메뉴 건너뛰기




Volumn 12, Issue 8, 2014, Pages 1303-1310

Accuracy of capsule colonoscopy and computed tomographic colonography in individuals with positive results from the fecal occult blood test

Author keywords

Capsule colonoscopy; Colon cancer; Computer tomographic colonography; Early detection; Optical colonoscopy

Indexed keywords

ABDOMINAL PAIN; ADRENAL TUMOR; ADULT; AGED; ARTICLE; BLOATING; CAPSULE COLONOSCOPY; CAPSULE ENDOSCOPE; CECUM; CLINICAL ARTICLE; COLON POLYP; COLONOSCOPY; COMPUTED TOMOGRAPHIC COLONOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; HUMAN; INTERMETHOD COMPARISON; INTESTINE TRANSIT TIME; LUNG LESION; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; NEGATIVE LIKELIHOOD RATIO; OCCULT BLOOD TEST; PAIN; PATIENT ATTITUDE; PATIENT PREFERENCE; PILOT STUDY; POSITIVE LIKELIHOOD RATIO; SENSITIVITY AND SPECIFICITY; STATISTICAL PARAMETERS; TUMOR VOLUME; COLONOSCOPE; DIAGNOSTIC IMAGING; DIAGNOSTIC PROCEDURE; IMMUNOCHEMISTRY; OPTICAL COLONOSCOPY; POLYP; COLON; COLONIC NEOPLASMS; EVALUATION STUDY; ISRAEL; MIDDLE AGED; OCCULT BLOOD; PATHOLOGY; POLYPS; PROCEDURES;

EID: 84904394106     PISSN: 15423565     EISSN: 15427714     Source Type: Journal    
DOI: 10.1016/j.cgh.2013.12.027     Document Type: Article
Times cited : (71)

References (15)
  • 1
    • 79551578688 scopus 로고    scopus 로고
    • Protection from colorectal cancer after colonoscopy: a population-based, case-control study
    • Brenner H., Chang-Claude J., Seiler C.M., et al. Protection from colorectal cancer after colonoscopy: a population-based, case-control study. Ann Intern Med 2011, 154:22-30.
    • (2011) Ann Intern Med , vol.154 , pp. 22-30
    • Brenner, H.1    Chang-Claude, J.2    Seiler, C.M.3
  • 2
    • 0037354345 scopus 로고    scopus 로고
    • Epidemiologic and health economic significance of colorectal cancers in Germany
    • 276-277
    • Knopnadel J., Altenhofen L., Brenner G. Epidemiologic and health economic significance of colorectal cancers in Germany. Internist (Berl) 2003, 44:268-274. 276-277.
    • (2003) Internist (Berl) , vol.44 , pp. 268-274
    • Knopnadel, J.1    Altenhofen, L.2    Brenner, G.3
  • 3
    • 84861639726 scopus 로고    scopus 로고
    • Efficacy of a nationwide screening colonoscopy program for colorectal cancer
    • Pox C.P., Altenhofen L., Brenner H., et al. Efficacy of a nationwide screening colonoscopy program for colorectal cancer. Gastroenterology 2012, 142:1460-1467.
    • (2012) Gastroenterology , vol.142 , pp. 1460-1467
    • Pox, C.P.1    Altenhofen, L.2    Brenner, H.3
  • 4
    • 84875843412 scopus 로고    scopus 로고
    • Computed tomographic colonography versus colonoscopy for investigation ofpatients with symptoms suggestive of colorectal cancer (SIGGAR): a multicentre randomised trial
    • Atkin W., Dadswell E., Wooldrage K., et al. Computed tomographic colonography versus colonoscopy for investigation ofpatients with symptoms suggestive of colorectal cancer (SIGGAR): a multicentre randomised trial. Lancet 2013, 381:1194-1202.
    • (2013) Lancet , vol.381 , pp. 1194-1202
    • Atkin, W.1    Dadswell, E.2    Wooldrage, K.3
  • 5
    • 65449168056 scopus 로고    scopus 로고
    • Accuracy of computed tomographic colonography for the detection of polyps and colorectal tumors: a systematic review and meta-analysis
    • Chaparro M., Gisbert J.P., Del Campo L., et al. Accuracy of computed tomographic colonography for the detection of polyps and colorectal tumors: a systematic review and meta-analysis. Digestion 2009, 80:1-17.
    • (2009) Digestion , vol.80 , pp. 1-17
    • Chaparro, M.1    Gisbert, J.P.2    Del Campo, L.3
  • 6
    • 84862501841 scopus 로고    scopus 로고
    • Patient acceptability and psychologic consequences of CT colonography compared with those of colonoscopy: results from a multicenter randomized controlled trial of symptomatic patients
    • von Wagner C., Ghanouni A., Halligan S., et al. Patient acceptability and psychologic consequences of CT colonography compared with those of colonoscopy: results from a multicenter randomized controlled trial of symptomatic patients. Radiology 2012, 263:723-731.
    • (2012) Radiology , vol.263 , pp. 723-731
    • von Wagner, C.1    Ghanouni, A.2    Halligan, S.3
  • 7
    • 71549122331 scopus 로고    scopus 로고
    • Prospective multicenter performance evaluation of the second-generation colon capsulecompared with colonoscopy
    • Eliakim R., Yassin K., Niv Y., et al. Prospective multicenter performance evaluation of the second-generation colon capsulecompared with colonoscopy. Endoscopy 2009, 41:1026-1031.
    • (2009) Endoscopy , vol.41 , pp. 1026-1031
    • Eliakim, R.1    Yassin, K.2    Niv, Y.3
  • 8
    • 80052244323 scopus 로고    scopus 로고
    • Second-generation colon capsule endoscopy compared with colonoscopy
    • Spada C., Hassan C., Munoz-Navas M., et al. Second-generation colon capsule endoscopy compared with colonoscopy. Gastrointest Endosc 2011, 74:581-589.
    • (2011) Gastrointest Endosc , vol.74 , pp. 581-589
    • Spada, C.1    Hassan, C.2    Munoz-Navas, M.3
  • 9
    • 84865504603 scopus 로고    scopus 로고
    • Asurvey of potential adherence to capsule colonoscopy in patients who have accepted or declined conventional colonoscopy
    • Rex D.K., Lieberman D.A. Asurvey of potential adherence to capsule colonoscopy in patients who have accepted or declined conventional colonoscopy. JClin Gastroenterol 2012, 46:691-695.
    • (2012) JClin Gastroenterol , vol.46 , pp. 691-695
    • Rex, D.K.1    Lieberman, D.A.2
  • 10
    • 79551488965 scopus 로고    scopus 로고
    • Agrading scale to evaluate colon cleansing for the PillCam COLON capsule: a reliability study
    • Leighton J.A., Rex D.K. Agrading scale to evaluate colon cleansing for the PillCam COLON capsule: a reliability study. Endoscopy 2011, 43:123-127.
    • (2011) Endoscopy , vol.43 , pp. 123-127
    • Leighton, J.A.1    Rex, D.K.2
  • 11
    • 0033850298 scopus 로고    scopus 로고
    • Anovel tableted purgative for colonoscopic preparation: efficacy and safety comparisons with Colyte and Fleet phosphosoda
    • Aronchick C., Lipshutz W., Wright S., et al. Anovel tableted purgative for colonoscopic preparation: efficacy and safety comparisons with Colyte and Fleet phosphosoda. Gastrointest Endosc 2000, 52:346-352.
    • (2000) Gastrointest Endosc , vol.52 , pp. 346-352
    • Aronchick, C.1    Lipshutz, W.2    Wright, S.3
  • 12
    • 84865860727 scopus 로고    scopus 로고
    • Population-based screening for colorectal cancer using an immunochemical faecal occult blood test: a comparison of two invitation strategies
    • van Roosbroeck S., Hoeck S., Van Hal G. Population-based screening for colorectal cancer using an immunochemical faecal occult blood test: a comparison of two invitation strategies. Cancer Epidemiol 2012, 36:317-324.
    • (2012) Cancer Epidemiol , vol.36 , pp. 317-324
    • van Roosbroeck, S.1    Hoeck, S.2    Van Hal, G.3
  • 13
    • 19244365862 scopus 로고    scopus 로고
    • Location of adenomas missed by optical colonoscopy
    • Pickhardt P.J., Nugent P.A., Mysliwiec P.A., et al. Location of adenomas missed by optical colonoscopy. Ann Intern Med 2004, 141:352-359.
    • (2004) Ann Intern Med , vol.141 , pp. 352-359
    • Pickhardt, P.J.1    Nugent, P.A.2    Mysliwiec, P.A.3
  • 14
    • 34948891641 scopus 로고    scopus 로고
    • CT colonography versus colonoscopy for the detection of advanced neoplasia
    • Kim D.H., Pickhardt P.J., Taylor A.J., et al. CT colonography versus colonoscopy for the detection of advanced neoplasia. NEngl J Med 2007, 357:1403-1412.
    • (2007) NEngl J Med , vol.357 , pp. 1403-1412
    • Kim, D.H.1    Pickhardt, P.J.2    Taylor, A.J.3
  • 15
    • 84882995493 scopus 로고    scopus 로고
    • Advancing in CT colonography for colorectal cancer screening and diagnosis
    • Yee J., Weinstein S., Morgan T., et al. Advancing in CT colonography for colorectal cancer screening and diagnosis. JCancer 2013, 4:200-209.
    • (2013) JCancer , vol.4 , pp. 200-209
    • Yee, J.1    Weinstein, S.2    Morgan, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.