel syndrome: comparison of intra-operative structural changes with clinical and electrodiagnostic severity. Br J Plast Surg 2005;58:1136-1142.
    • (2005) Br J Plast Surg , vol.58 , pp. 1136-1142
    • Tuncali, D.1    Yuksel Barutcu, A.2    Terzioglu, A.3    Aslan, G.4
  • 29
    • 15344351533 scopus 로고    scopus 로고
    • Schwann cells upregulate vascular endothelial growth factor secondary to chronic nerve compression injury
    • Gupta RG, Gray M, Chao T, Bear D, Modafferi E, Mozaffar T. Schwann cells upregulate vascular endothelial growth factor secondary to chronic nerve compression injury. Muscle Nerve 2005;31:452-460.
    • (2005) Muscle Nerve , vol.31 , pp. 452-460
    • Gupta, R.G.1    Gray, M.2    Chao, T.3    Bear, D.4    Modafferi, E.5    Mozaffar, T.6
  • 31
    • 84873034637 scopus 로고    scopus 로고
    • Increased nerve vascularisation detected by color Doppler sonography in patients with ulnar neuropathy at the elbow indicates axonal damage
    • Frijlink DW, Brekelmans GJ, Visser LH. Increased nerve vascularisation detected by color Doppler sonography in patients with ulnar neuropathy at the elbow indicates axonal damage. Muscle Nerve 2013;47:188-193.
    • (2013) Muscle Nerve , vol.47 , pp. 188-193
    • Frijlink, D.W.1    Brekelmans, G.J.2    Visser, L.H.3
  • 32
    • 84862320589 scopus 로고    scopus 로고
    • Morphological changes of the epineurium in leprosy: a new finding detected by high-resolution sonography
    • Visser LH, Jain S, Lokesh B, Suneetha S, Subbanna J. Morphological changes of the epineurium in leprosy: a new finding detected by high-resolution sonography. Muscle Nerve 2012;46:38-41.
    • (2012) Muscle Nerve , vol.46 , pp. 38-41
    • Visser, L.H.1    Jain, S.2    Lokesh, B.3    Suneetha, S.4    Subbanna, J.5
  • 33
    • 84871326770 scopus 로고    scopus 로고
    • Provocation tests in Doppler ultrasonography for carpal tunnel syndrome
    • Ng ES, Ng KW, Wilder-Smith EP. Provocation tests in Doppler ultrasonography for carpal tunnel syndrome. Muscle Nerve 2013;47:116-117.
    • (2013) Muscle Nerve , vol.47 , pp. 116-117
    • Ng, E.S.1    Ng, K.W.2    Wilder-Smith, E.P.3
  • 34
    • 84856352270 scopus 로고    scopus 로고
    • Morphologic characterization of intraneural flow associated with median nerve pathology
    • Evans K, Volz K, Hutmire C, Roll S. Morphologic characterization of intraneural flow associated with median nerve pathology. J Diagn Med Sonogr 2012;28:11-19.
    • (2012) J Diagn Med Sonogr , vol.28 , pp. 11-19
    • Evans, K.1    Volz, K.2    Hutmire, C.3    Roll, S.4
  • 35
    • 0035849531 scopus 로고    scopus 로고
    • Multiperspective follow-up of untreated carpal tunnel syndrome: a multicenter study
    • Padua L, Padua R, Aprile I, Pasqualetti P, Tonali P. Multiperspective follow-up of untreated carpal tunnel syndrome: a multicenter study. Neurology 2001;56:1459-1466.
    • (2001) Neurology , vol.56 , pp. 1459-1466
    • Padua, L.1    Padua, R.2    Aprile, I.3    Pasqualetti, P.4    Tonali, P.5
  • 36
    • 84904628543 scopus 로고    scopus 로고
    • Appendix 4: narrative classification of evidence schemes, diagnostic accuracy
    • American Academy of Neurology. Gronseth GS, Woodroffe LM, Getchius TSD, editors. Paul: AAN, p 37
    • American Academy of Neurology. Appendix 4: narrative classification of evidence schemes, diagnostic accuracy. Gronseth GS, Woodroffe LM, Getchius TSD, editors. Clinical practice guideline process manual. St. Paul: AAN; 2011. p 37, 39-40.
    • (2011) Clinical practice guideline process manual. St , pp. 39-40


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.