메뉴 건너뛰기




Volumn 45, Issue 2, 2014, Pages 172-175

Blood collection from intravenous lines: Is one drawing site better than others?

Author keywords

Catheter; Hemolysis; Preanalytical variability; Sample quality

Indexed keywords

ADULT; ARTICLE; BASILIC VEIN; BLOOD SAMPLING; CATHETER; CEPHALIC VEIN; EMERGENCY WARD; FEMALE; HEMOLYSIS; HOSPITAL ADMISSION; HUMAN; MAJOR CLINICAL STUDY; MALE; MEDIAN ANTEROBRACHIAL VEIN; MEDIAN BASILIC VEIN; MEDIAN CEPHALIC VEIN; METACARPAL PLEXUS VEIN; PHOTOMETRY; RISK FACTOR; VEIN; VEIN CATHETERIZATION; ANTIBODY SPECIFICITY; EMERGENCY HEALTH SERVICE; INDWELLING CATHETER; MIDDLE AGED; PHLEBOTOMY; STANDARD;

EID: 84902085872     PISSN: 00075027     EISSN: 19437730     Source Type: Journal    
DOI: 10.1309/LM2XCV5SQML1ONTM     Document Type: Article
Times cited : (15)

References (6)
  • 1
    • 80052289159 scopus 로고    scopus 로고
    • Hemolyzed specimens: A major challenge for emergency departments and clinical laboratories
    • Lippi G, Plebani M, Di Somma S, Cervellin G. Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories. Crit Rev Clin Lab Sci. 2011;48(3):143-153.
    • (2011) Crit Rev Clin Lab Sci , vol.48 , Issue.3 , pp. 143-153
    • Lippi, G.1    Plebani, M.2    Di Somma, S.3    Cervellin, G.4
  • 2
    • 84866047714 scopus 로고    scopus 로고
    • Effectiveness of practices to reduce blood sample hemolysis in EDs: A laboratory medicine best practices systematic review and meta-analysis
    • Heyer NJ, Derzon JH, Winges L, at al. Effectiveness of practices to reduce blood sample hemolysis in EDs: a laboratory medicine best practices systematic review and meta-analysis. Clin Biochem. 2012;45(13-14):1012-1032.
    • (2012) Clin Biochem , vol.45 , Issue.13-14 , pp. 1012-1032
    • Heyer, N.J.1    Derzon, J.H.2    Winges, L.3
  • 3
    • 0036239525 scopus 로고    scopus 로고
    • Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists
    • Burns ER, Yoshikawa N. Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists. Lab Medicine. 2002;33(5):378-380.
    • (2002) Lab Medicine , vol.33 , Issue.5 , pp. 378-380
    • Burns, E.R.1    Yoshikawa, N.2
  • 4
    • 24044454046 scopus 로고    scopus 로고
    • Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department
    • Dugan L, Leech L, Speroni KG, Corriher J. Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department. J Emerg Nurs. 2005;31(4):338-445.
    • (2005) J Emerg Nurs , vol.31 , Issue.4 , pp. 338-445
    • Dugan, L.1    Leech, L.2    Speroni, K.G.3    Corriher, J.4
  • 5
    • 84867259653 scopus 로고    scopus 로고
    • Is phlebotomy part of the dark side in the clinical laboratory struggle for quality?
    • Lima-Oliveira G, Guidi GC, Salvagno GL, et al. Is phlebotomy part of the dark side in the clinical laboratory struggle for quality? Lab Medicine. 2012;43(5):172-176.
    • (2012) Lab Medicine , vol.43 , Issue.5 , pp. 172-176
    • Lima-Oliveira, G.1    Guidi, G.C.2    Salvagno, G.L.3
  • 6
    • 77951965160 scopus 로고    scopus 로고
    • Identification of the types of preanalytical errors in the clinical chemistry laboratory: 1-year study at G.B. Pant Hospital
    • Chawla R, Goswami B, Tayal D, Mallika V. Identification of the types of preanalytical errors in the clinical chemistry laboratory: 1-year study at G.B. Pant Hospital. Lab Medicine. 2010;41(2):89-92.
    • (2010) Lab Medicine , vol.41 , Issue.2 , pp. 89-92
    • Chawla, R.1    Goswami, B.2    Tayal, D.3    Mallika, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.