메뉴 건너뛰기




Volumn 20, Issue 6, 2014, Pages

Validation of EUCAST zone diameter breakpoints against reference broth microdilution

Author keywords

Antimicrobial susceptibility testing; Broth microdilution; Disc diffusion; EUCAST clinical breakpoints; EUCAST disc diffusion method

Indexed keywords

AMPICILLIN; AZTREONAM; CEFEPIME; CEFOXITIN; CEFTAZIDIME; CEFUROXIME; CIPROFLOXACIN; CLINDAMYCIN; COTRIMOXAZOLE; ERYTHROMYCIN; FUSIDIC ACID; GENTAMICIN; IMIPENEM; LINEZOLID; MEROPENEM; MOXIFLOXACIN; NITROFURANTOIN; PENICILLIN G; PIPERACILLIN PLUS TAZOBACTAM; TEICOPLANIN; TETRACYCLINE; TIGECYCLINE; TOBRAMYCIN; TRIMETHOPRIM; VANCOMYCIN; ANTIINFECTIVE AGENT;

EID: 84904421637     PISSN: 1198743X     EISSN: 14690691     Source Type: Journal    
DOI: 10.1111/1469-0691.12414     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 33646699975 scopus 로고    scopus 로고
    • European Committee on Antimicrobial Susceptibility Testing (EUCAST) technical notes on antimicrobial susceptibility testing
    • Kahlmeter G, Brown DFJ, Goldstein FW et al. European Committee on Antimicrobial Susceptibility Testing (EUCAST) technical notes on antimicrobial susceptibility testing. Clin Microbiol Infect 2006; 12: 501-503.
    • (2006) Clin Microbiol Infect , vol.12 , pp. 501-503
    • Kahlmeter, G.1    Brown, D.F.J.2    Goldstein, F.W.3
  • 2
    • 84895921870 scopus 로고    scopus 로고
    • Development of the EUCAST disk diffusion antimicrobial susceptibility testing method and its implementation in routine microbiology laboratories
    • doi: 10.1111/1469-0691.
    • Matuschek E, Brown DFJ, Kahlmeter G. Development of the EUCAST disk diffusion antimicrobial susceptibility testing method and its implementation in routine microbiology laboratories. Clin Microbiol Infect doi: 10.1111/1469-0691.
    • Clin Microbiol Infect
    • Matuschek, E.1    Brown, D.F.J.2    Kahlmeter, G.3
  • 3
    • 84904417848 scopus 로고    scopus 로고
    • The European Committee on Antimicrobial Susceptibility Testing. Antimicrobial Susceptibility Testing. Calibration and Validation.last accessed August 26 2013.
    • The European Committee on Antimicrobial Susceptibility Testing. Antimicrobial Susceptibility Testing. Calibration and Validation. http://www.eucast.org, last accessed August 26 2013.
  • 4
    • 84904417849 scopus 로고    scopus 로고
    • ISO 20776-1. Clinical laboratory testing and in vitro diagnostic test systems-Susceptibility testing of infectious agents and evolution of performance of antimicrobial susceptibility test devices. Part 1: Reference method for testing the in vitro activity of antimicrobial agents against rapidly growing aerobic bacteria involved in infectious diseases
    • ISO 20776-1. Clinical laboratory testing and in vitro diagnostic test systems-Susceptibility testing of infectious agents and evolution of performance of antimicrobial susceptibility test devices. Part 1: Reference method for testing the in vitro activity of antimicrobial agents against rapidly growing aerobic bacteria involved in infectious diseases. 2006.
    • (2006)
  • 5
    • 84904417850 scopus 로고    scopus 로고
    • ISO 20776-2. Clinical laboratory testing and in vitro diagnostic test systems- Susceptibility testing of infectious agents and evolution of performance of antimicrobial susceptibility test devices. Part 2: Evaluation of performance of antimicrobial susceptibility test devices
    • ISO 20776-2. Clinical laboratory testing and in vitro diagnostic test systems- Susceptibility testing of infectious agents and evolution of performance of antimicrobial susceptibility test devices. Part 2: Evaluation of performance of antimicrobial susceptibility test devices. 2007.
    • (2007)
  • 6
    • 84904417851 scopus 로고    scopus 로고
    • European Committee on Antimicrobial Susceptibility Testing. Breakpoint tables for interpretation of MICs and zone diameters. Version 2.0, 2012.
    • European Committee on Antimicrobial Susceptibility Testing. Breakpoint tables for interpretation of MICs and zone diameters. Version 2.0, 2012. http://www.eucast.org
  • 7
    • 65649132752 scopus 로고    scopus 로고
    • Breakpoints for susceptibility testing should not divide wild-type distribution of important target species
    • Arendrup M, Kahlmeter G, Rodriguez-Tudela J et al. Breakpoints for susceptibility testing should not divide wild-type distribution of important target species. Antimicrob Agents Chemother 2009; 53: 1628-1629.
    • (2009) Antimicrob Agents Chemother , vol.53 , pp. 1628-1629
    • Arendrup, M.1    Kahlmeter, G.2    Rodriguez-Tudela, J.3
  • 8
    • 12444341823 scopus 로고    scopus 로고
    • Harmonization of antimicrobial breakpoints in Europe-can it be achieved?
    • Kahlmeter G, Brown DFJ. Harmonization of antimicrobial breakpoints in Europe-can it be achieved? Clin Microbiol Newsl 2004; 26: 187-192.
    • (2004) Clin Microbiol Newsl , vol.26 , pp. 187-192
    • Kahlmeter, G.1    Brown, D.F.J.2
  • 9
    • 80052266209 scopus 로고    scopus 로고
    • Setting interpretive breakpoints for antimicrobial susceptibility testing using disk diffusion
    • Kronvall G, Giske C, Kahlmeter G. Setting interpretive breakpoints for antimicrobial susceptibility testing using disk diffusion. Int J Antimicrob Agents 2011; 38: 281-290.
    • (2011) Int J Antimicrob Agents , vol.38 , pp. 281-290
    • Kronvall, G.1    Giske, C.2    Kahlmeter, G.3
  • 10
    • 84873523169 scopus 로고    scopus 로고
    • The critical influence of the intermediate category on interpretation errors in revised EUCAST and CLSI antimicrobial susceptibility testing guidelines
    • Hombach M, Böttger E, Roos M. The critical influence of the intermediate category on interpretation errors in revised EUCAST and CLSI antimicrobial susceptibility testing guidelines. Clin Microbiol Infect 2013; 2: E59-E71.
    • (2013) Clin Microbiol Infect , vol.2
    • Hombach, M.1    Böttger, E.2    Roos, M.3
  • 11
    • 43149111587 scopus 로고    scopus 로고
    • Comparison of phenotypic methods for penicillinase detection in Staphylococcus aureus
    • Kaase M, Lenga S, Friedrich S et al. Comparison of phenotypic methods for penicillinase detection in Staphylococcus aureus. Clin Microbiol Infect 2008; 14: 614-618.
    • (2008) Clin Microbiol Infect , vol.14 , pp. 614-618
    • Kaase, M.1    Lenga, S.2    Friedrich, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.