Volumn , Issue , 2008, Pages 1308-1310

A hydrostatic calibration method for the design of wearable PAT-based blood pressure monitoring devices

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; BLOOD PRESSURE; CALIBRATION; ESTIMATION; HYDRAULICS; HYDRODYNAMICS; HYDROSTATIC PRESSURE;

EID: 84903877020     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (17)

References (8)
  • 2
    • 34547357474 scopus 로고    scopus 로고
    • A health-shirt using e-textile materials for the continuous and cuffless monitoring of arterial blood pressure
    • Boston, U.S.A, Sept
    • Y.T. Zhang, C.C.Y. Poon, CH. Chan, M.W.W. Tsang, and K.F. Wu, "A health-shirt using e-textile materials for the continuous and cuffless monitoring of arterial blood pressure," in Proc. 3rd IEEE-EMBS ISSS-MDBS, Boston, U.S.A., Sept. 2006, pp. 86-89.
    • (2006) Proc. 3rd IEEE-EMBS ISSS-MDBS , pp. 86-89
    • Zhang, Y.T.1    Poon, C.C.Y.2    Chan, C.H.3    Tsang, M.W.W.4    Wu, K.F.5
  • 3
    • 61849094544 scopus 로고    scopus 로고
    • Blood pressure monitoring apparatus,
    • U.S. Patent 5 7556 69, May 26
    • ONO KOHEI, and KASUYA HIROMITSU, "Blood pressure monitoring apparatus," U.S. Patent 5 7556 69, May 26, 1998.
    • (1998)
    • KOHEI, O.1    HIROMITSU, K.2
  • 6
    • 34547264374 scopus 로고    scopus 로고
    • Modeling of Pulse Transit Time under the Effects of Hydrostatic Pressure for Cuffless Blood Pressure Measurements
    • Boston, U.S.A, Sept
    • C. C. Y. Poon, Yuan-Ting Zhang, and Yinbo Liu, "Modeling of Pulse Transit Time under the Effects of Hydrostatic Pressure for Cuffless Blood Pressure Measurements," in 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors, Boston, U.S.A., Sept. 2006, pp. 65-68.
    • (2006) 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors , pp. 65-68
    • Poon, C.C.Y.1    Zhang, Y.-T.2    Liu, Y.3
  • 7
    • 33644822671 scopus 로고    scopus 로고
    • Pulse transit time measured from the ECG: An unreliable marker of beat-to-beat blood pressure
    • R. A. Payne, C. N. Symeonides, D. J. Webb, and S. R. J. Maxwell, "Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure," J Appl Physiol, 100: 136-141, 2006,
    • (2006) J Appl Physiol , vol.100 , pp. 136-141
    • Payne, R.A.1    Symeonides, C.N.2    Webb, D.J.3    Maxwell, S.R.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.