메뉴 건너뛰기




Volumn 38, Issue 3, 2014, Pages 451-456

Multidetector-row computed tomography allows accurate measurement of mechanical prosthetic heart valve leaflet closing angles compared with fluoroscopy

Author keywords

cardiac imaging; computed tomography; fluoroscopy; prosthetic heart valves

Indexed keywords

FLUORESCENT SCREENS; MULTIDETECTOR COMPUTED TOMOGRAPHY; VALVES (MECHANICAL);

EID: 84901508876     PISSN: 03638715     EISSN: 15323145     Source Type: Journal    
DOI: 10.1097/RCT.0b013e3182ab5f15     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 0027957312 scopus 로고
    • Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses
    • Cannegieter SC, Rosendaal FR, Briet E. Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses. Circulation. 1994;89:635-641.
    • (1994) Circulation. , vol.89 , pp. 635-641
    • Cannegieter, S.C.1    Rosendaal, F.R.2    Briet, E.3
  • 3
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: A report from the American Society of Echocardiography' Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association
    • the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography
    • Zoghbi WA, Chambers JB, Dumesnil JG, et al. Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography' Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography. J Am Soc Echocardiogr. 2009;22:975-1014.
    • (2009) J Am Soc Echocardiogr. , vol.22 , pp. 975-1014
    • Zoghbi, W.A.1    Chambers, J.B.2    Dumesnil, J.G.3
  • 4
    • 27744599350 scopus 로고    scopus 로고
    • Cinefluoroscopic assessment of mechanical disc prostheses: Its value as a complementary method to echocardiography
    • Cianciulli TE, Lax JA, Beck MA, et al. Cinefluoroscopic assessment of mechanical disc prostheses: its value as a complementary method to echocardiography. J Heart Valve Dis. 2005;14:664-673.
    • (2005) J Heart Valve Dis. , vol.14 , pp. 664-673
    • Cianciulli, T.E.1    Lax, J.A.2    Beck, M.A.3
  • 5
    • 0029894155 scopus 로고    scopus 로고
    • Fluoroscopic functional evaluation of bileaflet prostheses: Effect of different intraoperative valve orientation
    • Montorsi P, Arena V, Muratori M, et al. Fluoroscopic functional evaluation of bileaflet prostheses: effect of different intraoperative valve orientation. Am J Card Imaging. 1996;10:101-107.
    • (1996) Am J Card Imaging. , vol.10 , pp. 101-107
    • Montorsi, P.1    Arena, V.2    Muratori, M.3
  • 6
    • 70349498637 scopus 로고    scopus 로고
    • Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction
    • Symersky P, Budde RP, de Mol BA, et al. Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction. Am J Cardiol. 2009;104:1128-1134.
    • (2009) Am J Cardiol. , vol.104 , pp. 1128-1134
    • Symersky, P.1    Budde, R.P.2    De Mol, B.A.3
  • 7
    • 79957734869 scopus 로고    scopus 로고
    • Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves
    • Symersky P, Budde RP, Prokop M, et al. Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves. J Heart Valve Dis. 2011;20:216-222.
    • (2011) J Heart Valve Dis. , vol.20 , pp. 216-222
    • Symersky, P.1    Budde, R.P.2    Prokop, M.3
  • 8
    • 62649154662 scopus 로고    scopus 로고
    • Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard
    • Tsai IC, Lin YK, Chang Y, et al. Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard. Eur Radiol. 2009;19:857-867.
    • (2009) Eur Radiol. , vol.19 , pp. 857-867
    • Tsai, I.C.1    Lin, Y.K.2    Chang, Y.3
  • 9
    • 0442323707 scopus 로고    scopus 로고
    • Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation
    • Teshima H, Hayashida N, Fukunaga S, et al. Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation. Ann Thorac Surg. 2004;77:523-526.
    • (2004) Ann Thorac Surg. , vol.77 , pp. 523-526
    • Teshima, H.1    Hayashida, N.2    Fukunaga, S.3
  • 10
    • 79960966500 scopus 로고    scopus 로고
    • Diagnostic evaluation of left-sided prosthetic heart valve dysfunction
    • Habets J, Budde RP, Symersky P, et al. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction. Nat Rev Cardiol. 2011;8:466-478.
    • (2011) Nat Rev Cardiol. , vol.8 , pp. 466-478
    • Habets, J.1    Budde, R.P.2    Symersky, P.3
  • 11
    • 46849120417 scopus 로고    scopus 로고
    • The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: Initial experience
    • Konen E, Goitein O, Feinberg MS, et al. The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: initial experience. AJR Am J Roentgenol. 2008;191:26-31.
    • (2008) AJR Am J Roentgenol. , vol.191 , pp. 26-31
    • Konen, E.1    Goitein, O.2    Feinberg, M.S.3
  • 12
    • 79959379991 scopus 로고    scopus 로고
    • Prosthetic heart valve assessment with multidetector-row CT: Imaging characteristics of 91 valves in 83 patients
    • Habets J, Symersky P, van Herwerden LA, et al. Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients. Eur Radiol. 2011;21:1390-1396.
    • (2011) Eur Radiol. , vol.21 , pp. 1390-1396
    • Habets, J.1    Symersky, P.2    Van Herwerden, L.A.3
  • 13
    • 84867283287 scopus 로고    scopus 로고
    • Guidelines on the management of valvular heart disease (version 2012)
    • Vahanian A, Alfieri O, Andreotti F, et al. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J. 2012;33:2451-2496.
    • (2012) Eur Heart J. , vol.33 , pp. 2451-2496
    • Vahanian, A.1    Alfieri, O.2    Andreotti, F.3
  • 14
    • 84892911649 scopus 로고    scopus 로고
    • Differentiation of thrombus from pannus as the cause of acquired mechanical prosthetic heart valve obstruction by non-invasive imaging: A review of the literature
    • [Epub ahead of print]
    • Tanis W, Habets J, van den Brink RB, et al. Differentiation of thrombus from pannus as the cause of acquired mechanical prosthetic heart valve obstruction by non-invasive imaging: a review of the literature. Eur Heart J Cardiovasc Imaging. 2013. [Epub ahead of print].
    • (2013) Eur Heart J Cardiovasc Imaging.
    • Tanis, W.1    Habets, J.2    Van Den Brink, R.B.3
  • 15
    • 84860607088 scopus 로고    scopus 로고
    • Low radiation dose non-contrast cardiac CT: Is it of value in the evaluation of mechanical aortic valve
    • Bazeed MF, Moselhy MS, Rezk AI, et al. Low radiation dose non-contrast cardiac CT: is it of value in the evaluation of mechanical aortic valve. Acta Radiol. 2012;53:389-393.
    • (2012) Acta Radiol. , vol.53 , pp. 389-393
    • Bazeed, M.F.1    Moselhy, M.S.2    Rezk, A.I.3
  • 16
    • 70449481805 scopus 로고    scopus 로고
    • Evaluation of mechanical heart valve size and function with ECG-gated 64-MDCT
    • LaBounty TM, Agarwal PP, Chughtai A, et al. Evaluation of mechanical heart valve size and function with ECG-gated 64-MDCT. AJR Am J Roentgenol. 2009;193:W389-W396.
    • (2009) AJR Am J Roentgenol. , vol.193
    • Labounty, T.M.1    Agarwal, P.P.2    Chughtai, A.3
  • 17
    • 65649130499 scopus 로고    scopus 로고
    • The measurement of opening angle and orifice area of a bileaflet mechanical valve using multidetector computed tomography
    • Lee DH, Youn HJ, Shim SB, et al. The measurement of opening angle and orifice area of a bileaflet mechanical valve using multidetector computed tomography. Korean Circ J. 2009;39:157-162.
    • (2009) Korean Circ J. , vol.39 , pp. 157-162
    • Lee, D.H.1    Youn, H.J.2    Shim, S.B.3