-
1
-
-
0028978123
-
Systems analysis of adverse drug events
-
ADE Prevention Study Group
-
Leape LL, Bates DW, Cullen DJ et al. Systems analysis of adverse drug events. ADE Prevention Study Group. JAMA. 1995; 274:35-43.
-
(1995)
JAMA
, vol.274
, pp. 35-43
-
-
Leape, L.L.1
Bates, D.W.2
Cullen, D.J.3
-
2
-
-
0028967503
-
Errors in drug administration by nurses
-
Pepper GA. Errors in drug administration by nurses. Am J Health-Syst Pharm. 1995; 52:390-5.
-
(1995)
Am J Health-Syst Pharm
, vol.52
, pp. 390-395
-
-
Pepper, G.A.1
-
3
-
-
0004001942
-
-
National Coordinating Council for Medication Error Reporting and Prevention. NCCMERP taxonomy of medication errors. www.nccmerp.org/aboutMed Errors.html (accessed 2012 Feb 4).
-
NCCMERP Taxonomy of Medication Errors
-
-
-
4
-
-
0035946697
-
Medication errors and adverse drug events in pediatric inpatients
-
Kaushal R, Bates DW, Landrigan C et al. Medication errors and adverse drug events in pediatric inpatients. JAMA. 2001; 285:2114-20.
-
(2001)
JAMA
, vol.285
, pp. 2114-2120
-
-
Kaushal, R.1
Bates, D.W.2
Landrigan, C.3
-
5
-
-
84860550790
-
Long-term reduction in adverse drug events: An evidence-based improvement model
-
Gazarian M, Graudins LV. Long-term reduction in adverse drug events: an evidence-based improvement model. Pediatrics. 2012; 129:e1334-42.
-
(2012)
Pediatrics
, vol.129
, pp. e1334-e1342
-
-
Gazarian, M.1
Graudins, L.V.2
-
6
-
-
2342516186
-
Managing i.v. therapy: "High-alert" drugs keep nurse managers ever watchful
-
Hadaway LC. Managing i.v. therapy: "high-alert" drugs keep nurse managers ever watchful. Nurs Manage. 2000; 31(10):38-40.
-
(2000)
Nurs Manage
, vol.31
, Issue.10
, pp. 38-40
-
-
Hadaway, L.C.1
-
7
-
-
1542348474
-
Malpractice and the neonatal intensive-care nurse
-
Verklan MT. Malpractice and the neonatal intensive-care nurse. J Obstet Gynecol Neonatal Nurs. 2004; 33:116-23.
-
(2004)
J Obstet Gynecol Neonatal Nurs
, vol.33
, pp. 116-123
-
-
Verklan, M.T.1
-
8
-
-
10044221936
-
Medication errors in pediatrics - The octopus evading defeat
-
Sullivan JE, Buchino JJ. Medication errors in pediatrics - the octopus evading defeat. J Surg Oncol. 2004; 88:182-8.
-
(2004)
J Surg Oncol
, vol.88
, pp. 182-188
-
-
Sullivan, J.E.1
Buchino, J.J.2
-
12
-
-
80052819766
-
Smart pump technology
-
Dumitru D, ed. Bethesda, MD: American Society of Health-System Pharmacists
-
Giannopoulos HT. Smart pump technology. In: Dumitru D, ed. The pharmacy informatics primer. Bethesda, MD: American Society of Health-System Pharmacists; 2008:119-27.
-
(2008)
The Pharmacy Informatics Primer
, pp. 119-127
-
-
Giannopoulos, H.T.1
-
19
-
-
54049085795
-
Updated classification for medication errors by the Ruiz-Jarabo 2000 Group
-
In Spanish
-
Otero Lopez MJ, Castano Rodriguez B, Perez Encinas M et al. [Updated classification for medication errors by the Ruiz-Jarabo 2000 Group.] Farm Hosp. 2008; 32(1):38-52. In Spanish.
-
(2008)
Farm Hosp
, vol.32
, Issue.1
, pp. 38-52
-
-
Otero Lopez, M.J.1
Castano Rodriguez, B.2
Perez Encinas, M.3
-
20
-
-
0017360990
-
The measurement of observer agreement for categorical data
-
Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977; 33:159-74.
-
(1977)
Biometrics
, vol.33
, pp. 159-174
-
-
Landis, J.R.1
Koch, G.G.2
-
21
-
-
84907154710
-
-
In Spanish
-
ISMP Spain. [List of high-risk medications, 2008.] www.ismp-espana.org/estaticos/view/39 (accessed 2012 Feb 19). In Spanish.
-
(2008)
List of High-risk Medications
-
-
-
23
-
-
79952031726
-
Continuous quality improvement using intelligent infusion pump data analysis
-
Breland BD. Continuous quality improvement using intelligent infusion pump data analysis. Am J Health-Syst Pharm. 2010; 67:1446-55.
-
(2010)
Am J Health-Syst Pharm
, vol.67
, pp. 1446-1455
-
-
Breland, B.D.1
-
24
-
-
77955900073
-
Implementation of intelligent infusion technology in a multihospital setting
-
Dusing Wiest M, Longshore L, Harger N. Implementation of intelligent infusion technology in a multihospital setting. Am J Health-Syst Pharm. 2010; 67:878-83.
-
(2010)
Am J Health-Syst Pharm
, vol.67
, pp. 878-883
-
-
Dusing Wiest, M.1
Longshore, L.2
Harger, N.3
-
25
-
-
33947580202
-
Impact of smart infusion technology on administration of anticoagulants (unfractionated heparin, argatroban, lepirudin, and bivalirudin)
-
Fanikos J, Fiumara K, Baroletti S et al. Impact of smart infusion technology on administration of anticoagulants (unfractionated heparin, argatroban, lepirudin, and bivalirudin). Am J Cardiol. 2007; 99:1002-5.
-
(2007)
Am J Cardiol
, vol.99
, pp. 1002-1005
-
-
Fanikos, J.1
Fiumara, K.2
Baroletti, S.3
-
26
-
-
14944351088
-
A controlled trial of smart infusion pumps to improve medication safety in critically ill patients
-
Rothschild JM, Keohane CA, Cook EF et al. A controlled trial of smart infusion pumps to improve medication safety in critically ill patients. Crit Care Med. 2005; 33:533-40.
-
(2005)
Crit Care Med
, vol.33
, pp. 533-540
-
-
Rothschild, J.M.1
Keohane, C.A.2
Cook, E.F.3
-
27
-
-
17144413786
-
Insights from the sharp end of intravenous medication errors: Implications for infusion pump technology
-
Husch M, Sullivan C, Rooney D et al. Insights from the sharp end of intravenous medication errors: implications for infusion pump technology. Qual Saf Health Care. 2005; 14:80-6.
-
(2005)
Qual Saf Health Care
, vol.14
, pp. 80-86
-
-
Husch, M.1
Sullivan, C.2
Rooney, D.3
-
28
-
-
37349020257
-
Programmable infusion pumps in ICUs: An analysis of corresponding adverse drug events
-
Nuckols TK, Bower AG, Paddock SM et al. Programmable infusion pumps in ICUs: an analysis of corresponding adverse drug events. J Gen Intern Med. 2008; 23(suppl 1):41-5.
-
(2008)
J Gen Intern Med
, vol.23
, pp. 41-45
-
-
Nuckols, T.K.1
Bower, A.G.2
Paddock, S.M.3
-
29
-
-
0019799332
-
A method for estimating the probability of adverse drug reactions
-
Naranjo CA, Busto U, Sellers EM et al. A method for estimating the probability of adverse drug reactions. Clin Pharmacol Ther. 1981; 30:239-45.
-
(1981)
Clin Pharmacol Ther
, vol.30
, pp. 239-245
-
-
Naranjo, C.A.1
Busto, U.2
Sellers, E.M.3
-
30
-
-
0037637699
-
The validation of an existing method of scoring the severity of medication administration errors for use in Germany
-
Taxis K, Dean B, Barber N. The validation of an existing method of scoring the severity of medication administration errors for use in Germany. Pharm World Sci. 2002; 24:236-9.
-
(2002)
Pharm World Sci
, vol.24
, pp. 236-239
-
-
Taxis, K.1
Dean, B.2
Barber, N.3
-
31
-
-
0032924423
-
A validated, reliable method of scoring the severity of medication errors
-
Dean BS, Barber ND. A validated, reliable method of scoring the severity of medication errors. Am J Health-Syst Pharm. 1999; 56:57-62.
-
(1999)
Am J Health-Syst Pharm
, vol.56
, pp. 57-62
-
-
Dean, B.S.1
Barber, N.D.2
-
32
-
-
36749062403
-
Cost implications of and potential adverse events prevented by interventions of a critical care pharmacist
-
Kopp BJ, Mrsan M, Erstad BL et al. Cost implications of and potential adverse events prevented by interventions of a critical care pharmacist. Am J Health-Syst Pharm. 2007; 64:2483-7.
-
(2007)
Am J Health-Syst Pharm
, vol.64
, pp. 2483-2487
-
-
Kopp, B.J.1
Mrsan, M.2
Erstad, B.L.3
-
33
-
-
0022631552
-
An eleven-year review of the pharmacy literature: Documentation of the value and acceptance of clinical pharmacy
-
Hatoum HT, Catizone C, Hutchinson RA et al. An eleven-year review of the pharmacy literature: documentation of the value and acceptance of clinical pharmacy. Drug Intell Clin Pharm. 1986; 20:33-48.
-
(1986)
Drug Intell Clin Pharm
, vol.20
, pp. 33-48
-
-
Hatoum, H.T.1
Catizone, C.2
Hutchinson, R.A.3
-
34
-
-
0033485439
-
Practical, reliable, comprehensive method for characterizing pharmacists' clinical activities
-
Overhage JM, Lukes A. Practical, reliable, comprehensive method for characterizing pharmacists' clinical activities. Am J Health-Syst Pharm. 1999; 56:2444-50.
-
(1999)
Am J Health-Syst Pharm
, vol.56
, pp. 2444-2450
-
-
Overhage, J.M.1
Lukes, A.2
-
35
-
-
51649085556
-
Severity of medication administration errors detected by a bar-code medication administration system
-
Sakowski J, Newman JM, Dozier K. Severity of medication administration errors detected by a bar-code medication administration system. Am J Health-Syst Pharm. 2008; 65:1661-6.
-
(2008)
Am J Health-Syst Pharm
, vol.65
, pp. 1661-1666
-
-
Sakowski, J.1
Newman, J.M.2
Dozier, K.3
-
36
-
-
0023256955
-
Medication error prevention by clinical pharmacists in two children's hospitals
-
Folli HL, Poole RL, Benitz WE et al. Medication error prevention by clinical pharmacists in two children's hospitals. Pediatrics. 1987; 79:718-22.
-
(1987)
Pediatrics
, vol.79
, pp. 718-722
-
-
Folli, H.L.1
Poole, R.L.2
Benitz, W.E.3
|