메뉴 건너뛰기




Volumn 29, Issue 3, 2014, Pages 1325-1334

A genetic algorithm-based low voltage ride-through control strategy for grid connected doubly fed induction wind generators

Author keywords

Doubly fed induction generator (DFIG); fuzzy control; genetic algorithms (GAs); low voltage ride through (LVRT); power systems faults; wind power generation

Indexed keywords

ASYNCHRONOUS GENERATORS; ELECTRIC POWER GENERATION; FUZZY CONTROL; GENETIC ALGORITHMS; REACTIVE POWER; WIND POWER; WIND TURBINES;

EID: 84899621936     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2013.2290622     Document Type: Article
Times cited : (135)

References (32)
  • 1
    • 4043169037 scopus 로고    scopus 로고
    • Review of contemporary wind turbine concepts and their market penetration
    • DOI 10.1260/0309524041590099
    • A. D. Hansen, F. Iov, F. Blaabjerg, and L. H. Hansen, "Review of contemporarywind turbine concepts and their market penetration," WindEng., vol. 28, no. 3, pp. 247-263, Jul. 2009. (Pubitemid 39080976)
    • (2004) Wind Engineering , vol.28 , Issue.3 , pp. 247-263
    • Hansen, A.D.1    Lov, F.2    Blaabjerg, F.3    Hansen, L.H.4
  • 3
    • 34250757748 scopus 로고    scopus 로고
    • A review of power convertertopologies for wind generators
    • New York, NY, USA: Elsevier
    • J. A. Baroudi, V. Dinavahi, and A. Knight, "A review of power convertertopologies for wind generators," in Renewable Energy. NewYork, NY, USA: Elsevier, 2007, pp. 2269-2385.
    • (2007) Renewable Energy , pp. 2269-2385
    • Baroudi, J.A.1    Dinavahi, V.2    Knight, A.3
  • 5
    • 34548274089 scopus 로고    scopus 로고
    • Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    • DOI 10.1109/TEC.2006.878241
    • J. Lopez, P. Sanchis, X. Roboam, and L. Marroyo, "Dynamic behaviorof the doubly fed induction generator during three-phase voltage dips,"IEEE Trans. Energy Convers., vol. 22, no. 3, pp. 709-717, Sep. 2007. (Pubitemid 47323587)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.3 , pp. 709-717
    • Lopez, J.1    Sanchis, P.2    Roboam, X.3    Marroyo, L.4
  • 6
    • 76649127421 scopus 로고    scopus 로고
    • Rotorvoltage dynamics in the doubly fed induction generator during gridfaults
    • Jan.
    • F. Lima, A. Luna, P.Rodriguez, E.Watanabe, and F.Blaabjerg, "Rotorvoltage dynamics in the doubly fed induction generator during gridfaults," IEEE Trans. Power Electron., vol. 25, no. 1, pp. 118-130, Jan.2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.1 , pp. 118-130
    • Lima, F.1    Luna, A.2    Rodriguez, P.3    Watanabe, E.4    Blaabjerg, F.5
  • 8
    • 35048853522 scopus 로고    scopus 로고
    • Performance study of a doubly fed wind-power induction generator under network disturbances
    • DOI 10.1109/TEC.2005.853741
    • S. Seman, J. Niiranen, S. Kanerva, A. Arkkio, and J. Saitz, "Performancestudy of a doubly fed wind-power induction generator undernetwork disturbances," IEEE Trans. Energy Convers, vol. 21, no. 4,pp. 883-890, Dec. 2006. (Pubitemid 44824173)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.4 , pp. 883-890
    • Seman, S.1    Niiranen, J.2    Kanerva, S.3    Arkkio, A.4    Saitz, J.5
  • 9
    • 43849096872 scopus 로고    scopus 로고
    • Assessing transient response of DFIG-based wind plants - The influence of model simplifications and parameters
    • DOI 10.1109/TPWRS.2008.919310
    • M. Kayikci and J. V.Milanovic, "Assessing transient response ofDFIGbased wind plants the influence of model simplifications and parameters,"IEEE Trans. Power Syst., vol. 23, no. 2, pp. 545-554, May 2008. (Pubitemid 351695833)
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.2 , pp. 545-554
    • Kayikci, M.1    Milanovic, J.V.2
  • 11
    • 73549094468 scopus 로고    scopus 로고
    • Impacts of Large ScaleWind Penetrationon Energy Supply Industry
    • doi:10.3390/en20401031," [Online]. Available: available
    • J. Kabouris and F. D. Kanellos, "Impacts of Large ScaleWind Penetrationon Energy Supply Industry, Energies 2009, 2, 1031-1041; doi:10.3390/en20401031," [Online]. Available: available: http://www.mdpi.com/1996-1073/2/4/1031.
    • (2009) Energies , vol.2 , pp. 1031-1041
    • Kabouris, J.1    Kanellos, F.D.2
  • 12
    • 70349579256 scopus 로고    scopus 로고
    • A review of grid code technical requirementsfor wind farms
    • M. Tsili and S. Papathanassiou, "A review of grid code technical requirementsfor wind farms," IET Renew. Power Gen., vol. 3, no. 3, pp.308-332, 2009.
    • (2009) IET Renew. Power Gen. , vol.3 , Issue.3 , pp. 308-332
    • Tsili, M.1    Papathanassiou, S.2
  • 14
    • 70349616083 scopus 로고    scopus 로고
    • Ride throughof wind turbines with doubly fed induction generator under symmetricalvoltage dips
    • Oct.
    • J. Lopez, E. Gubia, E. Olea, J. Ruiz, and L. Marroyo, "Ride throughof wind turbines with doubly fed induction generator under symmetricalvoltage dips," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp.4246-4254, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4246-4254
    • Lopez, J.1    Gubia, E.2    Olea, E.3    Ruiz, J.4    Marroyo, L.5
  • 15
    • 59649114419 scopus 로고    scopus 로고
    • Real-time implementationof a STATCOM on a wind farm equipped with doublyfed induction generators
    • Jan./Feb.
    • W. Qiao, G. K. Venayagamoorthy, and R. G. Harley, "Real-time implementationof a STATCOM on a wind farm equipped with doublyfed induction generators," IEEE Trans. Ind. Appl., vol. 45, no. 1, pp.98-107, Jan./Feb. 2009.
    • (2009) IEEE Trans. Ind. Appl. , vol.45 , Issue.1 , pp. 98-107
    • Qiao, W.1    Venayagamoorthy, G.K.2    Harley, R.G.3
  • 16
    • 44449177025 scopus 로고    scopus 로고
    • A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter
    • DOI 10.1109/TPEL.2008.921179
    • P. S. Flannery and G. Venkataramanan, "Fault tolerant doubly fed inductiongenerator wind turbine using a parallel grid side rectifier andseries grid side converter," IEEE Trans. Power Electron., vol. 23, no.3, pp. 1126-1135, May 2008. (Pubitemid 351756688)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1126-1135
    • Flannery, P.S.1    Venkataramanan, G.2
  • 17
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • DOI 10.1109/TEC.2006.875783
    • D. Xiang, L. Ran, P. J. Tavner, and S. Yang, "Control of a doubly fedinduction generator in a wind turbine during grid fault ride-through, "IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 652-662, Sep. 2006. (Pubitemid 46445154)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, L.2    Tavner, P.J.3    Yang, S.4
  • 18
    • 84874918912 scopus 로고    scopus 로고
    • An LVRT control strategybased on flux linkage tracking for DFIG-based wecs
    • Jul.
    • S. Xiao, G. Yang, H. Zhou, and H. Geng, "An LVRT control strategybased on flux linkage tracking for DFIG-based wecs," IEEE Trans. Ind.Electron., vol. 60, no. 7, pp. 2820-2832, Jul. 2013.
    • (2013) IEEE Trans. Ind.Electron. , vol.60 , Issue.7 , pp. 2820-2832
    • Xiao, S.1    Yang, G.2    Zhou, H.3    Geng, H.4
  • 19
    • 83455202755 scopus 로고    scopus 로고
    • An improved low-voltage ridethroughcontrol strategy of doubly fed induction generator during gridfaults
    • Dec.
    • S. Hu, X. Lin, Y. Kang, and X. Zou, "An improved low-voltage ridethroughcontrol strategy of doubly fed induction generator during gridfaults," IEEE Trans. Power Electron., vol. 26, no. 12, pp. 3653-3665,Dec. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.12 , pp. 3653-3665
    • Hu, S.1    Lin, X.2    Kang, Y.3    Zou, X.4
  • 20
    • 9244221126 scopus 로고    scopus 로고
    • Improving powersystem dynamic behavior through doubly fed induction machines controlledby static converter using fuzzy control
    • Nov.
    • R. G. Almeida, J. A. P. Lopes, and J.A. L. Barreiros, "Improving powersystem dynamic behavior through doubly fed induction machines controlledby static converter using fuzzy control," IEEE Trans. PowerSyst., vol. 19, no. 4, pp. 1942-1950, Nov. 2004.
    • (2004) IEEE Trans. PowerSyst. , vol.19 , Issue.4 , pp. 1942-1950
    • Almeida, R.G.1    Lopes, J.A.P.2    Barreiros, J.A.L.3
  • 21
    • 65549086544 scopus 로고    scopus 로고
    • Designing optimal controllers for doubly fed induction generatorsusing a genetic algorithm
    • Oct.
    • J. P. A. Vieira, M. V. A. Nunes, U. H. Bezerra, and A. C. d. Nascimento,"Designing optimal controllers for doubly fed induction generatorsusing a genetic algorithm," IET Gen. Transm. Distrib., vol. 3, no.5, pp. 472-484, Oct. 2009.
    • (2009) IET Gen. Transm. Distrib. , vol.3 , Issue.5 , pp. 472-484
    • Vieira, J.P.A.1    Nunes, M.V.A.2    Bezerra, U.H.3    Nascimento, A.C.D.4
  • 22
    • 61649105219 scopus 로고    scopus 로고
    • Operation of gridconnected DFIG under unbalanced grid voltage
    • Mar.
    • Y. Zhou, P. Bauer, J. A. Ferreira, and J. Pierik, "Operation of gridconnected DFIG under unbalanced grid voltage," IEEE Trans. EnergyConvers., vol. 24, no. 1, pp. 240-246, Mar. 2009.
    • (2009) IEEE Trans. EnergyConvers. , vol.24 , Issue.1 , pp. 240-246
    • Zhou, Y.1    Bauer, P.2    Ferreira, J.A.3    Pierik, J.4
  • 23
    • 56749103139 scopus 로고    scopus 로고
    • Compensation of networkvoltage unbalance using doubly fed induction generator-based windfarms
    • Y. Wang, L. Xu, and B. W. Williams, "Compensation of networkvoltage unbalance using doubly fed induction generator-based windfarms," IET Renew. Power Gen., vol. 3, no. 1, pp. 12-22, 2009.
    • (2009) IET Renew. Power Gen. , vol.3 , Issue.1 , pp. 12-22
    • Wang, Y.1    Xu, L.2    Williams, B.W.3
  • 24
    • 33947313847 scopus 로고    scopus 로고
    • Dynamic modeling and control of DFIG-based wind turbines under unbalanced network conditions
    • DOI 10.1109/TPWRS.2006.889113
    • L. Xu and Y. Wang, "Dynamic modeling and control of DFIG-basedwind turbines under unbalanced network conditions," IEEE Trans.Power Syst., vol. 22, no. 1, pp. 314-323, Feb. 2007. (Pubitemid 46437741)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.1 , pp. 314-323
    • Xu, L.1    Wang, Y.2
  • 25
    • 44449142859 scopus 로고    scopus 로고
    • Coordinated control of DFIG's rotor and grid side converters during network unbalance
    • DOI 10.1109/TPEL.2008.921157
    • L. Xu, "Coordinated control of DFIG's rotor and grid-side convertersduring network unbalance," IEEE Trans. Power Electron., vol. 23, no.3, pp. 1041-1049, May 2008. (Pubitemid 351756681)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1041-1049
    • Xu, L.1
  • 26
    • 60449101280 scopus 로고    scopus 로고
    • Improved control of DFIGsystems during network unbalance using PI-R current regulators
    • Feb.
    • J. Hu, Y. He, L. Xu, and B. W. Williams, "Improved control of DFIGsystems during network unbalance using PI-R current regulators,"IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 439-451, Feb. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.2 , pp. 439-451
    • Hu, J.1    He, Y.2    Xu, L.3    Williams, B.W.4
  • 27
    • 85008063672 scopus 로고    scopus 로고
    • Providingride-through capability to a doubly fed induction generator under unbalancedvoltage dips
    • Jul.
    • J. Santos-Martin, L. Rodriguez-Amenedo, and S. Arnaltes, "Providingride-through capability to a doubly fed induction generator under unbalancedvoltage dips," IEEE Trans. Power Electron., vol. 24, no. 7,pp. 1747-1775, Jul. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.7 , pp. 1747-1775
    • Santos-Martin, J.1    Rodriguez-Amenedo, L.2    Arnaltes, S.3
  • 28
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back PWM converters and its application to variablespeed wind-energy generation
    • R. Pena, J. C. Clare, and G. M. Asher, "Doubly fed induction generatorusing back-to-backPWM converters and its application to variablespeed wind-energy generation," Proc. Inst. Elect. Eng., Elect. PowerAppl., vol. 143, no. 3, pp. 231-241, May 1996. (Pubitemid 126760209)
    • (1996) IEE Proceedings: Electric Power Applications , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 30
    • 84899620759 scopus 로고    scopus 로고
    • A novel crowbar protection technique for DFIG windfarm during fault ride through
    • Jun.
    • O. Noureldeen, "A novel crowbar protection technique for DFIG windfarm during fault ride through," Int. J. Eng.Technol. IJET-IJENS, vol.12, no. 3, pp. 85-95, Jun. 2012.
    • (2012) Int. J. Eng.Technol. IJET-IJENS , vol.12 , Issue.3 , pp. 85-95
    • Noureldeen, O.1
  • 31
    • 67349112843 scopus 로고    scopus 로고
    • Sensorless maximumpower point tracking of wind by DFIG using rotor position phaselock loop (PLL)
    • Apr.
    • B. Shen, B. Mwinviwiwa, Y. Zhang, and B. T. Ooi, "Sensorless maximumpower point tracking of wind by DFIG using rotor position phaselock loop (PLL)," IEEE Trans. Power Electron., vol. 24, no. 4, pp.942-951, Apr. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.4 , pp. 942-951
    • Shen, B.1    Mwinviwiwa, B.2    Zhang, Y.3    Ooi, B.T.4
  • 32
    • 84871647171 scopus 로고    scopus 로고
    • A novel maximum power pointstracking (MPPT) operation of doubly-fed induction generator (DFIG)wind power system
    • Y. Zou, M. Elbuluk, and Y. Sozer, "A novel maximum power pointstracking (MPPT) operation of doubly-fed induction generator (DFIG)wind power system," in Proc. IEEE Industry Applicat. Soc. AnnualMeeting (IAS), 2012, pp. 1-6.
    • (2012) Proc. IEEE Industry Applicat. Soc. AnnualMeeting (IAS) , pp. 1-6
    • Zou, Y.1    Elbuluk, M.2    Sozer, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.