메뉴 건너뛰기




Volumn 432, Issue , 2014, Pages 49-54

Update on current concepts and meanings in laboratory medicine - Standardization, traceability and harmonization

Author keywords

Calibration; Harmonization; Metrology; SI; Standardization; Traceability

Indexed keywords

ACCREDITATION; ARTICLE; CALIBRATION; CLINICAL LABORATORY; GOOD LABORATORY PRACTICE; HARMONIZATION; HEALTH CARE AVAILABILITY; HEALTH CARE DELIVERY; HEALTH CARE NEED; HUMAN; INTERMETHOD COMPARISON; LABORATORY MEDICINE; LABORATORY TEST; MEDICAL DOCUMENTATION; MEDICINE; PRIORITY JOURNAL; QUALITY CONTROL PROCEDURES; REPRODUCIBILITY; STANDARDIZATION; TRACEABILITY; DIAGNOSTIC PROCEDURE; STANDARD; STANDARDS;

EID: 84901591111     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2013.12.045     Document Type: Article
Times cited : (30)

References (28)
  • 1
    • 1842458410 scopus 로고    scopus 로고
    • Development and use of biomarkers in oncology drug development
    • Floyd E., McShane T.M. Development and use of biomarkers in oncology drug development. Toxicol Pathol 2004, 32(Suppl. 1):106-115.
    • (2004) Toxicol Pathol , vol.32 , Issue.SUPPL. 1 , pp. 106-115
    • Floyd, E.1    McShane, T.M.2
  • 2
    • 0023728740 scopus 로고
    • Current status of blood cholesterol measurement in clinical laboratories in the unitEd States: a report of the laboratory standardization panel of the national cholesterol education program
    • Laboratory Standardization Panel of the National Cholesterol Education Program
    • Laboratory Standardization Panel of the National Cholesterol Education Program Current status of blood cholesterol measurement in clinical laboratories in the unitEd States: a report of the laboratory standardization panel of the national cholesterol education program. Clin Chem 1988, 34:193-201.
    • (1988) Clin Chem , vol.34 , pp. 193-201
  • 3
    • 0033756323 scopus 로고    scopus 로고
    • A reference method laboratory network for cholesterol: a model for standardization and improvement of clinical laboratory measurements
    • Myers G.L., Kimberly M.M., Waymack P.P., Smith S.J., Cooper G.R., Sampson E.J. A reference method laboratory network for cholesterol: a model for standardization and improvement of clinical laboratory measurements. Clin Chem 2000, 46:1762-1772.
    • (2000) Clin Chem , vol.46 , pp. 1762-1772
    • Myers, G.L.1    Kimberly, M.M.2    Waymack, P.P.3    Smith, S.J.4    Cooper, G.R.5    Sampson, E.J.6
  • 5
    • 84857469870 scopus 로고    scopus 로고
    • A cost-benefit analysis of lipid standardization in the United States
    • [Available from:Accessed 10JUN2013]
    • Hoerger T.J., Wittenborn J.S., Young W. A cost-benefit analysis of lipid standardization in the United States. Prev Chronic Dis 2011, 8:A136. [Available from: http://www.cdc.gov/pcd/issues/2011/nov/10_0253.htm [Accessed 10JUN2013]].
    • (2011) Prev Chronic Dis , vol.8
    • Hoerger, T.J.1    Wittenborn, J.S.2    Young, W.3
  • 8
    • 84901629633 scopus 로고    scopus 로고
    • 21CFR 809.10 Available from, [Accessed 10JUN2013], United States Code of Federal Regulations
    • United States Code of Federal Regulations 21CFR 809.10 Available from, [Accessed 10JUN2013]. http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/Overview/DeviceLabeling/InVitroDiagnosticDeviceLabelingRequirements/default.htm.
  • 9
    • 84872388578 scopus 로고    scopus 로고
    • Harmonisation of measurement procedures: how do we get it done?
    • Gantzer M.L., Miller W.G. Harmonisation of measurement procedures: how do we get it done?. Clin Biochem Rev 2012, 33:95-100.
    • (2012) Clin Biochem Rev , vol.33 , pp. 95-100
    • Gantzer, M.L.1    Miller, W.G.2
  • 11
    • 84901644820 scopus 로고    scopus 로고
    • American Association for Clinical Chemistry. Clinical Laboratory Test Harmonization - Harmonization.net. Available from:Accessed 07JUN2013.
    • American Association for Clinical Chemistry. Clinical Laboratory Test Harmonization - Harmonization.net. Available from: http://www.harmonization.net/Pages/default.aspx. [Accessed 07JUN2013.].
  • 14
    • 84901613850 scopus 로고    scopus 로고
    • International Laboratory Accreditation Cooperation, 7 Leeds Street, Rhodes, NSW, Australia 2138, International Laboratory Accreditation Cooperation
    • International Laboratory Accreditation Cooperation Policy on traceability of measurement results - ILAC P-10 2002, International Laboratory Accreditation Cooperation, 7 Leeds Street, Rhodes, NSW, Australia 2138.
    • (2002) Policy on traceability of measurement results - ILAC P-10
  • 17
    • 84882277889 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute, 950 West Valley Road, Suite 2500, Wayne, Pennsylvania 19087 USA, Clinical and Laboratory Standards Institute (CLSI)
    • Clinical and Laboratory Standards Institute (CLSI) Expression of measurement uncertainty in laboratory medicine approved guideline. CLSI document EP29-A 2012, Clinical and Laboratory Standards Institute, 950 West Valley Road, Suite 2500, Wayne, Pennsylvania 19087 USA.
    • (2012) Expression of measurement uncertainty in laboratory medicine approved guideline. CLSI document EP29-A
  • 23
    • 84901613848 scopus 로고    scopus 로고
    • Available from, [Accessed 21SEP2013], WHO International Biological Reference Preparations
    • WHO International Biological Reference Preparations Available from, [Accessed 21SEP2013]. http://www.who.int/bloodproducts/catalogue/SafeFeb2013.pdf.
  • 24
    • 23044467768 scopus 로고    scopus 로고
    • Both core and terminal glycosylation alter epitope expression in thyrotropin and introduce discordances in hormone measurements
    • Donadio S., Morelle W., Pascual A., Romi-Lebrun R., Michalski J.C., Ronin C. Both core and terminal glycosylation alter epitope expression in thyrotropin and introduce discordances in hormone measurements. Clin Chem Lab Med 2005, 43:519-530.
    • (2005) Clin Chem Lab Med , vol.43 , pp. 519-530
    • Donadio, S.1    Morelle, W.2    Pascual, A.3    Romi-Lebrun, R.4    Michalski, J.C.5    Ronin, C.6
  • 25
    • 68149169590 scopus 로고    scopus 로고
    • Differences in recognition of the 1st WHO international reference reagents for hCG-related isoforms by diagnostic immunoassays for human chorionic gonadotropin
    • Sturgeon C.M., Berger P., Bidart J.M., Birken S., Burns C., Norman R.J., et al. Differences in recognition of the 1st WHO international reference reagents for hCG-related isoforms by diagnostic immunoassays for human chorionic gonadotropin. Clin Chem 2009, 55:1484-1491.
    • (2009) Clin Chem , vol.55 , pp. 1484-1491
    • Sturgeon, C.M.1    Berger, P.2    Bidart, J.M.3    Birken, S.4    Burns, C.5    Norman, R.J.6
  • 26
    • 84901613849 scopus 로고    scopus 로고
    • Available from, [accessed 17SEP2013], Oxford Online Dictionary of American English
    • Oxford Online Dictionary of American English Available from, [accessed 17SEP2013]. http://oxforddictionaries.com/us/definition/american_english/harmonize.
  • 27
    • 77953009117 scopus 로고    scopus 로고
    • Report of the IFCC working group for standardization of thyroid function tests, part 1: thyroid-stimulating hormone
    • Thienpont L.M., Van Uytfanghe K., Beastall G., Faix J.D., Ieiri T., Miller W.G., et al. Report of the IFCC working group for standardization of thyroid function tests, part 1: thyroid-stimulating hormone. Clin Chem 2010, 56:902-911.
    • (2010) Clin Chem , vol.56 , pp. 902-911
    • Thienpont, L.M.1    Van Uytfanghe, K.2    Beastall, G.3    Faix, J.D.4    Ieiri, T.5    Miller, W.G.6
  • 28
    • 84877744505 scopus 로고    scopus 로고
    • Harmonization of immunoassays to the all-procedure trimmed mean - proof of concept by use of data from the insulin standardization project
    • Van Houcke S.K., Van Aelst S., Van Uytfanghe K., Thienpont L.M. Harmonization of immunoassays to the all-procedure trimmed mean - proof of concept by use of data from the insulin standardization project. Clin Chem Lab Med May 2013, 51(5):e103-e105. 10.1515/cclm-2012-0661.
    • (2013) Clin Chem Lab Med , vol.51 , Issue.5
    • Van Houcke, S.K.1    Van Aelst, S.2    Van Uytfanghe, K.3    Thienpont, L.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.