메뉴 건너뛰기




Volumn 70, Issue , 2014, Pages 674-684

Design and thermodynamic analysis of a hybrid energy storage system based on A-CAES (adiabatic compressed air energy storage) and FESS (flywheel energy storage system) for wind power application

Author keywords

Adiabatic compressed air energy storage system; Flywheel energy storage system; Hybrid energy storage system; Off design analysis; Parametric analysis; Wind energy

Indexed keywords

CAVES; COMPRESSED AIR; DESIGN; FLYWHEEL PROPULSION; PRESSURE VESSELS; THERMOANALYSIS; WIND POWER;

EID: 84901650627     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2014.04.055     Document Type: Article
Times cited : (145)

References (25)
  • 2
    • 78649636358 scopus 로고    scopus 로고
    • Energy storage for mitigating the variability of renewable electricity sources: an updated review
    • Beaudin M., Zareipour H., Schellenberglabe A., Rosehart W. Energy storage for mitigating the variability of renewable electricity sources: an updated review. Energy Sustain Dev 2010, 14(4):302-314.
    • (2010) Energy Sustain Dev , vol.14 , Issue.4 , pp. 302-314
    • Beaudin, M.1    Zareipour, H.2    Schellenberglabe, A.3    Rosehart, W.4
  • 3
    • 41849116011 scopus 로고    scopus 로고
    • Energy storage systems - characteristics and comparisons
    • Ibrahim H., Ilinca A., Perron J. Energy storage systems - characteristics and comparisons. Renew Sust Energ Rev 2008, 12(5):1221-1250.
    • (2008) Renew Sust Energ Rev , vol.12 , Issue.5 , pp. 1221-1250
    • Ibrahim, H.1    Ilinca, A.2    Perron, J.3
  • 4
    • 82455191788 scopus 로고    scopus 로고
    • Analysis of a pumped storage system to increase the penetration level of renewable energy in isolated power systems. Gran Canaria: a case study
    • Padrón S., Medina J.F., Rodríguez A. Analysis of a pumped storage system to increase the penetration level of renewable energy in isolated power systems. Gran Canaria: a case study. Energy 2011, 36(12):6753-6762.
    • (2011) Energy , vol.36 , Issue.12 , pp. 6753-6762
    • Padrón, S.1    Medina, J.F.2    Rodríguez, A.3
  • 5
    • 77953321386 scopus 로고    scopus 로고
    • Energy balance analysis of wind-based pumped hydro storage systems in remote island electrical networks
    • Kaldellis J.K., Kapsali M., Kavadias K.A. Energy balance analysis of wind-based pumped hydro storage systems in remote island electrical networks. Appl Energy 2010, 87(8):2427-2437.
    • (2010) Appl Energy , vol.87 , Issue.8 , pp. 2427-2437
    • Kaldellis, J.K.1    Kapsali, M.2    Kavadias, K.A.3
  • 6
    • 84880698975 scopus 로고    scopus 로고
    • Impacts of compressed air energy storage plant on an electricity market with a large renewable energy portfolio
    • Foley A., Díaz Lobera I. Impacts of compressed air energy storage plant on an electricity market with a large renewable energy portfolio. Energy 2013, 57(0):85-94.
    • (2013) Energy , vol.57 , Issue.0 , pp. 85-94
    • Foley, A.1    Díaz Lobera, I.2
  • 7
    • 33750365221 scopus 로고    scopus 로고
    • Controllable and affordable utility-scale electricity from intermittent wind resources and compressed air energy storage (CAES)
    • Cavallo A. Controllable and affordable utility-scale electricity from intermittent wind resources and compressed air energy storage (CAES). Energy 2007, 32(2):120-127.
    • (2007) Energy , vol.32 , Issue.2 , pp. 120-127
    • Cavallo, A.1
  • 8
    • 84877903080 scopus 로고    scopus 로고
    • Energy management of flywheel-based energy storage device for wind power smoothing
    • Díaz-González F., Sumper A., Gomis-Bellmunt O., Bianchi F.D. Energy management of flywheel-based energy storage device for wind power smoothing. Appl Energy 2013, 110(0):207-219.
    • (2013) Appl Energy , vol.110 , Issue.0 , pp. 207-219
    • Díaz-González, F.1    Sumper, A.2    Gomis-Bellmunt, O.3    Bianchi, F.D.4
  • 9
    • 77349090409 scopus 로고    scopus 로고
    • Amodel predictive control approach to the problem of wind power smoothing with controlled battery storage
    • Khalid M., Savkin A.V. Amodel predictive control approach to the problem of wind power smoothing with controlled battery storage. Renew Energy 2010, 35(7):1520-1526.
    • (2010) Renew Energy , vol.35 , Issue.7 , pp. 1520-1526
    • Khalid, M.1    Savkin, A.V.2
  • 10
    • 73249129246 scopus 로고    scopus 로고
    • Effective active power control of a high penetration wind diesel system with a Ni-Cd battery energy storage
    • Sebastián R., Alzola R.P. Effective active power control of a high penetration wind diesel system with a Ni-Cd battery energy storage. Renew Energy 2010, 35(5):952-965.
    • (2010) Renew Energy , vol.35 , Issue.5 , pp. 952-965
    • Sebastián, R.1    Alzola, R.P.2
  • 11
    • 80051583700 scopus 로고    scopus 로고
    • Charging dynamics of metal hydride hydrogen storage bed for small wind hybrid systems
    • Raju M., Khaitan S. Charging dynamics of metal hydride hydrogen storage bed for small wind hybrid systems. Int J Hydrogen Energy 2011, 36(17):10797-10807.
    • (2011) Int J Hydrogen Energy , vol.36 , Issue.17 , pp. 10797-10807
    • Raju, M.1    Khaitan, S.2
  • 12
    • 78649893093 scopus 로고    scopus 로고
    • Wind/hydrogen hybrid systems: opportunity for Ireland's wind resource to provide consistent sustainable energy supply
    • Carton J.G., Olabi A.G. Wind/hydrogen hybrid systems: opportunity for Ireland's wind resource to provide consistent sustainable energy supply. Energy 2010, 35(12):4536-4544.
    • (2010) Energy , vol.35 , Issue.12 , pp. 4536-4544
    • Carton, J.G.1    Olabi, A.G.2
  • 13
    • 58249105360 scopus 로고    scopus 로고
    • Power oscillation suppression by robust SMES in power system with large wind power penetration
    • Ngamroo I., Cuk Supriyadi A.N., Dechanupaprittha S., Mitani Y. Power oscillation suppression by robust SMES in power system with large wind power penetration. Phys C Supercond 2009, 469(1):44-51.
    • (2009) Phys C Supercond , vol.469 , Issue.1 , pp. 44-51
    • Ngamroo, I.1    Cuk Supriyadi, A.N.2    Dechanupaprittha, S.3    Mitani, Y.4
  • 14
    • 79961026027 scopus 로고    scopus 로고
    • Electric power generation based on variable speed wind turbine under load disturbance
    • Masmoudi A., Abdelkafi A., Krichen L. Electric power generation based on variable speed wind turbine under load disturbance. Energy 2011, 36(8):5016-5026.
    • (2011) Energy , vol.36 , Issue.8 , pp. 5016-5026
    • Masmoudi, A.1    Abdelkafi, A.2    Krichen, L.3
  • 15
    • 34248524480 scopus 로고    scopus 로고
    • The spectrum of power from wind turbines
    • Apt J. The spectrum of power from wind turbines. JPower Sources 2007, 169(2):369-374.
    • (2007) JPower Sources , vol.169 , Issue.2 , pp. 369-374
    • Apt, J.1
  • 16
    • 84862667693 scopus 로고    scopus 로고
    • GA based frequency controller for solar thermal-diesel-wind hybrid energy generation/energy storage system
    • Das D.C., Roy A.K., Sinha N. GA based frequency controller for solar thermal-diesel-wind hybrid energy generation/energy storage system. Int J Elec Power 2012, 43(1):262-279.
    • (2012) Int J Elec Power , vol.43 , Issue.1 , pp. 262-279
    • Das, D.C.1    Roy, A.K.2    Sinha, N.3
  • 17
    • 84875641755 scopus 로고    scopus 로고
    • Techno-economic evaluation of hybrid energy storage technologies for a solar-wind generation system
    • Ren L., Tang Y., Shi J., Dou J., Zhou S., Jin T. Techno-economic evaluation of hybrid energy storage technologies for a solar-wind generation system. Phys C Supercond 2013, 484(0):272-275.
    • (2013) Phys C Supercond , vol.484 , Issue.0 , pp. 272-275
    • Ren, L.1    Tang, Y.2    Shi, J.3    Dou, J.4    Zhou, S.5    Jin, T.6
  • 18
    • 80053266728 scopus 로고    scopus 로고
    • Simulations of economical and technical feasibility of battery and flywheel hybrid energy storage systems in autonomous projects
    • Prodromidis G.N., Coutelieris F.A. Simulations of economical and technical feasibility of battery and flywheel hybrid energy storage systems in autonomous projects. Renew Energy 2012, 39(1):149-153.
    • (2012) Renew Energy , vol.39 , Issue.1 , pp. 149-153
    • Prodromidis, G.N.1    Coutelieris, F.A.2
  • 19
    • 84863771060 scopus 로고    scopus 로고
    • An autonomous hybrid energy system of wind/tidal/microturbine/battery storage
    • Mousavi G.S.M. An autonomous hybrid energy system of wind/tidal/microturbine/battery storage. Int J Elec Power 2012, 43(1):1144-1154.
    • (2012) Int J Elec Power , vol.43 , Issue.1 , pp. 1144-1154
    • Mousavi, G.S.M.1
  • 20
    • 84860793159 scopus 로고    scopus 로고
    • Green solution for power generation by adoption of adiabatic CAES system
    • Jubeh N.M., Najjar Y.S.H. Green solution for power generation by adoption of adiabatic CAES system. Appl Therm Eng 2012, 44:85-89.
    • (2012) Appl Therm Eng , vol.44 , pp. 85-89
    • Jubeh, N.M.1    Najjar, Y.S.H.2
  • 22
    • 0028419333 scopus 로고
    • Models for predicting the performance of Brayton-cycle engines
    • Korakianitis T., Wilson D.G. Models for predicting the performance of Brayton-cycle engines. JEng Gas Turb Power 1994, 116(2):381-388.
    • (1994) JEng Gas Turb Power , vol.116 , Issue.2 , pp. 381-388
    • Korakianitis, T.1    Wilson, D.G.2