메뉴 건너뛰기




Volumn 172, Issue 3, 2014, Pages

Clinical characteristics of atrial fibrillation detected by implanted devices and its association with ICD therapy

Author keywords

Atrial fibrillation; Implantable cardioverter defibrillator; Pacemaker

Indexed keywords

ADULT; AGED; CARDIOVASCULAR THERAPEUTIC DEVICE; DISEASE ASSOCIATION; FALSE NEGATIVE RESULT; FALSE POSITIVE RESULT; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HUMAN; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; LETTER; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SUPRAVENTRICULAR TACHYCARDIA; ATRIAL FIBRILLATION; ELECTROCARDIOGRAPHY; INCIDENCE; JAPAN; MIDDLE AGED; PROGNOSIS; REPRODUCIBILITY; TIME;

EID: 84900674015     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2014.01.067     Document Type: Article
Times cited : (18)

References (5)
  • 1
    • 0037382858 scopus 로고    scopus 로고
    • Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: Report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST)
    • T.V. Glotzer, A.S. Hellkamp, and J. Zimmerman et al. Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST) Circulation 107 2003 1614 1619
    • (2003) Circulation , vol.107 , pp. 1614-1619
    • Glotzer, T.V.1    Hellkamp, A.S.2    Zimmerman, J.3
  • 2
    • 0347228969 scopus 로고    scopus 로고
    • Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device: Implications for optimal patient care
    • C.W. Israel, G. Gronefeld, J.R. Ehrlich, Y.G. Li, and S.H. Hohnloser Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device: implications for optimal patient care J Am Coll Cardiol 43 2004 47 52
    • (2004) J Am Coll Cardiol , vol.43 , pp. 47-52
    • Israel, C.W.1    Gronefeld, G.2    Ehrlich, J.R.3    Li, Y.G.4    Hohnloser, S.H.5
  • 3
    • 0028113953 scopus 로고
    • Lessons learned from data logging in a multicenter clinical trial using a late-generation implantable cardioverter-defibrillator. The Guardian ATP 4210 Multicenter Investigators Group
    • M.A. Wood, B.S. Stambler, R.J. Damiano, P. Greenway, and K.A. Ellenbogen Lessons learned from data logging in a multicenter clinical trial using a late-generation implantable cardioverter-defibrillator. The Guardian ATP 4210 Multicenter Investigators Group J Am Coll Cardiol 24 1994 1692 1699
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1692-1699
    • Wood, M.A.1    Stambler, B.S.2    Damiano, R.J.3    Greenway, P.4    Ellenbogen, K.A.5
  • 4
    • 41149165849 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: Frequency, mechanisms, predictors, and survival impact
    • J.P. Daubert, W. Zareba, and D.S. Cannom et al. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact J Am Coll Cardiol 51 2008 1357 1365
    • (2008) J Am Coll Cardiol , vol.51 , pp. 1357-1365
    • Daubert, J.P.1    Zareba, W.2    Cannom, D.S.3
  • 5
    • 79251577161 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverter-defibrillator shocks: Incidence, predictors, and impact on mortality
    • J.B. van Rees, C.J. Borleffs, and M.K. de Bie et al. Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality J Am Coll Cardiol 57 2011 556 562
    • (2011) J Am Coll Cardiol , vol.57 , pp. 556-562
    • Van Rees, J.B.1    Borleffs, C.J.2    De Bie, M.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.