메뉴 건너뛰기




Volumn 81, Issue , 2014, Pages 37-41

Thermal comfort of the surgical staff in the operating room

Author keywords

Operating room; Standards and guidelines; Survey; Thermal comfort

Indexed keywords

AIR CONDITIONING; INDOOR AIR POLLUTION; OPERATING ROOMS; SURGERY; SURVEYING; SURVEYS; THERMAL COMFORT;

EID: 84903463604     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2014.05.036     Document Type: Article
Times cited : (66)

References (28)
  • 1
    • 33846995618 scopus 로고    scopus 로고
    • HVAC and indoor thermal conditions in hospital operating rooms
    • Balaras C.A., Dascalaki E., Gaglia A. HVAC and indoor thermal conditions in hospital operating rooms. Energy Build 2007, 39(4):454-470.
    • (2007) Energy Build , vol.39 , Issue.4 , pp. 454-470
    • Balaras, C.A.1    Dascalaki, E.2    Gaglia, A.3
  • 2
    • 78651438294 scopus 로고    scopus 로고
    • Thermal comfort of patients: objective and subjective measurements in patient rooms of a Belgian healthcare facility
    • Verheyen J., Theys N., Allonsius L., Descamps F. Thermal comfort of patients: objective and subjective measurements in patient rooms of a Belgian healthcare facility. Build Environ 2011, 46(5):1195-1204.
    • (2011) Build Environ , vol.46 , Issue.5 , pp. 1195-1204
    • Verheyen, J.1    Theys, N.2    Allonsius, L.3    Descamps, F.4
  • 3
    • 77952586222 scopus 로고    scopus 로고
    • On the applicability of the laminar flow index when selecting surgical lighting
    • Zoon W., van der Heijden M., Loomans M., Hensen J. On the applicability of the laminar flow index when selecting surgical lighting. Build Environ 2010, 45(9):1976-1983.
    • (2010) Build Environ , vol.45 , Issue.9 , pp. 1976-1983
    • Zoon, W.1    van der Heijden, M.2    Loomans, M.3    Hensen, J.4
  • 4
    • 33746174578 scopus 로고    scopus 로고
    • The integrated effect of medical lamp position and diffuser discharge velocity on ultra-clean ventilation performance in an operating theatre
    • Chow T.T. The integrated effect of medical lamp position and diffuser discharge velocity on ultra-clean ventilation performance in an operating theatre. Indoor Built Environ 2006, 15(4):315-331.
    • (2006) Indoor Built Environ , vol.15 , Issue.4 , pp. 315-331
    • Chow, T.T.1
  • 10
    • 85029168938 scopus 로고    scopus 로고
    • Health care facilities
    • [Chapter 7] R.American Society for Heating, air-conditioning Engineers Inc
    • R.American Society for Heating, air-conditioning Engineers Inc Health care facilities. ASHRAE handbook: HVAC Applications, Michigan 2007, [Chapter 7].
    • (2007) ASHRAE handbook: HVAC Applications, Michigan
  • 11
    • 84870420394 scopus 로고    scopus 로고
    • Measured and perceived indoor environmental quality: Padua hospital case study
    • De Giuli V., Zecchin R., Salmaso L., Corain L., De Carli M. Measured and perceived indoor environmental quality: Padua hospital case study. Build Environ 2013, 59:211-226.
    • (2013) Build Environ , vol.59 , pp. 211-226
    • De Giuli, V.1    Zecchin, R.2    Salmaso, L.3    Corain, L.4    De Carli, M.5
  • 12
    • 58949104767 scopus 로고    scopus 로고
    • Thermal comfort in residential buildings: comfort values and scales for building energy simulation
    • Peeters L., Dear R.D., Hensen J., Dhaeseleer W. Thermal comfort in residential buildings: comfort values and scales for building energy simulation. Appl Energy 2009, 86(5):772-780.
    • (2009) Appl Energy , vol.86 , Issue.5 , pp. 772-780
    • Peeters, L.1    Dear, R.D.2    Hensen, J.3    Dhaeseleer, W.4
  • 25
    • 84860449556 scopus 로고    scopus 로고
    • Thermal comfort standards, measured internal temperatures and thermal resilience to climate change of free-running buildings: a case-study of hospital wards
    • Lomas K., Giridharan R. Thermal comfort standards, measured internal temperatures and thermal resilience to climate change of free-running buildings: a case-study of hospital wards. Build Environ 2012, 55:57-72.
    • (2012) Build Environ , vol.55 , pp. 57-72
    • Lomas, K.1    Giridharan, R.2
  • 26
    • 84874560538 scopus 로고    scopus 로고
    • Updating the adaptive relation between climate and comfort indoors; new insights and an extended database
    • Humphreys M., Rijal H., Nicol J. Updating the adaptive relation between climate and comfort indoors; new insights and an extended database. Build Environ 2013, 63:40-55.
    • (2013) Build Environ , vol.63 , pp. 40-55
    • Humphreys, M.1    Rijal, H.2    Nicol, J.3
  • 27
    • 80053924924 scopus 로고    scopus 로고
    • Adaptive comfort: analysis and application of the main indices
    • Ferrari S., Zanotto V. Adaptive comfort: analysis and application of the main indices. Build Environ 2012, 49:25-32.
    • (2012) Build Environ , vol.49 , pp. 25-32
    • Ferrari, S.1    Zanotto, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.