메뉴 건너뛰기




Volumn 9, Issue , 2013, Pages S33-S37

Subclavian TAVI: More than an alternative access route

Author keywords

Subclavian approach; Transcatheter aortic valve implantation

Indexed keywords

ARTERY DISEASE; ARTICLE; CARDIOVASCULAR DISEASE; FEASIBILITY STUDY; GENERAL ANESTHESIA; HIGH RISK POPULATION; HUMAN; LEG ARTERY; PATIENT CARE; PEROPERATIVE COMPLICATION; POSTOPERATIVE COMPLICATION; PROGNOSIS; SUBCLAVIAN ARTERY; TRANSAORTIC ACCESS; TRANSAPICAL ACCESS; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT CONTRAINDICATION; VASCULAR ACCESS; AORTA; AORTA VALVE; AORTA VALVE STENOSIS; COMPARATIVE STUDY; DISEASE MANAGEMENT; DRUG CONTRAINDICATION; EQUIPMENT; FEMORAL ARTERY; HEART CATHETERIZATION; HEART VALVE REPLACEMENT; METHODOLOGY; REVIEW; RISK FACTOR;

EID: 84903506707     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV9SSA7     Document Type: Article
Times cited : (32)

References (33)
  • 1
    • 65149095001 scopus 로고    scopus 로고
    • Outcomes and safety of percutaneous aortic valve replacement
    • Zajarias A, Cribier AG. Outcomes and safety of percutaneous aortic valve replacement. J Am Coll Cardiol. 2009;53:1829-36.
    • (2009) J Am Coll Cardiol. , vol.53 , pp. 1829-1836
    • Zajarias, A.1    Cribier, A.G.2
  • 4
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den Heijer P, Linke A, Luha O, Ramondo A, Ussia G, Wenaweser P, Windecker S, Laborde JC, de Jaegere P, Serruys PW. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention. 2008;4:242-9.
    • (2008) EuroIntervention. , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.C.11    De Jaegere, P.12    Serruys, P.W.13
  • 5
    • 79961022681 scopus 로고    scopus 로고
    • One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: The European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, Eggebrecht H, Rubino P, Colombo A, Lange R, Schwarz RR, Wendler O. One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2011;124:425-33.
    • (2011) Circulation. , vol.124 , pp. 425-433
    • Thomas, M.1    Schymik, G.2    Walther, T.3    Himbert, D.4    Lefevre, T.5    Treede, H.6    Eggebrecht, H.7    Rubino, P.8    Colombo, A.9    Lange, R.10    Schwarz, R.R.11    Wendler, O.12
  • 12
    • 77956882878 scopus 로고    scopus 로고
    • Aortic valve implantation with the CoreValve revalving system via left carotid artery access: First case report
    • Modine T, Lemesle G, Azzaoui R, Sudre A. Aortic valve implantation with the CoreValve revalving system via left carotid artery access: first case report. J Thorac Cardiovasc Surg. 2010;140:928-9.
    • (2010) J Thorac Cardiovasc Surg. , vol.140 , pp. 928-929
    • Modine, T.1    Lemesle, G.2    Azzaoui, R.3    Sudre, A.4
  • 24
    • 85034057149 scopus 로고    scopus 로고
    • Result from the ADVANCE study
    • Munich, Germany
    • Brecker S. Result from the ADVANCE study. ESC 2012. Munich, Germany.
    • ESC 2012
    • Brecker, S.1
  • 27
    • 84878109980 scopus 로고    scopus 로고
    • Incidence, predictors and impact of bleeding after transcatheter aortic valve implantation using the balloon-expandable Edwards prosthesis
    • Borz B, Durand E, Godin M, Tron C, Canville A, Litzler PY, Bessou JP, Cribier A, Eltchaninoff H. Incidence, predictors and impact of bleeding after transcatheter aortic valve implantation using the balloon-expandable Edwards prosthesis. Heart. 2013;99:860-5.
    • (2013) Heart. , vol.99 , pp. 860-865
    • Borz, B.1    Durand, E.2    Godin, M.3    Tron, C.4    Canville, A.5    Litzler, P.Y.6    Bessou, J.P.7    Cribier, A.8    Eltchaninoff, H.9
  • 31
    • 84869086499 scopus 로고    scopus 로고
    • Transcutaneous aortic valve implantation using the axillary/subclavian access with patent left internal thoracic artery to left anterior descending artery: Feasibility and early clinical outcomes
    • Modine T, Sudre A, Collet F, Delhaye C, Lemesles G, Fayad G, Koussa M. Transcutaneous aortic valve implantation using the axillary/subclavian access with patent left internal thoracic artery to left anterior descending artery: feasibility and early clinical outcomes. J Thorac Cardiovasc Surg. 2012;144:1416-20.
    • (2012) J Thorac Cardiovasc Surg. , vol.144 , pp. 1416-1420
    • Modine, T.1    Sudre, A.2    Collet, F.3    Delhaye, C.4    Lemesles, G.5    Fayad, G.6    Koussa, M.7
  • 33


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.