메뉴 건너뛰기




Volumn 59, Issue 13, 2014, Pages 3421-3430

A new dual threshold time-over-threshold circuit for fast timing in PET

Author keywords

positron emission tomography; time of flight; time over threshold

Indexed keywords

MEDICINE; PHYSICS;

EID: 84902479796     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/59/13/3421     Document Type: Article
Times cited : (46)

References (16)
  • 1
    • 79952792137 scopus 로고    scopus 로고
    • Improvement in lesion detection with whole-body oncologic time-of-flight PET
    • 10.2967/jnumed.110.080382
    • El Fakhri G, Surti S, Trott C M, Scheuermann J and Karp J S 2011 Improvement in lesion detection with whole-body oncologic time-of-flight PET J. Nucl. Med. 52 347-53
    • (2011) J. Nucl. Med. , vol.52 , pp. 347-353
    • El Fakhri, G.1    Surti, S.2    Trott, C.M.3    Scheuermann, J.4    Karp, J.S.5
  • 2
    • 79953826655 scopus 로고    scopus 로고
    • Multi-level time-over-threshold method for energy resolving multi-channel systems
    • 10.1109/TNS.2010.2061236 0018-9499
    • Fujiwara T, Takahashi H, Shimazoe K and Shi B 2010 Multi-level time-over-threshold method for energy resolving multi-channel systems IEEE Trans. Nucl. Sci. 57 2545-8
    • (2010) IEEE Trans. Nucl. Sci. , vol.57 , pp. 2545-2548
    • Fujiwara, T.1    Takahashi, H.2    Shimazoe, K.3    Shi, B.4
  • 3
    • 40449116151 scopus 로고    scopus 로고
    • Benefit of time-of-flight in PET: Experimental and clinical results
    • 10.2967/jnumed.107.044834
    • Karp J S, Surti S, Daube-Witherspoon M E and Muehllehner G 2008 Benefit of time-of-flight in PET: experimental and clinical results J. Nucl. Med. 49 462-70
    • (2008) J. Nucl. Med. , vol.49 , pp. 462-470
    • Karp, J.S.1    Surti, S.2    Daube-Witherspoon, M.E.3    Muehllehner, G.4
  • 5
    • 33747634688 scopus 로고    scopus 로고
    • A time-over-threshold machine: The readout integrated circuit for the BABAR silicon vertex tracker
    • 10.1109/23.603658 0018-9499
    • Kipnis I et al 1997 A time-over-threshold machine: the readout integrated circuit for the BABAR silicon vertex tracker IEEE Trans. Nucl. Sci. 44 289-97
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 289-297
    • Kipnis, I.1
  • 6
    • 0018940126 scopus 로고
    • Feasibility of time-of-flight reconstruction in positron emission tomography
    • 0161-5505
    • Mullani N A, Markham J and Ter-Pogossian M M 1980 Feasibility of time-of-flight reconstruction in positron emission tomography J. Nucl. Med. 21 1095-7 (PMID: 6968822)
    • (1980) J. Nucl. Med. , vol.21 , pp. 1095-1097
    • Mullani, N.A.1    Markham, J.2    Ter-Pogossian, M.M.3
  • 7
    • 84885955953 scopus 로고    scopus 로고
    • Design of a real-time FPGA-based data acquisition architecture for the LabPET II: An APD-based scanner dedicated to small animal PET imaging
    • 10.1109/TNS.2013.2250307 0018-9499
    • Njejimana L et al 2013 Design of a real-time FPGA-based data acquisition architecture for the LabPET II: an APD-based scanner dedicated to small animal PET imaging IEEE Trans. Nucl. Sci. 60 3633-8
    • (2013) IEEE Trans. Nucl. Sci. , vol.60 , pp. 3633-3638
    • Njejimana, L.1
  • 8
    • 67649191615 scopus 로고    scopus 로고
    • Pulse width modulation: A novel readout scheme for high energy photon detection
    • 10.1109/NSSMIC.2008.4774297
    • Olcott P D and Levin C S 2008 Pulse width modulation: a novel readout scheme for high energy photon detection IEEE Nuclear Science Symp. Conf. Record pp 4530-5
    • (2008) IEEE Nuclear Science Symp. Conf. Record , pp. 4530-4535
    • Olcott, P.D.1    Levin, C.S.2
  • 9
    • 79960847924 scopus 로고    scopus 로고
    • A new pulse width signal processing with delay-line and non-linear circuit (for ToT)
    • 10.1016/j.nima.2011.01.023 0168-9002 A
    • Orita T, Takahashi H, Shimazoe K, Fujiwara T and Boxuan S 2011 A new pulse width signal processing with delay-line and non-linear circuit (for ToT) Nucl. Instrum. Methods A 648 S24-S27
    • (2011) Nucl. Instrum. Methods , vol.648
    • Orita, T.1    Takahashi, H.2    Shimazoe, K.3    Fujiwara, T.4    Boxuan, S.5
  • 10
    • 0016631386 scopus 로고
    • Application of annihilation coincidence detection to transaxial reconstruction tomography
    • Phelps M E, Hoffman E J, Mullani N A and Ter-Pogossian M M 1975 Application of annihilation coincidence detection to transaxial reconstruction tomography J. Nucl. Med. 16 210-24 (PMID: 1113170)
    • (1975) J. Nucl. Med. , vol.16 , pp. 210-224
    • Phelps, M.E.1    Hoffman, E.J.2    Mullani, N.A.3    Ter-Pogossian, M.M.4
  • 11
    • 79959375306 scopus 로고    scopus 로고
    • Time-based readout of a silicon photomultiplier (SiPM) for time of flight positron emission tomography (TOF-PET)
    • 10.1109/TNS.2011.2119493 0018-9499
    • Powolny F et al 2011 Time-based readout of a silicon photomultiplier (SiPM) for time of flight positron emission tomography (TOF-PET) IEEE Trans. Nucl. Sci. 58 597-604
    • (2011) IEEE Trans. Nucl. Sci. , vol.58 , pp. 597-604
    • Powolny, F.1
  • 14
    • 0000119136 scopus 로고    scopus 로고
    • The role of flexibility in the development of new products: An empirical study
    • 10.1016/S0048-7333(96)00918-3 0048-7333
    • Thomke S H 1997 The role of flexibility in the development of new products: an empirical study Res. Policy 26 105-19
    • (1997) Res. Policy , vol.26 , pp. 105-119
    • Thomke, S.H.1
  • 16
    • 84873617319 scopus 로고    scopus 로고
    • Optimizing timing performance of silicon photomultiplier-based scintillation detectors
    • 10.1088/0031-9155/58/4/1207 0031-9155 1207
    • Yeom J Y, Vinke R and Levin C S 2013 Optimizing timing performance of silicon photomultiplier-based scintillation detectors Phys. Med. Biol. 58 1207-20
    • (2013) Phys. Med. Biol. , vol.58 , Issue.4 , pp. 1207-1220
    • Yeom, J.Y.1    Vinke, R.2    Levin, C.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.