메뉴 건너뛰기




Volumn 15, Issue 11, 2013, Pages 1567-1573

Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: A randomized controlled study comparing the clinical outcome and safety; The AF-COR study

Author keywords

Atrial fibrillation; Catheter ablation; Cryoballoon; Phased RF; PVAC; Quality of life

Indexed keywords

AMIODARONE;

EID: 84901841136     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eut104     Document Type: Article
Times cited : (58)

References (25)
  • 1
    • 84859509560 scopus 로고    scopus 로고
    • 2012 Hrs/ehra/ecas expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design
    • Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA et al. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace 2012;14:528-606.
    • (2012) Europace , vol.14 , pp. 528-606
    • Calkins, H.1    Kuck, K.H.2    Cappato, R.3    Brugada, J.4    Camm, A.J.5    Chen, S.A.6
  • 2
    • 59749099384 scopus 로고    scopus 로고
    • Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with amultielectrode ablation catheter
    • Boersma LV,Wijffels MC, Oral H,Wever EF, Morady F. Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with amultielectrode ablation catheter. Heart Rhythm 2008;5:1635-42.
    • (2008) Heart Rhythm , vol.5 , pp. 1635-1642
    • Boersma, L.V.1    Wijffels, M.C.2    Oral, H.3    Wever, E.F.4    Morady, F.5
  • 3
    • 55249110821 scopus 로고    scopus 로고
    • Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation
    • Malmborg H, Lonnerholm S, Blomstrom-Lundqvist C. Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation. Europace 2008;10:1277-80.
    • (2008) Europace , vol.10 , pp. 1277-1280
    • Malmborg, H.1    Lonnerholm, S.2    Blomstrom-Lundqvist, C.3
  • 4
    • 47149112945 scopus 로고    scopus 로고
    • Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study
    • Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, NeuserHet al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. J Am Coll Cardiol 2008;52:273-8.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 273-278
    • Neumann, T.1    Vogt, J.2    Schumacher, B.3    Dorszewski, A.4    Kuniss, M.5    Neuser, H.6
  • 5
    • 55249120449 scopus 로고    scopus 로고
    • One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation
    • Van Belle Y, Janse P, Theuns D, Szili-Torok T, Jordaens L. One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation. Europace 2008;10:1271-6.
    • (2008) Europace , vol.10 , pp. 1271-1276
    • Van Belle, Y.1    Janse, P.2    Theuns, D.3    Szili-Torok, T.4    Jordaens, L.5
  • 6
    • 77956111336 scopus 로고    scopus 로고
    • Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: Medium-term outcomes and nonrandomised comparison with pulmonary venous isolation by radiofrequency ablation
    • Kojodjojo P, O'Neill MD, Lim PB, Malcolm-Lawes L, Whinnett ZI, Salukhe TV et al. Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: Medium-term outcomes and nonrandomised comparison with pulmonary venous isolation by radiofrequency ablation. Heart 2010;96:1379-84.
    • (2010) Heart , vol.96 , pp. 1379-1384
    • Kojodjojo, P.1    O'Neill, M.D.2    Lim, P.B.3    Malcolm-Lawes, L.4    Whinnett, Z.I.5    Salukhe, T.V.6
  • 7
    • 84861604946 scopus 로고    scopus 로고
    • Freedom from paroxysmal atrial fibrillation after successful pulmonary vein isolation with pulmonary vein ablation catheter-phased radiofrequency energy: 2-year follow-up and predictors of failure
    • Mulder AA, Wijffels MC,Wever EF, Boersma LV. Freedom from paroxysmal atrial fibrillation after successful pulmonary vein isolation with pulmonary vein ablation catheter-phased radiofrequency energy: 2-year follow-up and predictors of failure. Europace 2012;14:818-25.
    • (2012) Europace , vol.14 , pp. 818-825
    • Mulder, A.A.1    Wijffels McWever, E.F.2    Boersma, L.V.3
  • 8
    • 79961101981 scopus 로고    scopus 로고
    • Randomized study comparing duty-cycled bipolar and unipolar radiofrequency with point-by-point ablation in pulmonary vein isolation
    • Bittner A, Monnig G, Zellerhoff S, Pott C, Kobe J, Dechering D et al. Randomized study comparing duty-cycled bipolar and unipolar radiofrequency with point-by-point ablation in pulmonary vein isolation. Heart Rhythm 2011;8:1383-90.
    • (2011) Heart Rhythm , vol.8 , pp. 1383-1390
    • Bittner, A.1    Monnig, G.2    Zellerhoff, S.3    Pott, C.4    Kobe, J.5    Dechering, D.6
  • 9
    • 77956308846 scopus 로고    scopus 로고
    • Catheter ablation for paroxysmal atrial fibrillation: A randomized comparison between multielectrode catheter and point-by-point ablation
    • Bulava A, Hanis J, Sitek D, Osmera O, Karpianus D, SnorekMet al. Catheter ablation for paroxysmal atrial fibrillation: A randomized comparison between multielectrode catheter and point-by-point ablation. Pacing Clin Electrophysiol 2010;33:1039-46.
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 1039-1046
    • Bulava, A.1    Hanis, J.2    Sitek, D.3    Osmera, O.4    Karpianus, D.5    Snorek, M.6
  • 10
    • 77950223461 scopus 로고    scopus 로고
    • Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation
    • Beukema RP, Beukema WP, Smit JJ, Ramdat Misier AR, Delnoij PP,Wellens H et al. Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation. Europace 2010;12:502-7.
    • (2010) Europace , vol.12 , pp. 502-507
    • Beukema, R.P.1    Beukema, W.P.2    Smit, J.J.3    Ramdat Misier, A.R.4    Delnoij, P.P.5    Wellens, H.6
  • 11
    • 84856292930 scopus 로고    scopus 로고
    • Isolating the pulmonary veins as first-line therapy in patients with lone paroxysmal atrial fibrillation using the cryoballoon
    • Namdar M, Chierchia GB,Westra S, Sorgente A, Meir ML, Bayrak F et al. Isolating the pulmonary veins as first-line therapy in patients with lone paroxysmal atrial fibrillation using the cryoballoon. Europace 2012;14:197-203.
    • (2012) Europace , vol.14 , pp. 197-203
    • Namdar, M.1    Chierchia, G.B.2    Westra, S.3    Sorgente, A.4    Meir, M.L.5    Bayrak, F.6
  • 12
    • 80054957546 scopus 로고    scopus 로고
    • Pulmonary vein anatomy and longterm outcome after multi-electrode pulmonary vein isolation with phased radiofrequency energy for paroxysmal atrial fibrillation
    • Mulder AA, Wijffels MC,Wever EF, Boersma LV. Pulmonary vein anatomy and longterm outcome after multi-electrode pulmonary vein isolation with phased radiofrequency energy for paroxysmal atrial fibrillation. Europace 2011;13:1557-61.
    • (2011) Europace , vol.13 , pp. 1557-1561
    • Mulder, A.A.1    Wijffels, M.C.2    Wever, E.F.3    Boersma, L.V.4
  • 13
    • 77950367473 scopus 로고    scopus 로고
    • Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: First clinical results
    • Wieczorek M, Hoeltgen R, Brueck M, Bandorski D, Akin E, Salili AR. Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: First clinical results. J Interv Card Electrophysiol 2010;27:23-31.
    • (2010) J Interv Card Electrophysiol , vol.27 , pp. 23-31
    • Wieczorek, M.1    Hoeltgen, R.2    Brueck, M.3    Bandorski, D.4    Akin, E.5    Salili, A.R.6
  • 14
    • 44649124294 scopus 로고    scopus 로고
    • Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation
    • Klein G, Oswald H, Gardiwal A, Lusebrink U, Lissel C, YuHet al. Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation. Heart Rhythm 2008;5:802-6.
    • (2008) Heart Rhythm , vol.5 , pp. 802-806
    • Klein, G.1    Oswald, H.2    Gardiwal, A.3    Lusebrink, U.4    Lissel, C.5    Yu, H.6
  • 15
    • 64949092842 scopus 로고    scopus 로고
    • The single big cryoballoon technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study
    • Chun KR, Schmidt B, Metzner A, Tilz R, Zerm T, Koster I et al. The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study. Eur Heart J 2009; 30:699-709.
    • (2009) Eur Heart J , vol.30 , pp. 699-709
    • Chun, K.R.1    Schmidt, B.2    Metzner, A.3    Tilz, R.4    Zerm, T.5    Koster, I.6
  • 16
    • 84856216108 scopus 로고    scopus 로고
    • Cellular damage, platelet activation, and inflammatory response after pulmonary vein isolation: A randomized study comparing radiofrequency ablation with cryoablation
    • Herrera Siklody C, Arentz T, Minners J, Jesel L, Stratz C, Valina CM et al. Cellular damage, platelet activation, and inflammatory response after pulmonary vein isolation: A randomized study comparing radiofrequency ablation with cryoablation. Heart Rhythm 2012;9:189-96.
    • (2012) Heart Rhythm , vol.9 , pp. 189-196
    • Herrera Siklody, C.1    Arentz, T.2    Minners, J.3    Jesel, L.4    Stratz, C.5    Valina, C.M.6
  • 17
    • 78650226421 scopus 로고    scopus 로고
    • Improvements in symptoms and quality of life in patients with paroxysmal atrial fibrillation treated with radiofrequency catheter ablation versus antiarrhythmic drugs
    • Reynolds MR,Walczak J, White SA, Cohen DJ, Wilber DJ. Improvements in symptoms and quality of life in patients with paroxysmal atrial fibrillation treated with radiofrequency catheter ablation versus antiarrhythmic drugs. Circ Cardiovasc Qual Outcomes 2010;3:615-23.
    • (2010) Circ Cardiovasc Qual Outcomes , vol.3 , pp. 615-623
    • Reynolds, M.R.1    Walczak, J.2    White, S.A.3    Cohen, D.J.4    Wilber, D.J.5
  • 18
    • 77952163349 scopus 로고    scopus 로고
    • Long-term quality of life after ablation of atrial fibrillation the impact of recurrence, symptom relief, and placebo effect
    • Wokhlu A, Monahan KH, Hodge DO, Asirvatham SJ, Friedman PA, Munger TM et al. Long-term quality of life after ablation of atrial fibrillation the impact of recurrence, symptom relief, and placebo effect. J Am Coll Cardiol 2010;55:2308-16.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 2308-2316
    • Wokhlu, A.1    Monahan, K.H.2    Hodge, D.O.3    Asirvatham, S.J.4    Friedman, P.A.5    Munger, T.M.6
  • 19
    • 78650176642 scopus 로고    scopus 로고
    • Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: Biomarkers of myocardial injury, recurrence rates, and pulmonary vein reconnection patterns
    • Kuhne M, Suter Y, Altmann D, Ammann P, Schaer B, Osswald S et al. Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: Biomarkers of myocardial injury, recurrence rates, and pulmonary vein reconnection patterns. Heart Rhythm 2010;7:1770-6.
    • (2010) Heart Rhythm , vol.7 , pp. 1770-1776
    • Kuhne, M.1    Suter, Y.2    Altmann, D.3    Ammann, P.4    Schaer, B.5    Osswald, S.6
  • 20
    • 70450215228 scopus 로고    scopus 로고
    • Comparison of cryoballoon and radiofrequency ablation of pulmonary veins in 40 patients with paroxysmal atrial fibrillation: A case-control study
    • Linhart M, Bellmann B, Mittmann-Braun E, Schrickel JW, Bitzen A, Andrie R et al. Comparison of cryoballoon and radiofrequency ablation of pulmonary veins in 40 patients with paroxysmal atrial fibrillation: A case-control study. J Cardiovasc Electrophysiol 2009;20:1343-8.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1343-1348
    • Linhart, M.1    Bellmann, B.2    Mittmann-Braun, E.3    Schrickel, J.W.4    Bitzen, A.5    Andrie, R.6
  • 21
    • 65249190133 scopus 로고    scopus 로고
    • Early recovery of pulmonary vein conduction after cryoballoon ablation for paroxysmal atrial fibrillation: A prospective study
    • Chierchia GB, de Asmundis C, Muller-Burri SA, Sarkozy A, Capulzini L, Paparella G et al. Early recovery of pulmonary vein conduction after cryoballoon ablation for paroxysmal atrial fibrillation: A prospective study. Europace 2009;11:445-9.
    • (2009) Europace , vol.11 , pp. 445-449
    • Chierchia, G.B.1    De Asmundis, C.2    Muller-Burri, S.A.3    Sarkozy, A.4    Capulzini, L.5    Paparella, G.6
  • 24
    • 84869800181 scopus 로고    scopus 로고
    • Adenosine testing after cryoballoon pulmonary vein isolation improves long-term clinical outcome
    • Van Belle Y, Janse PA, Groot NMS, Anné W, Theuns DAMJ, Jordaens LJ. Adenosine testing after cryoballoon pulmonary vein isolation improves long-term clinical outcome. Neth Heart J 2012;20:447-55.
    • (2012) Neth Heart J , vol.20 , pp. 447-455
    • Van Belle, Y.1    Janse, P.A.2    Groot, N.M.S.3    Anné, W.4    Damj, T.5    Jordaens, L.J.6
  • 25
    • 84857876811 scopus 로고    scopus 로고
    • Influence of the anatomic characteristics of the pulmonary vein ostium, the learning curve, and the use of a steerable sheath on success of pulmonary vein isolation with a novel multielectrode ablation catheter
    • Brunelli M, Raffa S, Grosse A,Wauters K, Menoni S, SchreiberMet al. Influence of the anatomic characteristics of the pulmonary vein ostium, the learning curve, and the use of a steerable sheath on success of pulmonary vein isolation with a novel multielectrode ablation catheter. Europace 2012;14:331-40.
    • (2012) Europace , vol.14 , pp. 331-340
    • Brunelli, M.1    Raffa, S.2    Grosse, A.3    Wauters, K.4    Menoni, S.5    Schreiber, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.