메뉴 건너뛰기




Volumn 71, Issue 6, 2014, Pages 2043-2050

Near-contiguous spin echo imaging using matched-phase RF and its application in velocity-selective arterial spin labeling

Author keywords

arterial spin labeling; cerebral blood flow; matched phase RF; VSASL

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; CROSSTALK; HEMODYNAMICS; IMAGE ENHANCEMENT; MAGNETIZATION; SIGNAL TO NOISE RATIO; SPIN POLARIZATION; STATISTICS; VELOCITY;

EID: 84900790891     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24866     Document Type: Article
Times cited : (8)

References (21)
  • 2
    • 0022612357 scopus 로고
    • Effect of intersection spacing on MR image contrast and study time
    • Kneeland JB, Shimakawa A, Wehrli FW,. Effect of intersection spacing on MR image contrast and study time. Radiology 1986; 158: 819-822.
    • (1986) Radiology , vol.158 , pp. 819-822
    • Kneeland, J.B.1    Shimakawa, A.2    Wehrli, F.W.3
  • 3
    • 0028339167 scopus 로고
    • Sources of intensity nonuniformity in spin echo images at 1.5 T
    • Simmons A, Tofts PS, Barker GJ, Arridge SR,. Sources of intensity nonuniformity in spin echo images at 1.5 T. Magn Reson Med 1994; 32: 121-128.
    • (1994) Magn Reson Med , vol.32 , pp. 121-128
    • Simmons, A.1    Tofts, P.S.2    Barker, G.J.3    Arridge, S.R.4
  • 4
    • 0022340787 scopus 로고
    • Multisection-multiecho MR imaging: Effect on image quality
    • Fitzsimmons JR, Googe RE,. Multisection-multiecho MR imaging: effect on image quality. Radiology 1985; 157: 813-814.
    • (1985) Radiology , vol.157 , pp. 813-814
    • Fitzsimmons, J.R.1    Googe, R.E.2
  • 6
    • 0024501536 scopus 로고
    • Contrast and accuracy of relaxation time measurements in acquired and synthesized multislice magnetic resonance images
    • Majumdar S, Sostman HD, MacFall JR,. Contrast and accuracy of relaxation time measurements in acquired and synthesized multislice magnetic resonance images. Invest Radiology 1989; 24: 119-127.
    • (1989) Invest Radiology , vol.24 , pp. 119-127
    • Majumdar, S.1    Sostman, H.D.2    Macfall, J.R.3
  • 7
    • 0023818807 scopus 로고
    • Errors in T1-determination using multislice technique and Gaussian slice profiles
    • Just M, Higer HP, Pfannenstiel P,. Errors in T1-determination using multislice technique and Gaussian slice profiles. Magn Reson Imaging 1988; 6: 53-56.
    • (1988) Magn Reson Imaging , vol.6 , pp. 53-56
    • Just, M.1    Higer, H.P.2    Pfannenstiel, P.3
  • 8
    • 34547762645 scopus 로고    scopus 로고
    • Effect of multislice acquisition on T1 and T2 measurements of articular cartilage at 3T
    • Watanabe A, Boesch C, Obata T, Anderson SE,. Effect of multislice acquisition on T1 and T2 measurements of articular cartilage at 3T. J Magn Reson Imaging 2007; 26: 109-117.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 109-117
    • Watanabe, A.1    Boesch, C.2    Obata, T.3    Anderson, S.E.4
  • 9
    • 0023943160 scopus 로고
    • Effect of multislice interference on image contrast in T2- and T1-weighted MR images
    • Kucharczyk W, Crawley AP, Kelly WM, Henkelman RM,. Effect of multislice interference on image contrast in T2- and T1-weighted MR images. AJNR Am J Neuroradiol 1988; 9: 443-451.
    • (1988) AJNR Am J Neuroradiol , vol.9 , pp. 443-451
    • Kucharczyk, W.1    Crawley, A.P.2    Kelly, W.M.3    Henkelman, R.M.4
  • 10
    • 0024353690 scopus 로고
    • Diagnostic significance of interslice gap and imaging volume in body MR imaging
    • Schwaighofer BW, Yu KK, Mattrey RF,. Diagnostic significance of interslice gap and imaging volume in body MR imaging. AJR Am J Roentgenol 1989; 153: 629-632.
    • (1989) AJR Am J Roentgenol , vol.153 , pp. 629-632
    • Schwaighofer, B.W.1    Yu, K.K.2    Mattrey, R.F.3
  • 11
  • 12
    • 23744476680 scopus 로고    scopus 로고
    • Optimization of sequences for MRI of the abdomen and pelvis
    • Lomas DJ,. Optimization of sequences for MRI of the abdomen and pelvis. Clin Radiol 1997; 52: 412-428.
    • (1997) Clin Radiol , vol.52 , pp. 412-428
    • Lomas, D.J.1
  • 14
    • 66649089515 scopus 로고    scopus 로고
    • Spin-echo T1-weighted imaging of the brain with interleaved acquisition and presaturation pulse at 3 T: A feasibility study before clinical use
    • Kasahara S, Miki Y, Mori N, Urayama S, Kanagaki M, Fushimi Y, Maeda C, Sawamoto N, Fukuyama H, Togashi K,. Spin-echo T1-weighted imaging of the brain with interleaved acquisition and presaturation pulse at 3 T: a feasibility study before clinical use. Acad Radiol 2009; 16: 852-857.
    • (2009) Acad Radiol , vol.16 , pp. 852-857
    • Kasahara, S.1    Miki, Y.2    Mori, N.3    Urayama, S.4    Kanagaki, M.5    Fushimi, Y.6    Maeda, C.7    Sawamoto, N.8    Fukuyama, H.9    Togashi, K.10
  • 15
    • 67650091979 scopus 로고    scopus 로고
    • Self-refocused spatial-spectral pulse for positive contrast imaging of cells labeled with SPIO nanoparticles
    • Balchandani P, Yamada M, Pauly J, Yang P, Spielman D,. Self-refocused spatial-spectral pulse for positive contrast imaging of cells labeled with SPIO nanoparticles. Magn Reson Med 2009; 62: 183-192.
    • (2009) Magn Reson Med , vol.62 , pp. 183-192
    • Balchandani, P.1    Yamada, M.2    Pauly, J.3    Yang, P.4    Spielman, D.5
  • 17
    • 12844263757 scopus 로고    scopus 로고
    • Non-linear phase RF pulses for reduced dynamic range in 3D RARE imaging
    • Glasgow, Scotland, UK
    • Pauly JM, Wong EC,. Non-linear phase RF pulses for reduced dynamic range in 3D RARE imaging. In Proceedings of the 9th Annual Meeting of ISMRM, Glasgow, Scotland, UK, 2001. p. 688.
    • (2001) Proceedings of the 9th Annual Meeting of ISMRM , pp. 688
    • Pauly, J.M.1    Wong, E.C.2
  • 18
    • 0028904155 scopus 로고
    • Pulses with fixed magnitude and variable phase response profiles
    • Pickup S, Ding X,. Pulses with fixed magnitude and variable phase response profiles. Magn Reson Med 1995; 33: 648-655.
    • (1995) Magn Reson Med , vol.33 , pp. 648-655
    • Pickup, S.1    Ding, X.2
  • 19
    • 33847534249 scopus 로고
    • Effects of diffusion on free precession in nuclear magnetic resonance experiments
    • Carr H, Purcell E,. Effects of diffusion on free precession in nuclear magnetic resonance experiments. Phys Rev 1954; 94: 630-638.
    • (1954) Phys Rev , vol.94 , pp. 630-638
    • Carr, H.1    Purcell, E.2
  • 20
    • 0002899752 scopus 로고
    • Modified spin-echo method for measuring nuclear relaxation times
    • Meiboom S, Gill S,. Modified spin-echo method for measuring nuclear relaxation times. Rev Sci Instr 1958; 29: 688-691.
    • (1958) Rev Sci Instr , vol.29 , pp. 688-691
    • Meiboom, S.1    Gill, S.2
  • 21
    • 84900827790 scopus 로고    scopus 로고
    • Pseudocontinuous arterial spin labeling with prospective motion correction (ASL-PROMO)
    • Amsterdam, The Netherlands
    • Zun Z, Shankaranarayanan A, Zaharchuk G,. Pseudocontinuous arterial spin labeling with prospective motion correction (ASL-PROMO). In ISMRM Workshop on Perfusion MRI, Amsterdam, The Netherlands, 2012. p. 31.
    • (2012) ISMRM Workshop on Perfusion MRI , pp. 31
    • Zun, Z.1    Shankaranarayanan, A.2    Zaharchuk, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.