메뉴 건너뛰기




Volumn 131, Issue , 2014, Pages 56-66

Balancing envelope and heating system parameters for zero emissions retrofit using building sensor data

Author keywords

Building monitoring; Emission free retrofit; Retrofit analysis; Sensor network

Indexed keywords

CARBON DIOXIDE; CARBON FOOTPRINT; COMPUTER SIMULATION; ENERGY UTILIZATION; GREENHOUSE GASES; HEATING; HEATING EQUIPMENT; RETROFITTING; SENSOR NETWORKS;

EID: 84903836680     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2014.06.024     Document Type: Article
Times cited : (54)

References (45)
  • 1
    • 84903843091 scopus 로고    scopus 로고
    • European Commission. Energy efficiency plan (com/2011/0109 final). Tech. rep., Communication;.
    • European Commission. Energy efficiency plan (com/2011/0109 final). Tech. rep., Communication; 2011.
    • (2011)
  • 2
    • 85021217349 scopus 로고    scopus 로고
    • Mobilisierung der energetischen erneuerungspotenziale im wohnbaubestand. Tech. rep.
    • Ott W, Jakob M, Baur M, Kaufmann Y, Ott A. Mobilisierung der energetischen erneuerungspotenziale im wohnbaubestand. Tech. rep., Bundesamt für Energie; 2005.
    • (2005) Bundesamt für Energie
    • Ott, W.1    Jakob, M.2    Baur, M.3    Kaufmann, Y.4    Ott, A.5
  • 4
    • 85021213551 scopus 로고    scopus 로고
    • Akteure und Sanierungsgeheimnisse - Überblick, WWF workshop Sanierungsrate Hochschrauben - aber wie?, Zürich
    • Ott W. Akteure und Sanierungsgeheimnisse - Überblick. In: WWF workshop Sanierungsrate Hochschrauben - aber wie?, Zürich; 2013.
    • (2013)
    • Ott, W.1
  • 6
    • 84903824004 scopus 로고    scopus 로고
    • SIA Standard 380/1. Swiss association of engineers and architects (in German), Zurich, Switzerland.
    • SIA Standard 380/1. Swiss association of engineers and architects (in German), Zurich, Switzerland 2005.
    • (2005)
  • 8
    • 84862843865 scopus 로고    scopus 로고
    • Introducing the prebound effect: the gap between performance and actual energy consumption
    • Sunikka-Blank M., Galvin R. Introducing the prebound effect: the gap between performance and actual energy consumption. Build Res Inform 2012, 40:260-273.
    • (2012) Build Res Inform , vol.40 , pp. 260-273
    • Sunikka-Blank, M.1    Galvin, R.2
  • 9
    • 84876971423 scopus 로고    scopus 로고
    • Zero energy buildings and sustainable development implications - a review
    • Li D.H.W., Yang L., Lam J.C. Zero energy buildings and sustainable development implications - a review. Energy 2013, 54:1-10.
    • (2013) Energy , vol.54 , pp. 1-10
    • Li, D.H.W.1    Yang, L.2    Lam, J.C.3
  • 10
    • 79951517816 scopus 로고    scopus 로고
    • Zero energy building - a review of definitions and calculation methodologies
    • Marszal A., Heiselberg P., Bourrelle J., Musall E., Voss K., Sartori I., et al. Zero energy building - a review of definitions and calculation methodologies. Energy Build 2011, 43(4):971-979.
    • (2011) Energy Build , vol.43 , Issue.4 , pp. 971-979
    • Marszal, A.1    Heiselberg, P.2    Bourrelle, J.3    Musall, E.4    Voss, K.5    Sartori, I.6
  • 11
    • 85021222025 scopus 로고    scopus 로고
    • Optimizing the combination of active and passive building components in refurbishment projects to allow for net-zero emission architecture. Ph.D. thesis, Diss.
    • Ritter V. Optimizing the combination of active and passive building components in refurbishment projects to allow for net-zero emission architecture. Ph.D. thesis, Diss., Eidgenössische Technische Hochschule ETH Zürich, Nr. 20510; 2012.
    • (2012) Eidgenössische Technische Hochschule ETH Zürich, Nr. 20510
    • Ritter, V.1
  • 12
    • 85021196926 scopus 로고    scopus 로고
    • Balancing active and passive building components to achieve minimal greenhous gas emissions in refurbishment projects. Ph.D. thesis
    • Ritter V, Haller N, Leibundgut H. Balancing active and passive building components to achieve minimal greenhous gas emissions in refurbishment projects. Ph.D. thesis, CLIMA 2013 Prague; June 2013.
    • (2013) CLIMA 2013 Prague; June
    • Ritter, V.1    Haller, N.2    Leibundgut, H.3
  • 13
    • 77955710386 scopus 로고    scopus 로고
    • Advances in heat pump systems: a review
    • Chua K.J., Chou S.K., Yang W.M. Advances in heat pump systems: a review. Appl Energy 2010, 87:3611-3624.
    • (2010) Appl Energy , vol.87 , pp. 3611-3624
    • Chua, K.J.1    Chou, S.K.2    Yang, W.M.3
  • 14
    • 57749169961 scopus 로고    scopus 로고
    • Building information model based energy/exergy performance assessment in early design stages
    • Schlueter A., Thesseling F. Building information model based energy/exergy performance assessment in early design stages. Autom Construct 2009, 18(2):153-163.
    • (2009) Autom Construct , vol.18 , Issue.2 , pp. 153-163
    • Schlueter, A.1    Thesseling, F.2
  • 15
    • 84861799500 scopus 로고    scopus 로고
    • Simulation-based decision support tool for early stages of zero-energy building design
    • Attia S., Gratia E., DeHerde A., Hensen J.L. Simulation-based decision support tool for early stages of zero-energy building design. Energy Build 2012, 49:2-15.
    • (2012) Energy Build , vol.49 , pp. 2-15
    • Attia, S.1    Gratia, E.2    DeHerde, A.3    Hensen, J.L.4
  • 16
    • 29144454220 scopus 로고    scopus 로고
    • Climate warming impact on degree-days and building energy demand in switzerland
    • Christenson M., Manz H., Gyalistras D. Climate warming impact on degree-days and building energy demand in switzerland. Energy Convers Manage 2006, 47(6):671-686.
    • (2006) Energy Convers Manage , vol.47 , Issue.6 , pp. 671-686
    • Christenson, M.1    Manz, H.2    Gyalistras, D.3
  • 17
    • 84903850470 scopus 로고
    • SIA Standard 381/3: Heating degree-days in Switzerland, Swiss Association of Engineers and Architects, Zurich, Switzerland.
    • SIA Standard 381/3: Heating degree-days in Switzerland, Swiss Association of Engineers and Architects, Zurich, Switzerland 1982.
    • (1982)
  • 18
    • 85021219937 scopus 로고    scopus 로고
    • http://www.meteoswiss.admin.ch/web/en.html.
  • 19
    • 84859613493 scopus 로고    scopus 로고
    • Analysis of building electric energy consumption data using an improved cooling degree day method
    • Krese G., Prek M., Butala V. Analysis of building electric energy consumption data using an improved cooling degree day method. J Mech Eng 2012, 58(2):107-114.
    • (2012) J Mech Eng , vol.58 , Issue.2 , pp. 107-114
    • Krese, G.1    Prek, M.2    Butala, V.3
  • 20
    • 85021243191 scopus 로고    scopus 로고
    • http://www.carbontrust.com/media/18223/ctl153_conversion_factors.pdf.
  • 21
    • 80053586673 scopus 로고    scopus 로고
    • Virtual sensors for estimation of energy consumption and thermal comfort in buildings with underfloor heating
    • Ploennigs J., Ahmed A., Hensel B., Stack P., Menzel K. Virtual sensors for estimation of energy consumption and thermal comfort in buildings with underfloor heating. Adv Eng Inform 2011, 25(4):688-698.
    • (2011) Adv Eng Inform , vol.25 , Issue.4 , pp. 688-698
    • Ploennigs, J.1    Ahmed, A.2    Hensel, B.3    Stack, P.4    Menzel, K.5
  • 22
    • 79956369311 scopus 로고    scopus 로고
    • Identifying suitable models for the heat dynamics of buildings
    • Bacher P., Madsen H. Identifying suitable models for the heat dynamics of buildings. Energy Build 2011, 43(7):1511-1522.
    • (2011) Energy Build , vol.43 , Issue.7 , pp. 1511-1522
    • Bacher, P.1    Madsen, H.2
  • 23
    • 84903828673 scopus 로고    scopus 로고
    • MATLAB, version 8.1.0 (R2013a), The MathWorks Inc., Natick, MA, USA;
    • MATLAB, version 8.1.0 (R2013a), The MathWorks Inc., Natick, MA, USA; 2013.
    • (2013)
  • 24
    • 0023960364 scopus 로고
    • Parameter estimation in buildings: methods for dynamic analysis of measured energy use
    • Rabl A. Parameter estimation in buildings: methods for dynamic analysis of measured energy use. J Solar Energy Eng 1988, 110:52-66.
    • (1988) J Solar Energy Eng , vol.110 , pp. 52-66
    • Rabl, A.1
  • 25
    • 2142721301 scopus 로고
    • Dynamic models of house heating based on equivalent thermal parameters. Ph.D. thesis
    • Sonderegger R. Dynamic models of house heating based on equivalent thermal parameters. Ph.D. thesis, Princeton University, NJ, USA; 1978.
    • (1978) Princeton University, NJ, USA
    • Sonderegger, R.1
  • 26
    • 13544258963 scopus 로고
    • Diagnostic tests for determining the thermal response of a house
    • Sonderegger R. Diagnostic tests for determining the thermal response of a house. ASHRAE Trans 1978, 84(1):691-703.
    • (1978) ASHRAE Trans , vol.84 , Issue.1 , pp. 691-703
    • Sonderegger, R.1
  • 27
    • 85021246277 scopus 로고
    • Test hut validation of a microcomputer predictive HVAC control, ASHRAE
    • Shapiro M, Yager AJ, Ngan T. Test hut validation of a microcomputer predictive HVAC control, ASHRAE; 1988.
    • (1988)
    • Shapiro, M.1    Yager, A.J.2    Ngan, T.3
  • 28
    • 0020752303 scopus 로고
    • A graphical method for passive building energy analysis
    • Subbarao K., Anderson J.V. A graphical method for passive building energy analysis. J Solar Energy Eng 1983, 105(2):134-141. http://dx.doi.org/10.1115/1.3266356.
    • (1983) J Solar Energy Eng , vol.105 , Issue.2 , pp. 134-141
    • Subbarao, K.1    Anderson, J.V.2
  • 29
    • 85021241252 scopus 로고
    • BEVA (building element vector analysis) - a new hour-by-hour building energy simulation with system parameters as inputs, SERI/TR-254-2195
    • Subbarao K. BEVA (building element vector analysis) - a new hour-by-hour building energy simulation with system parameters as inputs, SERI/TR-254-2195. Solar Energy Research Institute, Golden, CO; 1984.
    • (1984) Solar Energy Research Institute, Golden, CO
    • Subbarao, K.1
  • 32
    • 0026960841 scopus 로고
    • Energy signature models for commercial buildings: test with measured data and interpretation
    • Rabl A., Rialhe A. Energy signature models for commercial buildings: test with measured data and interpretation. Energy Build 1992, 19(2):143-154.
    • (1992) Energy Build , vol.19 , Issue.2 , pp. 143-154
    • Rabl, A.1    Rialhe, A.2
  • 34
    • 85021241051 scopus 로고    scopus 로고
    • http://www.arduino.cc.
  • 35
    • 85021240450 scopus 로고    scopus 로고
    • http://www.sensirion.com.
  • 36
    • 85021252149 scopus 로고    scopus 로고
    • http://www.maximintegrated.com.
  • 37
    • 85021236869 scopus 로고    scopus 로고
    • http://www.endress.com.
  • 39
  • 40
    • 85021188129 scopus 로고    scopus 로고
    • http://www.sketchup.com.
  • 41
    • 84903833721 scopus 로고    scopus 로고
    • A. Ashrae guideline 14-2002 for measurement of energy and demand savings, American Society of Heating, Refrigeration and Air Conditioning Engineers Atlanta, GA; 2002.
    • A.2002, Ashrae guideline 14-2002 for measurement of energy and demand savings, American Society of Heating, Refrigeration and Air Conditioning Engineers Atlanta, GA; 2002.
    • (2002)
  • 42
    • 84903836928 scopus 로고    scopus 로고
    • SIA Standard 2024, Swiss Association of Engineers and Architects (in German), Zurich, Switzerland
    • SIA Standard 2024, Swiss Association of Engineers and Architects (in German), Zurich, Switzerland 2006.
    • (2006)
  • 43
    • 84903832262 scopus 로고
    • ISO Standard 9869:1994: Thermal insulation - building elements - in-situ measurement of thermal resistance and thermal transmittance. International Organization for Standardization
    • ISO Standard 9869:1994: Thermal insulation - building elements - in-situ measurement of thermal resistance and thermal transmittance. International Organization for Standardization; 1994.
    • (1994)
  • 44
    • 84903825725 scopus 로고    scopus 로고
    • ASTM Standard C1046-95: Standard practice for in-situ measurement of heat flux and temperature on building envelope components. ASTM International, West Conshohocken, PA
    • ASTM Standard C1046-95: Standard practice for in-situ measurement of heat flux and temperature on building envelope components. ASTM International, West Conshohocken, PA; 2013.
    • (2013)
  • 45
    • 85021217079 scopus 로고    scopus 로고
    • http://www.braunmesstechnik.de.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.