메뉴 건너뛰기




Volumn 19, Issue 3, 2014, Pages 259-263

Validity of measuring distal vastus medialis muscle using rehabilitative ultrasound imaging versus magnetic resonance imaging

Author keywords

Reliability; Ultrasound imaging; Validity; Vastus medialis

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; ECHOGRAPHY; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; MALE; MUSCLE CELL; MUSCLE THICKNESS; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; REHABILITATIVE ULTRASOUND IMAGING; RELIABILITY; ULTRASOUND SCANNER; ULTRASOUND TRANSDUCER; VALIDATION STUDY; VALIDITY; VASTUS MEDIALIS MUSCLE; ADOLESCENT; COMPARATIVE STUDY; DOPPLER FLOWMETRY; PATHOLOGY; PROCEDURES; QUADRICEPS FEMORIS MUSCLE; REPRODUCIBILITY; STATISTICAL MODEL; YOUNG ADULT;

EID: 84899954676     PISSN: 1356689X     EISSN: 15322769     Source Type: Journal    
DOI: 10.1016/j.math.2014.02.002     Document Type: Article
Times cited : (31)

References (21)
  • 1
    • 60849109506 scopus 로고    scopus 로고
    • Vastus medialis cross-sectional area is positively associated with patella cartilage and bone volumes in a pain-free community-based population
    • Berry P.A., Teichtahl A.J., Galevska-Dimitrovska A., Hanna F., Wluka A.E., Wang Y.C., et al. Vastus medialis cross-sectional area is positively associated with patella cartilage and bone volumes in a pain-free community-based population. Arthritis Res Ther 2008, 10:R143.
    • (2008) Arthritis Res Ther , vol.10
    • Berry, P.A.1    Teichtahl, A.J.2    Galevska-Dimitrovska, A.3    Hanna, F.4    Wluka, A.E.5    Wang, Y.C.6
  • 2
    • 84892488383 scopus 로고    scopus 로고
    • Using ultrasound to measure the fibre angle of vastus medialis oblique: a cardaveric validation study
    • Engelina S., Robertson C., Moggridge J., Killingback A., Adds P. Using ultrasound to measure the fibre angle of vastus medialis oblique: a cardaveric validation study. Knee 2014, 21:107-111.
    • (2014) Knee , vol.21 , pp. 107-111
    • Engelina, S.1    Robertson, C.2    Moggridge, J.3    Killingback, A.4    Adds, P.5
  • 3
    • 54249128912 scopus 로고    scopus 로고
    • Patellofemoral pain syndrome: a review on the associated neuromuscular deficits and current treatment options
    • Fagan V., Delahunt E. Patellofemoral pain syndrome: a review on the associated neuromuscular deficits and current treatment options. Br J Sports Med 2008, 42:489-495.
    • (2008) Br J Sports Med , vol.42 , pp. 489-495
    • Fagan, V.1    Delahunt, E.2
  • 4
    • 33645102462 scopus 로고    scopus 로고
    • An MRI investigation into the function of the transversus abdominis muscle during "drawing-in" of the abdominal wall
    • Hides J., Wilson S.J., Stanton W.R., McMahon S., Keto H., McMahon K., et al. An MRI investigation into the function of the transversus abdominis muscle during "drawing-in" of the abdominal wall. Spine 2006, 31:E175-E178.
    • (2006) Spine , vol.31
    • Hides, J.1    Wilson, S.J.2    Stanton, W.R.3    McMahon, S.4    Keto, H.5    McMahon, K.6
  • 5
    • 0026600802 scopus 로고
    • Diagnostic ultrasound imaging for measurement of the lumbar multifidus muscle in Normal Young adults
    • Hides J.A., Cooper D.H., Stokes M.J. Diagnostic ultrasound imaging for measurement of the lumbar multifidus muscle in Normal Young adults. Physiotherapy Theory Pract 1992, 8:19-26.
    • (1992) Physiotherapy Theory Pract , vol.8 , pp. 19-26
    • Hides, J.A.1    Cooper, D.H.2    Stokes, M.J.3
  • 6
    • 0028816596 scopus 로고
    • Magnetic resonance imaging and ultrasonography of the lumbar multifidus muscle: comparison of two different modalities
    • Hides J.A., Richardson C., Jull G. Magnetic resonance imaging and ultrasonography of the lumbar multifidus muscle: comparison of two different modalities. Spine 1995, 20:54-58.
    • (1995) Spine , vol.20 , pp. 54-58
    • Hides, J.A.1    Richardson, C.2    Jull, G.3
  • 7
    • 70649095951 scopus 로고    scopus 로고
    • Differences in sonographic characteristics of the vastus medialis obliquus between patients with patellofemoral pain syndrome and healthy adults
    • Jan M.-H., Lin D.-H., Lin J.-J., Lin C.-H.J., Cheng C.-K., Lin Y.-F. Differences in sonographic characteristics of the vastus medialis obliquus between patients with patellofemoral pain syndrome and healthy adults. Am J Sports Med 2009, 37:1743-1749.
    • (2009) Am J Sports Med , vol.37 , pp. 1743-1749
    • Jan, M.-H.1    Lin, D.-H.2    Lin, J.-J.3    Lin, C.-H.J.4    Cheng, C.-K.5    Lin, Y.-F.6
  • 10
    • 34347388662 scopus 로고    scopus 로고
    • Measurement of segmental cervical multifidus contraction by ultrasonography in asymptomatic adults
    • Lee J.-P., Tseng W.-Y.I., Shau Y.-W., Wang C.-L., Wang H.-K., Wang S.-F. Measurement of segmental cervical multifidus contraction by ultrasonography in asymptomatic adults. Man Ther 2007, 12:286-294.
    • (2007) Man Ther , vol.12 , pp. 286-294
    • Lee, J.-P.1    Tseng, W.-Y.I.2    Shau, Y.-W.3    Wang, C.-L.4    Wang, H.-K.5    Wang, S.-F.6
  • 11
    • 41649115259 scopus 로고    scopus 로고
    • Association between sonographic morphology of vastus medialis obliquus and patellar alignment in patients with patellofemoral pain syndrome
    • Lin Y.-F., Lin J.-J., Cheng C.-K., Lin D.-H., Jan M.-H. Association between sonographic morphology of vastus medialis obliquus and patellar alignment in patients with patellofemoral pain syndrome. J Orthop Sports Phys Ther 2008, 38:196-202.
    • (2008) J Orthop Sports Phys Ther , vol.38 , pp. 196-202
    • Lin, Y.-F.1    Lin, J.-J.2    Cheng, C.-K.3    Lin, D.-H.4    Jan, M.-H.5
  • 12
    • 77956745930 scopus 로고    scopus 로고
    • Validity of real-time ultrasound imaging to measure anterior hip muscle size: a comparison with magnetic resonance imaging
    • Mendis M.D., Wilson S.J., Stanton W.R., Hides J. Validity of real-time ultrasound imaging to measure anterior hip muscle size: a comparison with magnetic resonance imaging. J Orthop Sports Phys Ther 2010, 40:577-581.
    • (2010) J Orthop Sports Phys Ther , vol.40 , pp. 577-581
    • Mendis, M.D.1    Wilson, S.J.2    Stanton, W.R.3    Hides, J.4
  • 13
    • 67849094253 scopus 로고    scopus 로고
    • The validity of rehabilitative ultrasound imaging for measurement of trapezius muscle thickness
    • O'Sullivan C., Meaney J., Boyle G., Gormley J., Stokes M. The validity of rehabilitative ultrasound imaging for measurement of trapezius muscle thickness. Man Ther 2009, 14:572-578.
    • (2009) Man Ther , vol.14 , pp. 572-578
    • O'Sullivan, C.1    Meaney, J.2    Boyle, G.3    Gormley, J.4    Stokes, M.5
  • 15
    • 70349138607 scopus 로고    scopus 로고
    • Validity of real time ultrasound for measuring skeletal muscle size
    • Pretorius A., Keating J.L. Validity of real time ultrasound for measuring skeletal muscle size. Phys Ther Rev 2008, 13:415-426.
    • (2008) Phys Ther Rev , vol.13 , pp. 415-426
    • Pretorius, A.1    Keating, J.L.2
  • 16
    • 1442350465 scopus 로고    scopus 로고
    • Ultrasonographic assessment of human skeletal muscle size
    • Reeves N., Maganaris C., Narici M. Ultrasonographic assessment of human skeletal muscle size. Eur J Appl Physiology 2004, 91:116-118.
    • (2004) Eur J Appl Physiology , vol.91 , pp. 116-118
    • Reeves, N.1    Maganaris, C.2    Narici, M.3
  • 17
    • 64549162909 scopus 로고    scopus 로고
    • Do the vastus medialis obliquus and vastus medialis longus really exist? A systematic review
    • Smith T.O., Nichols R., Harle D., Donell S.T. Do the vastus medialis obliquus and vastus medialis longus really exist? A systematic review. Clin Anat 2009, 22:183-199.
    • (2009) Clin Anat , vol.22 , pp. 183-199
    • Smith, T.O.1    Nichols, R.2    Harle, D.3    Donell, S.T.4
  • 18
    • 84859153000 scopus 로고    scopus 로고
    • Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients
    • Thomaes T., Thomis M., Onkelinx S., Coudyzer W., Cornelissen V., Vanhees L. Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients. BMC Med Imaging 2012, 12.
    • (2012) BMC Med Imaging , vol.12
    • Thomaes, T.1    Thomis, M.2    Onkelinx, S.3    Coudyzer, W.4    Cornelissen, V.5    Vanhees, L.6
  • 19
    • 0031053656 scopus 로고    scopus 로고
    • Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging
    • Walton J.M., Roberts N., Whitehouse G.H. Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging. Br J Sports Med 1997, 31:59-64.
    • (1997) Br J Sports Med , vol.31 , pp. 59-64
    • Walton, J.M.1    Roberts, N.2    Whitehouse, G.H.3
  • 20
    • 80051679525 scopus 로고    scopus 로고
    • Ultrasound imaging and muscle function (Review)
    • Whittaker J.L., Stokes M. Ultrasound imaging and muscle function (Review). J Orthop Sports Phys Ther 2011, 41:572-580.
    • (2011) J Orthop Sports Phys Ther , vol.41 , pp. 572-580
    • Whittaker, J.L.1    Stokes, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.