메뉴 건너뛰기




Volumn 87, Issue 6, 2014, Pages 462-468

Validation of a photoacoustic gas analyser for the measurement of functional residual capacity using multiple-breath inert gas washout

Author keywords

Functional residual capacity; Pulmonary physiology; Validation

Indexed keywords

INERT GAS; SULFUR HEXAFLUORIDE;

EID: 84902243669     PISSN: 00257931     EISSN: 14230356     Source Type: Journal    
DOI: 10.1159/000357786     Document Type: Article
Times cited : (18)

References (8)
  • 3
    • 0001631321 scopus 로고
    • Studies on the intrapulmonary mixture of gases. III. An open circuit method for measuring residual air
    • Darling RC, Cournand A, Richards DW: Studies on the intrapulmonary mixture of gases. III. An open circuit method for measuring residual air. J Clin Invest 1940; 19: 609-618.
    • (1940) J Clin Invest , vol.19 , pp. 609-618
    • Darling, R.C.1    Cournand, A.2    Richards, D.W.3
  • 4
    • 84860477440 scopus 로고    scopus 로고
    • A realistic validation study of a new nitrogen multiple-breath washout system
    • Singer F, Houltz B, Latzin P, Robinson P, Gustafsson P: A realistic validation study of a new nitrogen multiple-breath washout system. PLoS One 2012; 7:e36083.
    • (2012) PLoS One , vol.7
    • Singer, F.1    Houltz, B.2    Latzin, P.3    Robinson, P.4    Gustafsson, P.5
  • 6
    • 0342451397 scopus 로고
    • Voluntary changes in breathing pattern and N2 clearance from lungs
    • Bouhuys A, Lichtneckert S, Lundgren C, Lundin G: Voluntary changes in breathing pattern and N2 clearance from lungs. J Appl Physiol 1961; 16: 1039-1042.
    • (1961) J Appl Physiol , vol.16 , pp. 1039-1042
    • Bouhuys, A.1    Lichtneckert, S.2    Lundgren, C.3    Lundin, G.4
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 84869500961 scopus 로고    scopus 로고
    • Variability of a closed, rebreathing setup for multiple breath wash-out testing in children
    • Pittman JE, Johnson RC, Jones PW, Davis SD: Variability of a closed, rebreathing setup for multiple breath wash-out testing in children. Pediatr Pulmonol 2012; 47: 1242-1250.
    • (2012) Pediatr Pulmonol , vol.47 , pp. 1242-1250
    • Pittman, J.E.1    Johnson, R.C.2    Jones, P.W.3    Davis, S.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.