1
-
-
84902664091
-
-
Axelsson B et al 2013 Cardiac effects of non-adrenergic inotropic drugs: clinical and experimental studies 1-17 Doctorial Dissertation Umeå University, SE, paper IV (Systolic and diastolic effects of milrinone and levosimendan in porcine post-ischemic myocardial dysfunction)
-
(2013)
Doctorial Dissertation
, pp. 1-17
-
-
Axelsson, B.1
-
2
-
-
0036239613
-
Quantitative near infrared spectroscopy measurement of cerebral hemodynamics in newborn piglets
-
Brown D W, Picot P A, Naeini J G, Springett R, Delpy D T and Lee T Y 2002 Quantitative near infrared spectroscopy measurement of cerebral hemodynamics in newborn piglets Pediatr. Res. 51 564-70 (Pubitemid 34453571)
-
(2002)
Pediatric Research
, vol.51
, Issue.5
, pp. 564-570
-
-
Brown, D.W.1
Picot, P.A.2
Naeini, J.G.3
Springett, R.4
Delpy, D.T.5
Lee, T.-Y.6
-
3
-
-
79959353069
-
Continuous monitoring of absolute cerebral blood flow by near-infrared spectroscopy during global and focal temporary vessel occlusion
-
10.1152/japplphysiol.01458.2010
-
Cooper J A et al 2011 Continuous monitoring of absolute cerebral blood flow by near-infrared spectroscopy during global and focal temporary vessel occlusion J. Appl. Physiol. 110 1691-8
-
(2011)
J. Appl. Physiol.
, vol.110
, pp. 1691-1698
-
-
Cooper, J.A.1
-
4
-
-
84859111411
-
Impact of extracranial contamination on regional cerebral oxygen saturation: A comparison of three cerebral oximetry technologies
-
10.1097/ALN.0b013e31824c00d7
-
Davie S N and Grocott H P 2012 Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies Anesthesiology 116 834-40
-
(2012)
Anesthesiology
, vol.116
, pp. 834-840
-
-
Davie, S.N.1
Grocott, H.P.2
-
5
-
-
0024206831
-
Estimation of optical pathlength through tissue from direct time of flight measurement
-
Delpy D T, Cope M, van der Zee P, Arridge S, Wray S and Wyatt J 1988 Estimation of optical pathlength through tissue from direct time of flight measurement Phys. Med. Biol. 33 1433-42 (Pubitemid 19021438)
-
(1988)
Physics in Medicine and Biology
, vol.33
, Issue.12
, pp. 1433-1442
-
-
Delpy, D.T.1
Cope, M.2
Van Der Zee, P.3
Arridge, S.4
Wray, S.5
Wyatt, J.6
-
6
-
-
79955711487
-
Quantitative measurement of cerebral blood flow in a juvenile porcine model by depth-resolved near-infrared spectroscopy
-
10.1117/1.3449579 037014
-
Elliott J T, Diop M, Tichauer K M, Lee T Y and St Lawrence K 2010 Quantitative measurement of cerebral blood flow in a juvenile porcine model by depth-resolved near-infrared spectroscopy J. Biomed. Opt. 15 037014
-
(2010)
J. Biomed. Opt.
, vol.15
-
-
Elliott, J.T.1
Diop, M.2
Tichauer, K.M.3
Lee, T.Y.4
St Lawrence, K.5
-
7
-
-
0028598339
-
Quantification of adult cerebral hemodynamics by near-infrared spectroscopy
-
Elwell C E, Cope M, Edwards A D, Wyatt J S, Delpy D T and Reynolds E O 1994 Quantification of adult cerebral hemodynamics by near-infrared spectroscopy J. Appl. Physiol. 77 2753-60
-
(1994)
J. Appl. Physiol.
, vol.77
, pp. 2753-2760
-
-
Elwell, C.E.1
Cope, M.2
Edwards, A.D.3
Wyatt, J.S.4
Delpy, D.T.5
Reynolds, E.O.6
-
8
-
-
77956494842
-
Noninvasive cerebral oximetry: Is there light at the end of the tunnel?
-
10.1097/ACO.0b013e32833e1536 0952-7907
-
Highton D, Elwell C and Smith M 2010 Noninvasive cerebral oximetry: is there light at the end of the tunnel? Curr. Opin. Anaesthesiol. 23 576-81
-
(2010)
Curr. Opin. Anaesthesiol.
, vol.23
, pp. 576-581
-
-
Highton, D.1
Elwell, C.2
Smith, M.3
-
9
-
-
84865830854
-
Tissue oximetry: A comparison of mean values of regional tissue saturation, reproducibility and dynamic range of four NIRS-instruments on the human forearm
-
10.1364/BOE.2.003047
-
Hyttel-Sorensen S, Sorensen L C, Riera J and Greisen G 2011 Tissue oximetry: a comparison of mean values of regional tissue saturation, reproducibility and dynamic range of four NIRS-instruments on the human forearm Biomed. Opt. Express 2 3047-57
-
(2011)
Biomed. Opt. Express
, vol.2
, pp. 3047-3057
-
-
Hyttel-Sorensen, S.1
Sorensen, L.C.2
Riera, J.3
Greisen, G.4
-
10
-
-
0017571334
-
Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
-
10.1126/science.929199
-
Joöbsis F F 1977 Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters Science 198 1264-7
-
(1977)
Science
, vol.198
, pp. 1264-1267
-
-
Joöbsis, F.F.1
-
11
-
-
51649091671
-
Brain oxymetry in the operating room: Current status and future directions with particular regard to cytochrome oxidase
-
10.1117/1.2940583 033001
-
Kakihana Y, Matsunaga A, Yasuda T, Imabayashi T, Kanmura Y and Tamura M 2008 Brain oxymetry in the operating room: current status and future directions with particular regard to cytochrome oxidase J. Biomed. Opt. 13 033001
-
(2008)
J. Biomed. Opt.
, vol.13
-
-
Kakihana, Y.1
Matsunaga, A.2
Yasuda, T.3
Imabayashi, T.4
Kanmura, Y.5
Tamura, M.6
-
13
-
-
77953614706
-
Noninvasive measurement of cerebral blood flow and blood oxygenation using near-infrared and diffuse correlation spectroscopies in critically brain-injured adults
-
10.1007/s12028-009-9305-x
-
Kim M N et al 2010 Noninvasive measurement of cerebral blood flow and blood oxygenation using near-infrared and diffuse correlation spectroscopies in critically brain-injured adults Neurocrit. Care 12 173-80
-
(2010)
Neurocrit. Care
, vol.12
, pp. 173-180
-
-
Kim, M.N.1
-
14
-
-
84867865947
-
Transscleral optical spectroscopy of uveal melanoma in enucleated human eyes
-
10.1167/iovs.12-9840 0146-0404
-
Krohn J, Svenmarker P, Xu C T, Mørk S J and Andersson-Engels S 2012 Transscleral optical spectroscopy of uveal melanoma in enucleated human eyes Invest. Ophthalmol. Vis. Sci. 53 5379-85
-
(2012)
Invest. Ophthalmol. Vis. Sci.
, vol.53
, pp. 5379-5385
-
-
Krohn, J.1
Svenmarker, P.2
Xu, C.T.3
Mørk, S.J.4
Andersson-Engels, S.5
-
15
-
-
0027282729
-
Volume blood flow measurements with a transit time flowmeter: An in vivo and in vitro variability and validation study
-
Lundell A, Bergqvist D, Mattsson E and Nilsson B 1993 Volume blood flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation study Clin. Physiol. 13 547-57 (Pubitemid 23262167)
-
(1993)
Clinical Physiology
, vol.13
, Issue.5
, pp. 547-557
-
-
Lundell, A.1
Bergqvist, D.2
Mattsson, E.3
Nilsson, B.4
-
16
-
-
84872708775
-
Relation between mixed venous oxygen saturation and cerebral oxygen saturation measured by absolute and relative near-infrared spectroscopy during off-pump coronary artery bypass grafting
-
10.1093/bja/aes375
-
Moerman A, Vandenplas G, Bové T, Wouters P F and De Hert S G 2013 Relation between mixed venous oxygen saturation and cerebral oxygen saturation measured by absolute and relative near-infrared spectroscopy during off-pump coronary artery bypass grafting Br. J. Anaesth. 110 258-65
-
(2013)
Br. J. Anaesth.
, vol.110
, pp. 258-265
-
-
Moerman, A.1
Vandenplas, G.2
Bové, T.3
Wouters, P.F.4
De Hert, S.G.5
-
17
-
-
34748889901
-
Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: A comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials
-
DOI 10.1097/01.anes.0000281894.69422.ff, PII 0000054220071000000010
-
Moritz S, Kasprzak P, Arlt M, Taeger K and Metz C 2007 Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials Anesthesiology 107 563-9 (Pubitemid 47480561)
-
(2007)
Anesthesiology
, vol.107
, Issue.4
, pp. 563-569
-
-
Moritz, S.1
Kasprzak, P.2
Arlt, M.3
Taeger, K.4
Metz, C.5
-
18
-
-
33847686685
-
Monitoring brain oxygen saturation during coronary bypass surgery: A randomized, prospective study
-
DOI 10.1213/01.ane.0000246814.29362.f4, PII 0000053920070100000011
-
Murkin J M et al 2007 Monitoring brain oxygen saturation during coronary bypass surgery: a randomized, prospective study Anesth. Analg. 104 51-58 (Pubitemid 46360419)
-
(2007)
Anesthesia and Analgesia
, vol.104
, Issue.1
, pp. 51-58
-
-
Murkin, J.M.1
Adams, S.J.2
Novick, R.J.3
Quantz, M.4
Bainbridge, D.5
Iglesias, I.6
Cleland, A.7
Schaefer, B.8
Irwin, B.9
Fox, S.10
-
19
-
-
0036301795
-
Preserved myocardial energetics in acute ischemic left ventricular failure - Studies in an experimental pig model
-
DOI 10.1016/S1010-7940(02)00201-4, PII S1010794002002014
-
Nordhaug D, Steensrud T, Korvald C, Aghajani E and Myrmel T 2002 Preserved myocardial energetics in acute ischemic left ventricular failure - studies in an experimental pig model Eur. J. Cardiothorac. Surg. 22 135-42 (Pubitemid 34743726)
-
(2002)
European Journal of Cardio-thoracic Surgery
, vol.22
, Issue.1
, pp. 135-142
-
-
Nordhaug, D.1
Steensrud, T.2
Korvald, C.3
Aghajani, E.4
Myrmel, T.5
-
20
-
-
84871946431
-
Validation of a stand-alone near-infrared spectroscopy system for monitoring cerebral autoregulation during cardiac surgery
-
10.1213/ANE.0b013e318271fb10
-
Ono M, Zheng Y, Joshi B, Sigl J C and Hogue C W 2013 Validation of a stand-alone near-infrared spectroscopy system for monitoring cerebral autoregulation during cardiac surgery Anesth. Analg. 116 198-204
-
(2013)
Anesth. Analg.
, vol.116
, pp. 198-204
-
-
Ono, M.1
Zheng, Y.2
Joshi, B.3
Sigl, J.C.4
Hogue, C.W.5
-
21
-
-
84855261151
-
Is near-infrared spectroscopy a reliable method to evaluate clamping ischemia during carotid surgery?
-
156975
-
Pedrini L et al 2012 Is near-infrared spectroscopy a reliable method to evaluate clamping ischemia during carotid surgery? Stroke Res. Treat 2012 156975
-
(2012)
Stroke Res. Treat
, vol.2012
-
-
Pedrini, L.1
-
22
-
-
78650560145
-
Near-infrared spectroscopy: A methodology-focused review
-
10.1016/j.siny.2010.05.003
-
Pellicer A and Bravo Mdel C 2011 Near-infrared spectroscopy: a methodology-focused review Semin. Fetal Neonatal Med. 16 42-49
-
(2011)
Semin. Fetal Neonatal Med.
, vol.16
, pp. 42-49
-
-
Pellicer, A.1
Bravo Mdel, C.2
-
23
-
-
1842557501
-
Practicality of wavelength selection to improve signal-to-noise ratio in near-infrared spectroscopy
-
DOI 10.1016/j.neuroimage.2003.12.017, PII S1053811903007833
-
Sato H, Kiguchi M, Kawaguchi F and Maki A 2004 Practicality of wavelength selection to improve signal-to-noise ratio in near-infrared spectroscopy Neuroimage 21 1554-62 (Pubitemid 38446579)
-
(2004)
NeuroImage
, vol.21
, Issue.4
, pp. 1554-1562
-
-
Sato, H.1
Kiguchi, M.2
Kawaguchi, F.3
Maki, A.4
-
24
-
-
62849105341
-
Changes in cerebral blood flow after acetazolamide: An experimental study comparing near-infrared spectroscopy and SPECT
-
10.1111/j.1468-1331.2008.02398.x
-
Schytz H W, Wienecke T, Jensen L T, Selb J, Boas D A and Ashina M 2009 Changes in cerebral blood flow after acetazolamide: an experimental study comparing near-infrared spectroscopy and SPECT Eur. J. Neurol. 16 461-7
-
(2009)
Eur. J. Neurol.
, vol.16
, pp. 461-467
-
-
Schytz, H.W.1
Wienecke, T.2
Jensen, L.T.3
Selb, J.4
Boas, D.A.5
Ashina, M.6
-
25
-
-
70749117420
-
Portable optical tissue flow oximeter based on diffuse correlation spectroscopy
-
10.1364/OL.34.003556
-
Shang Y, Zhao Y, Cheng R, Dong L, Irwin D and Yu G 2009 Portable optical tissue flow oximeter based on diffuse correlation spectroscopy Opt. Lett. 34 3556-8
-
(2009)
Opt. Lett.
, vol.34
, pp. 3556-3558
-
-
Shang, Y.1
Zhao, Y.2
Cheng, R.3
Dong, L.4
Irwin, D.5
Yu, G.6
-
26
-
-
84870173355
-
The sensibility and specificity of cerebral oximetry, measured by INVOS - 4100, in patients undergoing carotid endarterectomy compared with awake testing
-
0375-9393
-
Stilo F et al 2012 The sensibility and specificity of cerebral oximetry, measured by INVOS - 4100, in patients undergoing carotid endarterectomy compared with awake testing Minerva Anestesiol. 78 1126-35
-
(2012)
Minerva Anestesiol.
, vol.78
, pp. 1126-1135
-
-
Stilo, F.1
-
27
-
-
84857328314
-
Validation of frontal near-infrared spectroscopy as noninvasive bedside monitoring for regional cerebral blood flow in brain-injured patients
-
10.3171/2011.12.FOCUS11280 1092-0684
-
Taussky P et al 2012 Validation of frontal near-infrared spectroscopy as noninvasive bedside monitoring for regional cerebral blood flow in brain-injured patients Neurosurg. Focus 32 E2
-
(2012)
Neurosurg. Focus
, vol.32
, pp. 2
-
-
Taussky, P.1
-
28
-
-
33645816340
-
Near-infrared spectroscopy measurements of cerebral blood flow and oxygen consumption following hypoxia-ischemia in newborn piglets
-
DOI 10.1152/japplphysiol.00830.2005
-
Tichauer K M, Brown D W, Hadway J, Lee T Y and St Lawrence K 2006 Near-infrared spectroscopy measurements of cerebral blood flow and oxygen consumption following hypoxia-ischemia in newborn piglets J. Appl. Physiol. 100 850-7 (Pubitemid 43671540)
-
(2006)
Journal of Applied Physiology
, vol.100
, Issue.3
, pp. 850-857
-
-
Tichauer, K.M.1
Brown, D.W.2
Hadway, J.3
Lee, T.-Y.4
St. Lawrence, K.5
-
29
-
-
84865782606
-
Correlation between the arterial pulse wave of the cerebral microcirculation and CBF during breath holding and hyperventilation in human
-
10.1016/j.clinph.2012.03.017 0987-7053
-
Viola S, Viola P, Litterio P, Buongarzone M P and Fiorelli L 2012 Correlation between the arterial pulse wave of the cerebral microcirculation and CBF during breath holding and hyperventilation in human Neurophysiol. Clin. 123 1931-6
-
(2012)
Neurophysiol. Clin.
, vol.123
, pp. 1931-1936
-
-
Viola, S.1
Viola, P.2
Litterio, P.3
Buongarzone, M.P.4
Fiorelli, L.5
-
30
-
-
0033870575
-
Coupling of cerebral blood flow and oxygen metabolism in infant pigs during selective brain hypothermia
-
Walter B, Bauer R, Kuhnen G, Fritz H and Zwiener U 2000 Coupling of cerebral blood flow and oxygen metabolism in infant pigs during selective brain hypothermia J. Cereb. Blood Flow Metab. 20 1215-24 (Pubitemid 30636757)
-
(2000)
Journal of Cerebral Blood Flow and Metabolism
, vol.20
, Issue.8
, pp. 1215-1224
-
-
Walter, B.1
Bauer, R.2
Kuhnen, G.3
Fritz, H.4
Zwiener, U.5
-
31
-
-
0033775089
-
Arterial and venous contributions to near-infrared cerebral oximetry
-
10.1097/00000542-200010000-00012
-
Watzman H M, Kurth C D, Montenegro L M, Rome J, Steven J M and Nicolson S C 2000 Arterial and venous contributions to near-infrared cerebral oximetry Anesthesiology 93 947-53
-
(2000)
Anesthesiology
, vol.93
, pp. 947-953
-
-
Watzman, H.M.1
Kurth, C.D.2
Montenegro, L.M.3
Rome, J.4
Steven, J.M.5
Nicolson, S.C.6
-
32
-
-
84894198790
-
Cardiorespiratory coherence analysis of abnormal heart rate responses during deep breathing
-
Wiklund U, Kadkhodaee A and Andersson K 2013 Cardiorespiratory coherence analysis of abnormal heart rate responses during deep breathing Proc. Comput. Cardiol. 40 109-12
-
(2013)
Proc. Comput. Cardiol.
, vol.40
, pp. 109-112
-
-
Wiklund, U.1
Kadkhodaee, A.2
Andersson, K.3
|