-
1
-
-
0003595573
-
-
Prentice Hall Englewood Cliffs, NJ
-
G.S. Kino Acoustic waves 1987 Prentice Hall Englewood Cliffs, NJ
-
(1987)
Acoustic Waves
-
-
Kino, G.S.1
-
4
-
-
60349132113
-
Alumina/epoxy nanocomposite matching layers for high-frequency ultrasound transducer application
-
Q.F. Zhou, J.H. Cha, Y. Huang, R. Zhang, W. Cao, and K.K. Shung Alumina/epoxy nanocomposite matching layers for high-frequency ultrasound transducer application IEEE Trans Ultrason Ferroelect Freq Contr 56 1 2009 213 219
-
(2009)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.56
, Issue.1
, pp. 213-219
-
-
Zhou, Q.F.1
Cha, J.H.2
Huang, Y.3
Zhang, R.4
Cao, W.5
Shung, K.K.6
-
5
-
-
77952798408
-
Nanocomposite materials for high frequency ultrasound matching layers
-
F. Tiefensee, and C. Becker Willinger Nanocomposite materials for high frequency ultrasound matching layers Proc IEEE Ultrason Symp 2009 1719 1721
-
(2009)
Proc IEEE Ultrason Symp
, pp. 1719-1721
-
-
Tiefensee, F.1
Becker Willinger, C.2
-
6
-
-
0032593551
-
Passive materials for high frequency ultrasonic transducers
-
H. Wang, T.A. Ritter, W. Cao, and K.K. Shung Passive materials for high frequency ultrasonic transducers Proc SPIE Med Imag, Ultrason Trans Imag 3664 1999 35 42
-
(1999)
Proc SPIE Med Imag, Ultrason Trans Imag
, vol.3664
, pp. 35-42
-
-
Wang, H.1
Ritter, T.A.2
Cao, W.3
Shung, K.K.4
-
8
-
-
0442326648
-
Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications
-
J.M. Cannata, T.A. Ritter, W.H. Chen, R.H. Silverman, and K.K. Shung Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications IEEE Trans Ultrason Ferroelect Freq Contr 50 11 2003 1548 1557
-
(2003)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.50
, Issue.11
, pp. 1548-1557
-
-
Cannata, J.M.1
Ritter, T.A.2
Chen, W.H.3
Silverman, R.H.4
Shung, K.K.5
-
9
-
-
0034745861
-
High frequency properties of passive materials for ultrasonic transducers
-
DOI 10.1109/58.895911
-
H.F. Wang, T.A. Ritter, W.W. Cao, and K.K. Shung High frequency properties of passive materials for ultrasonic transducers IEEE Trans Ultrason Ferroelect Freq Contr 48 1 2001 78 84 (Pubitemid 32191183)
-
(2001)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.48
, Issue.1
, pp. 78-84
-
-
Wang, H.1
Ritter, T.2
Cao, W.3
Shung, K.K.4
-
11
-
-
0014796286
-
New equivalent circuits for elementary piezoelectric transducers
-
R. Krimholtz, D. Leedom, and G. Matthaei New equivalent circuits for elementary piezoelectric transducers Electron Lett 6 1970 398 399
-
(1970)
Electron Lett
, vol.6
, pp. 398-399
-
-
Krimholtz, R.1
Leedom, D.2
Matthaei, G.3
-
12
-
-
33750150943
-
Experimental technique for characterizing arbitrary aspect ratio piezoelectric resonators
-
M. Kim, J. Kim, and W.W. Cao Experimental technique for characterizing arbitrary aspect ratio piezoelectric resonators Appl Phys Lett 89 2006 162910
-
(2006)
Appl Phys Lett
, vol.89
, pp. 162910
-
-
Kim, M.1
Kim, J.2
Cao, W.W.3
-
13
-
-
0026062827
-
Modeling 1-3 composite piezoelectrics-thickness mode oscillations
-
W.A. Smith, and B.A. Auld Modeling 1-3 composite piezoelectrics-thickness mode oscillations IEEE Trans Ultrason Ferroelect Freq Contr 38 1 1991 40 47
-
(1991)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.38
, Issue.1
, pp. 40-47
-
-
Smith, W.A.1
Auld, B.A.2
-
15
-
-
0034745874
-
Interdigital pair bonding for high frequency (20-50 MHz) ultrasonic composite transducers
-
DOI 10.1109/58.896143
-
R.B. Liu, K.A. Harasiewicz, and F.S. Foster Interdigital pair bonding for high frequency (20-50 MHz) ultrasonic composite transducers IEEE Trans Ultrason Ferroelect Freq Contr 48 1 2001 299 306 (Pubitemid 32191206)
-
(2001)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.48
, Issue.1
, pp. 299-306
-
-
Liu, R.1
Harasiewicz, K.A.2
Stuart Foster, F.3
-
16
-
-
0032679818
-
Ferroelectric ceramics: History and technology
-
G.H. Haertling Ferroelectric ceramics: history and technology J Am Ceram Soc 82 4 1999 797 818
-
(1999)
J Am Ceram Soc
, vol.82
, Issue.4
, pp. 797-818
-
-
Haertling, G.H.1
-
17
-
-
0001198020
-
Properties of piezoelectric ceramics in the solid-solution series lead titanate-lead zirconate-lead oxide: Tin oxide and leadtitanate-lead hafnate
-
B. Jaffe, R.S. Roth, and S. Marzullo Properties of piezoelectric ceramics in the solid-solution series lead titanate-lead zirconate-lead oxide: tin oxide and leadtitanate-lead hafnate J Res Natl Bur Standard 55 1955 239 254
-
(1955)
J Res Natl Bur Standard
, vol.55
, pp. 239-254
-
-
Jaffe, B.1
Roth, R.S.2
Marzullo, S.3
-
18
-
-
0001562895
-
Dielectric polarization and losses of some complex compounds
-
G.A. Smolenskii, and A.I. Agranovskaya Dielectric polarization and losses of some complex compounds Sov Phys Tech Phys 3 1958 1380 1382
-
(1958)
Sov Phys Tech Phys
, vol.3
, pp. 1380-1382
-
-
Smolenskii, G.A.1
Agranovskaya, A.I.2
-
19
-
-
84915043629
-
Piezoelectric properties of polycrystalline lead titanate zirconate compositions
-
D.A. Berlincourt, C. Cmolik, and H. Jaffe Piezoelectric properties of polycrystalline lead titanate zirconate compositions Proc IRA 48 1960 220 229
-
(1960)
Proc IRA
, vol.48
, pp. 220-229
-
-
Berlincourt, D.A.1
Cmolik, C.2
Jaffe, H.3
-
20
-
-
0002458149
-
Preparation of single crystals of complex perovskite ferroelectric and semiconducting compounds
-
F. Galasso, and W. Darby Preparation of single crystals of complex perovskite ferroelectric and semiconducting compounds Inorg Chem 4 1 1965 71 73
-
(1965)
Inorg Chem
, vol.4
, Issue.1
, pp. 71-73
-
-
Galasso, F.1
Darby, W.2
-
21
-
-
84963175268
-
Relaxor ferroelectrics
-
L.E. Cross Relaxor ferroelectrics Ferroelectrics 76 1987 241 267
-
(1987)
Ferroelectrics
, vol.76
, pp. 241-267
-
-
Cross, L.E.1
-
22
-
-
0030196258
-
The role of processing variables in the flux growth of lead zinc niobate-lead titanate relaxor ferroelectric single crystals
-
M.L. Mulvihill, S.E. Park, G. Risch, Z. Li, K. Uchino, and T.R. Shrout The role of processing variables in the flux growth of lead zinc niobate-lead titanaterelaxor ferroelectric single crystals Jpn J Appl Phys 35 1996 3984 3990 (Pubitemid 126530516)
-
(1996)
Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers
, vol.35
, Issue.7
, pp. 3984-3990
-
-
Mulvihill, M.L.1
Park, S.E.2
Risch, G.3
Li, Z.4
Uchino, K.5
Shrout, T.R.6
-
24
-
-
79551663666
-
Enhanced ME effect in a stress-biased PMN-PT single crystal/Terfenol-D alloy magnetoelectric sensor
-
K.H. Lam, C.Y. Lo, J.Y. Dai, H.L.W. Chan, and H.S. Luo Enhanced ME effect in a stress-biased PMN-PT single crystal/Terfenol-D alloy magnetoelectric sensor J Appl Phys 109 2 2011 024505
-
(2011)
J Appl Phys
, vol.109
, Issue.2
, pp. 024505
-
-
Lam, K.H.1
Lo, C.Y.2
Dai, J.Y.3
Chan, H.L.W.4
Luo, H.S.5
-
25
-
-
79955923568
-
Pyroelectric performances of relaxor-based ferroelectric single crystals and related infrared detectors
-
X.Y. Zhao, X. Wu, L.H. Liu, H.S. Luo, N. Neumann, and P. Yu Pyroelectric performances of relaxor-based ferroelectric single crystals and related infrared detectors Phys Status Solidi A Appl Mater 208 5 2011 1061 1067
-
(2011)
Phys Status Solidi A Appl Mater
, vol.208
, Issue.5
, pp. 1061-1067
-
-
Zhao, X.Y.1
Wu, X.2
Liu, L.H.3
Luo, H.S.4
Neumann, N.5
Yu, P.6
-
26
-
-
0343403763
-
Relaxor based ferroelectric single crystals for electro-mechanical actuators
-
S.E. Park, and T.R. Shrout Relaxor based ferroelectric single crystals for electro-mechanical actuators Mater Res Innovations 1 1 1997 20 25
-
(1997)
Mater Res Innovations
, vol.1
, Issue.1
, pp. 20-25
-
-
Park, S.E.1
Shrout, T.R.2
-
27
-
-
0036544033
-
A high-frequency, high-stiffness piezoelectric actuator for microhydraulic applications
-
DOI 10.1016/S0924-4247(01)00841-X, PII S092442470100841X
-
D.C. Roberts, H.Q. Li, J.L. Steyn, K.T. Turner, R. Mlcak, and L. Saggere et al. A high-frequency, high-stiffness piezoelectric actuator for microhydraulic applications Sensor Actuator A Phys 97 8 2002 620 631 (Pubitemid 34758774)
-
(2002)
Sensors and Actuators, A: Physical
, vol.97-98
, pp. 620-631
-
-
Roberts, D.C.1
Li, H.2
Steyn J.Lodewyk3
Turner, K.T.4
Mlcak, R.5
Saggere, L.6
Spearing S.Mark7
Schmidt, M.A.8
Hagood, N.W.9
-
28
-
-
21744452890
-
Piezoelectrically actuated ejector using PMN-PT single crystal
-
DOI 10.1016/j.sna.2005.01.003, PII S0924424705000087
-
K.H. Lam, H.L.W. Chan, H.S. Luo, Q.R. Yin, and Z.W. Yin Piezoelectrically actuated ejector using PMN-PT single crystal Sensor Actuator A Phys 121 2005 197 202 (Pubitemid 40940800)
-
(2005)
Sensors and Actuators, A: Physical
, vol.121
, Issue.1
, pp. 197-202
-
-
Lam, K.H.1
Chan, H.L.W.2
Luo, H.S.3
Yin, Q.R.4
Yin, Z.W.5
-
30
-
-
0034226634
-
Single crystal PZN/PT-polymer composites for ultrasound transducer applications
-
T. Ritter, X.C. Geng, K.K. Shung, P.D. Lopath, S.E. Park, and T.R. Shrout Single crystal PZN/PT-polymer composites for ultrasound transducer applications IEEE Trans Ultrason Ferroelect Freq Contr 47 4 2000 792 800
-
(2000)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.47
, Issue.4
, pp. 792-800
-
-
Ritter, T.1
Geng, X.C.2
Shung, K.K.3
Lopath, P.D.4
Park, S.E.5
Shrout, T.R.6
-
31
-
-
33645688116
-
Single crystal PMN-PT/epoxy 1-3 composite for energy-harvesting application
-
K.L. Ren, Y.M. Liu, X.C. Geng, H.F. Hofmann, and Q.M.M. Zhang Single crystal PMN-PT/epoxy 1-3 composite for energy-harvesting application IEEE Trans Ultrason Ferroelect Freq Contr 53 3 2006 631 638
-
(2006)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.53
, Issue.3
, pp. 631-638
-
-
Ren, K.L.1
Liu, Y.M.2
Geng, X.C.3
Hofmann, H.F.4
Zhang, Q.M.M.5
-
32
-
-
34347248774
-
Mechanical and thermal transitions in morphotropic PZN-PT and PMN-PT single crystals and their implication for sound projectors
-
DOI 10.1109/TUFFC.2007.362
-
A. Amin, E. McLaughlin, H. Robinson, and L. Ewart Mechanical and thermal transitions in morphotropic PZN-PT and PMN-PT single crystals and their implication for sound projectors IEEE Trans Ultrason Ferroelect Freq Contr 54 6 2007 1090 1095 (Pubitemid 47000319)
-
(2007)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.54
, Issue.6
, pp. 1090-1095
-
-
Amin, A.1
McLaughlin, E.2
Robinson, H.3
Ewart, L.4
-
33
-
-
0001724442
-
Broadband monolithic acousto-optic tunable filter
-
H. Gnewuch, N.K. Zayer, C.N. Pannell, G.W. Ross, and P.G.R. Smith Broadband monolithic acousto-optic tunable filter Opt Lett 25 5 2000 305 307
-
(2000)
Opt Lett
, vol.25
, Issue.5
, pp. 305-307
-
-
Gnewuch, H.1
Zayer, N.K.2
Pannell, C.N.3
Ross, G.W.4
Smith, P.G.R.5
-
34
-
-
0036462528
-
Design, fabrication, and evaluation of high frequency, single-element transducers incorporating different materials
-
DOI 10.1109/58.985701
-
K.A. Snook, J.Z. Zhao, C.H.F. Alves, J.M. Cannata, W.H. Chen, and J.J. Meyer et al. Design, fabrication, and evaluation of high frequency, single-element transducers incorporating different materials IEEE Trans Ultrason Ferroelect Freq Contr 49 2 2002 169 176 (Pubitemid 34278282)
-
(2002)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.49
, Issue.2
, pp. 169-176
-
-
Snook, K.A.1
Zhao, J.-Z.2
Alves, C.H.F.3
Cannata, J.M.4
Chen, W.-H.5
Meyer Jr., R.J.6
Ritter, T.A.7
Shung, K.K.8
-
35
-
-
70350704576
-
Photonic guiding structures in lithium niobate crystals produced by energetic ion beams
-
F. Chen Photonic guiding structures in lithium niobate crystals produced by energetic ion beams J Appl Phys 106 8 2009 081101
-
(2009)
J Appl Phys
, vol.106
, Issue.8
, pp. 081101
-
-
Chen, F.1
-
38
-
-
0026202356
-
Compositional uniformity in growth and poling of large-diameter lithium niobate crystals
-
DOI 10.1016/0022-0248(91)90009-T
-
P.F. Bordui, R.G. Norwood, C.D. Bird, and G.D. Calvert Compositional uniformity in growth and poling of large-diameter lithium niobate crystals J Cryst Growth 113 1991 61 68 (Pubitemid 21711715)
-
(1991)
Journal of Crystal Growth
, vol.113
, Issue.1-2
, pp. 61-68
-
-
Bordui, P.F.1
Norwood, R.G.2
Bird, C.D.3
Calvert, G.D.4
-
40
-
-
33749492698
-
Preparation and characterization of off-congruent lithium niobate crystals
-
P.F. Bordui, R.G. Norwood, D.H. Jundt, and M.M. Fejer Preparation and characterization of off-congruent lithium niobate crystals J Appl Phys 71 1992 875 879
-
(1992)
J Appl Phys
, vol.71
, pp. 875-879
-
-
Bordui, P.F.1
Norwood, R.G.2
Jundt, D.H.3
Fejer, M.M.4
-
42
-
-
0001368929
-
Piezoelectric and elastic properties of lithium niobate single crystals
-
T. Yamada, N. Niizeki, and H. Toyoda Piezoelectric and elastic properties of lithium niobate single crystals Jpn J Appl Phys 6 2 1967 151 155
-
(1967)
Jpn J Appl Phys
, vol.6
, Issue.2
, pp. 151-155
-
-
Yamada, T.1
Niizeki, N.2
Toyoda, H.3
-
43
-
-
13844267535
-
3 single crystal
-
DOI 10.1109/TUFFC.2005.1397357
-
3 single crystal IEEE Trans Ultrason Ferroelect Freq Contr 52 1 2005 127 133 (Pubitemid 40245482)
-
(2005)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.52
, Issue.1
, pp. 127-133
-
-
Zhou, Q.1
Cannata, J.M.2
Guo, H.3
Huang, C.4
Marmarelis, V.Z.5
Shung, K.K.6
-
44
-
-
0036463010
-
High performance single crystal piezoelectrics: Applications and issues
-
S.E. Park, and W. Hackenberger High performance single crystal piezoelectrics: applications and issues Curr Opin Solid State Mater Sci 6 2002 11 18
-
(2002)
Curr Opin Solid State Mater Sci
, vol.6
, pp. 11-18
-
-
Park, S.E.1
Hackenberger, W.2
-
45
-
-
0028510881
-
Large electromechanical coupling factors in perovskite binary material system
-
Y. Yamashita Large electromechanical coupling factors in perovskite binary material system Jpn J Appl Phys 33 1994 5328 5331
-
(1994)
Jpn J Appl Phys
, vol.33
, pp. 5328-5331
-
-
Yamashita, Y.1
-
46
-
-
84860427908
-
High performance ferroelectric relaxor-PT single crystals: Status and perspective
-
S.J. Zhang, and F. Li High performance ferroelectric relaxor-PT single crystals: status and perspective J Appl Phys 111 2012 031301
-
(2012)
J Appl Phys
, vol.111
, pp. 031301
-
-
Zhang, S.J.1
Li, F.2
-
49
-
-
0031211577
-
Ultrahigh strain and piezoelectric behavior in relaxor based ferroelectric single crystals
-
S.E. Park, and T.R. Shrout Ultrahigh strain and piezoelectric behavior in relaxor based ferroelectric single crystals J Appl Phys 82 1997 1804 1811 (Pubitemid 127590063)
-
(1997)
Journal of Applied Physics
, vol.82
, Issue.4
, pp. 1804-1811
-
-
Park, S.-E.1
Shrout, T.R.2
-
54
-
-
0000687850
-
3 system grown by the vertical Bridgeman method and its characterization
-
3 system grown by the vertical Bridgeman method and its characterization Jpn J Appl Phys 1 37 1998 3382 3385
-
(1998)
Jpn J Appl Phys
, vol.1
, Issue.37
, pp. 3382-3385
-
-
Shimanuki, S.1
Saitoh, S.2
Yamashita, Y.3
-
56
-
-
0032403535
-
Characterization of piezoelectric materials using ultrasonic and resonant techniques
-
S. Zhu, B. Jiang, and W. Cao Characterization of piezoelectric materials using ultrasonic and resonant techniques Proc SPIE 3341 1998 154
-
(1998)
Proc SPIE
, vol.3341
, pp. 154
-
-
Zhu, S.1
Jiang, B.2
Cao, W.3
-
57
-
-
0141938525
-
Single crystal PMN-0.33PT/epoxy 1-3 composites for ultrasonic transducer applications
-
K.C. Cheng, H.L.W. Chan, C.L. Choy, Q.R. Yin, H.S. Luo, and Z.W. Yin Single crystal PMN-0.33PT/epoxy 1-3 composites for ultrasonic transducer applications IEEE Trans Ultrason Ferroelect Freq Contr 50 9 2003 1177 1183
-
(2003)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.50
, Issue.9
, pp. 1177-1183
-
-
Cheng, K.C.1
Chan, H.L.W.2
Choy, C.L.3
Yin, Q.R.4
Luo, H.S.5
Yin, Z.W.6
-
58
-
-
2942748658
-
Ferroelectric lead magnesium niobate-lead titanate single crystals for ultrasonic hydrophone applications
-
S.T. Lau, K.H. Lam, H.L.W. Chan, C.L. Choy, H.S. Luo, and Q.R. Yin et al. Ferroelectric lead magnesium niobate-lead titanate single crystals for ultrasonic hydrophone applications Mater Sci Eng B 111 1 2003 25 30
-
(2003)
Mater Sci Eng B
, vol.111
, Issue.1
, pp. 25-30
-
-
Lau, S.T.1
Lam, K.H.2
Chan, H.L.W.3
Choy, C.L.4
Luo, H.S.5
Yin, Q.R.6
-
59
-
-
33750712084
-
PMN-PT single-crystal transducer for non-destructive evaluation
-
DOI 10.1016/j.sna.2006.02.024, PII S092442470600152X
-
G. Edwards, H.L.W. Chan, A. Batten, K.H. Lam, H.S. Luo, and D.A. Scott PMN-PT single-crystal transducer for non-destructive evaluation Sensor Actuator A Phys 132 2 2006 434 440 (Pubitemid 44708668)
-
(2006)
Sensors and Actuators, A: Physical
, vol.132
, Issue.2
, pp. 434-440
-
-
Edwards, G.1
Chan, H.L.W.2
Batten, A.3
Lam, K.H.4
Luo, H.S.5
Scott, D.A.6
-
60
-
-
80054682151
-
PMN-PT single crystal focusing transducer fabricated using a mechanical dimpling technique
-
K.H. Lam, Y. Chen, K.F. Cheung, and JY. Dai PMN-PT single crystal focusing transducer fabricated using a mechanical dimpling technique Ultrasonics 52 1 2011 20 24
-
(2011)
Ultrasonics
, vol.52
, Issue.1
, pp. 20-24
-
-
Lam, K.H.1
Chen, Y.2
Cheung, K.F.3
Dai, J.Y.4
-
61
-
-
67649371687
-
60 MHz PMN-PT based 1-3 composite transducer for IVUS imaging
-
J. Yuan, S. Rhee, and X.N. Jiang 60 MHz PMN-PT based 1-3 composite transducer for IVUS imaging Proc IEEE Ultra Symp 2008 682 685
-
(2008)
Proc IEEE Ultra Symp
, pp. 682-685
-
-
Yuan, J.1
Rhee, S.2
Jiang, X.N.3
-
62
-
-
67649362288
-
Novel biomedical imaging that combines intravascular ultrasound (IVUS) and optical coherence tomography (OCT)
-
H.C. Yang, J.C. Yin, C.H. Hu, Q.F. Zhou, J. Cannata, and Z.P. Chen et al. Novel biomedical imaging that combines intravascular ultrasound (IVUS) and optical coherence tomography (OCT) Proc IEEE Ultra Symp 2008 1769 1772
-
(2008)
Proc IEEE Ultra Symp
, pp. 1769-1772
-
-
Yang, H.C.1
Yin, J.C.2
Hu, C.H.3
Zhou, Q.F.4
Cannata, J.5
Chen, Z.P.6
-
63
-
-
0033326132
-
Growth and characterization of relaxor ferroelectric PMNT single crystal
-
H. Luo, G. Xu, P. Wang, and Z. Yin Growth and characterization of relaxor ferroelectric PMNT single crystal Ferroelectrics 231 1999 97 102
-
(1999)
Ferroelectrics
, vol.231
, pp. 97-102
-
-
Luo, H.1
Xu, G.2
Wang, P.3
Yin, Z.4
-
65
-
-
0036614471
-
3 piezoelectric single crystals
-
3 piezoelectric single crystals Jpn J Appl Phys 41 2002 3808 3811 (Pubitemid 34962214)
-
(2002)
Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers
, vol.41
, Issue.6 A
, pp. 3808-3811
-
-
Hosono, Y.1
Harada, K.2
Kobayashi, T.3
Itsumi, K.4
Izumi, M.5
Yamashita, Y.6
Ichinose, N.7
-
67
-
-
0036669965
-
3 single crystal grown by the modified Bridgman technique
-
DOI 10.1016/S0038-1098(02)00311-3, PII S0038109802003113
-
3 single crystal grown by the modified Bridgeman technique Solid State Commun 123 9 2002 417 420 (Pubitemid 34992056)
-
(2002)
Solid State Communications
, vol.123
, Issue.9
, pp. 417-420
-
-
Guo, Y.1
Luo, H.2
He, T.3
Yin, Z.4
-
68
-
-
33846440070
-
3 crystals prepared by the vertical Bridgeman technique
-
3 crystals prepared by the vertical Bridgeman technique Appl Phys Lett 90 2007 032901
-
(2007)
Appl Phys Lett
, vol.90
, pp. 032901
-
-
Xu, G.1
Chen, K.2
Yang, D.3
Li, J.4
-
69
-
-
79952737670
-
Recent development on high Curie temperature PIN-PMN-PT ferroelectric crystals
-
S. Zhang, F. Li, N.P. Sherlock, J. Luo, H.J. Lee, and R. Xia et al. Recent development on high Curie temperature PIN-PMN-PT ferroelectric crystals J Cryst Growth 318 2011 846 850
-
(2011)
J Cryst Growth
, vol.318
, pp. 846-850
-
-
Zhang, S.1
Li, F.2
Sherlock, N.P.3
Luo, J.4
Lee, H.J.5
Xia, R.6
-
70
-
-
36549063679
-
Improved stability of piezoelectric crystals grown in the lead indium niobate-lead magnesium niobate-lead titanate system
-
J. Tian, P. Han, X. Huang, and H. Pan Improved stability of piezoelectric crystals grown in the lead indium niobate-lead magnesium niobate-lead titanate system Appl Phys Lett 91 2007 222903
-
(2007)
Appl Phys Lett
, vol.91
, pp. 222903
-
-
Tian, J.1
Han, P.2
Huang, X.3
Pan, H.4
-
73
-
-
67649362295
-
PIN-PMN-PT single crystal high frequency ultrasound transducers for medical applications
-
Q.F. Zhou, B.P. Zhu, D.W. Wu, C.H. Hu, J.M. Cannata, and J. Tian et al. PIN-PMN-PT single crystal high frequency ultrasound transducers for medical applications Proc IEEE Ultra Symp 2008 1433 1436
-
(2008)
Proc IEEE Ultra Symp
, pp. 1433-1436
-
-
Zhou, Q.F.1
Zhu, B.P.2
Wu, D.W.3
Hu, C.H.4
Cannata, J.M.5
Tian, J.6
-
74
-
-
73649106944
-
Design and fabrication of PIN-PMN-PT single-crystal high-frequency ultrasound transducers
-
P. Sun, Q.F. Zhou, B.P. Zhu, D.W. Wu, C.L. Hu, and J.M. Cannata et al. Design and fabrication of PIN-PMN-PT single-crystal high-frequency ultrasound transducers IEEE Trans Ultrason Ferroelect Freq Contr 56 12 2009 2760 2763
-
(2009)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.56
, Issue.12
, pp. 2760-2763
-
-
Sun, P.1
Zhou, Q.F.2
Zhu, B.P.3
Wu, D.W.4
Hu, C.L.5
Cannata, J.M.6
-
75
-
-
77954202126
-
3 crystals and composites for high frequency ultrasound
-
3 crystals and composites for high frequency ultrasound J Appl Phys 107 2010 124107
-
(2010)
J Appl Phys
, vol.107
, pp. 124107
-
-
Lee, H.J.1
Zhang, S.J.2
Shrout, T.R.3
-
76
-
-
84865273984
-
High-frequency PIN-PMN-PT single crystal ultrasonic transducer for imaging applications
-
Y. Chen, K.H. Lam, D. Zhou, W.F. Cheng, J.Y. Dai, and H.S. Luo et al. High-frequency PIN-PMN-PT single crystal ultrasonic transducer for imaging applications Appl Phys A Mater 108 2012 987 991
-
(2012)
Appl Phys A Mater
, vol.108
, pp. 987-991
-
-
Chen, Y.1
Lam, K.H.2
Zhou, D.3
Cheng, W.F.4
Dai, J.Y.5
Luo, H.S.6
-
78
-
-
84903966091
-
-
H.C. Materials Corporation
-
H.C. Materials Corporation. < www.hcmat.com >.
-
-
-
-
79
-
-
84870251029
-
High frequency PMN-PT single crystal focusing transducer fabricated by a mechanical dimpling technique
-
Y. Chen, K.H. Lam, D. Zhou, W.F. Cheng, J.Y. Dai, and H.S. Luo et al. High frequency PMN-PT single crystal focusing transducer fabricated by a mechanical dimpling technique Ultrasonics 53 2 2013 345 349
-
(2013)
Ultrasonics
, vol.53
, Issue.2
, pp. 345-349
-
-
Chen, Y.1
Lam, K.H.2
Zhou, D.3
Cheng, W.F.4
Dai, J.Y.5
Luo, H.S.6
-
80
-
-
84869447073
-
An open system for intravascular ultrasound imaging
-
W. Qiu, Y. Chen, X. Li, Y. Yu, W.F. Cheng, and F.K. Tsang et al. An open system for intravascular ultrasound imaging IEEE Trans Ultrason Ferroelectr Freq Contr 59 10 2012 2201 2209
-
(2012)
IEEE Trans Ultrason Ferroelectr Freq Contr
, vol.59
, Issue.10
, pp. 2201-2209
-
-
Qiu, W.1
Chen, Y.2
Li, X.3
Yu, Y.4
Cheng, W.F.5
Tsang, F.K.6
-
81
-
-
33947666048
-
PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application
-
Q. Zhou, X. Xu, E.J. Gottlieb, L. Sun, J.M. Cannata, and H. Ameri et al. PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application IEEE Trans Ultrason Ferroelect Freq Contr 54 3 2007 668 675
-
(2007)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.54
, Issue.3
, pp. 668-675
-
-
Zhou, Q.1
Xu, X.2
Gottlieb, E.J.3
Sun, L.4
Cannata, J.M.5
Ameri, H.6
-
83
-
-
23844447394
-
Piezoelectric composites for sensor and actuator applications
-
DOI 10.1109/TUFFC.2005.1503962
-
E.K. Akdogan, M. Allahverdi, and A. Safari Piezoelectric composites for sensor and actuator applications IEEE Trans Ultrason Ferroelect Freq Contr 52 5 2005 746 775 (Pubitemid 41161915)
-
(2005)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.52
, Issue.5
, pp. 746-775
-
-
Akdogan, E.K.1
Allahverdi, M.2
Safari, A.3
-
84
-
-
79251471106
-
Frequency response of magnetoelectric 1-3-type composites
-
K.H. Lam, C.Y. Lo, and H.L.W. Chan Frequency response of magnetoelectric 1-3-type composites J Appl Phys 107 2010 093901
-
(2010)
J Appl Phys
, vol.107
, pp. 093901
-
-
Lam, K.H.1
Lo, C.Y.2
Chan, H.L.W.3
-
86
-
-
84863438715
-
Lead-free piezoelectric single crystal based 1-3 composites for ultrasonic transducer applications
-
D. Zhou, K.H. Lam, Y. Chen, Q. Zhang, Y.C. Chiu, and H. Luo et al. Lead-free piezoelectric single crystal based 1-3 composites for ultrasonic transducer applications Sensor Actuator A Phys 182 2012 95 100
-
(2012)
Sensor Actuator A Phys
, vol.182
, pp. 95-100
-
-
Zhou, D.1
Lam, K.H.2
Chen, Y.3
Zhang, Q.4
Chiu, Y.C.5
Luo, H.6
-
87
-
-
38549106121
-
Lead-free piezoelectric BNKLT 1-3 composites
-
K.H. Lam, M.S. Guo, D.M. Lin, K.W. Kwok, and H.L.W. Chan Lead-free piezoelectric BNKLT 1-3 composites J Mater Sci 43 2008 1677 1680
-
(2008)
J Mater Sci
, vol.43
, pp. 1677-1680
-
-
Lam, K.H.1
Guo, M.S.2
Lin, D.M.3
Kwok, K.W.4
Chan, H.L.W.5
-
88
-
-
79955698595
-
High frequency PMN-PT 1-3 composite transducer for ultrasonic imaging application
-
P. Sun, G. Wang, D. Wu, B. Zhu, C. Hu, and C. Liu et al. High frequency PMN-PT 1-3 composite transducer for ultrasonic imaging application Ferroelectrics 408 01 2010 120 128
-
(2010)
Ferroelectrics
, vol.408
, Issue.1
, pp. 120-128
-
-
Sun, P.1
Wang, G.2
Wu, D.3
Zhu, B.4
Hu, C.5
Liu, C.6
-
89
-
-
0036462539
-
A 30-MHz piezo-composite ultrasound array for medical imaging applications
-
DOI 10.1109/58.985706
-
T.A. Ritter, T.R. Shrout, R. Tutwiler, and K.K. Shung A 30-MHz piezo-composite ultrasound array for medical imaging applications IEEE Trans Ultrason Ferroelect Freq Contr 49 2 2002 217 230 (Pubitemid 34278286)
-
(2002)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.49
, Issue.2
, pp. 217-230
-
-
Ritter, T.A.1
Shrout, T.R.2
Tutwiler, R.3
Shung, K.K.4
-
91
-
-
84870989619
-
Thermal-independent properties of PIN-PMN-PT single-crystal linear-array ultrasonic transducers
-
R. Chen, J. Wu, K.H. Lam, L. Yao, Q.F. Zhou, and J. Yian et al. Thermal-independent properties of PIN-PMN-PT single-crystal linear-array ultrasonic transducers IEEE Trans Ultrason Ferroelect Freq Contr 59 12 2012 2777 2784
-
(2012)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.59
, Issue.12
, pp. 2777-2784
-
-
Chen, R.1
Wu, J.2
Lam, K.H.3
Yao, L.4
Zhou, Q.F.5
Yian, J.6
-
92
-
-
84903966082
-
-
< www.philips.com/purewave >.
-
-
-
-
93
-
-
18844403357
-
EUS-guided FNA of centrally located lung tumours following a non-diagnostic bronchoscopy
-
DOI 10.1016/j.lungcan.2004.11.017, PII S0169500204006105
-
J.T. Annema, M. Veselic, and K.F. Rabe EUS-guided FNA of centrally located lung tumours following a non-diagnostic bronchoscopy Lung Cancer 48 3 2005 357 361 (Pubitemid 40693621)
-
(2005)
Lung Cancer
, vol.48
, Issue.3
, pp. 357-361
-
-
Annema, J.T.1
Veselic, M.2
Rabe, K.F.3
-
94
-
-
33750739187
-
Endoscopic ultrasound-guided celiac plexus neurolysis for pancreatic cancer pain: A single-institution experience and review of the literature
-
Q.N.H. Tran, S. Urayama, and F.J. Meyers Endoscopic ultrasound-guided celiac plexus neurolysis for pancreatic cancer pain: a single-institution experience and review of the literature J Support Oncol 4 2006 460 464
-
(2006)
J Support Oncol
, vol.4
, pp. 460-464
-
-
Tran, Q.N.H.1
Urayama, S.2
Meyers, F.J.3
-
95
-
-
0019572911
-
Pzt-epoxy piezoelectric transducers: A simplified fabrication procedure
-
DOI 10.1016/0025-5408(81)90267-1
-
H.P. Savakus, K.A. Klicker, and R.E. Newnham PZT-epoxy piezoelectric transducers: a simplified fabrication procedure Mater Res Bull 16 6 1981 677 680 (Pubitemid 12436986)
-
(1981)
Materials Research Bulletin
, vol.16
, Issue.6
, pp. 677-680
-
-
Savakus, H.P.1
Klicker, K.A.2
Newnham, R.E.3
-
96
-
-
79952029736
-
Fabrication and performance of endoscopic ultrasound radial arrays based on PMN-PT single crystal/epoxy 1-3 composite
-
D. Zhou, K.F. Cheung, Y. Chen, S.T. Lau, K.K. Shung, and H.S. Luo et al. Fabrication and performance of endoscopic ultrasound radial arrays based on PMN-PT single crystal/epoxy 1-3 composite IEEE Trans Ultrason Ferroelect Freq Contr 58 2 2011 477 484
-
(2011)
IEEE Trans Ultrason Ferroelect Freq Contr
, vol.58
, Issue.2
, pp. 477-484
-
-
Zhou, D.1
Cheung, K.F.2
Chen, Y.3
Lau, S.T.4
Shung, K.K.5
Luo, H.S.6
-
97
-
-
33751574113
-
75 MHz ultrasound biomicroscopy of anterior segment of eye
-
R.H. Silverman, J. Cannata, K.K. Shung, O. Gal, M. Patel, and H.O. Lloyd et al. 75 MHz ultrasound biomicroscopy of anterior segment of eye Ultrason Imaging 28 3 2006 179 188 (Pubitemid 44845804)
-
(2006)
Ultrasonic Imaging
, vol.28
, Issue.3
, pp. 179-188
-
-
Silverman, R.H.1
Cannata, J.2
Shung, K.K.3
Gal, O.4
Patel, M.5
Lloyd, H.O.6
Feleppa, E.J.7
Coleman, D.J.8
-
98
-
-
84875092168
-
Contrast-enhanced intravascular ultrasound pulse sequences for bandwidth-limited transducers
-
D. Maresca, G. Renaud, G. van Soest, X. Li, Q. Zhou, and K.K. Shung et al. Contrast-enhanced intravascular ultrasound pulse sequences for bandwidth-limited transducers Ultrasound Med Biol 39 4 2013 706 713
-
(2013)
Ultrasound Med Biol
, vol.39
, Issue.4
, pp. 706-713
-
-
Maresca, D.1
Renaud, G.2
Van Soest, G.3
Li, X.4
Zhou, Q.5
Shung, K.K.6
-
99
-
-
52649153102
-
Limited-angle spatial compound imaging of skin with high-frequency ultrasound (20 MHz)
-
M. Vogt, and H. Ermert Limited-angle spatial compound imaging of skin with high-frequency ultrasound (20 MHz) IEEE Trans Ultrason Ferroelectr Freq Control 55 9 2008 1975 1983
-
(2008)
IEEE Trans Ultrason Ferroelectr Freq Control
, vol.55
, Issue.9
, pp. 1975-1983
-
-
Vogt, M.1
Ermert, H.2
-
100
-
-
0038627969
-
Wound healing assessment using 20 MHz ultrasound and photography
-
DOI 10.1034/j.1600-0846.2003.00020.x
-
M. Dyson, S. Moodley, L. Verjee, W. Verling, J. Weinmann, and P. Wilson Wound healing assessment using 20 MHz ultrasound and photography Skin Res Technol 9 2 2003 116 121 (Pubitemid 36603654)
-
(2003)
Skin Research and Technology
, vol.9
, Issue.2
, pp. 116-121
-
-
Dyson, M.1
Moodley, S.2
Verjee, L.3
Verling, W.4
Weinman, J.5
Wilson, P.6
-
101
-
-
84879903337
-
A novel modulated excitation imaging system for micro ultrasound
-
W. Qiu, Y. Yu, F.K. Tsang, H. Zheng, and L. Sun A novel modulated excitation imaging system for micro ultrasound IEEE Trans Biomed Eng 60 7 2013 1884 1890
-
(2013)
IEEE Trans Biomed Eng
, vol.60
, Issue.7
, pp. 1884-1890
-
-
Qiu, W.1
Yu, Y.2
Tsang, F.K.3
Zheng, H.4
Sun, L.5
-
102
-
-
33947666048
-
PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application
-
Q. Zhou, X. Xu, E.J. Gottlieb, L. Sun, J.M. Cannata, and H. Ameri et al. PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application IEEE Trans Ultrason Ferroelectr Freq Contr 54 3 2007 668 675
-
(2007)
IEEE Trans Ultrason Ferroelectr Freq Contr
, vol.54
, Issue.3
, pp. 668-675
-
-
Zhou, Q.1
Xu, X.2
Gottlieb, E.J.3
Sun, L.4
Cannata, J.M.5
Ameri, H.6
-
103
-
-
84865211970
-
An FPGA-based open platform for ultrasound biomicroscopy
-
W. Qiu, Y. Yu, F. Tsang, and L. Sun An FPGA-based open platform for ultrasound biomicroscopy IEEE Trans Ultrason Ferroelectr Freq Contr 59 7 2012 1432 1442
-
(2012)
IEEE Trans Ultrason Ferroelectr Freq Contr
, vol.59
, Issue.7
, pp. 1432-1442
-
-
Qiu, W.1
Yu, Y.2
Tsang, F.3
Sun, L.4
-
104
-
-
84874978614
-
In vivo sonothrombolysis of ear marginal vein of rabbits monitored with high-frequency ultrasound needle transducer
-
R. Chen, D.G. Paeng, K.H. Lam, Q. Zhou, K.K. Shung, and N. Matsuoka et al. In vivo sonothrombolysis of ear marginal vein of rabbits monitored with high-frequency ultrasound needle transducer J Med Biol Eng 33 1 2012 103 110
-
(2012)
J Med Biol Eng
, vol.33
, Issue.1
, pp. 103-110
-
-
Chen, R.1
Paeng, D.G.2
Lam, K.H.3
Zhou, Q.4
Shung, K.K.5
Matsuoka, N.6
-
105
-
-
47649101081
-
A high-frame rate duplex ultrasound biomicroscopy for small animal imaging in vivo
-
DOI 10.1109/TBME.2008.919110, 15
-
L. Sun, C. Xu, W.D. Richard, C. Feng, J.A. Johnson, and K.K. Shung A high-frame rate duplex ultrasound biomicroscopy for small animal imaging In vivo IEEE Trans Biomed Eng 55 8 2008 2039 2049 (Pubitemid 352013529)
-
(2008)
IEEE Transactions on Biomedical Engineering
, vol.55
, Issue.8
, pp. 2039-2049
-
-
Sun, L.1
Xu, X.2
Richard, W.D.3
Feng, C.4
Johnson, J.A.5
Shung, K.K.6
-
106
-
-
84864666196
-
Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo
-
J.M. Yang, C. Favazza, R. Chen, J. Yao, X. Cai, and K. Maslov et al. Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo Nat Med 18 2012 1297 1302
-
(2012)
Nat Med
, vol.18
, pp. 1297-1302
-
-
Yang, J.M.1
Favazza, C.2
Chen, R.3
Yao, J.4
Cai, X.5
Maslov, K.6
-
107
-
-
84872656230
-
Ultrahigh frequency lens less ultrasonic transducers for acoustic tweezers application
-
K.H. Lam, H.S. Hsu, Y. Li, C. Lee, A. Lin, and Q. Zhou et al. Ultrahigh frequency lens less ultrasonic transducers for acoustic tweezers application Biotechnol Bioeng 110 3 2013 881 886
-
(2013)
Biotechnol Bioeng
, vol.110
, Issue.3
, pp. 881-886
-
-
Lam, K.H.1
Hsu, H.S.2
Li, Y.3
Lee, C.4
Lin, A.5
Zhou, Q.6
-
108
-
-
84882365062
-
Ultrahigh frequency ultrasound microbeam for biomedical applications
-
K.H. Lam, Y. Li, C. Lee, Q. Zhou, and K.K. Shung Ultrahigh frequency ultrasound microbeam for biomedical applications Proc IEEE Ultrason Symp 2012 1994 1997
-
(2012)
Proc IEEE Ultrason Symp
, pp. 1994-1997
-
-
Lam, K.H.1
Li, Y.2
Lee, C.3
Zhou, Q.4
Shung, K.K.5
-
109
-
-
84896409198
-
Investigating contactless high frequency ultrasound microbeam stimulation for determination of invasion potential of breast cancer cells
-
J.Y. Hwang, N.S. Lee, C. Lee, K.H. Lam, H.H. Kim, and J. Woo et al. Investigating contactless high frequency ultrasound microbeam stimulation for determination of invasion potential of breast cancer cells Biotechnol Bioeng 110 10 2013 2697 2705
-
(2013)
Biotechnol Bioeng
, vol.110
, Issue.10
, pp. 2697-2705
-
-
Hwang, J.Y.1
Lee, N.S.2
Lee, C.3
Lam, K.H.4
Kim, H.H.5
Woo, J.6
-
110
-
-
81155150381
-
Acoustic aligning and trapping of microbubbles in an enclosed PDMS microfluidic device
-
L. Meng, F. Cai, Q. Jin, L. Niu, C. Jiang, and Z. Wang et al. Acoustic aligning and trapping of microbubbles in an enclosed PDMS microfluidic device Sensor Actuator B Chem 160 2011 1599 1605
-
(2011)
Sensor Actuator B Chem
, vol.160
, pp. 1599-1605
-
-
Meng, L.1
Cai, F.2
Jin, Q.3
Niu, L.4
Jiang, C.5
Wang, Z.6
-
111
-
-
84860335127
-
Precise and programmable manipulation of microbubbles by two-dimensional standing surface acoustic waves
-
L. Meng, F. Cai, J. Chen, L. Niu, Y. Li, and J. Wu et al. Precise and programmable manipulation of microbubbles by two-dimensional standing surface acoustic waves Appl Phys Lett 100 2012 173701
-
(2012)
Appl Phys Lett
, vol.100
, pp. 173701
-
-
Meng, L.1
Cai, F.2
Chen, J.3
Niu, L.4
Li, Y.5
Wu, J.6
|