메뉴 건너뛰기




Volumn 25, Issue 5, 2014, Pages 466-470

The incidence of phrenic nerve injury during pulmonary vein isolation using the second-generation 28 mm cryoballoon

Author keywords

atrial fibrillation; catheter ablation; cryoablation; cryoballoon ablation; phrenic nerve mapping; pulmonary vein isolation

Indexed keywords

ABLATION DEVICE; ADULT; ARTICLE; BALLOON; CRYOBALLOON; DIAGNOSTIC CATHETER; DIAPHRAGM; FEMALE; FOLLOW UP; FREEZING; HEART ATRIUM FIBRILLATION; HEART LEFT ATRIUM; HOSPITAL DISCHARGE; HUMAN; MAJOR CLINICAL STUDY; MALE; MAPPING CATHETER; MUSCLE CONTRACTION; NERVE INJURY; PHRENIC NERVE INJURY; POSTOPERATIVE CARE; PRIORITY JOURNAL; PULMONARY VEIN ISOLATION; AGED; ATRIAL FIBRILLATION; CONVALESCENCE; CRYOSURGERY; EPIDEMIOLOGY; EQUIPMENT DESIGN; GERMANY; HEART CATHETER; INCIDENCE; INNERVATION; MIDDLE AGED; PATHOPHYSIOLOGY; PERIPHERAL NERVE INJURIES; PHRENIC NERVE; PULMONARY VEIN; SURGERY; TIME; TREATMENT OUTCOME;

EID: 84899635663     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12358     Document Type: Article
Times cited : (102)

References (16)
  • 9
    • 84860139306 scopus 로고    scopus 로고
    • Collateral nervous damages after cryoballoon pulmonary vein isolation
    • Guiot A, Savouré A, Godin B, Anselme F,: Collateral nervous damages after cryoballoon pulmonary vein isolation. J Cardiovasc Electrophysiol 2012; 23: 346-351.
    • (2012) J Cardiovasc Electrophysiol , vol.23 , pp. 346-351
    • Guiot, A.1    Savouré, A.2    Godin, B.3    Anselme, F.4
  • 15
    • 79960021173 scopus 로고    scopus 로고
    • Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation: The first human application
    • Franceschi F, Dubuc M, Guerra PG, Khairy P,: Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation: The first human application. Heart Rhythm 2011; 8: 1068-1071.
    • (2011) Heart Rhythm , vol.8 , pp. 1068-1071
    • Franceschi, F.1    Dubuc, M.2    Guerra, P.G.3    Khairy, P.4
  • 16
    • 84892150254 scopus 로고    scopus 로고
    • Novel electromyographic monitoring technique for prevention of right phrenic nerve palsy during cryoballoon ablation
    • Franceschi F, Koutbi L, Mancini J, Attarian S, Prevot S, Deharo JC,: Novel electromyographic monitoring technique for prevention of right phrenic nerve palsy during cryoballoon ablation. Circ Arrhythm Electrophysiol 2013; 6: 1109-1114.
    • (2013) Circ Arrhythm Electrophysiol , vol.6 , pp. 1109-1114
    • Franceschi, F.1    Koutbi, L.2    Mancini, J.3    Attarian, S.4    Prevot, S.5    Deharo, J.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.