메뉴 건너뛰기




Volumn 200, Issue , 2014, Pages 173-180

ZnO nanorod matrix based electrochemical immunosensors for sensitivity enhanced detection of Legionella pneumophila

Author keywords

Electrochemistry; Immunosensor; Legionella pneumophila; Nanorods; Zinc oxide

Indexed keywords

ANTIBODIES; ANTIGENS; CYCLIC VOLTAMMETRY; ELECTROCHEMISTRY; FABRICATION; IMMUNOSENSORS; NANORODS; ZINC OXIDE;

EID: 84900868622     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.03.001     Document Type: Article
Times cited : (31)

References (31)
  • 1
    • 0036314980 scopus 로고    scopus 로고
    • Legionella and legionnaires' disease: 25 Years of investigation
    • DOI 10.1128/CMR.15.3.506-526.2002
    • B.S. Fields, R.F. Benson, and R.E. Besser Legionella and Legionnaires' disease: 25 years of investigation Clin. Microbiol. Rev. 15 2002 506 526 (Pubitemid 34761355)
    • (2002) Clinical Microbiology Reviews , vol.15 , Issue.3 , pp. 506-526
    • Fields, B.S.1    Benson, R.F.2    Besser, R.E.3
  • 3
    • 0029557521 scopus 로고
    • Antimicrobial chemotherapy for Legionnaires' disease: A review
    • P.H. Edelstein Antimicrobial chemotherapy for Legionnaires' disease: a review Clin. Infect. Dis. 21 1995 S76 S265
    • (1995) Clin. Infect. Dis. , vol.21
    • Edelstein, P.H.1
  • 4
    • 0034751084 scopus 로고    scopus 로고
    • The impact of diagnosis by legionella urinary antigen test on the epidemiology and outcomes of Legionnaires' disease
    • N. Formica, M. Yates, M. Beers, J. Carnie, G. Hogg, and N. Ryan et al. The impact of diagnosis by legionella urinary antigen test on the epidemiology and outcomes of Legionnaires' disease Epidemiol. Infect. 127 2001 275 280 (Pubitemid 33019539)
    • (2001) Epidemiology and Infection , vol.127 , Issue.2 , pp. 275-280
    • Formica, N.1    Yates, M.2    Beers, M.3    Carnie, J.4    Hogg, G.5    Ryan, N.6    Tallis, G.7
  • 5
    • 0018898448 scopus 로고
    • An outbreak of Legionnaires' disease associated with a contaminated air-conditioning cooling tower
    • T.J. Dondero, R.C. Rendtorff, G.F. Mallison, R.M. Weeks, J.S. Levy, and E.W. Wong et al. An outbreak of Legionnaires' disease associated with a contaminated air-conditioning cooling tower New Engl. J. Med. 302 1980 365 370 (Pubitemid 10166812)
    • (1980) New England Journal of Medicine , vol.302 , Issue.7 , pp. 365-370
    • Dondero Jr., T.J.1    Rendtorff, R.C.2    Mallison, G.F.3
  • 6
    • 33748150435 scopus 로고    scopus 로고
    • Microfluidic enzyme-linked immunosorbent assay technology
    • DOI 10.1016/S0065-2423(06)42007-2, PII S0065242306420072
    • L.J. Lee, S. Yang, S. Lai, Y. Bai, W. Huang, and Y. Juang Microfluidic enzyme-linked immunosorbent assay technology S.M. Gregory, Advances in Clinical Chemistry 2006 Elsevier Amsterdam 255 295 (Pubitemid 44314137)
    • (2006) Advances in Clinical Chemistry , vol.42 , pp. 255-295
    • Lee, L.J.1    Yang, S.2    Lai, S.3    Bai, Y.4    Huang, W.5    Juang, Y.6
  • 7
    • 48949105565 scopus 로고    scopus 로고
    • Part-per-trillion level detection of estradiol by competitive fluorescence immunoassay using DNA/dye conjugate as antibody multiple labels
    • S. Zhu, Q. Zhang, and L.-H. Guo Part-per-trillion level detection of estradiol by competitive fluorescence immunoassay using DNA/dye conjugate as antibody multiple labels Anal. Chim. Acta 624 2008 141 146
    • (2008) Anal. Chim. Acta , vol.624 , pp. 141-146
    • Zhu, S.1    Zhang, Q.2    Guo, L.-H.3
  • 8
    • 0035171117 scopus 로고    scopus 로고
    • Comparison of chemiluminescent assays and colorimetric ELISAs for quantification of murine IL-12, human IL-4 and murine IL-4: Chemiluminescent substrates provide markedly enhanced sensitivity
    • DOI 10.1016/S0022-1759(00)00306-9, PII S0022175900003069
    • I.P. Lewkowich, J.D. Campbell, and K.T. HayGlass Comparison of chemiluminescent assays and colorimetric ELISAs for quantification of murine IL-12, human IL-4 and murine IL-4: chemiluminescent substrates provide markedly enhanced sensitivity J. Immunol. Methods 247 2001 111 118 (Pubitemid 32057049)
    • (2001) Journal of Immunological Methods , vol.247 , Issue.1-2 , pp. 111-118
    • Lewkowich, I.P.1    Campbell, J.D.2    HayGlass, K.T.3
  • 9
    • 38949214690 scopus 로고    scopus 로고
    • Scalable fabrication of immunosensors based on carbon nanotube polymer composites
    • M. Ernest et al. Scalable fabrication of immunosensors based on carbon nanotube polymer composites Nanotechnology 19 2008 075102
    • (2008) Nanotechnology , vol.19 , pp. 075102
    • Ernest, M.1
  • 10
    • 56249130728 scopus 로고    scopus 로고
    • Sensitive amperometric immunosensor for α-fetoprotein based on carbon nanotube/gold nanoparticle doped chitosan film
    • J. Lin, C. He, L. Zhang, and S. Zhang Sensitive amperometric immunosensor for α-fetoprotein based on carbon nanotube/gold nanoparticle doped chitosan film Anal. Biochem. 384 2009 130 135
    • (2009) Anal. Biochem. , vol.384 , pp. 130-135
    • Lin, J.1    He, C.2    Zhang, L.3    Zhang, S.4
  • 11
    • 67549125649 scopus 로고    scopus 로고
    • A novel electrochemical immunosensor based on ordered Au nano-prickle clusters
    • S. Wang, Z. Wu, F. Qu, S. Zhang, G. Shen, and R. Yu A novel electrochemical immunosensor based on ordered Au nano-prickle clusters Biosens. Bioelectron. 24 2008 1020 1026
    • (2008) Biosens. Bioelectron. , vol.24 , pp. 1020-1026
    • Wang, S.1    Wu, Z.2    Qu, F.3    Zhang, S.4    Shen, G.5    Yu, R.6
  • 12
    • 42649142901 scopus 로고    scopus 로고
    • A reagentless amperometric immunosensor for α-1-fetoprotein based on gold nanowires and ZnO NRs modified electrode
    • X. Lu, H. Bai, P. He, Y. Cha, G. Yang, and L. Tan et al. A reagentless amperometric immunosensor for α-1-fetoprotein based on gold nanowires and ZnO NRs modified electrode Anal. Chim. Acta 615 2008 158 164
    • (2008) Anal. Chim. Acta , vol.615 , pp. 158-164
    • Lu, X.1    Bai, H.2    He, P.3    Cha, Y.4    Yang, G.5    Tan, L.6
  • 13
    • 0345059088 scopus 로고    scopus 로고
    • Immunological assay for carbohydrate antigen 19-9 using an electrochemical immunosensor and antigen immobilization in titania sol-gel matrix
    • DOI 10.1016/j.jim.2003.08.014
    • D. Du, F. Yan, S. Liu, and H. Ju Immunological assay for carbohydrate antigen 19-9 using an electrochemical immunosensor and antigen immobilization in titania sol-gel matrix J. Immunol. Methods 283 2003 67 75 (Pubitemid 37501059)
    • (2003) Journal of Immunological Methods , vol.283 , Issue.1-2 , pp. 67-75
    • Du, D.1    Yan, F.2    Liu, S.3    Ju, H.4
  • 14
    • 61349167143 scopus 로고    scopus 로고
    • Cellular level biocompatibility and biosafety of ZnO nanowires
    • Z. Li, R. Yang, M. Yu, F. Bai, C. Li, and Z.L. Wang Cellular level biocompatibility and biosafety of ZnO nanowires J. Phys. Chem. C 112 2008 20114 20117
    • (2008) J. Phys. Chem. C , vol.112 , pp. 20114-20117
    • Li, Z.1    Yang, R.2    Yu, M.3    Bai, F.4    Li, C.5    Wang, Z.L.6
  • 15
    • 58749090170 scopus 로고    scopus 로고
    • Highly-sensitive cholesterol biosensor based on well-crystallized flower-shaped ZnO nanostructures
    • A. Umar, M.M. Rahman, A. Al-Hajry, and Y.B. Hahn Highly-sensitive cholesterol biosensor based on well-crystallized flower-shaped ZnO nanostructures Talanta 78 2009 284 289
    • (2009) Talanta , vol.78 , pp. 284-289
    • Umar, A.1    Rahman, M.M.2    Al-Hajry, A.3    Hahn, Y.B.4
  • 16
    • 84865112839 scopus 로고    scopus 로고
    • Immunosensor based on the ZnO NR networks for the detection of H1N1 swine influenza virus
    • Y. Jang, J. Park, Y.K. Pak, and J.J. Pak Immunosensor based on the ZnO NR networks for the detection of H1N1 swine influenza virus J. Nanosci. Nanotechnol. 12 2012 5173 5177
    • (2012) J. Nanosci. Nanotechnol. , vol.12 , pp. 5173-5177
    • Jang, Y.1    Park, J.2    Pak, Y.K.3    Pak, J.J.4
  • 17
    • 71549162876 scopus 로고    scopus 로고
    • Preparation and characterization of copper nanoparticles/zinc oxide composite modified electrode and its application to glucose sensing
    • S.A. Kumar, H.-W. Cheng, S.-M. Chen, and S.-F. Wang Preparation and characterization of copper nanoparticles/zinc oxide composite modified electrode and its application to glucose sensing Mater. Sci. Eng. C 30 2010 86 91
    • (2010) Mater. Sci. Eng. C , vol.30 , pp. 86-91
    • Kumar, S.A.1    Cheng, H.-W.2    Chen, S.-M.3    Wang, S.-F.4
  • 18
    • 71549173402 scopus 로고    scopus 로고
    • Zinc oxide-potassium ferricyanide composite thin film matrix for biosensing applications
    • S. Saha, S.K. Arya, S.P. Singh, K. Sreenivas, B.D. Malhotra, and V. Gupta Zinc oxide-potassium ferricyanide composite thin film matrix for biosensing applications Anal. Chim. Acta 653 2009 212 216
    • (2009) Anal. Chim. Acta , vol.653 , pp. 212-216
    • Saha, S.1    Arya, S.K.2    Singh, S.P.3    Sreenivas, K.4    Malhotra, B.D.5    Gupta, V.6
  • 19
    • 0037830702 scopus 로고    scopus 로고
    • Characterization of a lipoprotein common to legionella species as a urinary broad-spectrum antigen for diagnosis of Legionnaires' disease
    • M.J. Kim, J.W. Sohn, D.W. Park, S.C. Park, B.C. Chun, and M.J. Kim et al. Characterization of a lipoprotein common to legionella species as a urinary broad-spectrum antigen for diagnosis of Legionnaires' disease J. Clin. Microbiol. 41 2003 2974
    • (2003) J. Clin. Microbiol. , vol.41 , pp. 2974
    • Kim, M.J.1    Sohn, J.W.2    Park, D.W.3    Park, S.C.4    Chun, B.C.5    Kim, M.J.6
  • 21
    • 0026022242 scopus 로고
    • Chlamydia trachomatis contains a protein similar to the Legionella pneumophila mip gene product
    • A.G. Lundemose, S. Birkelund, S.J. Fey, P.M. Larsen, and G. Christiansen Chlamydia trachomatis contains a protein similar to the Legionella pneumophila mip gene product Mol. Microbiol. 5 1991 109 115 (Pubitemid 21895946)
    • (1991) Molecular Microbiology , vol.5 , Issue.1 , pp. 109-115
    • Lundemose, A.G.1    Birkelund, S.2    Fey, S.J.3    Mose Larsen, P.4    Christiansen, G.5
  • 24
    • 34047142649 scopus 로고    scopus 로고
    • Development of a novel electrochemical immuno-assay using a screen printed electrode for the determination of secretory immunoglobulin A in human sweat
    • DOI 10.1016/j.electacta.2007.02.035, PII S0013468607002800
    • A. Crew, C. Alford, D.C.C. Cowell, and J.P. Hart Development of a novel electrochemical immuno-assay using a screen printed electrode for the determination of secretory immunoglobulin A in human sweat Electrochim. Acta 52 2007 5232 5237 (Pubitemid 46517552)
    • (2007) Electrochimica Acta , vol.52 , Issue.16 , pp. 5232-5237
    • Crew, A.1    Alford, C.2    Cowell, D.C.C.3    Hart, J.P.4
  • 25
    • 0020478887 scopus 로고
    • The horseradish peroxidase-catalyzed oxidation of 3,5,3',5'- tetramethylbenzidine. Free radical and charge-transfer complex intermediates
    • P.D. Josephy, T. Eling, and R.P. Mason The horseradish peroxidase-catalyzed oxidation of 3,5,3',5'-tetramethylbenzidine. Free radical and charge-transfer complex intermediates J. Biol. Chem. 257 1982 3669 3675
    • (1982) J. Biol. Chem. , vol.257 , pp. 3669-3675
    • Josephy, P.D.1    Eling, T.2    Mason, R.P.3
  • 26
    • 77956873384 scopus 로고    scopus 로고
    • Thermo-electrochemical selective growth of ZnO nanorods on any noble metal electrodes
    • X. You, J. Park, J.-h. Choi, and J.J. Pak Thermo-electrochemical selective growth of ZnO nanorods on any noble metal electrodes Superlattices Microstruct. 48 2010 365 372
    • (2010) Superlattices Microstruct. , vol.48 , pp. 365-372
    • You, X.1    Park, J.2    Choi, J.-H.3    Pak, J.J.4
  • 27
    • 80755148580 scopus 로고    scopus 로고
    • Microbiosensors based on DNA modified single-walled carbon nanotube and Pt black nanocomposites
    • J. Shi, T.-G. Cha, J.C. Claussen, A.R. Diggs, J.H. Choi, and D.M. Porterfield Microbiosensors based on DNA modified single-walled carbon nanotube and Pt black nanocomposites Analyst 136 2011 4916 4924
    • (2011) Analyst , vol.136 , pp. 4916-4924
    • Shi, J.1    Cha, T.-G.2    Claussen, J.C.3    Diggs, A.R.4    Choi, J.H.5    Porterfield, D.M.6
  • 28
    • 84856368458 scopus 로고    scopus 로고
    • A comparative study of enzyme immobilization strategies for multi-walled carbon nanotube glucose biosensors
    • S. Jin, C.C. Jonathan, S.M. Eric, H. Aeraj ul, J. David, and R.D. Alfred et al. A comparative study of enzyme immobilization strategies for multi-walled carbon nanotube glucose biosensors Nanotechnology 22 2011 355502
    • (2011) Nanotechnology , vol.22 , pp. 355502
    • Jin, S.1    Jonathan, C.C.2    Eric, S.M.3    Aeraj Ul, H.4    David, J.5    Alfred, R.D.6
  • 29
    • 0030918869 scopus 로고    scopus 로고
    • Development of an 'electrically wired' amperometric immunosensor for the determination of biotin based on a non-diffusional redolx osmium polymer film containing an antibody to the enzyme label horseradish peroxidase
    • DOI 10.1016/S0003-2670(97)00083-4, PII S0003267097000834
    • B. Lu, E.I. Iwuoha, M.R. Smyth, and R. O'Kennedy Development of an electrically wired amperometric immunosensor for the determination of biotin based on a non-diffusional redox osmium polymer film containing an antibody to the enzyme label horseradish peroxidase Anal. Chim. Acta 345 1997 59 66 (Pubitemid 27273962)
    • (1997) Analytica Chimica Acta , vol.345 , Issue.1-3 , pp. 59-66
    • Lu, B.1    Iwuoha, E.I.2    Smyth, M.R.3    O'Kennedy, R.4
  • 30
    • 33846470447 scopus 로고    scopus 로고
    • Reagentless amperometric carbohydrate antigen 19-9 immunosensor based on direct electrochemistry of immobilized horseradish peroxidase
    • DOI 10.1016/j.talanta.2006.06.028, PII S0039914006004620
    • D. Du, X. Xu, S. Wang, and A. Zhang Reagentless amperometric carbohydrate antigen 19-9 immunosensor based on direct electrochemistry of immobilized horseradish peroxidase Talanta 71 2007 1257 1262 (Pubitemid 46161647)
    • (2007) Talanta , vol.71 , Issue.3 , pp. 1257-1262
    • Du, D.1    Xu, X.2    Wang, S.3    Zhang, A.4
  • 31
    • 84859899490 scopus 로고    scopus 로고
    • Plasma-activated carbon nanotube-based high sensitivity immunosensors for monitoring Legionella pneumophila by direct detection of maltose binding protein peptidoglycan-associated lipoprotein (MBP-PAL)
    • J.-Y. Lee, J.-H. Jin, J.H. Kim, M.J. Kim, C.J. Lee, and N.K. Min Plasma-activated carbon nanotube-based high sensitivity immunosensors for monitoring Legionella pneumophila by direct detection of maltose binding protein peptidoglycan-associated lipoprotein (MBP-PAL) Biotechnol. Bioeng. 109 2012 1471 1478
    • (2012) Biotechnol. Bioeng. , vol.109 , pp. 1471-1478
    • Lee, J.-Y.1    Jin, J.-H.2    Kim, J.H.3    Kim, M.J.4    Lee, C.J.5    Min, N.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.