메뉴 건너뛰기




Volumn 8, Issue 3, 2014, Pages 205-214

CT dose reduction using prospectively triggered or fast-pitch spiral technique employed in cardiothoracic imaging (the CT dose study)

(19)  Chinnaiyan, Kavitha M a   Bilolikar, Abhay N a   Walsh, Edward a   Wood, Daniel a   DePetris, Ann a   Gentry, Ralph a   Boura, Judith b   Abbara, Suhny c   Al Mallah, Mouaz d   Bis, Kostaki a   Boswell, Gilbert d   Gallagher, Michael e   Arunakul, Ing Orn a   Halliburton, Sandra a   Jacobs, Jill f   Lesser, John g   Schoepf, U Joseph h   Valeti, Uma S i,j,k   Raff, Gilbert L a  


Author keywords

DLP; Dose recommendation; High pitch; Prospective triggered; Radiation dose reduction

Indexed keywords

ADULT; AORTA DISEASE; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY DISEASE; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; LUNG EMBOLISM; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; QUANTITATIVE ANALYSIS; RADIATION DOSE REDUCTION; RETROSPECTIVE STUDY; AGE; BODY MASS; CARDIAC IMAGING; CLINICAL EVALUATION; CLINICAL PROTOCOL; DEVICE COMPARISON; ELECTROCARDIOGRAPHY; HEART RATE; HIGH PITCH SPIRAL COMPUTER ASSISTED TOMOGRAPHY; INTERMETHOD COMPARISON; MIDDLE AGED; MULTICENTER STUDY (TOPIC); RADIATION DOSE; RADIOLOGICAL PARAMETERS; SIGNAL NOISE RATIO; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; CLINICAL TRIAL; DEVICES; MULTICENTER STUDY; PROCEDURES; SIGNAL PROCESSING; TRENDS;

EID: 84902520898     PISSN: 19345925     EISSN: 1876861X     Source Type: Journal    
DOI: 10.1016/j.jcct.2014.04.001     Document Type: Article
Times cited : (23)

References (28)
  • 1
    • 34848893586 scopus 로고    scopus 로고
    • Thoracic aortic disease: spectrum of multidetector computed tomography imaging findings
    • Abbara S., Kalva S., Cury R.C., Isselbacher E.M. Thoracic aortic disease: spectrum of multidetector computed tomography imaging findings. JCardiovasc Comput Tomogr 2007, 1:40-54.
    • (2007) JCardiovasc Comput Tomogr , vol.1 , pp. 40-54
    • Abbara, S.1    Kalva, S.2    Cury, R.C.3    Isselbacher, E.M.4
  • 3
    • 84865610087 scopus 로고    scopus 로고
    • Imaging of thoracic aortic disease
    • Holloway B.J., Rosewarne D., Jones R.G. Imaging of thoracic aortic disease. Br J Radiol 2011, 84(Spec No 3):S338-S354.
    • (2011) Br J Radiol , vol.84 , Issue.SPEC NO 3
    • Holloway, B.J.1    Rosewarne, D.2    Jones, R.G.3
  • 4
    • 1642458217 scopus 로고    scopus 로고
    • CT angiography for diagnosis of pulmonary embolism: state of the art
    • Schoepf U.J., Costello P. CT angiography for diagnosis of pulmonary embolism: state of the art. Radiology 2004, 230:329-337.
    • (2004) Radiology , vol.230 , pp. 329-337
    • Schoepf, U.J.1    Costello, P.2
  • 5
    • 54349126659 scopus 로고    scopus 로고
    • 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis
    • Mowatt G., Cook J.A., Hillis G.S., et al. 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart 2008, 94:1386-1393.
    • (2008) Heart , vol.94 , pp. 1386-1393
    • Mowatt, G.1    Cook, J.A.2    Hillis, G.S.3
  • 6
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • Fazel R., Krumholz H.M., Wang Y., et al. Exposure to low-dose ionizing radiation from medical imaging procedures. NEngl J Med 2009, 361:849-857.
    • (2009) NEngl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3
  • 7
    • 73149113560 scopus 로고    scopus 로고
    • Projected cancer risks from computed tomographic scans performed in the United States in 2007
    • Berrington de Gonzalez A., Mahesh M., Kim K.P., et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 2009, 169:2071-2077.
    • (2009) Arch Intern Med , vol.169 , pp. 2071-2077
    • Berrington de Gonzalez, A.1    Mahesh, M.2    Kim, K.P.3
  • 8
    • 40849116360 scopus 로고    scopus 로고
    • Radiation dose and cancer risk estimates in 16-slice computed tomography coronary angiography
    • Einstein A.J., Sanz J., Dellegrottaglie S., et al. Radiation dose and cancer risk estimates in 16-slice computed tomography coronary angiography. JNucl Cardiol 2008, 15:232-240.
    • (2008) JNucl Cardiol , vol.15 , pp. 232-240
    • Einstein, A.J.1    Sanz, J.2    Dellegrottaglie, S.3
  • 9
    • 63449097524 scopus 로고    scopus 로고
    • High-pitch spiral acquisition: a new scan mode for coronary CT angiography
    • Achenbach S., Marwan M., Schepis T., et al. High-pitch spiral acquisition: a new scan mode for coronary CT angiography. JCardiovasc Comput Tomogr 2009, 3:117-121.
    • (2009) JCardiovasc Comput Tomogr , vol.3 , pp. 117-121
    • Achenbach, S.1    Marwan, M.2    Schepis, T.3
  • 11
    • 67649399882 scopus 로고    scopus 로고
    • Feasibility of dual-source cardiac CT angiography with high-pitch scan protocols
    • Hausleiter J., Bischoff B., Hein F., et al. Feasibility of dual-source cardiac CT angiography with high-pitch scan protocols. JCardiovasc Comput Tomogr 2009, 3:236-242.
    • (2009) JCardiovasc Comput Tomogr , vol.3 , pp. 236-242
    • Hausleiter, J.1    Bischoff, B.2    Hein, F.3
  • 12
    • 84884483541 scopus 로고    scopus 로고
    • Progressive radiation dose reduction from coronary computed tomography angiography in a statewide collaborative quality improvement program: results from the Advanced Cardiovascular Imaging Consortium
    • Chinnaiyan K.M., Boura J.A., DePetris A., et al. Progressive radiation dose reduction from coronary computed tomography angiography in a statewide collaborative quality improvement program: results from the Advanced Cardiovascular Imaging Consortium. Circ Cardiovasc Imaging 2013, 6:646-654.
    • (2013) Circ Cardiovasc Imaging , vol.6 , pp. 646-654
    • Chinnaiyan, K.M.1    Boura, J.A.2    DePetris, A.3
  • 13
    • 44949184468 scopus 로고    scopus 로고
    • New ICRP recommendations
    • Wrixon A.D. New ICRP recommendations. JRadiol Prot 2008, 28:161-168.
    • (2008) JRadiol Prot , vol.28 , pp. 161-168
    • Wrixon, A.D.1
  • 15
    • 76349094438 scopus 로고    scopus 로고
    • Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
    • Achenbach S., Marwan M., Ropers D., et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 2010, 31:340-346.
    • (2010) Eur Heart J , vol.31 , pp. 340-346
    • Achenbach, S.1    Marwan, M.2    Ropers, D.3
  • 16
    • 77953702967 scopus 로고    scopus 로고
    • Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode
    • Alkadhi H., Stolzmann P., Desbiolles L., et al. Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode. Heart 2010, 96:933-938.
    • (2010) Heart , vol.96 , pp. 933-938
    • Alkadhi, H.1    Stolzmann, P.2    Desbiolles, L.3
  • 18
    • 73949094933 scopus 로고    scopus 로고
    • High-pitch electrocardiogram-triggered computed tomography of the chest: initial results
    • Lell M., Hinkmann F., Anders K., et al. High-pitch electrocardiogram-triggered computed tomography of the chest: initial results. Invest Radiol 2009, 44:728-733.
    • (2009) Invest Radiol , vol.44 , pp. 728-733
    • Lell, M.1    Hinkmann, F.2    Anders, K.3
  • 19
    • 70350210490 scopus 로고    scopus 로고
    • Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience
    • Lell M., Marwan M., Schepis T., et al. Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol 2009, 19:2576-2583.
    • (2009) Eur Radiol , vol.19 , pp. 2576-2583
    • Lell, M.1    Marwan, M.2    Schepis, T.3
  • 20
    • 68549088465 scopus 로고    scopus 로고
    • Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I study
    • Bischoff B., Hein F., Meyer T., et al. Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I study. JACC Cardiovasc Imaging 2009, 2:940-946.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 940-946
    • Bischoff, B.1    Hein, F.2    Meyer, T.3
  • 21
    • 77955539456 scopus 로고    scopus 로고
    • Cardiac computed tomography technology and dose-reduction strategies
    • Earls J.P., Leipsic J. Cardiac computed tomography technology and dose-reduction strategies. Radiol Clin North Am 2010, 48:657-674.
    • (2010) Radiol Clin North Am , vol.48 , pp. 657-674
    • Earls, J.P.1    Leipsic, J.2
  • 22
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience
    • Marin D., Nelson R.C., Schindera S.T., et al. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience. Radiology 2010, 254:145-153.
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 23
    • 78650993428 scopus 로고    scopus 로고
    • Radiation dose from coronary CT angiography: five years of progress
    • Raff G.L. Radiation dose from coronary CT angiography: five years of progress. JCardiovasc Comput Tomogr 2010, 4:365-374.
    • (2010) JCardiovasc Comput Tomogr , vol.4 , pp. 365-374
    • Raff, G.L.1
  • 24
    • 80055098779 scopus 로고    scopus 로고
    • SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
    • Halliburton S.S., Abbara S., Chen M.Y., et al. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT. JCardiovasc Comput Tomogr 2011, 5:198-224.
    • (2011) JCardiovasc Comput Tomogr , vol.5 , pp. 198-224
    • Halliburton, S.S.1    Abbara, S.2    Chen, M.Y.3
  • 25
    • 59349099322 scopus 로고    scopus 로고
    • Appropriate use of cardiac computed tomography: applying the yardstick to clinical practice
    • Kaul P., Patel M.R. Appropriate use of cardiac computed tomography: applying the yardstick to clinical practice. JCardiovasc Comput Tomogr 2009, 3:22-23.
    • (2009) JCardiovasc Comput Tomogr , vol.3 , pp. 22-23
    • Kaul, P.1    Patel, M.R.2
  • 26
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: a catalog
    • Mettler F.A., Huda W., Yoshizumi T.T., Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 2008, 248:254-263.
    • (2008) Radiology , vol.248 , pp. 254-263
    • Mettler, F.A.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4
  • 27
    • 84868546832 scopus 로고    scopus 로고
    • Effects of protocol and obesity on dose conversion factors in adult body CT
    • Li X., Samei E., Williams C.H., et al. Effects of protocol and obesity on dose conversion factors in adult body CT. Med Phys 2012, 39:6550-6571.
    • (2012) Med Phys , vol.39 , pp. 6550-6571
    • Li, X.1    Samei, E.2    Williams, C.H.3
  • 28
    • 42949095856 scopus 로고    scopus 로고
    • On the use of MonteCarlo-derived dosimetric data in the estimation of patient dose from CT examinations
    • Perisinakis K., Tzedakis A., Damilakis J. On the use of MonteCarlo-derived dosimetric data in the estimation of patient dose from CT examinations. Med Phys 2008, 35:2018-2028.
    • (2008) Med Phys , vol.35 , pp. 2018-2028
    • Perisinakis, K.1    Tzedakis, A.2    Damilakis, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.