메뉴 건너뛰기




Volumn , Issue , 2014, Pages 1-5

DC series arc generation, characteristic and modelling with arc demonstrator and shaking table

Author keywords

Arc generation; Arc modelling; DC distribution system; DC series arc; Shaking table

Indexed keywords

AUTOMOBILE ELECTRONIC EQUIPMENT; DAMAGE DETECTION; ELECTRIC ARCS; ELECTRIC LOAD DISTRIBUTION; ELECTRIC POWER SYSTEM PROTECTION; ELECTRONICS ENGINEERING; SHIPS; VIBRATIONS (MECHANICAL);

EID: 84902583694     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (13)

References (13)
  • 1
    • 84870359635 scopus 로고    scopus 로고
    • Arc Fault Model of Conductance. Application to the UL1699 Tests Modeling
    • in, 2011 IEEE 57th Holm Conference on
    • J. Andrea, P. Schweitzer, and J. Martel, "Arc Fault Model of Conductance. Application to the UL1699 Tests Modeling," in Electrical Contacts (Holm), 2011 IEEE 57th Holm Conference on, 2011, pp. 1-6.
    • (2011) Electrical Contacts (Holm) , pp. 1-6
    • Andrea, J.1    Schweitzer, P.2    Martel, J.3
  • 2
    • 85072451926 scopus 로고    scopus 로고
    • A Survey on Arc Fault Detection and Wire Fault Location for Aircraft Wiring Systems
    • G. Liu, Cao, Y., Liu, Y., and Liu, Z., "A Survey on Arc Fault Detection and Wire Fault Location for Aircraft Wiring Systems," 2008.
    • (2008)
    • Liu, G.1    Cao, Y.2    Liu, Y.3    Liu, Z.4
  • 3
    • 78650873809 scopus 로고    scopus 로고
    • Improved Fault Analysis Method Based on a New Arc Resistance Formula
    • V. V. Terzija, R. Ciric, and H. Nouri, "Improved Fault Analysis Method Based on a New Arc Resistance Formula," Power Delivery, IEEE Transactions on, vol. 26, pp. 120-126, 2011.
    • (2011) Power Delivery, IEEE Transactions on , vol.26 , pp. 120-126
    • Terzija, V.V.1    Ciric, R.2    Nouri, H.3
  • 4
    • 84860176009 scopus 로고    scopus 로고
    • The detection of DC arc fault: Experimental study and fault recognition
    • in, 2012 Twenty-Seventh Annual IEEE
    • Y. Xiu, L. Herrera, H. Yi, and W. Jin, "The detection of DC arc fault: Experimental study and fault recognition," in Applied Power Electronics Conference and Exposition (APEC), 2012 Twenty-Seventh Annual IEEE, 2012, pp. 1720-1727.
    • (2012) Applied Power Electronics Conference and Exposition (APEC) , pp. 1720-1727
    • Xiu, Y.1    Herrera, L.2    Yi, H.3    Jin, W.4
  • 5
    • 84874248038 scopus 로고    scopus 로고
    • Study on characteristics and detection of DC arc fault in power electronics system
    • in, 2012 International Conference on
    • Y. Liu, S. Ji, J. Wang, X. Yao, and Y. Zhu, "Study on characteristics and detection of DC arc fault in power electronics system," in Condition Monitoring and Diagnosis (CMD), 2012 International Conference on, 2012, pp. 1043-1046.
    • (2012) Condition Monitoring and Diagnosis (CMD) , pp. 1043-1046
    • Liu, Y.1    Ji, S.2    Wang, J.3    Yao, X.4    Zhu, Y.5
  • 6
    • 84901398049 scopus 로고    scopus 로고
    • aircraft systems
    • Third Edition ed. West Sussex: John Wiley&Sons Ltd
    • A. S. Ian Moir, aircraft systems, Third Edition ed. West Sussex: John Wiley&Sons Ltd, 2008.
    • (2008)
    • Ian Moir, A.S.1
  • 7
    • 12944335576 scopus 로고    scopus 로고
    • AIRCRAFT ELECTRIC POWER CHARACTERISTICS
    • in MIL-STD-704F, ed. usa
    • D. O. D. I. STANDARD, "AIRCRAFT ELECTRIC POWER CHARACTERISTICS," in MIL-STD-704F, ed. usa, 2004.
    • (2004)
    • Standard, D.O.D.I.1
  • 9
    • 0004088231 scopus 로고
    • Electric Contacts
    • 4th ed, New York:Springer
    • R.Holm, Electric Contacts, 4th ed. vol. pp.279-285:New York:Springer, 1967.
    • (1967) , pp. 279-285
    • Holm, R.1
  • 10
    • 2442457517 scopus 로고    scopus 로고
    • Voltage-current characteristics of breaking arc at constant opening speed in the air
    • J. Sekikawa and T. Kubono, "Voltage-current characteristics of breaking arc at constant opening speed in the air," Components and Packaging Technologies, IEEE Transactions on, vol. 27, pp. 167-171, 2004.
    • (2004) Components and Packaging Technologies, IEEE Transactions on , vol.27 , pp. 167-171
    • Sekikawa, J.1    Kubono, T.2
  • 11
    • 73649124941 scopus 로고    scopus 로고
    • A Simple Arc Model for the Simulation of the Clearing Time of Drawn Arcs with a Commercial Electronics Simulation Tool
    • in, 2009 Proceedings of the 55th IEEE Holm Conference on
    • P. Zeller, "A Simple Arc Model for the Simulation of the Clearing Time of Drawn Arcs with a Commercial Electronics Simulation Tool," in Electrical Contacts, 2009 Proceedings of the 55th IEEE Holm Conference on, 2009, pp. 67-74.
    • (2009) Electrical Contacts , pp. 67-74
    • Zeller, P.1
  • 12
    • 84904015400 scopus 로고    scopus 로고
    • Series Arc Fault Studies and Modeling for a DC Distribution System
    • presented at the the 5th IEEE PEC Asia-Pacific power and energy engineering conference(IEEE APPEEC 2013), Hong kong
    • Li. J, Thomas. D, S. Make, Christopher. E, and Cao. Y, "Series Arc Fault Studies and Modeling for a DC Distribution System "presented at the the 5th IEEE PEC Asia-Pacific power and energy engineering conference(IEEE APPEEC 2013), Hong kong, 2013.
    • (2013)
    • Li, J.1    Thomas, D.2    Make, S.3    Christopher, E.4    Cao, Y.5
  • 13
    • 84902599855 scopus 로고    scopus 로고
    • Arc Fault Generation and Detection in DC Systems
    • presented at the the 5th IEEE PEC Asia-Pacific power and energy engineering conference(IEEE APPEEC 2013), Hongkong
    • Cao. Y, Li. J, Sumner. M, Thomas. D, and Christopher. E, "Arc Fault Generation and Detection in DC Systems," presented at the the 5th IEEE PEC Asia-Pacific power and energy engineering conference(IEEE APPEEC 2013), Hongkong, 2013.
    • (2013)
    • Cao, Y.1    Li, J.2    Sumner, M.3    Thomas, D.4    Christopher, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.