메뉴 건너뛰기




Volumn 61, Issue 8, 2014, Pages 736-740

Cannula malposition during antegrade cerebral perfusion for aortic surgery: Role of cerebral oximetry

Author keywords

[No Author keywords available]

Indexed keywords

OXYGEN; THIOPENTAL;

EID: 84904541976     PISSN: 0832610X     EISSN: 14968975     Source Type: Journal    
DOI: 10.1007/s12630-014-0181-2     Document Type: Article
Times cited : (15)

References (23)
  • 1
    • 84881613866 scopus 로고    scopus 로고
    • Moderate hypothermia during aortic arch surgery is associated with reduced risk of early mortality
    • Tsai JY, Pan W, Lemaire SA, et al. Moderate hypothermia during aortic arch surgery is associated with reduced risk of early mortality. J Thorac Cardiovasc Surg 2013; 146: 662-7.
    • (2013) J Thorac Cardiovasc Surg , vol.146 , pp. 662-667
    • Tsai, J.Y.1    Pan, W.2    Lemaire, S.A.3
  • 2
    • 84880738707 scopus 로고    scopus 로고
    • Does the use of thiopental provide added cerebral protection during deep hypothermic circulatory arrest?
    • Al-Hashimi S, Zaman M, Waterworth P, Bilal H. Does the use of thiopental provide added cerebral protection during deep hypothermic circulatory arrest? Inter Cardiovasc Thorac Surg 2013; 17: 392-7.
    • (2013) Inter Cardiovasc Thorac Surg , vol.17 , pp. 392-397
    • Al-Hashimi, S.1    Zaman, M.2    Waterworth, P.3    Bilal, H.4
  • 3
    • 84863296780 scopus 로고    scopus 로고
    • Cerebral perfusion in aortic arch surgery Antegrade, retrograde, or both?
    • Lee TY, Safi HJ, Estrera AL. Cerebral perfusion in aortic arch surgery Antegrade, retrograde, or both? Texas Heart Inst J 2011; 38: 674-7.
    • (2011) Texas Heart Inst J , vol.38 , pp. 674-677
    • Lee, T.Y.1    Safi, H.J.2    Estrera, A.L.3
  • 4
    • 84873717595 scopus 로고    scopus 로고
    • Total arch replacement using antegrade cerebral perfusion
    • Okita Y, Okada K, Omura A, et al. Total arch replacement using antegrade cerebral perfusion. J Thorac Cardiovasc Surg 2013; 145: S63-71.
    • (2013) J Thorac Cardiovasc Surg , vol.145
    • Okita, Y.1    Okada, K.2    Omura, A.3
  • 5
    • 84904577162 scopus 로고    scopus 로고
    • Surgical techniques of total arch replacement using selective antegrade cerebral perfusion
    • Okita Y, Okada K, Omura A, et al. Surgical techniques of total arch replacement using selective antegrade cerebral perfusion. Ann Cardiothorac Surg 2013; 2: 222-8.
    • (2013) Ann Cardiothorac Surg , vol.2 , pp. 222-228
    • Okita, Y.1    Okada, K.2    Omura, A.3
  • 6
    • 79951770259 scopus 로고    scopus 로고
    • Noninvasive cerebral oxygenation may predict outcome in patients undergoing aortic arch surgery
    • Fischer GW, Lin HM, Krol M, et al. Noninvasive cerebral oxygenation may predict outcome in patients undergoing aortic arch surgery. J Thorac Cardiovasc Surg 2011; 141: 815-21.
    • (2011) J Thorac Cardiovasc Surg , vol.141 , pp. 815-821
    • Fischer, G.W.1    Lin, H.M.2    Krol, M.3
  • 7
    • 84904580820 scopus 로고    scopus 로고
    • Guidelines to the practice of anesthesia
    • Revised edition 2014
    • Merchant R, Chartrand D, Dain S, et al. Guidelines to the practice of anesthesia - Revised edition 2014. Can J Anesth 2014; 61: 46-71.
    • (2014) Can J Anesth , vol.61 , pp. 46-71
    • Merchant, R.1    Chartrand, D.2    Dain, S.3
  • 8
    • 84859111411 scopus 로고    scopus 로고
    • Impact of extracranial contamination on regional cerebral oxygen saturation: A comparison of three cerebral oximetry technologies
    • Davie SN, Grocott HP. Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies. Anesthesiology 2012; 116: 834-40.
    • (2012) Anesthesiology , vol.116 , pp. 834-840
    • Davie, S.N.1    Grocott, H.P.2
  • 9
    • 79960476429 scopus 로고    scopus 로고
    • Effect of phenylephrine and ephedrine bolus treatment on cerebral oxygenation in anaesthetized patients
    • Meng L, Cannesson M, Alexander BS, et al. Effect of phenylephrine and ephedrine bolus treatment on cerebral oxygenation in anaesthetized patients. Br J Anaesth 2011; 107: 209-17.
    • (2011) Br J Anaesth , vol.107 , pp. 209-217
    • Meng, L.1    Cannesson, M.2    Alexander, B.S.3
  • 10
    • 15744365230 scopus 로고    scopus 로고
    • Malposition of selective cerebral perfusion catheter is not a rare event
    • DOI 10.1016/j.ejcts.2004.12.046
    • Orihashi K, Sueda T, Okada K, Imai K. Malposition of selective cerebral perfusion catheter is not a rare event. Eur J Cardiothorac Surg 2005; 27: 644-8. (Pubitemid 40409739)
    • (2005) European Journal of Cardio-thoracic Surgery , vol.27 , Issue.4 , pp. 644-648
    • Orihashi, K.1    Sueda, T.2    Okada, K.3    Imai, K.4
  • 11
    • 84866055504 scopus 로고    scopus 로고
    • Near-infrared spectroscopy-detected cerebral ischemia resolved by cannulation of an axillo-femoral graft during surgical repair of type A aortic dissection
    • Agostini M, Di Gregorio V, Bertora M, Avallato C, Locatelli A. Near-infrared spectroscopy-detected cerebral ischemia resolved by cannulation of an axillo-femoral graft during surgical repair of type A aortic dissection. Heart Surg Forum 2012; 15: E221-3.
    • (2012) Heart Surg Forum , vol.15
    • Agostini, M.1    Di Gregorio, V.2    Bertora, M.3    Avallato, C.4    Locatelli, A.5
  • 12
    • 0036240729 scopus 로고    scopus 로고
    • Unilateral cerebral oxygen desaturation during emergent repair of a DeBakey type 1 aortic dissection: Potential aversion of a major catastrophe
    • DOI 10.1097/00000542-200205000-00033
    • Janelle GM, Mnookin S, Gravenstein N, Martin TD, Urdaneta F. Unilateral cerebral oxygen desaturation during emergent repair of a DeBakey type 1 aortic dissection: potential aversion of a major catastrophe. Anesthesiology 2002; 96: 1263-5. (Pubitemid 34462591)
    • (2002) Anesthesiology , vol.96 , Issue.5 , pp. 1263-1265
    • Janelle, G.M.1    Mnookin, S.2    Gravenstein, N.3    Martin, T.D.4    Urdaneta, F.5
  • 13
    • 79952386882 scopus 로고    scopus 로고
    • Innominate artery dissection with presentation of sudden right frontal desaturation detected by cerebral oximetry in complicated thoracic aortic aneurysm repair surgery: A case report
    • Wang SC, Lo PH, Shen JL, et al. Innominate artery dissection with presentation of sudden right frontal desaturation detected by cerebral oximetry in complicated thoracic aortic aneurysm repair surgery: a case report. J Clin Anesth 2011; 23: 137-41.
    • (2011) J Clin Anesth , vol.23 , pp. 137-141
    • Wang, S.C.1    Lo, P.H.2    Shen, J.L.3
  • 14
    • 33745207764 scopus 로고    scopus 로고
    • Incomplete circle of Willis and right axillary artery perfusion
    • Merkkola P, Tulla H, Ronkainen A, et al. Incomplete circle of Willis and right axillary artery perfusion. Ann Thorac Surg 2006; 82: 74-9.
    • (2006) Ann Thorac Surg , vol.82 , pp. 74-79
    • Merkkola, P.1    Tulla, H.2    Ronkainen, A.3
  • 15
    • 77955459584 scopus 로고    scopus 로고
    • Aortic arch surgery using bilateral antegrade selective cerebral perfusion in combination with near-infrared spectroscopy
    • Harrer M, Waldenberger FR, Weiss G, et al. Aortic arch surgery using bilateral antegrade selective cerebral perfusion in combination with near-infrared spectroscopy. Eur J Cardiothorac Surg 2010; 38: 561-7.
    • (2010) Eur J Cardiothorac Surg , vol.38 , pp. 561-567
    • Harrer, M.1    Waldenberger, F.R.2    Weiss, G.3
  • 16
    • 84876686593 scopus 로고    scopus 로고
    • Cerebral near-infrared spectroscopy monitoring and neurologic outcomes in adult cardiac surgery patients: A systematic review
    • Zheng F, Sheinberg R, Yee MS, Ono M, Zheng Y, Hogue CW. Cerebral near-infrared spectroscopy monitoring and neurologic outcomes in adult cardiac surgery patients: a systematic review. Anesth Analg 2013; 116: 663-76.
    • (2013) Anesth Analg , vol.116 , pp. 663-676
    • Zheng, F.1    Sheinberg, R.2    Yee, M.S.3    Ono, M.4    Zheng, Y.5    Hogue, C.W.6
  • 17
    • 79952222538 scopus 로고    scopus 로고
    • Monitoring brain oxygen saturation during coronary bypass surgery improves outcomes in diabetic patients: A post hoc analysis
    • Murkin JM, Adams SJ, Pardy E, Quantz M, McKenzie FN, Guo L. Monitoring brain oxygen saturation during coronary bypass surgery improves outcomes in diabetic patients: a post hoc analysis. Heart Surg Forum 2011; 14: E1-6.
    • (2011) Heart Surg Forum , vol.14
    • Murkin, J.M.1    Adams, S.J.2    Pardy, E.3    Quantz, M.4    McKenzie, F.N.5    Guo, L.6
  • 19
    • 84888307774 scopus 로고    scopus 로고
    • Reversal of decreases in cerebral saturation in high-risk cardiac surgery
    • Deschamps A, Lambert J, Couture P, et al. Reversal of decreases in cerebral saturation in high-risk cardiac surgery. J Cardiothorac Vasc Anesth 2013; 27: 1260-6.
    • (2013) J Cardiothorac Vasc Anesth , vol.27 , pp. 1260-1266
    • Deschamps, A.1    Lambert, J.2    Couture, P.3
  • 20
    • 34247490995 scopus 로고    scopus 로고
    • Cerebral oxygen desaturation after cardiopulmonary bypass in a patient with raynaud's phenomenon detected by near-infrared cerebral oximetry
    • DOI 10.1213/01.ane.0000260265.53212.fe, PII 0000053920070500000008
    • Aron JH, Fink GW, Swartz MF, et al. Cerebral oxygen desaturation after cardiopulmonary bypass in a patient with Raynaud's phenomenon detected by near-infrared cerebral oximetry. Anesth Analg 2007; 104: 1034-6. (Pubitemid 46649918)
    • (2007) Anesthesia and Analgesia , vol.104 , Issue.5 , pp. 1034-1036
    • Aron, J.H.1    Fink, G.W.2    Swartz, M.F.3    Ford, B.4    Hauser, M.C.5    O'Leary, C.E.6    Puskas, F.7
  • 21
  • 22
    • 84858382815 scopus 로고    scopus 로고
    • Reduced cerebral oxygen saturation during thoracic surgery predicts early postoperative cognitive dysfunction
    • Tang L, Kazan R, Taddei R, Zaouter C, Cyr S, Hemmerling TM. Reduced cerebral oxygen saturation during thoracic surgery predicts early postoperative cognitive dysfunction. Br J Anaesth 2012; 108: 623-9.
    • (2012) Br J Anaesth , vol.108 , pp. 623-629
    • Tang, L.1    Kazan, R.2    Taddei, R.3    Zaouter, C.4    Cyr, S.5    Hemmerling, T.M.6
  • 23
    • 84855261151 scopus 로고    scopus 로고
    • Is near-infrared spectroscopy a reliable method to evaluate clamping ischemia during carotid surgery?
    • Pedrini L, Magnoni F, Sensi L, et al. Is near-infrared spectroscopy a reliable method to evaluate clamping ischemia during carotid surgery? Stroke Res Treat 2012; 2012: 156975.
    • (2012) Stroke Res Treat , vol.2012 , pp. 156975
    • Pedrini, L.1    Magnoni, F.2    Sensi, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.