1
-
-
78651577396
-
-
NETL. Pittsburgh, PA, USA, U.S. Department of Energy, Jun. [Online]
-
NETL. The Modern Grid Strategy: A vision for the smart grid. Pittsburgh, PA, USA, U.S. Department of Energy, Jun. 2009 [Online]. Available: http://www.netl.doe.gov/smartgrid/refshelf.html#White Papers
-
(2009)
The Modern Grid Strategy: A Vision for the Smart Grid
-
-
-
2
-
-
0038493693
-
Line inspections: Eyes and ears of RCM
-
N. Kilroe, "Line inspections: Eyes and ears of RCM," in Proc. IEEE 10th Int. Conf. ESMC, 2003, pp. 18-24.
-
(2003)
Proc. IEEE 10th Int. Conf. ESMC
, pp. 18-24
-
-
Kilroe, N.1
-
3
-
-
77951546853
-
Determining the probability of flashover occurrence in composite insulators by using leakage current harmonic components
-
H. H. Kordkheili, H. Abravesh, M. Tabasi, M. Dakhem, and M. M. Abravesh, "Determining the probability of flashover occurrence in composite insulators by using leakage current harmonic components," IEEE Trans. Dielectr. Electr. Insul., vol. 17, no. 2, pp. 502-512, 2010.
-
(2010)
IEEE Trans. Dielectr. Electr. Insul.
, vol.17
, Issue.2
, pp. 502-512
-
-
Kordkheili, H.H.1
Abravesh, H.2
Tabasi, M.3
Dakhem, M.4
Abravesh, M.M.5
-
4
-
-
33847749870
-
Inferring ceramic insulator pollution by an innovative approach resorting to PD detection
-
DOI 10.1109/TDEI.2007.302866
-
C. Andrea, S. Chandrasekar, M. G. Carlo, and P. Francesco, "Inferring ceramic insulator pollution by an innovative approach resorting to PD detection," IEEE Trans. Dielectr. Electr. Insul., vol. 14, no. 1, pp. 23-29, 2007. (Pubitemid 46375878)
-
(2007)
IEEE Transactions on Dielectrics and Electrical Insulation
, vol.14
, Issue.1
, pp. 23-29
-
-
Cavallini, A.1
Chandrasekar, S.2
Montanari, G.C.3
Puletti, F.4
-
5
-
-
49449118567
-
Impact of weathering on flashover performance of nonceramic insulators
-
S. Venkataraman, R. S. Gorur, and A. P. Mishra, "Impact of weathering on flashover performance of nonceramic insulators," IEEE Trans. Dielectr. Electr. Insul., vol. 15, no. 4, pp. 1073-1080, 2008.
-
(2008)
IEEE Trans. Dielectr. Electr. Insul.
, vol.15
, Issue.4
, pp. 1073-1080
-
-
Venkataraman, S.1
Gorur, R.S.2
Mishra, A.P.3
-
6
-
-
85006698808
-
Diagnostics for nonceramic insulators in harsh environments
-
I. Ramirez-Vazquez, R. Hernandez-Corona, and G. Montoya-Tena, "Diagnostics for nonceramic insulators in harsh environments," IEEE Electr. Insul. Mag., vol. 25, no. 6, pp. 28-33, 2009.
-
(2009)
IEEE Electr. Insul. Mag.
, vol.25
, Issue.6
, pp. 28-33
-
-
Ramirez-Vazquez, I.1
Hernandez-Corona, R.2
Montoya-Tena, G.3
-
7
-
-
77249093592
-
Insulator condition analysis for overhead distribution lines using combined wavelet support vector machine (SVM)
-
V. S. Murthy, K. Tarakanath, D. K. Mohanta, and S. Gupta, "Insulator condition analysis for overhead distribution lines using combined wavelet support vector machine (SVM)," IEEE Trans. Dielectr. Electr. Insul., vol. 17, no. 1, pp. 89-99, 2010.
-
(2010)
IEEE Trans. Dielectr. Electr. Insul.
, vol.17
, Issue.1
, pp. 89-99
-
-
Murthy, V.S.1
Tarakanath, K.2
Mohanta, D.K.3
Gupta, S.4
-
8
-
-
0038692444
-
Electromagnetic induction method for detecting and locating flaws on overhead transmission lines
-
M. Komoda, T. Kawashima, M. Minemura, A. Mineyama, M. Aihara, Y. Ebinuma, T. Kanno, and M. Kiuchi, "Electromagnetic induction method for detecting and locating flaws on overhead transmission lines," IEEE Trans. Power Del., vol. 5, no. 3, pp. 1484-490, 1990.
-
(1990)
IEEE Trans. Power Del.
, vol.5
, Issue.3
, pp. 1484-1490
-
-
Komoda, M.1
Kawashima, T.2
Minemura, M.3
Mineyama, A.4
Aihara, M.5
Ebinuma, Y.6
Kanno, T.7
Kiuchi, M.8
-
9
-
-
67349153353
-
A feasibility study on autonomous online conditionmonitoring of high-voltage overhead power lines
-
H. Zangl, T. Bretterklieber, and G. Brasseur, "A feasibility study on autonomous online conditionmonitoring of high-voltage overhead power lines," IEEE Trans. Instrum. Meas., vol. 58, no. 5, pp. 1789-1796, 2009.
-
(2009)
IEEE Trans. Instrum. Meas.
, vol.58
, Issue.5
, pp. 1789-1796
-
-
Zangl, H.1
Bretterklieber, T.2
Brasseur, G.3
-
10
-
-
0842309901
-
Development of health indices for asset condition assessment
-
T. Hjartarson, B. Jesus, D. T. Hughes, and R. M. Godfrey, "Development of health indices for asset condition assessment," in Proc. IEEE Transmission and Distribution Conf. Expo., 2003, vol. 2, pp. 541-44.
-
(2003)
Proc. IEEE Transmission and Distribution Conf. Expo.
, vol.2
, pp. 541-544
-
-
Hjartarson, T.1
Jesus, B.2
Hughes, D.T.3
Godfrey, R.M.4
-
12
-
-
0031121412
-
Reliability centered maintenance for transmission systems
-
M. E. Beehler, "Reliability centered maintenance for transmission systems," IEEE Trans. Power Del., vol. 12, no. 2, pp. 1023-1028, 1997. (Pubitemid 127762408)
-
(1997)
IEEE Transactions on Power Delivery
, vol.12
, Issue.2
, pp. 1023-1028
-
-
Beehler, M.E.1
-
14
-
-
0038154388
-
Applying reliability centered maintenance (RCM) to overhead electric utility distribution systems
-
J. W. Goodfellow, "Applying reliability centered maintenance (RCM) to overhead electric utility distribution systems," in Proc. IEEE PES Summer Meeting, 2000, pp. 566-569.
-
(2000)
Proc. IEEE PES Summer Meeting
, pp. 566-569
-
-
Goodfellow, J.W.1
-
15
-
-
84968856104
-
-
New York, NY, USA: IEEE Press/Wiley
-
W. Li, Risk Assessment of Power Systems: Models, Methods, and Applications. New York, NY, USA: IEEE Press/Wiley, 2005.
-
(2005)
Risk Assessment of Power Systems: Models, Methods, and Applications
-
-
Li, W.1
-
16
-
-
2542531519
-
Failure rate modeling using equipment inspection data
-
R. E. Brown, G. Frimpong, and H. L. Willis, "Failure rate modeling using equipment inspection data," IEEE Trans. Power Syst., vol. 19, no. 2, pp. 782-787, 2004.
-
(2004)
IEEE Trans. Power Syst.
, vol.19
, Issue.2
, pp. 782-787
-
-
Brown, R.E.1
Frimpong, G.2
Willis, H.L.3
-
18
-
-
28744448044
-
Condition Based Risk Management (CBRM) - Enabling asset condition information to be central to corporate decision making
-
156, Eighteenth International Conference and Exhibition on Electricity Distribution, CIRED 2005, Technical Reports - Session 1: Network Components
-
D. Hughes, "Condition based risk management (CBRM)-enabling asset condition information to be central to corporate decision making," in Proc. 18th Int. Conf. Exhib. Electricity Distribution, CIRED 2005, Technical Reports-Session 1: Network Components, Turin, Italy, 2005, pp. 39-43. (Pubitemid 41757950)
-
(2005)
IEE Conference Publication
, vol.1
, Issue.2005
, pp. 39-43
-
-
Hughes, D.1
|