메뉴 건너뛰기




Volumn , Issue , 2012, Pages 251-263

Coatings for cardiovascular devices: Extracorporeal circuits

Author keywords

Biomembrane mimicry; Cardiopulmonary bypass; End point attached heparin; Heparin surface coating; Left heart bypass; Mechanical circulatory support; Phosphorylcholine; Polymeric phospholipids; Right left ventricular assist devices; Shunts

Indexed keywords


EID: 84902615015     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-1-84569-568-2.50008-4     Document Type: Chapter
Times cited : (3)

References (36)
  • 1
    • 0043009764 scopus 로고    scopus 로고
    • From the magic mountain to rocket science
    • von Segesser L.K. From the magic mountain to rocket science. Interact Cardiovasc Surg 2003, 2:217-218.
    • (2003) Interact Cardiovasc Surg , vol.2 , pp. 217-218
    • von Segesser, L.K.1
  • 2
    • 78651036121 scopus 로고
    • Application of the mechanical heart and lung apparatus to cardiac surgery
    • Gibbon J.H. Application of the mechanical heart and lung apparatus to cardiac surgery. Minn Med 1954, 37:171-185.
    • (1954) Minn Med , vol.37 , pp. 171-185
    • Gibbon, J.H.1
  • 3
    • 0000983222 scopus 로고
    • The thromboplastic action of cephalin
    • Mc Lean J. The thromboplastic action of cephalin. Am J Physiol 1916, 41:250-257.
    • (1916) Am J Physiol , vol.41 , pp. 250-257
    • Mc, L.J.1
  • 5
    • 37049246701 scopus 로고
    • Heparin bonding on colloidal graphite surfaces
    • Gott V.L., Whiffen J.D., Dutton R.C. Heparin bonding on colloidal graphite surfaces. Science 1963, 142:1297-1298.
    • (1963) Science , vol.142 , pp. 1297-1298
    • Gott, V.L.1    Whiffen, J.D.2    Dutton, R.C.3
  • 7
  • 9
    • 0027751619 scopus 로고
    • Improved distal circulatory support for repair of descending thoracic aortic aneurysms
    • von Segesser L.K., Killer I., Jenni R., Lutz U., Turina M.I. Improved distal circulatory support for repair of descending thoracic aortic aneurysms. Ann Thorac Surg 1993, 56:1373-1380.
    • (1993) Ann Thorac Surg , vol.56 , pp. 1373-1380
    • von Segesser, L.K.1    Killer, I.2    Jenni, R.3    Lutz, U.4    Turina, M.I.5
  • 10
    • 0032709809 scopus 로고    scopus 로고
    • Cardiopulmonary support and extracorporeal membrane oxygenation for cardiac assist
    • von Segesser L.K. Cardiopulmonary support and extracorporeal membrane oxygenation for cardiac assist. Ann Thorac Surg 1999, 68:672-677.
    • (1999) Ann Thorac Surg , vol.68 , pp. 672-677
    • von Segesser, L.K.1
  • 12
    • 0025656310 scopus 로고
    • Reduced blood loss and transfusion requirements with low systemic heparinization: preliminary clinical results in coronary artery revascularization
    • von Segesser L.K., Weiss B.M., Garcia E., Gallino A., Turina M.I.I. Reduced blood loss and transfusion requirements with low systemic heparinization: preliminary clinical results in coronary artery revascularization. Eur J Cardiothorac Surg 1990, 4:639-643.
    • (1990) Eur J Cardiothorac Surg , vol.4 , pp. 639-643
    • von Segesser, L.K.1    Weiss, B.M.2    Garcia, E.3    Gallino, A.4    Turina, M.I.I.5
  • 13
    • 0035130414 scopus 로고    scopus 로고
    • Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operation
    • Ovrum E., Tangen G., Oystese R., Ringdal M.A., Istad R. Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operation. J Thorac Cardiovasc Surg 2001, 121:324-330.
    • (2001) J Thorac Cardiovasc Surg , vol.121 , pp. 324-330
    • Ovrum, E.1    Tangen, G.2    Oystese, R.3    Ringdal, M.A.4    Istad, R.5
  • 14
    • 0035130487 scopus 로고    scopus 로고
    • Safety and efficacy of heparin-bonded surfaces in cardiopulmonary bypass
    • von Segesser L.K. Safety and efficacy of heparin-bonded surfaces in cardiopulmonary bypass. J Thorac Cardiovasc Surg 2001, 121:200-201.
    • (2001) J Thorac Cardiovasc Surg , vol.121 , pp. 200-201
    • von Segesser, L.K.1
  • 15
    • 4544281052 scopus 로고    scopus 로고
    • Biostability of Thoralon left ventricular-assist device blood pumping sacs after long-term clinical use
    • Babu R., Gill R., Farrar D. Biostability of Thoralon left ventricular-assist device blood pumping sacs after long-term clinical use. ASAIO J 2004, 50:479-484.
    • (2004) ASAIO J , vol.50 , pp. 479-484
    • Babu, R.1    Gill, R.2    Farrar, D.3
  • 17
    • 0027530009 scopus 로고
    • Coagulation patterns in bovine left-heart bypass with phospholipids versus heparin coating
    • von Segesser L.K., Olah A., Leskosek B., Turina M. Coagulation patterns in bovine left-heart bypass with phospholipids versus heparin coating. ASAIO J 1993, 39:43-46.
    • (1993) ASAIO J , vol.39 , pp. 43-46
    • von Segesser, L.K.1    Olah, A.2    Leskosek, B.3    Turina, M.4
  • 18
    • 0344925046 scopus 로고    scopus 로고
    • Physiological coagulation can be maintained in extracorporeal circulation by means of shed blood separation and coating
    • Albes J.M., Stöhr I.M., Kaluza M., Siegemund A., Schmidt D., Vollandt R., Wahlers T. Physiological coagulation can be maintained in extracorporeal circulation by means of shed blood separation and coating. J Thorac Cardiovasc Surg 2003, 126:1504-1512.
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 1504-1512
    • Albes, J.M.1    Stöhr, I.M.2    Kaluza, M.3    Siegemund, A.4    Schmidt, D.5    Vollandt, R.6    Wahlers, T.7
  • 19
    • 0025976561 scopus 로고
    • Physical and blood contacting characteristics of propyl sulphonate grafted Biomer
    • Okkema A.Z., Yu X.-H., Cooper S.L. Physical and blood contacting characteristics of propyl sulphonate grafted Biomer. Biomaterials 1991, 12:3-12.
    • (1991) Biomaterials , vol.12 , pp. 3-12
    • Okkema, A.Z.1    Yu, X.-H.2    Cooper, S.L.3
  • 20
    • 0024634593 scopus 로고
    • Properties and biological interactions of polyurethane aniomers: effect of sulfonate incorporation
    • Grasel T.G., Cooper S.L. Properties and biological interactions of polyurethane aniomers: effect of sulfonate incorporation. J Biomed Mater Res 1989, 311-338.
    • (1989) J Biomed Mater Res , pp. 311-338
    • Grasel, T.G.1    Cooper, S.L.2
  • 21
    • 0022044622 scopus 로고
    • Polyether-urethane ionomers: surface property/ex vivo blood compatibility relationships
    • Lelah M.D., Pierce J.A., Lambrecht L.K., Cooper S.L. Polyether-urethane ionomers: surface property/ex vivo blood compatibility relationships. J Colloid Interface Sci 1985, 104:422-439.
    • (1985) J Colloid Interface Sci , vol.104 , pp. 422-439
    • Lelah, M.D.1    Pierce, J.A.2    Lambrecht, L.K.3    Cooper, S.L.4
  • 23
    • 1942436754 scopus 로고    scopus 로고
    • A New Poly(2-methoxyethylacrylate-coated CPB circuit possesses superior platelet preservation and inflammatory suppression efficacy
    • Ikuta T., Fujii H., Shibata T., Hattori K., Hirai H., Kumano H., Suehiro S. A New Poly(2-methoxyethylacrylate-coated CPB circuit possesses superior platelet preservation and inflammatory suppression efficacy. Ann Thorac Surg 2004, 77:1678-1683.
    • (2004) Ann Thorac Surg , vol.77 , pp. 1678-1683
    • Ikuta, T.1    Fujii, H.2    Shibata, T.3    Hattori, K.4    Hirai, H.5    Kumano, H.6    Suehiro, S.7
  • 24
    • 18844434720 scopus 로고    scopus 로고
    • Evaluation of a new condensed extra-corporeal circuit for cardiac surgery: a prospective randomized clinical pilot study
    • Fransen E.J., Ganushchak Y.M., Vijay V., de Jong D.S., Buurman W.A., Maessen J.G. Evaluation of a new condensed extra-corporeal circuit for cardiac surgery: a prospective randomized clinical pilot study. Perfusion 2005, 20:91-99.
    • (2005) Perfusion , vol.20 , pp. 91-99
    • Fransen, E.J.1    Ganushchak, Y.M.2    Vijay, V.3    de Jong, D.S.4    Buurman, W.A.5    Maessen, J.G.6
  • 25
    • 0036147152 scopus 로고    scopus 로고
    • Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass
    • DeSomer F., Van B.Y., Caes F., Francois K., Arnout J., Bossuyt X., Taeymans Y., Van N.G. Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass. Perfusion 2002 Jan, 17(1):39-44.
    • (2002) Perfusion , vol.17 , Issue.1 , pp. 39-44
    • DeSomer, F.1    Van, B.Y.2    Caes, F.3    Francois, K.4    Arnout, J.5    Bossuyt, X.6    Taeymans, Y.7    Van, N.G.8
  • 26
    • 0034332701 scopus 로고    scopus 로고
    • Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface
    • De Somer F., Francois K., van Oeveren W., Poelaert J., De Wolf D., Ebels T., Van Nooten G. Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface. Eur J Cardiothorac Surg 2000 Nov, 18(5):602-606.
    • (2000) Eur J Cardiothorac Surg , vol.18 , Issue.5 , pp. 602-606
    • De Somer, F.1    Francois, K.2    van Oeveren, W.3    Poelaert, J.4    De Wolf, D.5    Ebels, T.6    Van Nooten, G.7
  • 27
    • 0025883388 scopus 로고
    • Perfusion without systemic heparinization for rewarming in accidental hypothermia
    • von Segesser L.K., Garcia E., Turina M. Perfusion without systemic heparinization for rewarming in accidental hypothermia. Ann Thorac Surg 1991, 52:560-561.
    • (1991) Ann Thorac Surg , vol.52 , pp. 560-561
    • von Segesser, L.K.1    Garcia, E.2    Turina, M.3
  • 28
    • 0030039260 scopus 로고    scopus 로고
    • Heparin-bonded surfaces in extracorporeal membrane oxygenation for cardiac support
    • von Segesser L. Heparin-bonded surfaces in extracorporeal membrane oxygenation for cardiac support. Ann Thorac Surg 1996, 61(1):330-335.
    • (1996) Ann Thorac Surg , vol.61 , Issue.1 , pp. 330-335
    • von Segesser, L.1
  • 29
    • 0036770386 scopus 로고    scopus 로고
    • Closed, phosphorylcholine-coated circuit and reduction of systemic heparinization for cardiopulmonary bypass: the intra-operative ECMO concept
    • Ranucci M., Pazzaglia A., Isgro G., Cazzaniga A., Ditta A., Boncilli A., Cotza M., Carboni G., Brozzi S., Bonifazi C. Closed, phosphorylcholine-coated circuit and reduction of systemic heparinization for cardiopulmonary bypass: the intra-operative ECMO concept. Int J Artif Organs 2002 Sep, 25(9):875-881.
    • (2002) Int J Artif Organs , vol.25 , Issue.9 , pp. 875-881
    • Ranucci, M.1    Pazzaglia, A.2    Isgro, G.3    Cazzaniga, A.4    Ditta, A.5    Boncilli, A.6    Cotza, M.7    Carboni, G.8    Brozzi, S.9    Bonifazi, C.10
  • 36
    • 49149112602 scopus 로고    scopus 로고
    • Routine use of self-expanding venous cannulas for cardiopulmonary bypass: benefits and pitfalls in 100 consecutive cases
    • von Segesser L.K., Ferrari E., Delay D., Maunz O., Horisberger J., Tozzi P. Routine use of self-expanding venous cannulas for cardiopulmonary bypass: benefits and pitfalls in 100 consecutive cases. Eur J Cardiothorac Surg 2008, 34:635-640.
    • (2008) Eur J Cardiothorac Surg , vol.34 , pp. 635-640
    • von Segesser, L.K.1    Ferrari, E.2    Delay, D.3    Maunz, O.4    Horisberger, J.5    Tozzi, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.