메뉴 건너뛰기




Volumn 60, Issue 4, 2014, Pages 399-401

Evaluation of the Bio-Rad Geenius HIV-1/2 test as a confirmatory assay

Author keywords

Geenius HIV1 2; HIV confirmatory tests; HIV Western blot

Indexed keywords

ARTICLE; CROSS REACTION; ENZYME IMMUNOASSAY; FOLLOW UP; HIV CLIA KIT; HIV TEST; HUMAN IMMUNODEFICIENCY VIRUS 1; HUMAN IMMUNODEFICIENCY VIRUS 2; NONHUMAN; PRIORITY JOURNAL; SCREENING TEST; SENSITIVITY AND SPECIFICITY; SEROCONVERSION; WESTERN BLOTTING; BLOOD; HIV INFECTIONS; HUMAN; HUMAN IMMUNODEFICIENCY VIRUS INFECTION; IMMUNOASSAY; IMMUNOLOGY; PROCEDURES; SEROLOGY; VIROLOGY;

EID: 84902771335     PISSN: 13866532     EISSN: 18735967     Source Type: Journal    
DOI: 10.1016/j.jcv.2014.04.025     Document Type: Article
Times cited : (29)

References (8)
  • 1
    • 84902796848 scopus 로고    scopus 로고
    • Criteria for laboratory testing and diagnosis of human immunodeficiency virus infection; approved guideline
    • Clinical and Laboratory Standards Institute (CLSI)
    • Clinical and Laboratory Standards Institute (CLSI) Criteria for laboratory testing and diagnosis of human immunodeficiency virus infection; approved guideline. CLSI Document M53-A 2011 2011.
    • (2011) CLSI Document M53-A 2011
  • 2
    • 34547113746 scopus 로고    scopus 로고
    • Frequency, causes, and new challenges of intermediate results in Western blot confirmatory testing for antibodies to human immunodeficiency virus
    • Guan M. Frequency, causes, and new challenges of intermediate results in Western blot confirmatory testing for antibodies to human immunodeficiency virus. Clin Vaccine Immunol 2007, 14:649-659.
    • (2007) Clin Vaccine Immunol , vol.14 , pp. 649-659
    • Guan, M.1
  • 3
    • 83155180369 scopus 로고    scopus 로고
    • Establishing the diagnosis of HIV infection: new tests and new algorithm for the United States
    • Branson B.M., Mermin J. Establishing the diagnosis of HIV infection: new tests and new algorithm for the United States. J Clin Virol 2011, 52(Suppl. 1):S3-S4.
    • (2011) J Clin Virol , vol.52 , Issue.SUPPL. 1
    • Branson, B.M.1    Mermin, J.2
  • 4
    • 84890167971 scopus 로고    scopus 로고
    • Comparative evaluation of the Bio-Rad Geenius HIV-1/2 confirmatory assay and the Bio-Rad Multispot HIV-1/2 Rapid test as an alternative differentiation assay for CLSI M53 algorithm-I
    • Malloch L., Kadivar K., Putz J., Levett P.N., Tang J., Hatchette T.F., et al. Comparative evaluation of the Bio-Rad Geenius HIV-1/2 confirmatory assay and the Bio-Rad Multispot HIV-1/2 Rapid test as an alternative differentiation assay for CLSI M53 algorithm-I. J Clin Virol 2013, 58S:e85-e91.
    • (2013) J Clin Virol , vol.58 S
    • Malloch, L.1    Kadivar, K.2    Putz, J.3    Levett, P.N.4    Tang, J.5    Hatchette, T.F.6
  • 7
    • 84890201867 scopus 로고    scopus 로고
    • Evaluation of the Bio-Rad Multispot HIV-1/HIV-2 rapid test as an alternative to Western blot for confirmation of HIV infection
    • Cardenas A.M., Baughan E., Hodinka R.L. Evaluation of the Bio-Rad Multispot HIV-1/HIV-2 rapid test as an alternative to Western blot for confirmation of HIV infection. J Clin Virol 2013, 58S:e97-e103.
    • (2013) J Clin Virol , vol.58 S
    • Cardenas, A.M.1    Baughan, E.2    Hodinka, R.L.3
  • 8
    • 34547113746 scopus 로고    scopus 로고
    • Frequency, causes, and new challenges of indeterminate results in Western blot confirmatory testing for antibodies to human immunodeficiency virus
    • Guan M. Frequency, causes, and new challenges of indeterminate results in Western blot confirmatory testing for antibodies to human immunodeficiency virus. Clin Vaccine Immunol 2007, 14:649-659.
    • (2007) Clin Vaccine Immunol , vol.14 , pp. 649-659
    • Guan, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.