메뉴 건너뛰기




Volumn 84, Issue 2, 2014, Pages 197-203

Implantation and preliminary follow-up of the Bard Valeo stent in pulmonary artery stenosis

Author keywords

congenital heart disease; pediatric intervention; pediatrics; stent design structure coatings; stent, bare metal; structural heart disease intervention

Indexed keywords

ADULT; ARTICLE; CARDIOVASCULAR RESPONSE; CHILD; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; FLUOROSCOPY; HEMODYNAMICS; HUMAN; PRESSURE GRADIENT; PULMONARY ARTERY STENOSIS; RETROSPECTIVE STUDY; SCHOOL CHILD; SYSTOLIC BLOOD PRESSURE; TREATMENT RESPONSE; VASCULAR STENT; ADOLESCENT; ADVERSE EFFECTS; ARTERIAL OCCLUSIVE DISEASES; ARTERIAL PRESSURE; DEVICES; INFANT; PATHOPHYSIOLOGY; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRESCHOOL CHILD; PROSTHESIS; PULMONARY ARTERY; RADIOGRAPHY; STENOSIS, OCCLUSION AND OBSTRUCTION; STENT; TIME; TREATMENT OUTCOME; VASCULAR PATENCY; YOUNG ADULT;

EID: 84904463954     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.25443     Document Type: Article
Times cited : (17)

References (16)
  • 2
    • 0034778878 scopus 로고    scopus 로고
    • A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits
    • Peuster M, Wohlsein P, Brugmann M, Ehlerding M, Seidler K, Fink C, Brauer H, Fischer A, Hausdorf G,. A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits. Heart 2001; 86: 563-569.
    • (2001) Heart , vol.86 , pp. 563-569
    • Peuster, M.1    Wohlsein, P.2    Brugmann, M.3    Ehlerding, M.4    Seidler, K.5    Fink, C.6    Brauer, H.7    Fischer, A.8    Hausdorf, G.9
  • 3
    • 28844455504 scopus 로고    scopus 로고
    • First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
    • Zartner P, Cesnjevar R, Singer H, Weyand M,. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby. Catheter Cardiovasc Interv 2005; 66: 590-594.
    • (2005) Catheter Cardiovasc Interv , vol.66 , pp. 590-594
    • Zartner, P.1    Cesnjevar, R.2    Singer, H.3    Weyand, M.4
  • 4
    • 34147224227 scopus 로고    scopus 로고
    • Early restenosis following biodegradable stent implantation in an aortopulmonary collateral of a patient with pulmonary atresia and hypoplastic pulmonary arteries
    • McMahon CJ, Oslizlok P, Walsh KP,. Early restenosis following biodegradable stent implantation in an aortopulmonary collateral of a patient with pulmonary atresia and hypoplastic pulmonary arteries. Catheter Cardiovasc Interv 2007; 69: 735-738.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 735-738
    • McMahon, C.J.1    Oslizlok, P.2    Walsh, K.P.3
  • 5
    • 33646265009 scopus 로고    scopus 로고
    • Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn
    • Schranz D, Zartner P, Michel-Behnke I, Akinturk H,. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn. Catheter Cardiovasc Interv 2006; 67: 671-673.
    • (2006) Catheter Cardiovasc Interv , vol.67 , pp. 671-673
    • Schranz, D.1    Zartner, P.2    Michel-Behnke, I.3    Akinturk, H.4
  • 6
    • 84893780863 scopus 로고    scopus 로고
    • A novel biodegradable stent applicable for use in congenital heart disease: Bench testing and feasibility results in a rabbit model
    • Reddy SR, Welch TR, Wang J, Bernstein F, Richardson JA, Forbess JM, Nugent AW,. A novel biodegradable stent applicable for use in congenital heart disease: Bench testing and feasibility results in a rabbit model. Catheter Cardiovasc Interv 2014; 83: 448-456.
    • (2014) Catheter Cardiovasc Interv , vol.83 , pp. 448-456
    • Reddy, S.R.1    Welch, T.R.2    Wang, J.3    Bernstein, F.4    Richardson, J.A.5    Forbess, J.M.6    Nugent, A.W.7
  • 7
    • 0043169537 scopus 로고    scopus 로고
    • The efficacy and safety of stent redilatation in congenital heart disease
    • Duke C, Rosenthal E, Qureshi SA,. The efficacy and safety of stent redilatation in congenital heart disease. Heart 2003; 89: 905-912.
    • (2003) Heart , vol.89 , pp. 905-912
    • Duke, C.1    Rosenthal, E.2    Qureshi, S.A.3
  • 8
    • 43249094707 scopus 로고    scopus 로고
    • Stent implantation is effective treatment of vascular stenosis in young infants with congenital heart disease: Acute implantation and long-term follow-up results
    • Stanfill R, Nykanen DG, Osorio S, Whalen R, Burke RP, Zahn EM,. Stent implantation is effective treatment of vascular stenosis in young infants with congenital heart disease: acute implantation and long-term follow-up results. Catheter Cardiovasc Interv 2008; 71: 831-841.
    • (2008) Catheter Cardiovasc Interv , vol.71 , pp. 831-841
    • Stanfill, R.1    Nykanen, D.G.2    Osorio, S.3    Whalen, R.4    Burke, R.P.5    Zahn, E.M.6
  • 9
    • 77953380590 scopus 로고    scopus 로고
    • Ultra-high-pressure balloon angioplasty for treatment of resistant stenoses within or adjacent to previously implanted pulmonary arterial stents
    • Maglione J, Bergersen L, Lock JE, McElhinney DB,. Ultra-high-pressure balloon angioplasty for treatment of resistant stenoses within or adjacent to previously implanted pulmonary arterial stents. Circ Cardiovasc Interv 2009; 2: 52-58.
    • (2009) Circ Cardiovasc Interv , vol.2 , pp. 52-58
    • Maglione, J.1    Bergersen, L.2    Lock, J.E.3    McElhinney, D.B.4
  • 11
    • 77955073257 scopus 로고    scopus 로고
    • Stenting in congenital heart disease: Medium- and long-term outcomes from the JPIC stent survey
    • Tomita H, Nakanishi T, Hamaoka K, Kobayashi T, Ono Y,. Stenting in congenital heart disease: medium- and long-term outcomes from the JPIC stent survey. Circ J 2010; 74: 1676-1683.
    • (2010) Circ J , vol.74 , pp. 1676-1683
    • Tomita, H.1    Nakanishi, T.2    Hamaoka, K.3    Kobayashi, T.4    Ono, Y.5
  • 12
    • 43549096661 scopus 로고    scopus 로고
    • Percutaneous stent placement in children weighing less than 10 kilograms
    • Ashwath R, Gruenstein D, Siwik E,. Percutaneous stent placement in children weighing less than 10 kilograms. Pediatr Cardiol 2008; 29: 562-567.
    • (2008) Pediatr Cardiol , vol.29 , pp. 562-567
    • Ashwath, R.1    Gruenstein, D.2    Siwik, E.3
  • 13
    • 73249115842 scopus 로고    scopus 로고
    • A premounted stent that can be implanted in infants and re-dilated to 20 mm: Introducing the Edwards Valeo Lifestent
    • Stern HJ, Baird CW,. A premounted stent that can be implanted in infants and re-dilated to 20 mm: introducing the Edwards Valeo Lifestent. Catheter Cardiovasc Interv 2009; 74: 905-912.
    • (2009) Catheter Cardiovasc Interv , vol.74 , pp. 905-912
    • Stern, H.J.1    Baird, C.W.2
  • 16
    • 79960715244 scopus 로고    scopus 로고
    • Extensive distortion and dysfunction of an Edwards Valeo Lifestent placed for stenosis of the superior vena cava
    • Aiyagari R., Extensive distortion and dysfunction of an Edwards Valeo Lifestent placed for stenosis of the superior vena cava. Catheter Cardiovasc Interv 2011; 78: 282-285.
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 282-285
    • Aiyagari, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.