메뉴 건너뛰기




Volumn 13, Issue 1, 2014, Pages 102-112

Non-contact heart rate and heart rate variability measurements: A review

Author keywords

Camera; Doppler; ECG; Heart rate; Heart rate variability; Non contact; Radar

Indexed keywords

CAMERAS; DOPPLER RADAR; ELECTROCARDIOGRAPHY; INFRARED IMAGING; PHYSIOLOGICAL MODELS; RADAR; RADAR MEASUREMENT;

EID: 84899800296     PISSN: 17468094     EISSN: 17468108     Source Type: Journal    
DOI: 10.1016/j.bspc.2014.03.004     Document Type: Review
Times cited : (248)

References (67)
  • 2
    • 0027402947 scopus 로고
    • Autonomic nervous system function
    • DOI 10.1097/00004691-199301000-00003
    • P.A. Low Autonomic nervous system function J. Clin. Neurophysiol. 10 1 1993 14 27 (Pubitemid 23057967)
    • (1993) Journal of Clinical Neurophysiology , vol.10 , Issue.1 , pp. 14-27
    • Low, P.A.1
  • 3
    • 6344251621 scopus 로고    scopus 로고
    • Heart rate variability: A noninvasive electrocardiographic method to measure the autonomic nervous system
    • J. Sztajzel Heart rate variability: a noninvasive electrocardiographic method to measure the autonomic nervous system Swiss Med. Weekly 143 2004 514 522 (Pubitemid 39389963)
    • (2004) Swiss Medical Weekly , vol.134 , Issue.35-36 , pp. 514-522
    • Sztajzel, J.1
  • 4
    • 0038458908 scopus 로고    scopus 로고
    • Heart rate monitoring
    • J. Achten, and A.E. Jeukendrup Heart rate monitoring Sports Med. 33 7 2003 517 538
    • (2003) Sports Med. , vol.33 , Issue.7 , pp. 517-538
    • Achten, J.1    Jeukendrup, A.E.2
  • 7
    • 80052049053 scopus 로고    scopus 로고
    • Compressed sensing for real-time energy-efficient ECG compression on wireless body sensor nodes
    • H. Mamaghanin, N. Khaled, D. Atenza, and P. Vandergheynst Compressed sensing for real-time energy-efficient ECG compression on wireless body sensor nodes IEEE Trans. Biomed. Eng. 58 9 2011 2456 2466
    • (2011) IEEE Trans. Biomed. Eng. , vol.58 , Issue.9 , pp. 2456-2466
    • Mamaghanin, H.1    Khaled, N.2    Atenza, D.3    Vandergheynst, P.4
  • 11
    • 78651079793 scopus 로고    scopus 로고
    • Cognitive and autonomic dysfunction measures in normal controls, white coat and borderline hypertension
    • A. Shehab, and A. Abdulle Cognitive and autonomic dysfunction measures in normal controls, white coat and borderline hypertension BMC Cardiovasc. Disord. 11 3 2011
    • (2011) BMC Cardiovasc. Disord. , vol.11 , Issue.3
    • Shehab, A.1    Abdulle, A.2
  • 12
    • 31944436424 scopus 로고    scopus 로고
    • Application of independent component analysis in removing artefacts from the electrocardiogram
    • DOI 10.1007/s00521-005-0013-y
    • T. He, G. Clifford, and L. Tarassenko Application of independent component analysis in removing artefacts from the electrocardiogram Neural Comput. Applic. 15 2006 105 116 (Pubitemid 43190386)
    • (2006) Neural Computing and Applications , vol.15 , Issue.2 , pp. 105-116
    • He, T.1    Clifford, G.2    Tarassenko, L.3
  • 13
    • 84859783208 scopus 로고    scopus 로고
    • Detection of the electrocardiogram fiducial points in the phase space using the Euclidian distance measure
    • E. Plesnik, O. Malgina, J.F. Tasič, and M. Zajc Detection of the electrocardiogram fiducial points in the phase space using the Euclidian distance measure Med. Eng. Phys. 34 4 2012 524 529
    • (2012) Med. Eng. Phys. , vol.34 , Issue.4 , pp. 524-529
    • Plesnik, E.1    Malgina, O.2    Tasič, J.F.3    Zajc, M.4
  • 17
    • 0031106763 scopus 로고    scopus 로고
    • A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV
    • DOI 10.1109/10.554762
    • A. Ruha, S. Sallinen, and S. Nissilä A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV IEEE Trans. Biomed. Eng. 44 3 1997 159 167 (Pubitemid 27084201)
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , Issue.3 , pp. 159-167
    • Ruha, A.1    Sallinen, S.2    Nissila, S.3
  • 19
    • 7544238485 scopus 로고    scopus 로고
    • Practice standards for electrocardiographic monitoring in hospital settings: An American Heart Association scientific statement from the councils on cardiovascular nursing, clinical cardiology, and cardiovascular disease in the young
    • DOI 10.1161/01.CIR.0000145144.56673.59
    • B.J. Drew, R.M. Califf, M. Funk, E.S. Kaufman, M.W. Krucoff, M.M. Laks, P.W. Macfarlane, C. Sommargren, S. Swiryn, and G.F. Van Hare Practice standards for electrocardiographic monitoring in hospital settings: an American heart association statement from the councils on cardiovascular nursing, clinical cardiology, and cardiovascular disease in the young: endorsed by the international society of computerized electrocardiology and the American Association of Critical-Care Nurses Circulation 110 2004 2721 2746 (Pubitemid 39453025)
    • (2004) Circulation , vol.110 , Issue.17 , pp. 2721-2746
    • Drew, B.J.1    Califf, R.M.2    Funk, M.3    Kaufman, E.S.4    Krucoff, M.W.5    Laks, M.M.6    Macfarlane, P.W.7    Sommargren, C.8    Swiryn, S.9    Van Hare, G.F.10
  • 20
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical physiological measurement
    • J. Allen Photoplethysmography and its application in clinical physiological measurement Physiol. Meas. 28 2007 R1 R39
    • (2007) Physiol. Meas. , vol.28
    • Allen, J.1
  • 21
    • 0019788635 scopus 로고
    • Photoelectric plethysmography - some fundamental aspects of the reflection and transmission method
    • DOI 10.1088/0143-0815/2/3/004
    • J.A. Nijboer, J.C. Dorlas, and H.F. Mahieu Photoelectric plethysmography - some fundamental aspects of the reflection and transmission method Clin. Phys. Physiol. Meas. 2 3 1981 205 215 (Pubitemid 12244682)
    • (1981) Clinical Physics and Physiological Measurement , vol.2 , Issue.3 , pp. 205-215
    • Nijboer, J.A.1    Dorlas, J.C.2    Mahieu, H.F.3
  • 22
    • 70349306240 scopus 로고    scopus 로고
    • Limitations of oximetry to measure heart rate variability measures
    • G. Lu, and F. Yang Limitations of oximetry to measure heart rate variability measures Cardiovasc. Eng. 9 2009 119 125
    • (2009) Cardiovasc. Eng. , vol.9 , pp. 119-125
    • Lu, G.1    Yang, F.2
  • 23
    • 34447529106 scopus 로고    scopus 로고
    • Contact-free measurement of cardiac pulse based on the analysis of thermal imagery
    • DOI 10.1109/TBME.2007.891930
    • M. Garbey, S. Nanfei, A. Merla, and I. Pavlidis Contact-free measurement of cardiac pulse based on the analysis of thermal imagery IEEE Trans. Biomed. Eng. 54 8 2007 1418 1426 (Pubitemid 47076250)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.8 , pp. 1418-1426
    • Garbey, M.1    Sun, N.2    Merla, A.3    Pavlidis, I.4
  • 24
    • 28844497673 scopus 로고    scopus 로고
    • Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method
    • DOI 10.1109/TBME.2005.857637
    • K. Watanabe, T. Watanabe, H. Watanabe, H. Ando, T. Ishikawa, and K. Kobayashi Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method IEEE Trans. Biomed. Eng. 52 12 2006 2100 2107 (Pubitemid 41774887)
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.12 , pp. 2100-2107
    • Watanabe, K.1    Watanabe, T.2    Watanabe, H.3    Ando, H.4    Ishikawa, T.5    Kobayashi, K.6
  • 25
    • 84881158367 scopus 로고    scopus 로고
    • A comparative evaluation of neural network classifiers for stress level analysis of automotive drivers using physiological signals
    • R.R. Singh, S. Conjeti, and R. Banerjee A comparative evaluation of neural network classifiers for stress level analysis of automotive drivers using physiological signals Biomed. Signal Process. Control 8 6 2013 740 754
    • (2013) Biomed. Signal Process. Control , vol.8 , Issue.6 , pp. 740-754
    • Singh, R.R.1    Conjeti, S.2    Banerjee, R.3
  • 27
    • 0031778492 scopus 로고    scopus 로고
    • A prospective study of heart rate response following trauma and the subsequent development of Posttraumatic stress disorder
    • A.Y. Shalev, T. Sahar, S. Freedman, T. Peri, N. Glick, D. Brandes, S.P. Orr, and R.K. Pitman A prospective study of heart rate response following trauma and the subsequent development of Posttraumatic stress disorder Arch. Gen. Psychiatry 55 1998 553 560
    • (1998) Arch. Gen. Psychiatry , vol.55 , pp. 553-560
    • Shalev, A.Y.1    Sahar, T.2    Freedman, S.3    Peri, T.4    Glick, N.5    Brandes, D.6    Orr, S.P.7    Pitman, R.K.8
  • 29
    • 84872144142 scopus 로고    scopus 로고
    • Mind over matter: Reappraising arousal improves cardiovascular and cognitive responses to stress
    • J.P. Jamieson, M.K. Nock, and W.B. Mendes Mind over matter: reappraising arousal improves cardiovascular and cognitive responses to stress J. Exp. Psychol. Gen. 141 3 2012 417 422
    • (2012) J. Exp. Psychol. Gen. , vol.141 , Issue.3 , pp. 417-422
    • Jamieson, J.P.1    Nock, M.K.2    Mendes, W.B.3
  • 30
    • 77956649772 scopus 로고    scopus 로고
    • Analysis of heart rate variability during exercise stress testing using respiratory information
    • R. Bailon, L. Maindardi, M. Orini, L. Sörnmo, and P. Laguna Analysis of heart rate variability during exercise stress testing using respiratory information Biomed. Signal Process. Control 5 4 2010 299 310
    • (2010) Biomed. Signal Process. Control , vol.5 , Issue.4 , pp. 299-310
    • Bailon, R.1    Maindardi, L.2    Orini, M.3    Sörnmo, L.4    Laguna, P.5
  • 34
    • 84899874254 scopus 로고    scopus 로고
    • Multiresolution approach for noncontact measurements of arterial pulse using thermal imaging, augmented vision perception in infrared
    • Springer-Verlag London
    • S.Y. Chekmenev, A.A. Farag, W.M. Miller, E.A. Essock, and A. Bhatnagar Multiresolution approach for noncontact measurements of arterial pulse using thermal imaging, augmented vision perception in infrared Advances in Pattern Recognition 2009 Springer-Verlag London 87 112
    • (2009) Advances in Pattern Recognition , pp. 87-112
    • Chekmenev, S.Y.1    Farag, A.A.2    Miller, W.M.3    Essock, E.A.4    Bhatnagar, A.5
  • 35
    • 79955920713 scopus 로고    scopus 로고
    • Non-contact, wavelet-based measurement of Vital signs using thermal imaging
    • (special issue Applicable Image Processing Techniques)
    • S.Y. Chekmenev, H. Rara, and A.A. Farag Non-contact, wavelet-based measurement of Vital signs using thermal imaging ICGST Int. J. Graph. Vis. Image Process. (GVIP) 6 2006 (special issue Applicable Image Processing Techniques)
    • (2006) ICGST Int. J. Graph. Vis. Image Process. (GVIP) , vol.6
    • Chekmenev, S.Y.1    Rara, H.2    Farag, A.A.3
  • 37
    • 34447529106 scopus 로고    scopus 로고
    • Contact-free measurement of cardiac pulse based on the analysis of thermal imagery
    • DOI 10.1109/TBME.2007.891930
    • M. Garbey, N. Sun, A. Merla, and I. Pavlidis Contact-free measurement of cardiac pulse based on the analysis of thermal imagery IEEE Trans. Biomed. Eng. 54 8 2007 1418 1426 (Pubitemid 47076250)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.8 , pp. 1418-1426
    • Garbey, M.1    Sun, N.2    Merla, A.3    Pavlidis, I.4
  • 39
    • 77952701951 scopus 로고    scopus 로고
    • Non-contact, automated cardiac pulse measurement using video imaging and blind source separation
    • M.Z. Poh, D.J. McDuff, and R.W. Picard Non-contact, automated cardiac pulse measurement using video imaging and blind source separation Opt. Express 18 10 2010 10762 10774
    • (2010) Opt. Express , vol.18 , Issue.10 , pp. 10762-10774
    • Poh, M.Z.1    McDuff, D.J.2    Picard, R.W.3
  • 40
    • 79551572458 scopus 로고    scopus 로고
    • Advancements in noncontact, multiparameter physiological measurements using a webcam
    • M.Z. Poh, D.J. McDuff, and R.W. Picard Advancements in noncontact, multiparameter physiological measurements using a webcam IEEE Trans. Biomed. Eng. 58 1 2011 7 11
    • (2011) IEEE Trans. Biomed. Eng. , vol.58 , Issue.1 , pp. 7-11
    • Poh, M.Z.1    McDuff, D.J.2    Picard, R.W.3
  • 41
    • 34250201117 scopus 로고    scopus 로고
    • Heart rate measurement based on a time-lapse image
    • DOI 10.1016/j.medengphy.2006.09.006, PII S1350453306001901
    • C. Takano, and Y. Ohta Heart rate measurement based on a time-lapse image Med. Eng. Phys. 29 8 2007 853 857 (Pubitemid 46898901)
    • (2007) Medical Engineering and Physics , vol.29 , Issue.8 , pp. 853-857
    • Takano, C.1    Ohta, Y.2
  • 42
    • 84879633866 scopus 로고    scopus 로고
    • Continuous wavelet filtering on webcam photoplethysmographic signals to remotely assess the instantaneous heart rate
    • F. Bousefsaf, C. Maaoui, and A. Pruski Continuous wavelet filtering on webcam photoplethysmographic signals to remotely assess the instantaneous heart rate Biomed. Signal Process. Control 8 2013 568 574
    • (2013) Biomed. Signal Process. Control , vol.8 , pp. 568-574
    • Bousefsaf, F.1    Maaoui, C.2    Pruski, A.3
  • 43
    • 58149112508 scopus 로고    scopus 로고
    • Remote plethysmographic imaging using ambient light
    • W. Verkruysse, L.O. Svaasand, and J.S. Nelson Remote plethysmographic imaging using ambient light Opt. Express 16 26 2008 21434 21445
    • (2008) Opt. Express , vol.16 , Issue.26 , pp. 21434-21445
    • Verkruysse, W.1    Svaasand, L.O.2    Nelson, J.S.3
  • 44
    • 73049087136 scopus 로고    scopus 로고
    • Multitunable microwave system for touchless heartbeat detection and heart rate variability extraction
    • D. Obeid, S. Sadek, G. Zaharia, and G.E. Zein Multitunable microwave system for touchless heartbeat detection and heart rate variability extraction Microwave Opt. Technol. Lett. 52 1 2010 192 198
    • (2010) Microwave Opt. Technol. Lett. , vol.52 , Issue.1 , pp. 192-198
    • Obeid, D.1    Sadek, S.2    Zaharia, G.3    Zein, G.E.4
  • 46
    • 33845489135 scopus 로고    scopus 로고
    • Optical vibrocardiography: A novel tool for the optical monitoring of cardiac activity
    • DOI 10.1007/s10439-006-9202-9
    • U. Morbiducci, L. Scalise, M.D. Melis, and M. Grigioni Optical vibrocardiography: a novel tool for the optical monitoring of cardiac activity Ann. Biomed. Eng. 35 1 2007 45 58 (Pubitemid 44916315)
    • (2007) Annals of Biomedical Engineering , vol.35 , Issue.1 , pp. 45-58
    • Morbiducci, U.1    Scalise, L.2    De Melis, M.3    Grigioni, M.4
  • 47
    • 42949110253 scopus 로고    scopus 로고
    • Non-contact cardiac monitoring from carotid artery using optical vibrocardiography
    • DOI 10.1016/j.medengphy.2007.05.008, PII S1350453307001002
    • L. Scalise, and U. Morbiducci Non-contact cardiac monitoring from carotid artery using optical vibrocardiography Med. Eng. Phys. 30 4 2008 490 497 (Pubitemid 351615211)
    • (2008) Medical Engineering and Physics , vol.30 , Issue.4 , pp. 490-497
    • Scalise, L.1    Morbiducci, U.2
  • 50
    • 33747015295 scopus 로고    scopus 로고
    • A new IEEE standard for safety levels with respect to human exposure to radio-frequency radiation
    • DOI 10.1109/MAP.2006.1645601
    • J.C. Lin A new IEEE standard for safety levels with respect to human exposure to radiofrequency radiation IEEE Ant. Propag. Mag. 48 2006 157 159 (Pubitemid 44202782)
    • (2006) IEEE Antennas and Propagation Magazine , vol.48 , Issue.1 , pp. 157-159
    • Lin, J.C.1
  • 51
    • 84899874554 scopus 로고    scopus 로고
    • Sub-μW signal power Doppler radar heart rate detection
    • Asia-Pacific
    • S. Yamada, C. Mingqi, and V. Lubecke Sub-μW signal power Doppler radar heart rate detection Microwave Conference, 2006. APMC 2006 Asia-Pacific, vol. 51 (54) 2006 12 15
    • (2006) Microwave Conference, 2006. APMC 2006 , vol.51 , Issue.54 , pp. 12-15
    • Yamada, S.1    Mingqi, C.2    Lubecke, V.3
  • 52
    • 77950287625 scopus 로고    scopus 로고
    • Contact-free measurement of heart rate variability via a microwave sensor
    • G. Lu, F. Yang, Y. Tian, X. Jing, and J. Wang Contact-free measurement of heart rate variability via a microwave sensor Sensors 9 2009 9572 9581
    • (2009) Sensors , vol.9 , pp. 9572-9581
    • Lu, G.1    Yang, F.2    Tian, Y.3    Jing, X.4    Wang, J.5
  • 53
    • 45849116270 scopus 로고    scopus 로고
    • A novel automatic activation measurement method for stress monitoring: Non-contact measurement of heart rate variability using a compact microwave radar
    • S. Suzuki, T. Matsui, H. Imuta, M. Uenoyama, H. Yura, M. Ishihara, and M. Kawakami A novel automatic activation measurement method for stress monitoring: non-contact measurement of heart rate variability using a compact microwave radar Med. Biol. Eng. Comput. 46 2008 709 714
    • (2008) Med. Biol. Eng. Comput. , vol.46 , pp. 709-714
    • Suzuki, S.1    Matsui, T.2    Imuta, H.3    Uenoyama, M.4    Yura, H.5    Ishihara, M.6    Kawakami, M.7
  • 55
    • 83055163708 scopus 로고    scopus 로고
    • Non-contact biopotentials sensor for remote human detection, sensors & their applications XVI
    • A.E. Mahdi, and L. Faggion Non-contact biopotentials sensor for remote human detection, sensors & their applications XVI J. Phys.: Conf. Ser. 307 2011 012056
    • (2011) J. Phys.: Conf. Ser. , vol.307 , pp. 012056
    • Mahdi, A.E.1    Faggion, L.2
  • 56
    • 0008528991 scopus 로고
    • Ultrahigh impedance capacitively coupled heart imaging array
    • A. Clippingdale, R.J. Clark, and C. Watkins Ultrahigh impedance capacitively coupled heart imaging array Rev. Sci. Instrum. 65 1 1994 269 270
    • (1994) Rev. Sci. Instrum. , vol.65 , Issue.1 , pp. 269-270
    • Clippingdale, A.1    Clark, R.J.2    Watkins, C.3
  • 57
    • 0036472829 scopus 로고    scopus 로고
    • Electric potential probes-New directions in the remote sensing of the human body
    • DOI 10.1088/0957-0233/13/2/304, PII S0957023302245750
    • C. Harland, T.D. Clark, and R.J. Prance Electric potential probes - new directions in the remote sensing of the human body Meas. Sci. Technol. 13 2002 163 169 (Pubitemid 34175927)
    • (2002) Measurement Science and Technology , vol.13 , Issue.2 , pp. 163-169
    • Harland, C.J.1    Clark, T.D.2    Prance, R.J.3
  • 60
    • 78650317618 scopus 로고    scopus 로고
    • Dry-contact and noncontact biopotential electrodes: Methodological review
    • Y.M. Chi, T.P. Jung, and G. Cauwenberghs Dry-contact and noncontact biopotential electrodes: methodological review IEEE Rev. Biomed. Eng. 3 2010 106 119
    • (2010) IEEE Rev. Biomed. Eng. , vol.3 , pp. 106-119
    • Chi, Y.M.1    Jung, T.P.2    Cauwenberghs, G.3
  • 61
    • 77952110227 scopus 로고    scopus 로고
    • Optimising calibration and measurement capabilities in terms of economics in conformity assessment
    • ISSN 0949-1775
    • G. Begeš, J. Drnovšek, and L.R. Pendrill Optimising calibration and measurement capabilities in terms of economics in conformity assessment Accredit. Qual. Assur. 15 3 2010 147 154 ISSN 0949-1775
    • (2010) Accredit. Qual. Assur. , vol.15 , Issue.3 , pp. 147-154
    • Begeš, G.1    Drnovšek, J.2    Pendrill, L.R.3
  • 62
    • 0036538432 scopus 로고    scopus 로고
    • Measurement uncertainty, traceability and evaluation of test results in testing laboratories
    • DOI 10.1088/0957-0233/13/4/320, PII S0957023302289407
    • G. Begeš, J. Drnovšek, I. Pušnik, and J. Bojkovski Measurement uncertainty, traceability and evaluation of test results in testing laboratories Meas. Sci. Technol. 13 2002 565 572 ISSN 0957-0233 (Pubitemid 34452205)
    • (2002) Measurement Science and Technology , vol.13 , Issue.4 , pp. 565-572
    • Beges, G.1    Drnovsek, J.2    Pusnik, I.3    Bojkovski, J.4
  • 63
    • 84899840093 scopus 로고    scopus 로고
    • Thermal imaging of hands during simple gymnastics elements on the wooden bar with and without use of magnesium carbonate
    • ISSN 1855-7171. [Spletna izd.]
    • I. Pušnik, and I. Čuk Thermal imaging of hands during simple gymnastics elements on the wooden bar with and without use of magnesium carbonate Sci. Gymnastics J. 6 1 2014 67 72 ISSN 1855-7171. [Spletna izd.]
    • (2014) Sci. Gymnastics J. , vol.6 , Issue.1 , pp. 67-72
    • Pušnik, I.1    Čuk, I.2
  • 64
    • 84872739895 scopus 로고    scopus 로고
    • A large aperture blackbody bath for calibration of thermal imagers
    • ISSN 0957-0233
    • A. Miklavec, I. Pušnik, V. Batagelj, and J. Drnovšek A large aperture blackbody bath for calibration of thermal imagers Meas. Sci. Technol. 2 24 2013 1 8 ISSN 0957-0233
    • (2013) Meas. Sci. Technol. , vol.2 , Issue.24 , pp. 1-8
    • Miklavec, A.1    Pušnik, I.2    Batagelj, V.3    Drnovšek, J.4
  • 65
    • 79953180849 scopus 로고    scopus 로고
    • Comparison of blackbodies for calibration of infrared ear thermometers
    • ISSN 0195-928X
    • I. Pušnik et al. Comparison of blackbodies for calibration of infrared ear thermometers Int. J. Thermophys. 32 1/2 2011 127 138 ISSN 0195-928X
    • (2011) Int. J. Thermophys. , vol.32 , Issue.1-2 , pp. 127-138
    • Pušnik, I.1
  • 66
    • 79953180850 scopus 로고    scopus 로고
    • Analysis of thermal imagers
    • ISSN 0195-928X
    • G. Grgić, and I. Pušnik Analysis of thermal imagers Int. J. Thermophys. 32 1/2 2011 237 247 ISSN 0195-928X
    • (2011) Int. J. Thermophys. , vol.32 , Issue.1-2 , pp. 237-247
    • Grgić, G.1    Pušnik, I.2
  • 67
    • 68949142884 scopus 로고    scopus 로고
    • Dilemmas in measurement of human body temperature
    • ISSN 1073-9149
    • I. Pušnik, and A. Miklavec Dilemmas in measurement of human body temperature Instrum. Sci. Tech. 37 5 2009 516 530 ISSN 1073-9149
    • (2009) Instrum. Sci. Tech. , vol.37 , Issue.5 , pp. 516-530
    • Pušnik, I.1    Miklavec, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.