메뉴 건너뛰기




Volumn 29, Issue 3, 2014, Pages 293-302

Applications of computational modeling in cardiac surgery

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTATIONAL CARDIAC MODELING; COMPUTER; COMPUTER PROGRAM; COMPUTER SIMULATION; FINITE ELEMENT ANALYSIS; HEART ASSIST DEVICE; HEART MUSCLE CELL; HEART SURGERY; HEART VENTRICLE WALL; HUMAN; MATHEMATICAL MODEL; MITRAL ANNULOPLASTY; REVIEW; STRESS FIBER;

EID: 84899649233     PISSN: 08860440     EISSN: 15408191     Source Type: Journal    
DOI: 10.1111/jocs.12332     Document Type: Review
Times cited : (43)

References (48)
  • 1
    • 0010492727 scopus 로고
    • Stress, strain, growth, and remodeling of living organisms
    • Fung YC:, Stress, strain, growth, and remodeling of living organisms. Z Angew Math Phys 1995; S469-S482.
    • (1995) Z Angew Math Phys
    • Fung, Y.1
  • 2
    • 1542344953 scopus 로고    scopus 로고
    • Review paper: Continuum biomechanics of soft biological tissues
    • Humphrey JD:, Review paper: Continuum biomechanics of soft biological tissues. Proc R Soc A Math Phys Eng Sci 2003; 459: 3-46.
    • (2003) Proc R Soc A Math Phys Eng Sci , vol.459 , pp. 3-46
    • Humphrey, J.1
  • 3
    • 0015297048 scopus 로고
    • Finite-element model for the mechanical behavior of the left ventricle: Prediction of deformation in the potassium-arrested rat heart
    • Janz RF, Grimm AF:, Finite-element model for the mechanical behavior of the left ventricle: Prediction of deformation in the potassium-arrested rat heart. Circ Res 1972; 30: 244-252.
    • (1972) Circ Res , vol.30 , pp. 244-252
    • Janz, R.F.1    Grimm, A.2
  • 4
    • 84255171044 scopus 로고    scopus 로고
    • Electromechanical feedback with reduced cellular connectivity alters electrical activity in an infarct injured left ventricle: A finite element model study
    • Wall ST, Guccione JM, Ratcliffe MB, et al. Electromechanical feedback with reduced cellular connectivity alters electrical activity in an infarct injured left ventricle: A finite element model study. Am J Physiol Heart Circ Physiol 2012; 302: H206-H214.
    • (2012) Am J Physiol Heart Circ Physiol , vol.302
    • Wall, S.T.1    Guccione, J.M.2    Ratcliffe, M.B.3
  • 6
    • 0027551722 scopus 로고
    • Mechanics of active contraction in cardiac muscle: Part II-cylindrical models of the systolic left ventricle
    • Guccione JM, Waldman LK, McCulloch AD:, Mechanics of active contraction in cardiac muscle: Part II-cylindrical models of the systolic left ventricle. J Biomech Eng 1993; 115: 82-90.
    • (1993) J Biomech Eng , vol.115 , pp. 82-90
    • Guccione, J.M.1    Waldman, L.K.2    McCulloch, A.3
  • 7
    • 0029114064 scopus 로고
    • Finite element stress analysis of left ventricular mechanics in the beating dog heart
    • Guccione JM, Costa KD, McCulloch AD:, Finite element stress analysis of left ventricular mechanics in the beating dog heart. J Biomech 1995; 28: 1167-1177.
    • (1995) J Biomech , vol.28 , pp. 1167-1177
    • Guccione, J.M.1    Costa, K.D.2    McCulloch, A.3
  • 8
    • 0019626710 scopus 로고
    • Ventricular wall stress
    • Yin FC:, Ventricular wall stress. Circ Res 1981; 49: 829-842.
    • (1981) Circ Res , vol.49 , pp. 829-842
    • Yin, F.1
  • 9
    • 0014478255 scopus 로고
    • Fiber orientation in the canine left ventricle during diastole and systole
    • Streeter DD, Spotnitz HM, Patel DP, et al. Fiber orientation in the canine left ventricle during diastole and systole. Circ Res 1969; 24: 339-347.
    • (1969) Circ Res , vol.24 , pp. 339-347
    • Streeter, D.D.1    Spotnitz, H.M.2    Patel, D.P.3
  • 10
    • 78650426954 scopus 로고    scopus 로고
    • Comparison of the Young-Laplace law and finite element based calculation of ventricular wall stress: Implications for postinfarct and surgical ventricular remodeling
    • Zhang Z, Tendulkar A, Sun K, et al. Comparison of the Young-Laplace law and finite element based calculation of ventricular wall stress: Implications for postinfarct and surgical ventricular remodeling. Ann Thorac Surg 2011; 91: 150-156.
    • (2011) Ann Thorac Surg , vol.91 , pp. 150-156
    • Zhang, Z.1    Tendulkar, A.2    Sun, K.3
  • 11
    • 0018965458 scopus 로고
    • Cardiac hypertrophy: Useful adaptation or pathologic process
    • Grossman W:, Cardiac hypertrophy: Useful adaptation or pathologic process? Am J Med 1980; 69: 576-584.
    • (1980) Am J Med , vol.69 , pp. 576-584
    • Grossman, W.1
  • 12
    • 84899622898 scopus 로고    scopus 로고
    • Patient-specific finite element modeling of the Cardiokinetix Parachute® device: Effects on left ventricular wall stress and function
    • doi: 10.1007/s11517-014-1159-5. [Epub ahead of print]
    • Lee LC, Ge L, Zhihong Z, et al. Patient-specific finite element modeling of the Cardiokinetix Parachute® device: Effects on left ventricular wall stress and function. Med Biol Eng Comput 2013; doi: 10.1007/s11517-014-1159-5. [Epub ahead of print]
    • (2013) Med Biol Eng Comput
    • Lee, L.C.1    Ge, L.2    Zhihong, Z.3
  • 13
    • 70350572791 scopus 로고    scopus 로고
    • Percutaneous implantation of an intraventricular device for the treatment of heart failure: Experimental results and proof of concept
    • Nikolic SD, Khairkhahan A, Ryu M, et al. Percutaneous implantation of an intraventricular device for the treatment of heart failure: Experimental results and proof of concept. J Card Fail 2009; 15: 790-797.
    • (2009) J Card Fail , vol.15 , pp. 790-797
    • Nikolic, S.D.1    Khairkhahan, A.2    Ryu, M.3
  • 14
    • 77952982640 scopus 로고    scopus 로고
    • Percutaneous implantation of the left ventricular partitioning device for chronic heart failure: A pilot study with 1-year follow-up
    • Sagic D, Otasevic P, Sievert H, et al. Percutaneous implantation of the left ventricular partitioning device for chronic heart failure: A pilot study with 1-year follow-up. Eur J Heart Fail 2010; 12: 600-606.
    • (2010) Eur J Heart Fail , vol.12 , pp. 600-606
    • Sagic, D.1    Otasevic, P.2    Sievert, H.3
  • 15
    • 84878246685 scopus 로고    scopus 로고
    • Biventricular finite element modeling of the Acorn CorCap Cardiac Support Device on a failing heart
    • Wenk JF, Ge L, Zhang Z, et al. Biventricular finite element modeling of the Acorn CorCap Cardiac Support Device on a failing heart. Ann Thorac Surg 2013; 95: 2022-2027.
    • (2013) Ann Thorac Surg , vol.95 , pp. 2022-2027
    • Wenk, J.F.1    Ge, L.2    Zhang, Z.3
  • 16
    • 31144450503 scopus 로고    scopus 로고
    • Experimental and clinical studies with the Paracor cardiac restraint device
    • Magovern JA:, Experimental and clinical studies with the Paracor cardiac restraint device. Semin Thorac Cardiovasc Surg 2005; 17: 364-368.
    • (2005) Semin Thorac Cardiovasc Surg , vol.17 , pp. 364-368
    • Magovern, J.1
  • 17
    • 33947729902 scopus 로고    scopus 로고
    • Adjustable, physiological ventricular restraint improves left ventricular mechanics and reduces dilatation in an ovine model of chronic heart failure
    • Ghanta RK, Rangaraj A, Umakanthan R, et al. Adjustable, physiological ventricular restraint improves left ventricular mechanics and reduces dilatation in an ovine model of chronic heart failure. Circulation 2007; 115: 1201-1210.
    • (2007) Circulation , vol.115 , pp. 1201-1210
    • Ghanta, R.K.1    Rangaraj, A.2    Umakanthan, R.3
  • 18
    • 76449120049 scopus 로고    scopus 로고
    • Effect of adjustable passive constraint on the failing left ventricle: A finite element model study
    • Jhun CS, Wenk JF, Zhang Z, et al. Effect of adjustable passive constraint on the failing left ventricle: A finite element model study. Ann Thorac Surg 2010; 89: 132-137.
    • (2010) Ann Thorac Surg , vol.89 , pp. 132-137
    • Jhun, C.S.1    Wenk, J.F.2    Zhang, Z.3
  • 19
    • 0142213864 scopus 로고    scopus 로고
    • Global surgical experience with the Acorn cardiac support device
    • Oz MC, Konertz WF, Kleber FX, et al. Global surgical experience with the Acorn cardiac support device. J Thorac Cardiovasc Surg 2003; 126: 983-991.
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 983-991
    • Oz, M.C.1    Konertz, W.F.2    Kleber, F.X.3
  • 20
    • 0028266459 scopus 로고
    • Changes in passive mechanical stiffness of myocardial tissue with aneurysm formation
    • Gupta KB, Ratcliffe MB, Fallert MA, et al. Changes in passive mechanical stiffness of myocardial tissue with aneurysm formation. Circulation 1994; 89: 2315-2326.
    • (1994) Circulation , vol.89 , pp. 2315-2326
    • Gupta, K.B.1    Ratcliffe, M.B.2    Fallert, M.A.3
  • 21
    • 0029347445 scopus 로고
    • An inverse approach to determining myocardial material properties
    • Moulton MJ, Creswell LL, Actis RL, et al. An inverse approach to determining myocardial material properties. J Biomech 1995; 28: 935-948.
    • (1995) J Biomech , vol.28 , pp. 935-948
    • Moulton, M.J.1    Creswell, L.L.2    Actis, R.L.3
  • 22
    • 0029846305 scopus 로고    scopus 로고
    • Myocardial material property determination in the in vivo heart using magnetic resonance imaging
    • Moulton MJ, Creswell LL, Downing SW, et al. Myocardial material property determination in the in vivo heart using magnetic resonance imaging. Int J Card Imaging 1996; 12: 153-167.
    • (1996) Int J Card Imaging , vol.12 , pp. 153-167
    • Moulton, M.J.1    Creswell, L.L.2    Downing, S.W.3
  • 23
    • 0028846783 scopus 로고
    • Mechanical dysfunction in the border zone of an ovine model of left ventricular aneurysm
    • Moulton MJ, Downing SW, Creswell LL, et al. Mechanical dysfunction in the border zone of an ovine model of left ventricular aneurysm. Ann Thorac Surg 1995; 60: 986-997.
    • (1995) Ann Thorac Surg , vol.60 , pp. 986-997
    • Moulton, M.J.1    Downing, S.W.2    Creswell, L.L.3
  • 24
    • 0035116397 scopus 로고    scopus 로고
    • Mechanism underlying mechanical dysfunction in the border zone of left ventricular aneurysm: A finite element model study
    • Guccione JM, Moonly SM, Moustakidis P, et al. Mechanism underlying mechanical dysfunction in the border zone of left ventricular aneurysm: A finite element model study. Ann Thorac Surg 2001; 71: 654-662.
    • (2001) Ann Thorac Surg , vol.71 , pp. 654-662
    • Guccione, J.M.1    Moonly, S.M.2    Moustakidis, P.3
  • 25
    • 80052786431 scopus 로고    scopus 로고
    • A novel method for quantifying the in-vivo mechanical effect of material injected into a myocardial infarction
    • Wenk JF, Eslami P, Zhang Z, et al. A novel method for quantifying the in-vivo mechanical effect of material injected into a myocardial infarction. Ann Thorac Surg 2011; 92: 935-941.
    • (2011) Ann Thorac Surg , vol.92 , pp. 935-941
    • Wenk, J.F.1    Eslami, P.2    Zhang, Z.3
  • 26
    • 77953478009 scopus 로고    scopus 로고
    • Dor procedure for dyskinetic anteroapical myocardial infarction fails to improve contractility in the border zone
    • 239.e1-e4.
    • Sun K, Zhang Z, Suzuki T, et al. Dor procedure for dyskinetic anteroapical myocardial infarction fails to improve contractility in the border zone. J Thorac Cardiovasc Surg 2010; 140: 233-239 239.e1-e4.
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 233-239
    • Sun, K.1    Zhang, Z.2    Suzuki, T.3
  • 27
    • 0036830172 scopus 로고    scopus 로고
    • The Dor procedure: What has changed after fifteen years of clinical practice
    • Menicanti L, Di Donato M:, The Dor procedure: What has changed after fifteen years of clinical practice? J Thorac Cardiovasc Surg 2002; 124: 886-890.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 886-890
    • Menicanti, L.1    Di Donato, M.2
  • 28
    • 0037130780 scopus 로고    scopus 로고
    • Non-ischemic infarct extension: A new type of infarct enlargement and a potential therapeutic target
    • Ratcliffe MB:, Non-ischemic infarct extension: A new type of infarct enlargement and a potential therapeutic target. J Am Coll Cardiol 2002; 40: 1168-1171.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 1168-1171
    • Ratcliffe, M.1
  • 29
    • 77953221683 scopus 로고    scopus 로고
    • A computationally efficient formal optimization of regional myocardial contractility in a sheep with left ventricular aneurysm
    • Sun K, Stander N, Jhun CS, et al. A computationally efficient formal optimization of regional myocardial contractility in a sheep with left ventricular aneurysm. J Biomech Eng 2009; 131: 111001.
    • (2009) J Biomech Eng , vol.131 , pp. 111001
    • Sun, K.1    Stander, N.2    Jhun, C.S.3
  • 30
    • 64549144270 scopus 로고    scopus 로고
    • Coronary bypass surgery with or without surgical ventricular reconstruction
    • Jones RH, Velazquez EJ, Michler RE, et al. Coronary bypass surgery with or without surgical ventricular reconstruction. N Engl J Med 2009; 360: 1705-1717.
    • (2009) N Engl J Med , vol.360 , pp. 1705-1717
    • Jones, R.H.1    Velazquez, E.J.2    Michler, R.E.3
  • 31
    • 84870239096 scopus 로고    scopus 로고
    • Surgical ventricular restoration for the treatment of heart failure
    • Buckberg G, Athanasuleas C, Conte J:, Surgical ventricular restoration for the treatment of heart failure. Nat Rev Cardiol 2012; 9: 703-716.
    • (2012) Nat Rev Cardiol , vol.9 , pp. 703-716
    • Buckberg, G.1    Athanasuleas, C.2    Conte, J.3
  • 32
    • 33645996052 scopus 로고    scopus 로고
    • Septal anterior ventricular exclusion operation (Pacopexy) for ischemic dilated cardiomyopathy: Treat form not disease
    • Isomura T, Horii T, Suma H, et al. Septal anterior ventricular exclusion operation (Pacopexy) for ischemic dilated cardiomyopathy: Treat form not disease. Eur J Cardiothorac Surg 2006; 29 (Suppl 1): S245-S250.
    • (2006) Eur J Cardiothorac Surg , vol.29 , Issue.SUPPL. 1
    • Isomura, T.1    Horii, T.2    Suma, H.3
  • 33
    • 77953069413 scopus 로고    scopus 로고
    • First finite element model of the left ventricle with mitral valve: Insights into ischemic mitral regurgitation
    • Wenk JF, Zhang Z, Cheng G, et al. First finite element model of the left ventricle with mitral valve: Insights into ischemic mitral regurgitation. Ann Thorac Surg 2010; 89: 1546-1553.
    • (2010) Ann Thorac Surg , vol.89 , pp. 1546-1553
    • Wenk, J.F.1    Zhang, Z.2    Cheng, G.3
  • 34
    • 84863241485 scopus 로고    scopus 로고
    • The effect of mitral annuloplasty shape in ischemic mitral regurgitation: A finite element simulation
    • Wong VM, Wenk JF, Zhang Z, et al. The effect of mitral annuloplasty shape in ischemic mitral regurgitation: A finite element simulation. Ann Thorac Surg 2012; 93: 776-782.
    • (2012) Ann Thorac Surg , vol.93 , pp. 776-782
    • Wong, V.M.1    Wenk, J.F.2    Zhang, Z.3
  • 35
    • 0031193669 scopus 로고    scopus 로고
    • Annular dilatation increases stress in the mitral valve and delays coaptation: A finite element computer model
    • Kunzelman KS, Reimink MS, Cochran RP:, Annular dilatation increases stress in the mitral valve and delays coaptation: A finite element computer model. Cardiovasc Surg 1997; 5: 427-434.
    • (1997) Cardiovasc Surg , vol.5 , pp. 427-434
    • Kunzelman, K.S.1    Reimink, M.S.2    Cochran, R.3
  • 36
    • 0031933187 scopus 로고    scopus 로고
    • Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: A finite element model
    • Kunzelman KS, Reimink MS, Cochran RP:, Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: A finite element model. J Heart Valve Dis 1998; 7: 108-116.
    • (1998) J Heart Valve Dis , vol.7 , pp. 108-116
    • Kunzelman, K.S.1    Reimink, M.S.2    Cochran, R.3
  • 37
    • 34250347811 scopus 로고    scopus 로고
    • The Geoform disease-specific annuloplasty system: A finite element study
    • Votta E, Maisano F, Bolling SF, et al. The Geoform disease-specific annuloplasty system: A finite element study. Ann Thorac Surg 2007; 84: 92-101.
    • (2007) Ann Thorac Surg , vol.84 , pp. 92-101
    • Votta, E.1    Maisano, F.2    Bolling, S.F.3
  • 38
    • 84857847977 scopus 로고    scopus 로고
    • Mitral valve annuloplasty: A quantitative clinical and mechanical comparison of different annuloplasty devices
    • Rausch MK, Bothe W, Kvitting JPE, et al. Mitral valve annuloplasty: A quantitative clinical and mechanical comparison of different annuloplasty devices. Ann Biomed Eng 2012; 40: 750-761.
    • (2012) Ann Biomed Eng , vol.40 , pp. 750-761
    • Rausch, M.K.1    Bothe, W.2    Kvitting, J.P.E.3
  • 39
    • 78751512647 scopus 로고    scopus 로고
    • Effects of different annuloplasty ring types on mitral leaflet tenting area during acute myocardial ischemia
    • Bothe W, Kvitting J-PE, Stephens EH, et al. Effects of different annuloplasty ring types on mitral leaflet tenting area during acute myocardial ischemia. J Thorac Cardiovasc Surg 2011; 141: 345-353.
    • (2011) J Thorac Cardiovasc Surg , vol.141 , pp. 345-353
    • Bothe, W.1    Kvitting, J.-P.2    Stephens, E.H.3
  • 40
    • 84866439097 scopus 로고    scopus 로고
    • How do annuloplasty rings affect mitral annular strains in the normal beating ovine heart
    • Bothe W, Rausch MK, Kvitting JPE, et al. How do annuloplasty rings affect mitral annular strains in the normal beating ovine heart? Circulation 2012; 126: S231-S238.
    • (2012) Circulation , vol.126
    • Bothe, W.1    Rausch, M.K.2    Kvitting, J.P.E.3
  • 41
    • 54049120720 scopus 로고    scopus 로고
    • Material properties of the ovine mitral valve anterior leaflet in vivo from inverse finite element analysis
    • Krishnamurthy G, Ennis DB, Itoh A, et al. Material properties of the ovine mitral valve anterior leaflet in vivo from inverse finite element analysis. Am J Physiol Heart Circ Physiol 2008; 295: H1141-H1149.
    • (2008) Am J Physiol Heart Circ Physiol , vol.295
    • Krishnamurthy, G.1    Ennis, D.B.2    Itoh, A.3
  • 42
    • 84859033903 scopus 로고    scopus 로고
    • Augmented mitral valve leaflet area decreases leaflet stress: A finite element simulation
    • Xu C, Jassar AS, Nathan DP, et al. Augmented mitral valve leaflet area decreases leaflet stress: A finite element simulation. Ann Thorac Surg 2012; 93: 1141-1145.
    • (2012) Ann Thorac Surg , vol.93 , pp. 1141-1145
    • Xu, C.1    Jassar, A.S.2    Nathan, D.P.3
  • 44
    • 84884975304 scopus 로고    scopus 로고
    • In vivo human cardiac fibre architecture estimation using shape-based diffusion tensor processing
    • Toussaint N, Stoeck CT, Schaeffter T, et al. In vivo human cardiac fibre architecture estimation using shape-based diffusion tensor processing. Med Image Anal 2013; 17: 1243-1255.
    • (2013) Med Image Anal , vol.17 , pp. 1243-1255
    • Toussaint, N.1    Stoeck, C.T.2    Schaeffter, T.3
  • 45
    • 84872794607 scopus 로고    scopus 로고
    • Peak wall stress predicts expansion rate in descending thoracic aortic aneurysms
    • Shang EK, Nathan DP, Sprinkle SR, et al. Peak wall stress predicts expansion rate in descending thoracic aortic aneurysms. Ann Thorac Surg 2013; 95: 593-598.
    • (2013) Ann Thorac Surg , vol.95 , pp. 593-598
    • Shang, E.K.1    Nathan, D.P.2    Sprinkle, S.R.3
  • 46
    • 84919423034 scopus 로고    scopus 로고
    • Local wall thickness in finite element models improves prediction of abdominal aortic aneurysm growth
    • Shang EK, Nathan DP, Woo EY, et al. Local wall thickness in finite element models improves prediction of abdominal aortic aneurysm growth. J Vasc Surg 2013; 1-7.
    • (2013) J Vasc Surg , pp. 1-7
    • Shang, E.K.1    Nathan, D.P.2    Woo, E.Y.3
  • 47
    • 84867231625 scopus 로고    scopus 로고
    • Patient-specific multiscale modeling of blood flow for coronary artery bypass graft surgery
    • Sankaran S, Esmaily Moghadam M, Kahn AM, et al. Patient-specific multiscale modeling of blood flow for coronary artery bypass graft surgery. Ann Biomed Eng 2012; 40: 2228-2242.
    • (2012) Ann Biomed Eng , vol.40 , pp. 2228-2242
    • Sankaran, S.1    Esmaily Moghadam, M.2    Kahn, A.M.3
  • 48
    • 84878285946 scopus 로고    scopus 로고
    • Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve: Scientific basis
    • Taylor CA, Fonte TA, Min JK:, Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve: Scientific basis. J Am Coll Cardiol 2013; 61: 2233-2241.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 2233-2241
    • Taylor, C.A.1    Fonte, T.A.2    Min, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.