메뉴 건너뛰기




Volumn 81, Issue , 2014, Pages 81-91

Experimental analysis of the transport of airborne contaminants between adjacent rooms at different pressure due to the door opening

Author keywords

Differential pressurization; Dirty air transfer; Door operation effect; Infective aseptic room contamination

Indexed keywords

PRESSURIZATION;

EID: 84903824330     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2014.05.031     Document Type: Article
Times cited : (25)

References (15)
  • 1
    • 17444368830 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta GA, ASHRAE
    • ASHRAE HVAC design manual for hospitals and clinics 2003, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta GA.
    • (2003) HVAC design manual for hospitals and clinics
  • 2
    • 33847142204 scopus 로고    scopus 로고
    • Dispersion of expiratory droplets in a general hospital ward with ceiling mixing type mechanical ventilation system
    • Wan M.P., Chao C.Y.H., Ng Y.D., Sze To G.N., Yu W.C. Dispersion of expiratory droplets in a general hospital ward with ceiling mixing type mechanical ventilation system. Aerosol Sci Technol 2007, 41:244-258.
    • (2007) Aerosol Sci Technol , vol.41 , pp. 244-258
    • Wan, M.P.1    Chao, C.Y.H.2    Ng, Y.D.3    Sze To, G.N.4    Yu, W.C.5
  • 3
    • 55549134645 scopus 로고    scopus 로고
    • An experimental study on ventilation efficiency of isolation room
    • Tung Y.C., Hu S.C., Tsai T.I., Chang I.L. An experimental study on ventilation efficiency of isolation room. Build Environ 2009, 44:271-279.
    • (2009) Build Environ , vol.44 , pp. 271-279
    • Tung, Y.C.1    Hu, S.C.2    Tsai, T.I.3    Chang, I.L.4
  • 4
    • 0035149576 scopus 로고    scopus 로고
    • An evaluation of hospital special - ventilation - room pressures
    • Rice N., Streifel A., Vesley D. An evaluation of hospital special - ventilation - room pressures. Infect Control Hosp Epidemiol 2001, 22(1):19-23.
    • (2001) Infect Control Hosp Epidemiol , vol.22 , Issue.1 , pp. 19-23
    • Rice, N.1    Streifel, A.2    Vesley, D.3
  • 5
    • 0036285649 scopus 로고    scopus 로고
    • Asimple method for tracer containment testing of hospital isolation rooms
    • Rydock J.P. Asimple method for tracer containment testing of hospital isolation rooms. Appl Occup Environ Hyg 2002, 17(7):486-490.
    • (2002) Appl Occup Environ Hyg , vol.17 , Issue.7 , pp. 486-490
    • Rydock, J.P.1
  • 6
    • 3242772215 scopus 로고    scopus 로고
    • Contaiment testing of isolation rooms
    • Rydock J.P., Eian P.K. Contaiment testing of isolation rooms. JHosp Infect 2004, 57:228-232.
    • (2004) JHosp Infect , vol.57 , pp. 228-232
    • Rydock, J.P.1    Eian, P.K.2
  • 7
    • 34250195734 scopus 로고    scopus 로고
    • Aperformance assessment of airborne infection isolation rooms
    • Saravia S.A., Raynor P.C., Streifel A.J. Aperformance assessment of airborne infection isolation rooms. Am J Infect Control 2007, 35(5):324-331.
    • (2007) Am J Infect Control , vol.35 , Issue.5 , pp. 324-331
    • Saravia, S.A.1    Raynor, P.C.2    Streifel, A.J.3
  • 8
    • 33846411052 scopus 로고    scopus 로고
    • Development of an empirical model to aid in designing airborne infection isolation rooms
    • Hayden C.S., Earnest G.S., Jensen P.A. Development of an empirical model to aid in designing airborne infection isolation rooms. JOccup Environ Hyg 2007, 4(3):198-207.
    • (2007) JOccup Environ Hyg , vol.4 , Issue.3 , pp. 198-207
    • Hayden, C.S.1    Earnest, G.S.2    Jensen, P.A.3
  • 9
    • 29444455397 scopus 로고    scopus 로고
    • Door opening motion can potentially lead to a transient breakdown in negative-pressure isolation conditions: the importance of vorticity and buoyancy airflows
    • Tang J.W., Eames I., Li Y., Taha Y.A., Wilson P., Bellingan G., et al. Door opening motion can potentially lead to a transient breakdown in negative-pressure isolation conditions: the importance of vorticity and buoyancy airflows. JHosp Infect 2005, 61:283-286.
    • (2005) JHosp Infect , vol.61 , pp. 283-286
    • Tang, J.W.1    Eames, I.2    Li, Y.3    Taha, Y.A.4    Wilson, P.5    Bellingan, G.6
  • 10
    • 61349127826 scopus 로고    scopus 로고
    • Numerical study on the dispersion of airborne contaminants from an isolation room in the case of door opening
    • Tung Y.C., Shih Y.C., Hu S.C. Numerical study on the dispersion of airborne contaminants from an isolation room in the case of door opening. Appl Therm Eng 2009, 29:1544-1551.
    • (2009) Appl Therm Eng , vol.29 , pp. 1544-1551
    • Tung, Y.C.1    Shih, Y.C.2    Hu, S.C.3
  • 11
    • 73449091143 scopus 로고    scopus 로고
    • Movement of airborne contaminants in a hospital isolation room
    • Eames I., Shoaib C.A., Klettner C.A., Tabam V. Movement of airborne contaminants in a hospital isolation room. JR Soc Interface 2009, 6(Suppl.6):S757-S766.
    • (2009) JR Soc Interface , vol.6 , Issue.SUPPL. 6
    • Eames, I.1    Shoaib, C.A.2    Klettner, C.A.3    Tabam, V.4
  • 12
    • 79952312405 scopus 로고    scopus 로고
    • The effect of pressure differential and care provider movement on airborne infectious isolation room containment effectiveness
    • Adams N.J., Johnson D.L., Lynch R.A. The effect of pressure differential and care provider movement on airborne infectious isolation room containment effectiveness. Am J Infect Control 2011, 39(2):91-97.
    • (2011) Am J Infect Control , vol.39 , Issue.2 , pp. 91-97
    • Adams, N.J.1    Johnson, D.L.2    Lynch, R.A.3
  • 13
    • 84879474963 scopus 로고    scopus 로고
    • Different types of door motions as contributing factors to containment failures in hospital isolation rooms
    • Tang W., Nicolle A., Pantelic J., Klettner C.A., Su R., Kalliomaki P., et al. Different types of door motions as contributing factors to containment failures in hospital isolation rooms. PLoS One 2013, 8(6):e66663.
    • (2013) PLoS One , vol.8 , Issue.6
    • Tang, W.1    Nicolle, A.2    Pantelic, J.3    Klettner, C.A.4    Su, R.5    Kalliomaki, P.6
  • 15
    • 3042782602 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta GA, ASHRAE
    • ASHRAE Handbook application 1999, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta GA.
    • (1999) Handbook application


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.