메뉴 건너뛰기




Volumn 9, Issue 5, 2014, Pages

Catheterless long-term ambulatory urodynamic measurement using a novel three-device system

Author keywords

[No Author keywords available]

Indexed keywords

ALARM PAD DEVICE; ANIMAL CELL; ARTICLE; BIOCOMPATIBILITY; CONTROLLED STUDY; CYSTOSCOPE; CYTOTOXICITY TEST; EQUIPMENT DESIGN; IN VITRO STUDY; INTRAVESICAL CAPSULE; MEDICAL DEVICE; MICROCOMPUTER; MICROCONTROLLER; MICTURITION; MODEL; MOUSE; NONHUMAN; URODYNAMICS; URODYNAMICS SYSTEM; UROLOGICAL EQUIPMENT; AMBULATORY CARE; BLADDER; FEMALE; HUMAN; OVERACTIVE BLADDER; PATHOPHYSIOLOGY; PHYSIOLOGY;

EID: 84901338085     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0096280     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 0344235173 scopus 로고    scopus 로고
    • Describing bladder storage function: Overactive bladder syndrome and detrusor overactivity
    • Abrams P (2003) Describing bladder storage function: overactive bladder syndrome and detrusor overactivity. Urology 62: 28-37.
    • (2003) Urology , vol.62 , pp. 28-37
    • Abrams, P.1
  • 3
    • 28344446202 scopus 로고    scopus 로고
    • Is the bladder a reliable witness for predicting detrusor overactivity?
    • DOI 10.1016/S0022-5347(05)00067-4, PII S0022534705000674
    • Hashim H, Abrams P (2006) Is the bladder a reliable witness for predicting detrusor overactivity? J.Urol. 175: 191-194. (Pubitemid 41797136)
    • (2006) Journal of Urology , vol.175 , Issue.1 , pp. 191-194
    • Hashim, H.1    Abrams, P.2
  • 4
    • 0036357644 scopus 로고    scopus 로고
    • Transponder system for non-invasive measurement of intravascular pressure
    • Schnakenberg U, Kruger C, Pfeffer JG, Mokwa W, von Bogel G, et al. (2002) Transponder system for non-invasive measurement of intravascular pressure. Biomed.Tech.(Berl) 47 Suppl 1 Pt 1: 191-193.
    • (2002) Biomed.Tech.(Berl) , vol.47 , Issue.SUPPL. 1 PART 1 , pp. 191-193
    • Schnakenberg, U.1    Kruger, C.2    Pfeffer, J.G.3    Mokwa, W.4    Von Bogel, G.5
  • 7
    • 84876047285 scopus 로고    scopus 로고
    • A System for Long-term Urodynamic Studies Without Catheters
    • Wille S, Tenholte D, Engelmann U (2013) A System for Long-term Urodynamic Studies Without Catheters. Eur.Urol. 63: 966-968.
    • (2013) Eur.Urol. , vol.63 , pp. 966-968
    • Wille, S.1    Tenholte, D.2    Engelmann, U.3
  • 8
    • 51449091963 scopus 로고    scopus 로고
    • The importance of Good Clinical Practice guidelines and its role in clinical trials
    • Vijayananthan A, Nawawi O (2008) The importance of Good Clinical Practice guidelines and its role in clinical trials. Biomed.Imaging Interv.J. 4: 5-7.
    • (2008) Biomed.Imaging Interv.J. , vol.4 , pp. 5-7
    • Vijayananthan, A.1    Nawawi, O.2
  • 9
    • 77957155419 scopus 로고    scopus 로고
    • The BladderPill: An in-body system logg ing bladder pressure
    • Jourand P, Puers R (2010) The BladderPill: An in-body system logg ing bladder pressure. Sensors and Actuators A 162: 160-166.
    • (2010) Sensors and Actuators a , vol.162 , pp. 160-166
    • Jourand, P.1    Puers, R.2
  • 11
    • 0035160698 scopus 로고    scopus 로고
    • Conventional and ambulatory urodynamic findings in women with symptoms suggestive of bladder overactivity
    • Radley SC, Rosario DJ, Chapple CR, Farkas AG (2001) Conventional and ambulatory urodynamic findings in women with symptoms suggestive of bladder overactivity. J.Urol. 166: 2253-2258. (Pubitemid 33065268)
    • (2001) Journal of Urology , vol.166 , Issue.6 , pp. 2253-2258
    • Radley, S.C.1    Rosario, D.J.2    Chapple, C.R.3    Farkas, A.G.4
  • 15
    • 0033663829 scopus 로고    scopus 로고
    • Selection of a polyurethane membrane for the manufacture of ventricles for a totally implantable artificial heart: Blood compatibility and biocompatibility studies
    • Belanger MC, Marois Y, Roy R, Mehri Y, Wagner E, et al. (2000) Selection of a polyurethane membrane for the manufacture of ventricles for a totally implantable artificial heart: blood compatibility and biocompatibility studies. Artif.Organs 24: 879-888.
    • (2000) Artif.Organs , vol.24 , pp. 879-888
    • Belanger, M.C.1    Marois, Y.2    Roy, R.3    Mehri, Y.4    Wagner, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.