메뉴 건너뛰기




Volumn 17, Issue 2, 2014, Pages 162-168

Evaluation of advancing the standard valve dysfunction by multidetector-row CT

Author keywords

Cineradiography; Echocardiography; Mechanical heart valve; Multidetector row computed tomography; Prosthetic valve dysfunction

Indexed keywords

ADULT; ARTICLE; CINERADIOGRAPHY; CLINICAL ARTICLE; CLINICAL EVALUATION; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; ECHOCARDIOGRAPHY; FEMALE; FIBRINOLYTIC THERAPY; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PARAPROSTHETIC REGURGITATION; PRIORITY JOURNAL; PROSTHETIC VALVE DYSFUNCTION; PROSTHETIC VALVE OBSTRUCTION; RADIATION DOSE; RELIABILITY; SUBPROSTHETIC MASS; SUBPROSTHETIC PANNUS; THROMBUS; TREATMENT FAILURE; AGED; AORTA VALVE; CLINICAL TRIAL; ELECTROCARDIOGRAPHY; HEART VALVE DISEASES; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; MIDDLE AGED; MITRAL VALVE; PROSTHESIS FAILURE; REOPERATION; REPRODUCIBILITY; VERY ELDERLY; YOUNG ADULT;

EID: 84902660996     PISSN: 14347229     EISSN: 16190904     Source Type: Journal    
DOI: 10.1007/s10047-013-0751-z     Document Type: Article
Times cited : (15)

References (20)
  • 3
    • 33747365291 scopus 로고    scopus 로고
    • Leaflet movement of the ATS valve in the aortic position: Unique behavior observed in 19-mm valves
    • Aoyagi S, Arinaga K, Fukunaga S, Tayama E, Kosuga T, Akashi H. Leaflet movement of the ATS valve in the aortic position: unique behavior observed in 19-mm valves. Ann Thorac Surg. 2006;82:853-7.
    • (2006) Ann Thorac Surg , vol.82 , pp. 853-857
    • Aoyagi, S.1    Arinaga, K.2    Fukunaga, S.3    Tayama, E.4    Kosuga, T.5    Akashi, H.6
  • 6
    • 0032213362 scopus 로고    scopus 로고
    • Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: An evaluation of clinical, transthoracic and transesophageal echocardiographic parameters
    • DOI 10.1016/S0735-1097(98)00385-4, PII S0735109798003854
    • Barbetseas J, Nagueh SF, Pitsavos C, Toutouzas PK, Quinones MA, Zoghbi WA. Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: An evaluation of clinical, transthoracic and transesophageal echocardiographic parameter. J Am Coll Cardiol. 1998;32:1410-7. (Pubitemid 28522403)
    • (1998) Journal of the American College of Cardiology , vol.32 , Issue.5 , pp. 1410-1417
    • Barbetseas, J.1    Nagueh, S.F.2    Pitsavos, C.3    Toutouzas, P.K.4    Quinones, M.A.5    Zoghbi, W.A.6
  • 9
    • 59349116098 scopus 로고    scopus 로고
    • Role of MDCT in the evaluation of prosthetic heart valve (Letters)
    • Biteker M, Gündüz S, Özkan M. Role of MDCT in the evaluation of prosthetic heart valve (Letters). Am J Radiol. 2009;192:W77-8.
    • (2009) Am J Radiol , vol.192
    • Biteker, M.1    Gündüz, S.2    Özkan, M.3
  • 10
    • 84873833126 scopus 로고    scopus 로고
    • Evaluation of prosthetic valve obstruction by electrocardiographically- gated multidetector-row computed tomography: Identification of subprosthetic pannus in the aortic position
    • Ueda T, Teshima H, Fukunaga S, Aoyagi S, Tanaka S. Evaluation of prosthetic valve obstruction by electrocardiographically-gated multidetector-row computed tomography: Identification of subprosthetic pannus in the aortic position. Circulation J. 2013;77:418-23.
    • (2013) Circulation J , vol.77 , pp. 418-423
    • Ueda, T.1    Teshima, H.2    Fukunaga, S.3    Aoyagi, S.4    Tanaka, S.5
  • 11
    • 0442323707 scopus 로고    scopus 로고
    • Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation
    • DOI 10.1016/S0003-4975(03)01531-5
    • Teshima H, Hayashida N, Fukunaga S, Tayama E, Kawara T, Aoyagi S, Uchida M. Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation. Ann Thorac Surg. 2004;77:523-6. (Pubitemid 38186504)
    • (2004) Annals of Thoracic Surgery , vol.77 , Issue.2 , pp. 523-526
    • Teshima, H.1    Hayashida, N.2    Fukunaga, S.3    Tayama, E.4    Kawara, T.5    Aoyagi, S.6    Uchida, M.7
  • 12
    • 38149035216 scopus 로고    scopus 로고
    • Prosthetic valve obstruction: Diagnostic usefulness of cineradiography and multidetector-row computed tomography
    • Aoyagi S, Fukunaga S, Arinaga K, Shojima T, Ueda T. Prosthetic valve obstruction: diagnostic usefulness of cineradiography and multidetector-row computed tomography. Thorac Cardiovasc Surg. 2007;55:517-9.
    • (2007) Thorac Cardiovasc Surg , vol.55 , pp. 517-519
    • Aoyagi, S.1    Fukunaga, S.2    Arinaga, K.3    Shojima, T.4    Ueda, T.5
  • 15
    • 67049146759 scopus 로고    scopus 로고
    • Left atrial appendage thrombi in stroke patients: Detection with two-phase cardiac CT angiography versus transesophageal echocardiography
    • Hur J, Kim YJ, Lee H-J, Ha J-W, Heo JH, Choi E-Y, et al. Left atrial appendage thrombi in stroke patients: Detection with two-phase cardiac CT angiography versus transesophageal echocardiography. Radiology. 2009;251:683-90.
    • (2009) Radiology , vol.251 , pp. 683-690
    • Hur, J.1    Kim, Y.J.2    Lee, H.-J.3    Ha, J.-W.4    Heo, J.H.5    Choi, E.-Y.6
  • 16
    • 67949111270 scopus 로고    scopus 로고
    • Contribution of the amount of contrast media used in pulmonary CT angiography to assess the diagnostic value of CT venography; comparison of 100 and 150 ml of contrast media
    • Calisir C, Yavas US, Kebapci M, Korkmaz A, Ozkan R. Contribution of the amount of contrast media used in pulmonary CT angiography to assess the diagnostic value of CT venography; comparison of 100 and 150 ml of contrast media. Clin Radiol. 2009;64:912-7.
    • (2009) Clin Radiol , vol.64 , pp. 912-917
    • Calisir, C.1    Yavas, U.S.2    Kebapci, M.3    Korkmaz, A.4    Ozkan, R.5
  • 18
    • 0033989257 scopus 로고    scopus 로고
    • Combined CT venography and pulmonary angiography in suspected thromboembolic disease: Diagnostic accuracy for deep venous evaluation
    • Loud PA, Katz DS, Klippenstein DL, Shah RD, Grossman ZD. Combined CT venography and pulmonary angiography in suspected thromboembolic disease: diagnostic accuracy for deep venous evaluation. Am J Radiol. 2000;174:61-5. (Pubitemid 30030209)
    • (2000) American Journal of Roentgenology , vol.174 , Issue.1 , pp. 61-65
    • Loud, P.A.1    Katz, D.S.2    Klippenstein, D.L.3    Shah, R.D.4    Grossman, Z.D.5
  • 19
    • 75649112666 scopus 로고    scopus 로고
    • Mechanical mitral valve thrombosis and giant left atrial thrombus: Comparison of transesophageal echocardiography and 64-slice multidetector computed tomography
    • Gündüz S, Ozkan M, Biteker M, Güneysu T. Mechanical mitral valve thrombosis and giant left atrial thrombus: comparison of transesophageal echocardiography and 64-slice multidetector computed tomography. Arch Turk Soc Cardiol. 2009;37:483-7.
    • (2009) Arch Turk Soc Cardiol , vol.37 , pp. 483-487
    • Gündüz, S.1    Ozkan, M.2    Biteker, M.3    Güneysu, T.4
  • 20
    • 33845621446 scopus 로고    scopus 로고
    • Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom
    • DOI 10.1148/radiol.2421052066
    • Bimbaum BA, Hindman N, Lee J, Babb JS. Multi-detector row CT attenuation measurements: assessment of intra- and interscanner variability with an anthropomorphic body CT phantom. Radiology. 2007;242:109-19. (Pubitemid 44956015)
    • (2007) Radiology , vol.242 , Issue.1 , pp. 109-119
    • Birnbaum, B.A.1    Hindman, N.2    Lee, J.3    Babb, J.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.